| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹35.0 L+₹20,642 (0.59%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹35.7 L+₹90,569 (2.60%)Rejected-Finance NO 8 1 KHB MAIN ROAD OPP NATURE VIEW APARTMENT MANORAYAN PALYA RT NAGAR BANGALORE 560 032 | BENGALURU URBAN | KARNATAKA | 560032 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹36.5 L+₹1.7 L (5.03%)Rejected-Finance NO 3 KEMPANNA ROAD MARUTHI SEVA NAGAR POST BANGALORE 560 033 BANGALORE KARNATAKA | BENGALURU URBAN | KARNATAKA | 560033 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹36.7 L+₹1.9 L (5.45%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹40.8 L
EMD Value
₹81,600
Closing Date
24 Aug 2020, 6:00 pmClosed
CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
SPL REPAIRS TO 04 X ANIMAL SHED (BLDG NO P08, P09, P10 and P11) OF AT COY,ASC CENTRE (NORTH)1 ATC UNDER GE CENTRAL) BANGALORE
2020_MES_360922_1
85993/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) BANGALORE
₹81,600
Yes
HQ CWE ARMY BANGALORE
5 Oct 2020
14 Jul 2020
26 Aug 2020
14 Jul 2020
24 Aug 2020
10 Aug 2020
14 Jul 2020 - 27 Jul 2020
27 Jul 2020
Amount
Dismantling cement (corrugated, semi corrugated etc,) sheets in roof covering complete all as directed
Pre-painted galvalume aluminium zinc AZ 150 coating GI based corrugated steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre-painted galvalume aluminium zinc AZ 150 coating GI based plain sheet steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed wih coatch screw and washer in roof, wall etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls or concrete ceiling etc, incl raking out joints, hacking for key scrubbing down with water, etc complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 incl finished even and smooth (without using extra cement) complete all as specified and directed.
Supply and fixed in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground floor) complete all as directed.
100 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate), as in floors complete all as specified and directed.
Demolition of cement concrete (Reinforced) in drain/ manhole cover not exceeding 15 cm thickness (below or above ground floor) complete all as directed
Providing precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in cover slabs including form work set in CM 1:4 complete all as specified and directed.
Taking down rain water / waste / soil pipes ( any size or pattern ) including all fittings and removing form site complete all as directed.
10 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connnections, including removing from site complete all as dirceted.
Taking up or down 20 mm bore steel tubing and connnections, including removing from site complete all as dirceted.
15 mm bore tubes, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
20 mm bore tubes, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply and fixed in reapir 15 mm bore stop valves, fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as directed.
S&F in repair 15 mm bore bib tap chromium plated cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as directed.
M&L for 75 mm thick, PCC 1:3:6 type C1 (using 20mm graded stone aggregate), finished even and smooth without using extra cement.as in plinth protection incl joints filling complete all as specified and directed.
Surface excavation n exc. 30 cm deep and average 15 cm deep in soft/loose soil complete all as directed.
Hardcore of guage broken sotne or boulders exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as directed.
Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in coping, kerbs,benching and the like, including weathering slighthy rounded or chamfered angles and throating as directed including necessary form work complete all as directed.
75 mm thick PCC (1:2:4) type-B1 using 20mm grade aggregate as in levelling course/ sub base of floor etc, Concrete surfaces finished fair and even surface complete all as directed.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade With Grey cement and with pigment laid over 50 mm thick sand cushion and compacted with mechanical plate vibrator complete all as specified and directed (Note : Sand filling shall be measured and paid separately).
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Precast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in block masonry with solid blocks, exc 10 cm in width and setting in mortar complete 1:4 complete all as specified and directed.
Brickwork with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
Dismantling wrought iron or mild steel works of any description not otherwise provided for complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikers framed guard bars barred iron doors ladders; framed balusters walk ways railings framework of watertanks and similar work conforming to Fe-290 Gde-165 complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
Preparation of old painted steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coats of synthetic enemel paint complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
Preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enemel paint over a coat of red oxide zinc chrome specified as directed complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 incl finished even and smooth (without using extra cement) complete all as specified and directed.
Taking down carefully any type of point wiring (light, fan, bell socket or power), complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and directed.
Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor FRLS 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic grey conduit conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including FRLS 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-
(a) One light or fan point controlled by one 5 Amps switch one way
All same as per item No 42 here-in-before but with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.50 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
Switch piano, flush button single pole, 5 Amps one way.
Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose.
Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC square blocks.
Supply and fixed in replacement LED tube light fitting of 22 watts 6000K, 230 volts, with long lasting aluminium body with slim & sleek looks all pre-wired fixed on walls with all fixing accessories such as 2 Nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-Charge. Make- Havells CAT Part NO : ENDURALINEARNEOBS22WLED830SPCWH or equivaalent in specified make.
Supply and fixed in replacement of 25 watts, 230 volts, Endura Pearl , New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and directed by Engr-in-Charge. Make- Havells CAT Part NO : ENDURAPEARLSL25WLED757SASYTOPC.
Stepped Socket type electronic fan regulator, 230 volts, flush type, suitable for 1200mm sweep fan, fixing on board and making necessary electrical connection etc complete all as directed.
Taking down old unsv ceiling fan any type, dismantling blades and removing, depositing fan and blades to MES store yard.
Energy efficient Ceiling fan 1200mm sweep, 5 Star rated single phase 230/240 volts AC and connecting up to including provn of porcilin connector and flexible three core copper conductor of size 23/0.0076 from ceiling rose or connector to ceiling fan and testing on completion, complete including hanging fan to the wooden/steel stresses/angular supports using heavy duty fan down MS tubing and MS fan clamp duly painted with synthetic enammeled paint, etc all as directed by engr-in-charge. Make : Bajaj/Crompton Greaves / Usha / Orient Note : Down rod, fan fixing MS clamps and and ceiling fan regulator will be measured and paid separately.
Fan clamp fabricated out of 25x5mm MS flat fixed on angle iron/truss/GI Tubing with bolts, nuts, rubber bushes and washer etc complete suitable to fix ceiling fan including painting the exposed steel surface with two coats of first quality synthetic enammeled paint all as specified and directed.
Sheet metal enclosure (ISI marked) distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
MCB single pole 6 to 32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete all as specified.
MCB single pole & neutral 32 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete all as specified.
Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note : 2 Runs of 4 Sqmm Cable , 1 run of 4.0 Sqmm single core copper cable and 1 run of non metalic PVC conducit shall be measured as single run).
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including testing and dismantling of old earthing complete all as directed.
LT U/G cable XLPE insulated armoured heavy duty 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2core connetion to LT pole and DB with suitable size thimbles, cable glands etc including taking out of olf cable of any size complete all as specified and directed..
Excavation in trenches in hard/dense soil, not exc 1.5 mtr wide and n exc 1.5 mtr in depth; for foundation, laying pipes/elect cables etc, and getting out complete all as specified and directed..
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated materials of soil not exc. 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and spread river sand to required width at bottom and top for cable cushioning (not less 18 cm thick in layer after punning) all as specified in SSR Part-I complete all as directed.
Supply and lay common burnt old size bricks of sub class B laid at right angle on the cable complete in trenches for cable protection complete all as directed by Engr-in-charge.
Mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia.
Steet light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
Taking branch connection from existing distribution GI pipe of bore dia of 25mm including, cutting, threading, inserting, GI fitting i.e socket, nipple, union and unequal size Tee to take branch connection of 25 mm bore dia all as dirceted by engr-in-charge at site.
Supply and fixed in repair GI pipe medium grade size 25mm bore with all necessary fitting fixing on wall ceiling or laid in trenches/ under floors complete all as directed.
Gun metal gate valve with iron wheel head screwed both ends for iron pipe fixed for size 20mm bore dia complete all as directed.
Supply, hosting and fixing rotational moulded polythene water storage tank (cylindrical vertical with close top ISI marked) 1000 Ltrs capacity including PVC ball brass valve with polythene float and fly nut for 25mm bore of pipe with polythene float, fixed in position in repairs where ordered and making necessary connection and testing complete all as directed.
RASHMI BUILDERS
Sangam Construction
M AND V ENTERPRISES
Harish Constructions
Omkar Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .