| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAdmitted-Finance | ₹17.0 L | L1 | Admitted-Finance |
| 2 | L2₹20.1 LAdmitted-Finance | ₹20.1 L | L2 | Admitted-Finance |
| 3 | Not Admitted-PreQual/Technical | - | - | Not Admitted-PreQual/Technical EMD/Fee not received |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified. |
| Sl No | Description | Qty | Unit | annapurna construction L1 | PARSHWA BUILDERS L2 |
|---|---|---|---|---|---|
| 1.00 | Management and maintenance of the sewage treatment plants of capacity 200KLD & 500KLD located at RRCAT campus by deploying one no. of skilled operator cum sweeper in general shift i.e. cleaning of screen chamber, chlorine refilling, daily monitoring of pumps, monitoring of sludge in balancing tanks, V Notch cleaning, cleaning of planted granular filter with proper safety tools & tackles etc. complete as per specifications and as directed by Engineer in charge.: In case non availability of deployed person, the recovery shall be made @ Rs. 1000/day at the time of execution of work. | 12 | Monthly | 51,000 ₹6,12,000 | 42,000 ₹5,04,000 Lowest |
| 2.00 | Earthwork excavation in foundations in all soils other than soft and hard rock by mechanical means (hydraulic Excavator)/manual means upto a depth not exceeding 1.5 m. including shoring and dewatering, if necessary and refilling around foundations and in plinth with selected excavated earth, in layers not exceeding 250mm thick, consolidating etc., and disposing surplus earth within a distance of 50 metre lead. (Depth of excavation shall be measured from the existing average ground level.) etc. complete as per drawing, specifications and as directed by Engineer-in-charge. | 10 | Cum | 400 ₹4,000 | 350 ₹3,500 Lowest |
| 3.00 | Excavation in Trenches, for pipes and sewers in all soils except soft and hard rock by mechanical means (hydraulic Excavator)/manual means upto a depth not exceeding 1.5m including shoring and dewatering if necessary and refilling in trenches with selected excavated materials in layers not exceeding 25cm. consolidating etc. and disposing the surplus earth within a distance of 50m.complete . as per drawing, specifications and as directed by Engineer-in-charge. | 10 | Cum | 500 ₹5,000 | 350 ₹3,500 Lowest |
| 4.00 | Monthly visits by senior engineer to inspect works like smooth functioning of STP including screen chamber , Settler.I, settler.II, Balancing tank work performance , vortex tube, vortex pump , Planted granular filter , Chlorine dozing pump working , working of Electrical panel , chlorine refilling status, pump monitoring, sludge monitoring, V Notch working with proper safety tools & tackles etc. complete as per specifications and as directed by Engineer in charge.. Note: In case non availability of deployed person, the recovery shall be made @ Rs. 2000/day at the time of execution of work. | 12 | Monthly | 4,400 ₹52,800 | 3,000 ₹36,000 Lowest |
| 5.00 | Servicing, maintenance and repair of all electro-mechanical items such asVortex feed pump, Chemical dozing pump including pumps panel , cables, pipes, screen level sensor automation, Stainless steel impeller of pumps, condensor of motor, pumps. panel, cables, pipes, screen, vortex tube, level sensors including all PH fittings and fixtures as and when required for smooth functioning of STP with proper safety tools & tackles etc. complete as per specifications and as directed by Engineer in charge. . | 12 | Monthly | 8,500 ₹1,02,000 Lowest | 10,000 ₹1,20,000 |
| 5.10Note: measurement shall be taken on per month basis. this item includes Servicing, maintenance and repair of all items including labour, freight etc. | |||||
| 6.00Complete Rewinding of all three phases winding of four pole induction motor by using suitable super enameld copper wire, class "F" insulation, varnish of preferred make etc. as per standard procedure which includes proper handling, cutting and removing of old copper coils, cleaning of slots, placing of coils as original and thier interconnections, heating and varnishing, replacement of bearings, painting of motor body, testing of motor on no load. Waranty of rebound motor will be minimum Six months. The old winding copper shall be retained by connector and transporation of motor to and fro will be in contracto's scope. | |||||
| 6.10 | UP to 5 HP 4 pole three phase induction motor | 15 | Each | 2,900 ₹43,500 Lowest | 8,000 ₹1,20,000 |
| 6.20 | 16 HP to 20 HP 4 pole three phase induction motor | 1 | Each | 12,000 ₹12,000 Lowest | 22,000 ₹22,000 |
| 6.30 | 21 HP to 30 HP 4 pole three phase induction motor | 1 | Each | 28,000 ₹28,000 Lowest | 35,000 ₹35,000 |
Tender Value
₹16.1 L
EMD Value
₹32,100
Closing Date
7 May 2026, 3:30 pmClosed
CHIEF ENGINEER, RRCAT, INDORE
CSD OFFICE RRCAT INDORE
Management and upkeep of 500KLD sewage treatment plant located near MPS in colony area and 200KLD sewage treatment plant in technical area of RRCAT Indore.
2026_RRCAT_906120_1
RRCAT/CSD/W-4393/2026/84
Open Tender
Civil Works
Item Rate
365 days
RRCAT
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹32,100
28 Jul 2026
22 Apr 2026
12 May 2026
23 Apr 2026
7 May 2026
23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Management and maintenance of the sewage treatment plants of capacity 200KLD & 500KLD located at RRCAT campus by deploying one no. of skilled operator cum sweeper in general shift i.e. cleaning of screen chamber, chlorine refilling, daily monitoring of pumps, monitoring of sludge in balancing tanks, V Notch cleaning, cleaning of planted granular filter with proper safety tools & tackles etc. complete as per specifications and as directed by Engineer in charge.: In case non availability of deployed person, the recovery shall be made @ Rs. 1000/day at the time of execution of work. | - | Monthly | - | - |
| 0.0 | Earthwork excavation in foundations in all soils other than soft and hard rock by mechanical means (hydraulic Excavator)/manual means upto a depth not exceeding 1.5 m. including shoring and dewatering, if necessary and refilling around foundations and in plinth with selected excavated earth, in layers not exceeding 250mm thick, consolidating etc., and disposing surplus earth within a distance of 50 metre lead. (Depth of excavation shall be measured from the existing average ground level.) etc. complete as per drawing, specifications and as directed by Engineer-in-charge. | - | Cum | - | - |
| 0.0 | Excavation in Trenches, for pipes and sewers in all soils except soft and hard rock by mechanical means (hydraulic Excavator)/manual means upto a depth not exceeding 1.5m including shoring and dewatering if necessary and refilling in trenches with selected excavated materials in layers not exceeding 25cm. consolidating etc. and disposing the surplus earth within a distance of 50m.complete . as per drawing, specifications and as directed by Engineer-in-charge. | - | Cum | - | - |
| 0.0 | Monthly visits by senior engineer to inspect works like smooth functioning of STP including screen chamber , Settler.I, settler.II, Balancing tank work performance , vortex tube, vortex pump , Planted granular filter , Chlorine dozing pump working , working of Electrical panel , chlorine refilling status, pump monitoring, sludge monitoring, V Notch working with proper safety tools & tackles etc. complete as per specifications and as directed by Engineer in charge.. Note: In case non availability of deployed person, the recovery shall be made @ Rs. 2000/day at the time of execution of work. | - | Monthly | - | - |
| 0.0 | Servicing, maintenance and repair of all electro-mechanical items such asVortex feed pump, Chemical dozing pump including pumps panel , cables, pipes, screen level sensor automation, Stainless steel impeller of pumps, condensor of motor, pumps. panel, cables, pipes, screen, vortex tube, level sensors including all PH fittings and fixtures as and when required for smooth functioning of STP with proper safety tools & tackles etc. complete as per specifications and as directed by Engineer in charge. . | - | Monthly | - | - |
| 0.0 | Complete Rewinding of all three phases winding of four pole induction motor by using suitable super enameld copper wire, class "F" insulation, varnish of preferred make etc. as per standard procedure which includes proper handling, cutting and removing of old copper coils, cleaning of slots, placing of coils as original and thier interconnections, heating and varnishing, replacement of bearings, painting of motor body, testing of motor on no load. Waranty of rebound motor will be minimum Six months. The old winding copper shall be retained by connector and transporation of motor to and fro will be in contracto's scope. | - | - | - | - |
| 0.9 | UP to 5 HP 4 pole three phase induction motor | - | Each | - | - |
| 0.0 | 16 HP to 20 HP 4 pole three phase induction motor | - | Each | - | - |
| 0.9 | 21 HP to 30 HP 4 pole three phase induction motor | - | Each | - | - |
| 0.0 | Supply of chlorine to Dozing pump 150 Litres of chlorine, with concentration of 11% with proper safety tools & tackles etc. complete as per specifications and as directed by Engineer in charge. | - | Job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.74 MB
specificationforPHworks.pdf
Tender Documents • 1.40 MB
specificatioofSTP.pdf
Tender Documents • 0.78 MB
BOQ_952429.xls
BOQ • 0.29 MB
NIT.pdf
Tender Documents • 0.72 MB
CCC.pdf
Tender Documents • 1.89 MB
listofmake.pdf
Tender Documents • 0.28 MB
ScheduleB.pdf
Tender Documents • 0.55 MB
SGF.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].