Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
21 Oct 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commissioner Nagercoil City Municipal Corporation
City Municipal Coporation Office Nagercoil 629001 Ph.No. 04652231516
Nagercoil Corporation Modification work for Existing sanitory office to shop and also existing RMS Building Partially Conversion of Sanitary office at Kamaraj Building in Annabusstand ward no.32
2021_MAWS_211667_1
99/2021-2022/E1
Open Tender
Civil Works
Lump-sum
90 days
Nagercoil Corporation Modification work for Existi
Registered Contractor
4 documents required · 4 mandatory
₹0
₹4,000
16 Nov 2021
9 Oct 2021
22 Oct 2021
9 Oct 2021
21 Oct 2021
9 Oct 2021
90 days
Amount
Modification work for Existing sanitory office to shop
Labour for cutting open road for laying water mains or sewercc road
Laying Plain cement concrete 1:4:8 (One cement,four sand and eight aggregates) using 40mm ISS Hard broken granite stone jelly for foundation and basement including watering if found necessary and laid inlayers of 15cm thick, and consolidated including curing, cost and conveyance of all materials to work site all labour and incidental charges etc,. complete complying with standard specifications.(TNBP No.28)
Providing steel centering for sides and soffits including supports and strutting upto 1:10/1:20 up to 3.29m height for plain surfaces such as RCC slabs, rectangular beams, Tee beams, bed blocks, Culvert body walls, deck slabs, retaining walls, staircase, Landing slab, landing beams, canopy etc., with all cross bracings using mild steel sheets of size 90mm x60mmx10gauge stiffened into welded mild steel angles of size 25mmx6mm for boarding laid over silver oak (Country wood) joists of size 10cmx 6.5cm spaced at 90cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at 15cm c/c including cost of nails, ropes, all labour charges and incidental charges etc. complete complying with standard specification.(TNBP Spl. No.154 A)
Reinforced cement concrete 1:1½:3 (one cement and half sand and three aggregates) using 20mm ISS Hard broken granite stone jelly for Reinforced cement concrete works excluding cost of shuttering, and cost of reinforcement but including cost and conveyance of materials to work site, all labour charges and incidental charges for mixing and laying concrete,finishing the surface nearly rough, compacting using vibrators, curing etc, complete complying with standard specification.(TNBP No.30)
Supplying, fabrication and placing in position of steel reinforcement using mild steel (or) ribbed tar steel rods, for all RCC works as per the design given by the departmental officers including cost of steel and binding wire and all labour charges for cutting, bending rods, tieing into grills, placing in position etc., complete as directed by the departmental officers.( TNBP No: 15886)
Brickwork in cement mortar 1:5 (one cement and five sand) using country bricks of size 83/4"x41/4"x23/4" including curing, cost and conveyance of all materials to site and all labour charges etc. complete as per standard specifications
Platering with cement mortar 1:5 (one cement and five sand) 12mm thick including cost and conveyance of all materials finishing curing and all labour charges etc. complete as per standard specification
Supplying and fixing of RCC Precast slab withcement concrete 1:2 : 4 mix using 20 mm metal for 100mm thick including all cost and conveyance of all materials and all labour and materials charges etc complete as per Standard specification
Laying Plain cement concrete 1:2:4 (One cement,two sand and four aggregates) using 20mm ISS Hard broken granite stone jelly for plain cement concrete works excluding cost of shuttering, and centering including all labour charges and incidental charges for cost and conveyance of all materials to work site, mixing and laying concrete finishing the surface nearly rough, compacting using vibrators, curing etc, complete complying with standard specification.(TNBP No.28)
Painting two coats with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scribing clean remove of dire etc. complete and including cost of necessary plaster of paris, putty brushes, wherever required and all labour charges, scaffolding charges etc. complete as per standard specification
Painting two coats over new iron work with ready mixed paint of approved quality and colour including cost of all materials and labour charges, brushes and scaffolding charges etc. complete as per standard specification
Supplying, fabricating and fixing in position of aluminium anodised natural colour matt finish door half glazed and half PLB board / fully 12mm thick PLD board / fully 5.5mm thick glazec door using rectangular Alu. Lox section of following sizes for frame and stutter with necessary accessories such as rubber beading, aluminium clips, best double action floor springs / door doser, handles, locks and glass including all nateriais, labour and power consumption charges required for fabrication if necessary chipping, dismanting making necessary holes in RCC columns, booms, or masonry wherever necessary with power drill to the extent required and made good to the briginal conditions after fixing etc. complete. The aluminium eurface is to be addised with matt finish under electrically cortrollee condition in accordance with SI specification 1000/1902 of andic film thickness of not less than 15 microns (fifteen) for all sections. All the materials should be got approved by the Engineer-in-charge before fixing in position as directed.
Wirinng with 2x1.5sq.mm (22/0.3) PVC insulated SC. unsheathed Cu.Conductor of 1100V garade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch inflush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light/fan point (for electronic regulator) (5 points per coil)(SD 22)
Supply and fixing of single box type 4'36 W flu fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting(SD 87)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .