Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC DALHOUSIE ROAD BYE PASS CHOWK PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC lowest bid | |
| 2 | L2₹21.6 L+₹57,340.50 (2.73%)Rejected-Finance VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹22.0 L+₹97,719.60 (4.65%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹22.4 L+₹1.3 L (6.37%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid |
Tender Value
₹23.6 L
EMD Value
₹47,100
Closing Date
24 Aug 2020, 6:00 pmClosed
GE South Mamun
GE South Mamun
PROVN OF SEPTIC TANK AND SOAKAGE WELL NEAR BLDG NO. P-258 SPECIAL REPAIR TO ROOF TREATMENT REPLACEMENT OF DOORS WINDOWS INTERNAL ELECTRIFICATION IN BLDG NO NP-07A AND CERTAIN REVENUE WORKS AND MINOR WORKS UNDER AGE B/R-II AND AGE E/M OF GE (SOUTH)
2020_MES_364614_1
GE(S)/M-30/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE South Mamun
Refer Tender documents
8 documents required · 8 mandatory
₹500
GE South mamun
₹47,100
Yes
8 Sept 2020
28 Jul 2020
26 Aug 2020
28 Jul 2020
24 Aug 2020
12 Aug 2020
28 Jul 2020 - 3 Aug 2020
Amount
Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose of soil.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
Excavating over areas n. exc. 1.5 m deep and getting out in hard/dense soil.
All as per item No. 4 above but exc. 1.5 m but n. exc. 3 m deep.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point.
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
M&L for form work to sides of flat, rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical to batter.
M&L for form work to sides and soffits of flat, rough finished surfaces of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M&L for form work to flat, rough finished surfaces of concrete of chullah hoods, chajjas, troughs and similar items including edges.
M&L for form work to sides of square, rectangular or polygonal, rough finished surfaces of concrete of pillars, posts, struts, piers, columns and stanchions.
M&L for form work to soffits of flat, rough finished surfaces of concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick(Horizontal or sloping)
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but n. exc. 20 cm wide, rough finished surfaces of concrete.
M&L for form work to flat, rough finished surfaces faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses etc.; vertical or to batter,.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs and mass concrete.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in beams, cantilevers, bressumers, lintels.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in chajjas.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in columns, pillars, piers, posts and struts.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like.
M&L for RCC M-30 (design mix) using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs and mass concrete.
M&L for RCC M-30 (design mix) using 20 mm graded stone aggregate in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
M&L for RCC M-30 (design mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for brick work with sub class 'B’ bricks using old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM 1:6
M&L for brick work with sub class 'B’ bricks, old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B’ bricks using old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM 1:4
Brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:6) all as specified and directed.
Brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:4) all as specified and directed.
M&L for rendering 5 mm thick in CM 1:4 mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, over and including 10 mm thick rendering in CM 1:6 on brick work or concrete surfaces. Note:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for rendering 10 mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement.
M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces in ceiling including finishing even and smooth without using extra cement.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash.
M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted, over and including a coat of alkali-resistant priming paint all as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 2 mm thick wall care putty all as directed.
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (01 No.), hinges type B-21 100 mm long (02 Nos.) suitable handle (01 No.) complete all as specified.
S&F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified.
S&F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified.
S&F 35 mm thick factory made, second class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated.
S&F 35 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), supplied and fitted to chowkats.
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour (Wenga/teak colour) PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with 5 mm thick x 15 mm wide PVC sheet beading used inside stiles and rails and decorative PVC brading of 10 mm x 10 mm (90°) and joined together with solvent cement, and fixing in the frame at site as per specification & drawing.
S&F box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads supplied with shutters in square n. exc. 0.5 sqm in each pane.
S&F sheet glass 3 mm thick, figured glass, pin headed type and glazing with oil putty or wooden beads supplied with shutters in square n. exc. 0.5 sqm in each pane.
S&F stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters.
S&F butt hinges of size 100 mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodized and fixed, type B-21
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 250 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F extruded aluminium alloy handles, fabricated type, anodized of size 150 mm.
S&F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges.
S&F 20 mm bore drapery rod in any length, high strength MS pipe with 1 mm thick PVC wood grain coating including brackets and knobs all as directed by Engineer-in-Charge.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in sub base.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors.
M&L for hard core of broken stone or boulders of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate in plinth protection. Concrete shall be laid in alternate bays n.exc 3 m in length finished fair and even including provision of joints of 6 mm wide and 10 mm deep along the wall and bays filled with bitumen mastic (1:3).
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) in floors etc. area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6.
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) in floors etc. area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6.
M&L for glazed ceramic tiles, coloured, 350x250x7mm/450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on brick or concrete surfaces.
M&L for industrial grade matt finish type-V, thickness 15-16 mm, floor tiles in floors etc. (square/rectangular), area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm, set & jointed in neat cement slurry & pointed in epoxy grout to match over and including 15 mm thick screed bed in CM 1:6.
M&L for preparation of new or previously untreated wooden surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms.)
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms.)
Supply and laying 15 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Supply and laying 20 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Cutting existing steel tubing 25 mm bore for alterations or additions (Each cut measured) necessarily done in position without taking down.
S&F 15 mm bore bib taps, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F 15 mm bore stop valve/angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F 20 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
S&F stainless steel grating doom 100 mm dia fixed with cement mortar in floors.
S&F stainless steel grating doom 100 mm dia with waste hole, fixed with cement mortar in floors.
S&F vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F 15 mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S&F vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, and fixed complete all as specified.
S&F PVC pressure jet for EWC, heavy duty with 1.50 m tube.
S&F vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, with CI 'P' trap, embedded and set in PCC 1:5:10 type E-2.
S&F PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia.
S&F vitreous china bowl urinal flat back, size 465x355x265mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, brass chromium plated perforated waste coupling, fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length complete
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long.
S&F cast iron floor trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).
S&F salt glazed stoneware gully traps of size 150x150 mm, square or round mouthed, type ‘P’.
S&F 100 mm bore cast iron, sand cast, soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors.
S&F 75 mm bore cast iron, sand cast, soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls.
S&F 100 mm bore cast iron, sand cast, soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls.
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured).
S&F 100 mm bore cast iron bends (any radius) with oval access door, diminishing pieces or tapers (larger bore measured).
S&F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured).
S&F 100 mm bore CI cowl.
S&F 75 mm bore CI cowl.
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) when concrete is still green mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement finished even and smooth without using extra cement complete all as specified. NOTE : Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for 10 mm thick rendering in CM 1:4 on brick work or concrete surfaces mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, finished even and smooth without using extra cement, complete all as specified. NOTE : Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for 10 mm thick rendering in CM 1:3 on brick work or concrete surfaces mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, finished even and smooth without using extra cement, complete all as specified. NOTE : Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in surface channels, drains (forming fair finished channel shall be measured and paid for separately).
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends, etc all as specified.
M&L for PCC 1:2:4 type B1 using 20 mm stone aggregate in lintels up to 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under and haunching against the sides of pipes after they are laid and tested.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 200 mm bore, including packing under and haunching against the sides of pipes after they are laid and tested.
M&L for salt glazed stone ware drain pipes of 150 mm internal dia, grade ‘A’ ISI marked laid to slope in trenches, jointed in CM 1:1 and tested complete all as specified and as directed.
M&L for 200 mm bore reinforced concrete pipes class NP2, laid and jointed complete with collars.
M&l for cutting into existing manholes for connecting new drains of 150 mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½ round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
Supply only liquid water proofing compound.
M&L for treating the back fill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with back fill to be measured).
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimeter wall.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Rough excavation in soft/loose soil n. exc. 1.5 m deep and getting out.
Removing excavated material (soil) exc. 1.5 Km but n. exc. 5 Km and depositing where directed at a level n.exc. 1.5 m above the starting point.
Spreading and leveling in layers n. exc. 25 cm thick including watering and well ramming as required.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
S&F anodized aluminium frame for doors, windows, ventilators, partition wall etc. with one or more rebates, including joining cleat for fixing etc. complete all as specified.
S&F anodized aluminium door shutters, aluminium sections weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified.
S&F in repairs 15 mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S&F in repairs 15 mm bore bib taps, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs 15 mm bore stop valve/angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges.
S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F in repairs stainless steel grating doom 100 mm dia fixed with cement mortar in floors.
S&F in repairs stainless steel grating doom 100 mm dia with waste hole, fixed with cement mortar in floors.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, and fixed complete all as specified.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia.
S&F in repairs PVC pressure jet for EWC, heavy duty with 1.50 m tube.
S&F in repairs vitreous china urinal, half stall type, white complete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, brass chromium plated perforated waste coupling, fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length complete.
Dismantling water tanks of any description, exc. 250 & n. exc. 500 litres capacity and removing from site.
Dismantling water tanks of any description, exc. 500 & n. exc. 1000 litres capacity and removing from site.
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removing from site.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site.
S&F in repairs 20 mm bore drapery rod in any length, high strength MS pipe with 1 mm thick PVC wood grain coating including brackets and knobs all as directed by Engineer-in-Charge.
S&F in repairs 110 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints laid in trenches or in floors/fixed to walls.
S&F in repairs 110 mm bore UPVC (SWR) bend, suitable for type ‘B’ pipes, any radius.
M&L for 15 mm thick rendering in CM 1:4 over concrete surfaces (Roof) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement complete all as specified. NOTE: Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mm thick) weight not less than 3.50 Kg/Sqm reinforced with non-woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 150 mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.
M&L for 18-20 mm thick black granite (of any type) work (table rubbed and polished) bull nosed on front face, in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed in CM 1:4.
S&F rolled mild steel of grade Fe-290 (Grade E-165) in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. including dismantling existing trusses and removing from site.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws as specified including dismantling existing AC/CGI/Fibre glass sheets and removing from site.
S&F 80 mm thick, M-40 grade, coloured (red/yellow) glossy finish, machine pressed PCC interlocking paver block, with grey cement and pigment, any shape and size laid dry over and including 50 mm thick screened river washed sand cushion.
S&F 60 mm thick, M-35 grade, coloured (red/yellow) glossy finish, machine pressed PCC interlocking paver block, with grey cement and pigment, any shape and size laid dry over and including 50 mm thick screened river washed sand cushion.
M&L for PCC 1:2:4 type B1 using 20 mm stone aggregate in kerbs of interlocking tiles and the like as directed.
M&L for Soak well including excavation and earth work in any type of soil, foundation in PCC 1:4:8, walls of honey combed and solid in CM, RCC M-25 concrete, brick work in CM, RCC cover slab in M-25, brick masonary, filling with brick bats complete of size 3.00 m dia X 4.50 m deep (effective depth) all as specified and shown on drg TD Drg No CEPZ/C-TD/013/13 sheet 1/5 to 5/5.
Blank
M&L for PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregate in cills, steps, bands, copings, bed plates, blocks for inserting hold fasts, filling back of chowkats etc. and the like including weathering, slightly rounded or chamfered angles and throating as directed.
M&L for 15 mm thick rendering in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces.
M&L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover for:- (a) One light/fan point controlled by one, one way switch.
All as per item No. 158.00 above but one 3 pin 5 or 6 Amps socket outlet on independent board with other switches as directed.
All as per item No. 158.00 above but one 3 pin 5 or 6 Amps socket outlet on same board with other switches as directed.
M&L for point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1. 8mm heavy duty including conduit accessories concealed in wall, ceiling etc including sunken type pressed steel terminal boxes of size 175/100mm with 3mm thick bakelite sheet cover white/coloured including 2.5 Sqmm, single core, PVC insulated but unsheathed copper conductor FRLS 1100 volts grade cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board.
S&F switch piano flush button single pole one way 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F switch piano flush button single pole one way 16 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F socket out let, 5 pin 6 amps multi purpose 2 in 1 flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F socket out let, 6 pin 6 & 16 amps multi purpose 2 in 1 flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F ceiling fan AC single phase 230/240 V of size 1200 mm sweep BEE 5 star rated including connecting with PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 sqmm all as specified and directed by Engineer-in-Charge.
S&F fan regulator electronic, switch type hum free with polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically all as specified and directed by Engineer-in-Charge.
S&F lamp holder insulated body with back plate for batten fittings polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F ventilating fan made out of high quality engineering plastic, resistant to colour change with anti static properties, 300mm sweep suitable to work on 230 Volt 50 Hz AC supply model ventilair DX of Havells or equivalent of Ceompton.Bajaj including connecting to ceiling rose all as required or direction by Engineer-in-Charge
S&F LED batten fitting 20 W 4 feet long with inbuilt LED tube rod complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F 10W LED Bulkhead fitting with inbuilt LED Lamp complete all accessories prewired and connecting electrically to ceiling roase using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F surface mounted 1x10 watt LED Mirror light fittins, prewired, decorative luminaire with inbuilt LED tube rod and acrylic cover with all accessories and making connection using 3 core, 0.50 sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
S&F building security light luminaire 25 W LED 5000 K AC 230 volts, new generation saving & enviromental friendly long life versatile pressure die cast aluminium luminairies with high power LED as light source complete making connection with street light/building security light box or OH line using PVC insulated and sheathed single core multi stranded copper conductor cable of size 1.5 sqmm including suitable size of bracket and light grade pipe for mounting of fitting all as specified and directed by Engineer-in-Charge.
M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete for:- (a) One light/fan point controlled by one, one way switch.
All as per item No. 175.00 above but one 3 pin 5 or 6 Amps socket outlet on independent board with other switches as directed.
All as per item No. 175.00 above but one 3 pin 5 or 6 Amps socket outlet on same board with other switches as directed.
M&L for modular point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete for one 3 pin 15 or 16 Amps socket outlet on independent board.
S&F modular switch 1 way 6 Amp, 1 module complete all as specified and directed.
S&F modular switch 1 way 16 Amp, 1 module complete all as specified and directed.
S&F modular socket 6 Amp, 2/3 pin mutipurpose 2 module complete all as specified and directed.
S&F modular socket 6 Amp/16 Amp, 6 pin multi purpose 2 module complete all as specified and directed.
S&F modular fan step regulator, 120W, 2 module, hum free and connecting electrically all as specified and directed by Engineer-in-Charge.
M&L for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 4 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
S&F MCB single pole 230 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F MCB single pole and neutral 240 volts any rating from 10 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F in repairs and testing factory made sheet metal enclosure disribution board for MCCB as incomer and MCB as outgoing 415 volts 3 phase 50 C/s 4 way with double door, IP - 43 protection IK-09 complete with appropriate size copper bus bar and neutral link duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge as per Cat Part No. 607770 of Make Legrand or equivalent of Make : L&T/Merlin Gerin multi-9 complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in repairs single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp ‘C’ curve type, 230 volts, 10 KA.
S&F in repairs and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with single door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge as per Cat Part No. 6077708 of Make- Legrand or equivalent of any Make specified in Appx 'B'.
S&F in repaies MCB single pole 230 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F in repairs MCB single pole and neutral 240 volts any rating from 63 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F exhaust fan, heavy duty, AC single phase 450 mm sweep complete with louvers including fixing/grouting of frame in wall opening complete & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan.
M&L for taking down ceiling fan and hanging the same after repair and connecting up including provision of cable from ceiling rose or connector to fan.
S&F LED lamp 12 watts
M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
All as per item No. 196 but in repairs.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 10 Sqmm 2 core size. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 16 Sqmm 4 core size including retrieving/taking out/taking down old unserviceable cable from duct/trenches/pipes/pole/wall etc. including brick cover and protection pipe and disconnecting the connections. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore.
Note:- Cutting chases in walls/floors/ceilings wherever required for electric work shall be deemed to be included in respective item of Schedule ‘A’.
M/S CANTILEVER ENGINEERS
abrol enterprises
M/S J N TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .