Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹49.2 L+₹2.9 L (6.16%)Rejected-Finance | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹50.9 L+₹4.6 L (9.87%)Rejected-Finance | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹51.7 L+₹5.4 L (11.6%)Rejected-Finance 403 NARSINGH NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | JABALPUR | MP | 482005 | L4 | Rejected-Finance Highest amount quoted | |
| 5 | Rejected-Technical 968 BAPOO NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | - | Rejected-Technical Not enlisted in requisite category of work ie b (i) |
Tender Value
₹47.6 L
EMD Value
₹95,500
Closing Date
18 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
COMPREHENSIVE REPAIR REPLACEMENT OF WATER GENERATION, SUPPLY AND DISTRIBUTION SYSTEM INCLUDING MOTORS, PUMPS AND ALLIED WORK OF OTM MD ACCN OF ZONE B AND REPAIR AND MAINT OF WINTER APPLIANCE IN ZONE B AREA UNDER AGE EM OF GE (EAST) JABALPUR
2023_MES_618251_3
8580/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Garrison Engineer (East) Jabalpur
D b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹95,500
Yes
31 May 2024
27 Dec 2023
20 Jan 2024
27 Dec 2023
18 Jan 2024
4 Jan 2024
27 Dec 2023 - 29 Dec 2023
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth in any type of soil complete all as specified and directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the statring point complete all as specified and directed.
Cutting existing cast iron pipes of size 200 mm bore in any position for insert of new pipe/tees, branches etc complete all as specified and directed.
Cutting existing cast iron pipes of size 150 mm bore in any position for insert of new pipe/tees, branches etc complete all as specified and directed.
Cutting existing cast iron pipes of size 100 mm bore in any position for insert of new pipe/tees, branches etc complete all as specified and directed.
Cutting existing cast iron pipes of size 80 mm bore in any position for insert of new pipe/tees, branches etc complete all as specified and directed.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints of 200 mm size including burning out joints and recovering lead complete all as specified and directed.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints of 150 mm size including burning out joints and recovering lead complete all as specified and directed.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints of 100 mm size including burning out joints and recovering lead complete all as specified and directed.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints of 80 mm size including burning out joints and recovering lead complete all as specified and directed.
Supply and laying pipe ductile iron (DI) pipes with spigot and socket ends centrifugally cast S/S including specials, Class “K-9”, 200 mm bore in any length laid in trenches of size complete all as specified and directed.
Supply and laying pipe ductile iron (DI) pipes with spigot and socket ends centrifugally cast S/S including specials, Class “K-9”, 150 mm bore in any length laid in trenches of size complete all as specified and directed.
Supply and laying pipe ductile iron (DI) pipes with spigot and socket ends centrifugally cast S/S including specials, Class “K-9”, 100 mm bore in any length laid in trenches of size complete all as specified and directed.
Supply and laying pipe GI tubes, 'medium grade pipes with spigot and socket ends centrifugally cast 80 mm bore in any length laid in trenches of size complete all as specified and directed.
M&L for run lead joints for 200 mm bore size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed.
M&L for run lead joints for 150 mm bore size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed.
M&L for run lead joints for 100 mm bore size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed.
M&L for run lead joints for 80 mm bore size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed.
S&F rubber gasket joint for flanged end pipe & fittings of size 200 mm bore pipes complete all as specified and directed.
S&F rubber gasket joint for flanged end pipe & fittings of size 150 mm bore pipes complete all as specified and directed.
S&F rubber gasket joint for flanged end pipe & fittings of size 100 mm bore pipes complete all as specified and directed.
S&F rubber gasket joint for flanged end pipe & fittings of size 80 mm bore pipes complete all as specified and directed.
S&F upto 150 mm bore dia spigot/flanged/ socketed CI fittings such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc complete all as specified and directed.
S&F upto 200 to 300 mm bore dia spigot/flanged/ socketed CI fittings such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc complete all as specified and directed.
M&L for cutting existing steel tubing of 40/50 mm pipe for alterations or additions (each cut measured) complete all as specified and directed.
M&L for cutting existing steel tubing of 25 mm pipe for alterations or additions (each cut measured) complete all as specified and directed.
M&L for cutting existing steel tubing of 20 mm pipe for alterations or additions (each cut measured) complete all as specified and directed.
M&L for cutting existing steel tubing of 15 mm pipe for alterations or additions (each cut measured) complete all as specified and directed.
Taking up or down GI tubing and connections of 50 mm bore pipe line including cleaning for refixing complete all as specified and directed.
Taking up or down GI tubing and connections of 40 mm bore pipe line including cleaning for refixing complete all as specified and directed.
Taking up or down GI tubing and connections of 25 mm bore pipe line including cleaning for refixing complete all as specified and directed.
Taking up or down GI tubing and connections of 20 mm bore pipe line including cleaning for refixing complete all as specified and directed.
Taking up or down GI tubing and connections of 15 mm bore pipe line including cleaning for refixing complete all as specified and directed.
Supply laying jointing, threading 50 mm bore GI tubing medium grade laid in trenches with socket joint together with and including all fittings (such as bend, elbow, tees, short pices connector, caps, plug and union etc) by cutting welding etc complete all as specified and directed.
Supply laying jointing, threading 40 mm bore GI tubing medium grade laid in trenches with socket joint together with and including all fittings (such as bend, elbow, tees, short pices connector, caps, plug and union etc) by cutting welding etc complete all as specified and directed.
Supply laying jointing, threading 25 mm bore GI tubing medium grade laid in trenches with socket joint together with and including all fittings (such as bend, elbow, tees, short pices connector, caps, plug and union etc) by cutting welding etc complete all as specified and directed.
Supply laying jointing, threading 20 mm bore GI tubing medium grade laid in trenches with socket joint together with and including all fittings (such as bend, elbow, tees, short pices connector, caps, plug and union etc) by cutting welding etc complete all as specified and directed.
Supply laying jointing, threading 15 mm bore GI tubing medium grade laid in trenches with socket joint together with and including all fittings (such as bend, elbow, tees, short pices connector, caps, plug and union etc) by cutting welding etc complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc) of 20 mm bore. Note : Taking out pipe line shall be measured and paid separately under relevent items.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc) of 25 mm bore. Note : Taking out pipe line shall be measured and paid separately under relevent items.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc) of 40/50 mm bore. Note : Taking out pipe line shall be measured and paid separately under relevent items.
Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, trenches etc) of 15 mm bore. Note : Taking out pipe line shall be measured and paid separately under relevent items.
Taking down unserviceable sluice valve/NRV (check valve, clack valve, one way valve or retention valve)/ Air Release Valve of size 80-200 mm dia complete all as specified and directed.
S&F in replacement of sluice valve flanged end drilled type with steel spindle including nuts, bolts and jointing materials class PN-1.6 ISI marked of size 80 mm bore complete all as specified and directed.
S&F in replacement of sluice valve flanged end drilled type with steel spindle including nuts, bolts and jointing materials class PN-1.6 ISI marked of size 100 mm bore complete all as specified and directed.
S&F in replacement of sluice valve flanged end drilled type with steel spindle including nuts, bolts and jointing materials class PN-1.6 ISI marked of size 150 mm bore complete all as specified and directed.
S&F in replacement of sluice valve flanged end drilled type with steel spindle including nuts, bolts and jointing materials class PN-1.6 ISI marked of size 200 mm bore complete all as specified and directed.
S&F in replacment of Non Return Sluice Valve drilled type with steel spindle including nuts, bolts and jointing materials ISI marked of size 80 mm bore complete all as specified and directed.
S&F in replacment of Non Return Sluice Valve drilled type with steel spindle including nuts, bolts and jointing materials ISI marked of size 100 mm bore complete all as specified and directed.
S&F in replacment of Non Return Sluice Valve drilled type with steel spindle including nuts, bolts and jointing materials ISI marked of size 150 mm bore complete all as specified and directed.
S&F in replacment of Non Return Sluice Valve drilled type with steel spindle including nuts, bolts and jointing materials ISI marked of size 200 mm bore complete all as specified and directed.
S&F in replacement of air release valve 80 mm dia of cast iron air valves with two air outlets, conforming to IS-14845 complete all as specified and directed.
S&F in replacement of air release valve 100 mm dia of cast iron air valves with two air outlets, conforming to IS-14845 complete all as specified and directed.
S&F in replacement of air release valve 150 mm dia of cast iron air valves with two air outlets, conforming to IS-14845 complete all as specified and directed.
Taking out sluice valves of size 80 mm, re-facing, re-grinding, replacing checknut and re-fixing complete all as specified and directed.
Taking out sluice valves of size 100 mm, re-facing, re-grinding, replacing checknut and re-fixing complete all as specified and directed.
Taking out sluice valves of size 150 mm, re-facing, re-grinding, replacing checknut and re-fixing complete all as specified and directed.
Taking out sluice valves of size 200 mm, re-facing, re-grinding, replacing checknut and re-fixing complete all as specified and directed.
S&F in replacement for gun metal globe or gate valve 50 mm bore with iron wheel head screwed both ends for pipe line and fixing complete all as specified and directed.
S&F in replacement for gun metal globe or gate valve 40 mm bore with iron wheel head screwed both ends for pipe line and fixing complete all as specified and directed.
S&F in replacement for gun metal globe or gate valve 25 mm bore with iron wheel head screwed both ends for pipe line and fixing complete all as specified and directed.
S&F in replacement for gun metal globe or gate valve 20 mm bore with iron wheel head screwed both ends for pipe line and fixing complete all as specified and directed.
S&F in replacement for gun metal globe or gate valve 15 mm bore with iron wheel head screwed both ends for pipe line and fixing complete all as specified and directed.
Taking out water meter with spigot and socket bore of pipes in 150 mm connecting pieces, including burning out to lead joints complete all as specified and directed.
Taking out water meter with spigot and socket bore of pipes in 100 mm connecting pieces, including burning out to lead joints complete all as specified and directed.
Taking out water meter with spigot and socket bore of pipes in 80 mm connecting pieces, including burning out to lead joints complete all as specified and directed.
M&L in replacement of water meter bore of pipe in 150 mm with flanged joints, including removal of flanged connecting piece, or blank flange a length of flanged connecting pipe (or two blank flanges) and labour only for two flanged joint complete all as specified and directed.
M&L in replacement of water meter bore of pipe in 100 mm with flanged joints, including removal of flanged connecting piece, or blank flange a length of flanged connecting pipe (or two blank flanges) and labour only for two flanged joint complete all as specified and directed.
M&L in replacement of water meter bore of pipe in 80 mm with flanged joints, including removal of flanged connecting piece, or blank flange a length of flanged connecting pipe (or two blank flanges) and labour only for two flanged joint complete all as specified and directed.
S&F in replacement of CI foot valve, flanged end and drilled of size 150 mm dia ISI Mark complete all as specified and directed
S&F in replacement of CI foot valve, flanged end and drilled of size 100 mm dia ISI Mark complete all as specified and directed
S&F in replacement of Metalic foot valve, flanged end and drilled of size 80 mm dia ISI Mark complete all as specified and directed
M&L for cutting of road, hard standing made of concrete or premix carpet, suitable for soiling and morrum filling including excavation for laying of pipe upto 150 mm dia, all as directed and making repair to potholes any depth, n.exc 1 Sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc, cutting around edges to at least 25 mm in depth, making good by filling in screened & graded roadmetal, watering and well ramming (including supply of road metal) complete all as specified and directed.
Dismantling of existing valve pit and M&L for construction of masonry valve pit with the following specification :- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200 x1200 mm, 150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40 x 40 x 5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
Dismantling of existing valve pit and M&L for construction of masonry valve pit with the following specification :- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 900 x 900 x 1200 mm, 150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40 x 40 x 5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
S&F structural steel section support for covering valve pit along with angle bracing, support clamps and back plates fabricated including nuts, bolts, washers, welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated and also provide T for operating of the Valve as required length or directed including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for replacment of unserviceable ball valve and S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed (minimum weight -142gms/ 20mm-210 gms./25mm-455gms/ 40mm - 690 gms/50mm) GI fittings such as elbow, nipple etc for the following sizes complete all as specified and directed :-
All as per item srl No. 78 above but size 25 mm bore complete all as specified and directed.
All as per item srl No. 78 above but size 40 mm bore complete all as specified and directed.
All as per item srl No. 78 above but size 50 mm bore complete all as specified and directed.
Suply and lay in replacement of 3-layer PP-R Polypropylene random copolymer) concealed pipes of 16 mm dia SDR 7.4 of (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
Suply and lay in replacement of 3-layer PP-R Polypropylene random copolymer) concealed pipes of 20 mm dia SDR 7.4 of (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
Suply and lay in replacement of 3-layer PP-R Polypropylene random copolymer) concealed pipes of 25 mm dia SDR 7.4 of (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
S&F in replacement of PPR Gate Valves (Brass Insert) of 20 mm bore complete all as specified and directed.
S&F in replacement of PPR Gate Valves (Brass Insert) of 25 mm bore complete all as specified and directed.
Making connection of PP-R distribution branch with PP-R main of 16 to 40 mm sizes by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Taking up submersiblepPump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 25/22.5/20 HP Pump Set . (i) Transportation of submersible pump - motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase, taking out burnt winding wire, with & including rewinding PVC insulated water proof copper wire with using winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, including cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing. (iv) disconnection of electric connection from LT control panel & starter of submersible pumping set & reconnecting with existing pipe and making electrical connection with panel board & starter complete all as specified and directed.
Taking up submersible pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set. (i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase, taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, including cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing. (iv) disconnection of electric connection from LT control panel & starter of submersible pumping set & reconnecting with existing pipe and making electrical connection with panel board & starter, complete all as specified and directed.
Taking up submersible pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 12.5/10 HP Pump Set. (i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase, taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, including cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing. (iv) disconnection of electric connection from LT control panel & starter of submersible pumping set & reconnecting with existing pipe and making electrical connection with panel board & starter complete all as specified and directed.
Taking out of centrifugal pump set 125/75 HP from pump foundation after disconnection from motor and transportation to workshop, dismantling the pump for repair/ overhauling including cleaning of all parts of pump assembly throughly, including machine work of pump shaft inorder to obtain smooth finish including necessary polishing etc and installing back including helium gasket sheet not less then 1mm thick & to the entire satisfaction of Engr-in-Charge complete all as specified and directed. Note :- (i) Spare parts as required shall be measure & paid seperately against the relevant items. (ii) Make/Size of spare parts of centrifugal Pump Set shall be as per existing centrifugal pump set. (iii) Cost of fixing of spare parts shall be incuded in the quoted rate of this item.
Supply only Casing Wear Ring complete all as specified and directed.
Supply only shaft sleeve complete all as specified and directed.
Supply only Inter Stage Ring complete all as specified and directed.
Supply only Ball bearing SKF-7310/NU411 complete all as specified and directed.
Supply only Ball bearing SKF - 6310 C3 -/6311 complete all as specified and directed.
Supply only bearing cartridge DE complete all as specified and directed.
Supply only bearing cartridge NDE complete all as specified and directed.
Supply only shaft sleeve nuts complete all as specified and directed.
Supply only Split Gland complete all as specified and directed.
Taking out of centrifugal pump set 60/50/30/15 from pump foundation after disconnection from motor and transportation to workshop, dismantling the pump for repair/ overhauling incluiding cleaning of all parts of pump assembly throughly, including machine work of pump shaft inorder to obtain smooth finish including necessary polishing etc and installing back including helium gasket sheet not less then 1mm thick & to the entire satisfaction of Engr-in-Charge complete all as specified and directed. Note :- (i) Spare parts as required shall be measure & paid seperately against the relevant items. (ii) Make/Size of spare parts of centrifugal Pump Set shall be as per existing centrifugal pump set. (iii) Cost of fixing of spare parts shall be incuded in the quoted rate of this item.
Supply only Casing Wear Ring complete all as specified and directed.
Supply only shaft sleeve complete all as specified and directed.
Supply only Inter Stage Ring complete all as specified and directed.
Supply only Ball bearing SKF - 6306/6307 complete all as specified and directed.
Supply only Ball bearing SKF - 6309/6310/6312 C3 complete all as specified and directed.
Supply only Bearing cartridge DE complete all as specified and directed.
Supply only Bearing cartridge NDE complete all as specified and directed.
Supply only shaft sleeve Nuts complete all as specified and directed.
Supply only Split Gland complete all as specified and directed.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 Phase, 415 Volts, 50 Cycles and taking out to local workshop induction motor 125/75 HP for repair purpose including complete cleaning, varnishing, reinsulation and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note:- Rewinding shall be measure & paid seperately under relavant item.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 Phase, 415 Volts, 50 Cycles, and taking out to local workshop induction motor 60/50/40 HP for repair purpose including complete cleaning, varnishing, insulation and greasing and including shifting back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note- Rewinding shall be measure & paid seperately under relavant item.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 Phase, 415 Volts, 50 Cycles, and taking out to local workshop induction motor 15/7.5 HP for repair purpose including complete cleaning, varnishing, insulation and greasing and including shifting back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note- Rewinding shall be measure & paid seperately under relavant item.
M&L for rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations complete all as specified and directed. Make : Atlas/BWC/Swastik/Chetak
S&F in replacement Fully Automatic Star Delta Motor starter 125 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415Volt, 50Hz, 3-Ph) and Relay Range 66-110 complete all as specified and directed. Make : L&T cat no SS90923 or Equivalent of SIEMENS/schneider.
S&F in replacement Fully Automatic Star Delta Motor starter 75 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415Volt, 50Hz, 3-Ph) and Relay Range 45-75 complete all as specified and directed. Make : L&T cat no SS90913 or Equivalent of SIEMENS/schneider.
S&F in replacement Fully Automatic Star Delta Motor starter 60HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415Volt, 50Hz, 3-Ph) and Relay Range 42-63 complete all as specified and directed. Make : L&T cat no SS 91730 or Equivalent of SIEMENS/schneider.
S&F PVC Insulated unsheathed submersible cable 10 Sqmm dia three core multistranded bright annealed copper conductor 1100 Volts, including taking down conf to IS-694 complete all as specified and directed.
S&F PVC Insulated unsheathed Submersible cable 16 sqmm dia three core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified.
Repair and maintainance of Altoch GP Dosing System of 100 litres with following specifications:-Doser pump 0.9 Amp, 250 Volts 100psi, Doser motor 0.8 Amp, 220 Volts, PVC pipe connection inlet to Doser and outlet to Doser, cleaning of Doser tank, all as per required and directed by Engr-in-Charge. Note:- Defective items if replaced shall be measured and paid under relavent item.
Supply only chemical dosing pump suitable for 100 Ltrs Dosing system complete all as specified and directed.
Supply only electric motor suitable for 100 ltrs Dosing system complete all as specified and directed.
Supply only nozzle injector suitable for 100 ltrs Dosing system complete all as specified and directed.
Supply only electric stirrer suitable for 100 ltrs Dosing system complete all as specified and directed.
Supply only suction lance with foot valve suitable for 100 ltrs Dosing system complete all as specified and directed.
Supply only suction PVC pipe suitable for 100 ltrs Dosing system complete all as specified and directed.
S&F in replacement mono block pump 0.5-1 HP, single Phase 230 Volt 1200 RPM, 50 Hz for busting of water supply with GI pipe fittings complete all as specified and directed.
M&L for replacement of aluminium strip 25 x 3.15mm with saddles and fixing screws etc. mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed.
M&L for trimming vegetation or small inequalities clearing all grass vegetation, saplings, shrubs, brushwood, roots inside the sump or valve pits, and tree of surroundings area including and removing rubbish upto a distance of 50 meters outside the periphery of the area under clearance of water supply installations and Sumps complete all as specified and as directed.
M&L for draining water from OHT up to 50000 gallon capacity reservoirs n.exc 18 m head/staging, and cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance n.exc 50 m including one coat of synthetic enamel paint on all steel surfaces such as ladder, railing, inlet & over flow CI pipes connected sluice valves of the respective OH tanks reservoir etc writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed by Engr-in-Charge.
M&L for draining water from semi underground reservoir/sump up to 100000 gallon capacity reservoirs and cleaning internal portion of sump (bottom and walls) by means coir / wire brush etc and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance n.exc 50m including one coat of synthetic enamel paint on all steel surfaces such as inlet & over flow CI pipes connected sluice valves of the respective ground level reservoir etc writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed by Engr-in-Charge.
Taking out burnt and unserviceable submersible pump from borewell and S&F in replacment, testing and commissioning of submersible pumps 415 Volts, three Phase system of size 15 HP( KS6B-1502), LPM 120 to 170 LPM Head 90 to 130m capacity 50 Hz, 8 to 12 stage with delivery size upto 80 mm suitabelfor 6 " to 8" bore complete all as specified and as directed. Note : Unserviceable pump shall be deposites to E/M store.
S&F Chlorine Testing Kit by Orthotolidine method with all accessories (colour matching PPM tubes, water testing tubes, Orthotolidine solution and wooden Box) complete all as specified and directed.
Testing of borewells water with following test to be done and certified by authorised government central/state agencies:-TDS,Chloride,Floride,Alkaline,E-COLI (bacteriological test).
Taking down unserviceable /burnout geyser storage type of capacity 25 Liters and dismantling and deposite to E/M store complete all as specified and directed.
S&F in replacement of electric water heater storage type steel/plastic outer body and stainless steel inner tank with Feroglas technology/Glass bic watering on it and heating element upto 2 KW, capacity 25 Ltrs, BEE 5 star rated with all accessories such as safety valve, thermostat, NRV connection piece etc complete all as specified and dircted.
S&F in replacement indication lamp suitable for geysers of capacity upto 25/15 Liters of any description such as round/rectangular complete all as specified and directed.
S&F in replacement geysers heating element round/tringle 2KW 240 Volt complete all as specified and directed.
S&F in replacement syphon assembly complete with inter thermostate pipe etc and screw rubber packing for 25 Liters capacity as per existing sample complete all as specified and directed.
S&F in replacement thermostate switch for geysers with temperature range 25 degree centigrade to 85 degree centigrade, 11" long, for geyser of capacity 25/100 Litres complete all as specified and directed.
S&F in replacement copper chromium plated CP connection 18" long with two brass adopter heavy duty ISI marked & connecting, for geyser of capacity 25/35 Litres complete all as specified and directed.
S&F in replacement safety valve/high pressure valve 15mm, as per side requirement for geyser of capacity 25 Litres complete all as specified and directed.
S&F in replacement of metal plug top 2 pole and earth 240 Volts complete all as specified and directed.
S&F in replacement of metal socket 2 pole and earth 240 Volts complete all as specified and directed.
S&F in replacement PVC connection with brass adopter screwed at both ends 18" long heavy duty ISI marked complete all as specified and directed.
S&F in replacement of new wave 11.81" Alumimium Grip Connection pipe 12" premium quality for geyser of capacity 25 Litres complete all as specified and directed.
Taking down geyser storage type of capacity 35/25 Liters and dismantling the complete accessories cleaning of inner copper tank outlet/inlet tubes, by cleaning material Vinegar the inside of a geyser remove the corrosion and rusting from anode rod reassembling and refixing complete after repair complete all as specified and directed. Note : (i) The accessories if replaced, shall be paid under respective item separately. (ii) Any damage if occurred during the process of cleaning the geysershall be made good by contactor at no extra cost.
Schedule of credit amount of Rs. 2,48,589.00 to be deducted during AOC
SONAL CONSTRUCTION AND ENGINEERS
SR ASSOCIATES
LAL SINGH & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .