Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.2 L+₹58,633.05 (1.26%)Rejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹48.7 L+₹2.1 L (4.59%)Rejected-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L3 | Rejected-AOC Rejected | |
| 4 | L3₹48.7 L+₹2.1 L (4.59%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 5 | L4₹49.2 L+₹2.6 L (5.53%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
16 Jan 2021, 6:00 pmClosed
Garrison Engineer (M) NAS Arakkonam
Garrison Engineer (M) NAS Arakkonam-631006
ADDITION ALTERATION TO INFILTRATION WELL PUMPING STATION AT THIRUPARKADAL AND PROVISION OF HARD STANDING FOR FOUR WHEELER PARKING AT SICK BAY AND ACCOMMODATION OFFICE AT ARAKKONAM
2020_MES_408032_1
8960E8
Open Tender
Civil Works
Item Rate
150 days
Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (M) NAS Arakkonam
₹91,000
Yes
23 Jan 2021
2 Jan 2021
19 Jan 2021
2 Jan 2021
16 Jan 2021
8 Jan 2021
4 Jan 2021 - 7 Jan 2021
Amount
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each with shutters (without taking off shutters from the frame) and removal from site complete all as specified and as directed.
M & L for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and as directed.
S & F mild steel works as in window guard bars, plain, let in and fixed independently in frames, etc and similar articles conforming to Fe-290 Gde E-165 etc complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones exc 1.5 Sqm etc complete all as specified and as directed.
M & L for 4mm Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F for 1.00mm thickness Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete push pull or manual type etc complete all as specified and as directed.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Demolition of cement concreteof any description and in any position not otherwise specifically provided for complete all as specified and as directed
Removing building materials etc. to a distance of 1.5Km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and as directed.
M&L Providing, cement concrete 1:3:6, type C1 using 20mm graded aggregate in roof padding with WPC fosroc SP 430 of M/S Fosroc chemical @ 250ml per 50Kg of cement, of varying thickness to maintain required slope minimum thickness being 20mm complete all as specified and as directed. (Note: WPC shall be measured and paid separately)
Supply only WPC fosroc SP 430 all as specified and directed by Engineer-In-Charge complete all as specified and as directed.
M&L 5mm thick cement Screed in cement mortar 1:4 with water proofing compound at 2% by weight of cement or as per manufaturer instruction will be applied on surface to have a smooth surface for laying of water proofing membrane complete all as specified and as directed. (Note: WPC shall be measured and paid separately)
Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and as directed.
M&L APP based polymeric membrane minimum weighing 3kg / sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms / sqm) laid on primed surface by forced application complete all as specified and as directed.
M&L for applying a coat of bituminous aluminium primer at 0.10 kg/Sqm as weather proof coat all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).
S&F 110mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F 75mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F 110mm PVC (SWR) bends any radius with access door complete all as specified and as directed.
S&F 110mm PVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and as directed.
S&F 75mm PVC (SWR) vent cowl complete all as specified and as directed.
S & F for 250 litre Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of water tanks and removing to store complete all as specified and as directed.
S & F in repair 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 20mm Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 15mm Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F in repair 15mm chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed .
S&F in repair 15mm Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified and as directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
Supply and fix in repairs tubular towel rail brass chromium plated, 20mm dia D type, 60 cm long between flanges complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs vitreous squatting pan orissa pattern, size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connnection to trap and to flushing pipe, antisyphonage pipe etc., complete including making good to floor complete all as specified and as directed.
Supply and fix in repairs PVC valveless, syphonic action, flushing cistern low level 10 ltrs capacity, white with inlet ball valve float and handle including brackets and flush pipe of polyethylene of low or high quailty PVC 32 mm dia complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in with CM 1:6 complete all as specified and as directed.
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed by Engr-in-charge.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:6, finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in two layers 10mm thick in CM 1:4 followed by 5mm thick CM 1:4 with approved WPC, finished even and fair complete all as specified and as directed.
M&L Integral waterproofing compound complete all as specified and as directed.
M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:3, finished even and smooth (without using extra lime or cement) on ceiling complete all as specified and as directed.
M&L Preparing new plastered surfaces and applying three coat of white wash on walls complete all as specified and as directed by Engr-in-charge.
M&L Preparing new plastered surfaces and applying three coat of white wash on ceiling complete all as specified and as directed by Engr-in-charge.
M&L Complete removal of existing treatment on old plastered surfaces and applying three coat of white wash on walls complete all as specified and as directed.
M&L Complete removal of existing treatment on old plastered surfaces and applying three coat of white wash on ceiling complete all as specified and as directed.
M&L Preparing new plastered surfaces and applying two coat of Acrylic emulsion paint (Matt finish) over a coat of primer surfaces of walls complete all as specified and as directed.
M&L Complete removal of existing treatment on old plastered surface and applying two coat of Acrylic emulsion paint (Matt finish) over a coat of primer surfaces of walls and over projected surfaces of parapet/ column/ beams/ facia of chajjas complete all as specified and as directed.
M&L Surfaces of any description, over 10cm in width or girth,not otherwise described of old steel surface and one coat of synthetic enamel (ordinary tint) complete all as specified and as directed.
Material and labour for precast cement concrete type B1 1:2:4 (20mm graded aggregate) Providing precast cement concrete in but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces. and setting in mortar 1:4 complete with joints to match complete all as specified and as directed.
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
all as per item No. 51 here-in-above but 5mm dia and over upto and including 10mm dia as in stirrups.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Material and labour for cement concrete type D2 1:4:8, (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed.
Material and labour for cement concrete type D2 1:4:8, (using 40mm graded stone aggregate) in surface channels and drains complete all as specified and as directed.
Material and labour for Concrete bed to 100mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in type D-2 1:4:8 complete all as specified and as directed.
M & L for Extra for forming fair finished drain or channel 25 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in coping including necessary form work etc., complete all as specified and as directed.
Supply of broken brick aggreagate for loose filling, of gauge 40 mm to 80 mm graded complete all as specified and as directed.
Supply and fix for hume pipe for septic tank of upto 10 users of 600mm dia complete all as specified and as directed.
Material and labour for Moorum / red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Demolition of unreinforced Cement concrete is ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 50mm Cement concrete type C- 1, 1:3:6 (20mm graded aggregate) as in plinth protection Finishing surface even and fair without using extra cement complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the permises etc., complete all as specified and as directed.
M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:4 complete all as specified and as directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Material and labour for chequred cement concrete tiles 300x300x20-22mm thick set, jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed.
Demolition of reinforced Cement concrete in above ground floors exc 15 cm thickness (below or above ground level) etc complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry built in cement mortor including all quoins, arches, pillars etc., but excluding ashlar facing dressed stone work and precast concrete articles built in cement mortor etc complete all as specified and as directed.
Material and labour for reinforced cement concrete (design mix) in foundations, including rafts, footings, foundation beams; plinth beam; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete type M30 (using 20mm graded aggregate) complete ll as specified and as directed.
Material and labour for reinforced cement concrete (design mix) in columns, pillars, piers, posts and struts with M30 (20mm graded aggregate) complete ll as specified and as directed.
Material and labour for reinforced cement concrete (Design mix) in Beams, cantilevers, bressummers, lintels over 1.5m span with M30 (20mm graded aggregate) complete ll as specified and as directed.
Material and labour for reinforced cement concrete (design mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like with M30 (20mm graded aggregate) complete ll as specified and as directed.
Material and labour for precast cement concrete 1:2:4, type B1 (20mm graded aggregate) Providing precast cement concrete in but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces. and setting in mortar 1:4 complete with joints to match complete ll as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams; and similar work, vertical or to be batter curved rough finished surface all as specified and as directed.
Formwork to square, rectangular on plan of pillars, posts, struts, piers, columns and stanchions all as specified and as directed.
Formwork to sides and soffits of floor or roof curved beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. all as specified and as directed.
Formwork to sides and soffits of floor or roof flat beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick fair finished surfaces.
M&L Preparing new plastered surfaces and applying two coat of cement paint over a coat of primer on wallsetc complete all as specified and as directed.
Dismantling post or struts (wood, steel or RCC) any section including embeded portion in concrete complete all as specified and as directed.
Material and labour for precast reinforced cement concrete type B1 1:2:4 (Using 20mm graded stone aggregate) as in fencing posts or terminal posts struts etc., with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and as directed. Note:- Rate is inclusive of form work etc as required.
Dismantling of fencing wire mesh any type complete all as specified and as directed.
Fixing only chain link fencing including line wire, any mesh type of standard rails straining bolts etc., including provision of binding wire complete all as specified and as directed. Note: Chain link mesh shall be supplied and measured under relevant item of schedule.
Supply only chain link mild steel galvanised fencing n.exc 4 Kg/ sqm wt of any size and any type complete all as specified and as directed.
Supply and fix for mild steel flat iron fills for securing wire mesh etc., including all necessary drilling, bolting or reverting etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply and fix for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends fitted with washers and hexagonal exc 10cm and n.exc 15cm long and dia of shank of 11 to 15 mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs galvanised iron, 2 strand, steel barbed wire 2.24 mm dia, barbed with 2mm dia barbs at 75mm spacing straining and fixing to any type of standard rails straightening bolts including securing of tying at crossings with and pran of galavanished mild steel wire complete all as specified and as directed.
Material and labour for Round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde.E-250) Part- I quality-A complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-charge.
Material and labour for framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forgeted into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 complete all as specified and as directed by Engr-in-charge.
Surface excavation not exc 30 cms deep and averaging 15 cm deep and getting out soft/ loose soil complete all as specified and as directed by Engr-in-charge.
Material and labour for 150mm consolidated thick granularsub base with Kankar or laterite, spred, rolled and consolidated to gradient and camber required complete all as specified and as directed.
Material and labour for hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface broken stone boulders complete all as specified and as directed.
Material and labour for cement concrete 1:3:6 , type C- 2, (using 40mm graded stone aggregate)100mm thick sub bases, sub floors, floor pavings, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) 100mm thick in fllors laid in alternate bays of size etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix PVC dividing strips, inserted in position, conform to design, 100mm wide strip complete all as specified and as directed by Engr-in-charge.
Removing excavated material soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:2:4 type B 1 (Using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed by Engr-in-charge.
Material and labour for walling random rubble, brought upto courses well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exc 40mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses; complete all as specified and as directed by Engr-in-charge.
Material and labour for flush pointing to random rubble mansonry, uncoursed or brought upto courses in CM 1:4 complete all as specified and as directed by Engr-in-charge.
Material and labour for old size brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redius built in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Material and labour for old size brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
Excavating over areas, n exc 1.5 m deep and getting out in soft / loose soil complete all as specified and as directed
M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed
M & L for Plain Cement concrete 1:2:4 Type B1(20 mmm graded aggregate) as in stops,plinth courses similar works complete all as specified and as directed
M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base15 mm thick with CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
M& L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with 10 mm thick Plastering with CM 1:4 complete all as specified and as directed
M & L 20mm thick Granite (of any type)tiles machine cut, in skirting/dado laid over cement screed 15 mm thick with CM 1:6 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete
M & L for lifting and lowering of submersible motor (2 Nos) including column pipe 75mm from infiltration well and relaying the same as specified and as directed.
Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed.
Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :-
One light point point controlled by one switch.
One fan point controlled by one switch.
One Exhaust fan point controlled by one switch.
One 3 pin socket outlet 5 Amps, indipendent board with cables 1.5 Sqmm size.
All as per item ser no-96 above here in before but one 3 pin socket outlet 5/15 Amps, indipendent board with cables 4.0 Sqmm size.
Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into including PVC concealed (fixed on wall/roof/ceiling etc), conduit of size not less than 20 mm dia and including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :-
One light point point controlled by one switch.
One 3 pin socket outlet 5 Amps, indipendent board with cables 1.5 Sqmm size.
All as per item ser no-97 above here in before but one 3 pin socket outlet 5/15 Amps, indipendent board with cables 4.0 Sqmm size.
M&L for sub main wiring for phase and neutral with PVC FRLS insulated unsheathed multi stranded along with earth wire FRLS PVC insulted copper conductor, single core cable in and including surface/concealed /PVC conduit of appropriate size 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire Note:- : 1. Cutting chases for concealed wiring shall be measured and paid seperately. 2. Rates are including taking down old unserviceable.
S&F for switch piano, flush type single pole , one way 5 amp as specified and as directed by Engr-in-Charge
S&F for switch socket combination 2 in 1, 3 pin, 5 Amp flush type as specified and as directed by Engr-in-Charge
S&F for switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal as specified and as directed by Engr-in-Charge
S&F for ceiling rose three terminals/ PVC/ polycarbonate, isolated body as specified and as directed by Engr-in-Charge
S & F stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc all as specified and as directed by Engr-in-Charge
Supply and fix high efficiency wall mounted LED batten type 18/20W 4 ft LED light fitting incl taking down old fittings complete all as specified and as directed by Engr-in-Charge
Supply and fix high efficiency wall mounted LED batten type 9/10W 2 ft LED light fitting incl taking down old fittings complete all as specified and as directed by Engr-in-Charge
Supply and fix 230 V, ceiling fan of 1200mm sweep smart saver-50 of Orient or equivalent of Crompton /Bajaj/Usha
S&F MCB,DB SPN 8 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.
Supply and fix for MCB SPN 230 V, 63 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.
Supply and fix of heavy duty exhaust fan with louvers ,300 mm sweep, AC, single phase, 230 volts including necessary fixing arrangement such as Bolts and nuts etc and making good the distrubed surface complete all as specified.
supply and erect cable tray size 300 mm (W) X 80 mm (H) X 3 mm (T) made up of perforated hot dip galavanized iron sheet duly powder coated with coupler plates tee horizontal bend etc with coupler plates,tee,horizontal bend,vertical,etc with neccessery arrangements to fix on wall complete all as specified and as directed.
Supply and fix Energy saving not less than 25 Watts LED light fitting ,powder coated pressure die cast aluminium high power street light with heatresisant toughened glass with lens by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two nos made out of 25x3 mm FI incl two coat of synthetic enamel paint over a coat of red oxide primer, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm from ceiling rose to fitting all as specified.
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface and old corroded item all as specified and as directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade, cross sectional area 95 sq. mm 3.5 core with stranded aluminium conductor including glands,connecting materials etc complete all as pecified and direceted as directed.
Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm including 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4)type B-1cover and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
M&L for cutting chases on brick walls concrete surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishes all as directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed. Make -: POLYCAB /FINOLEX/ PLAZA /Havells / KEI.
All as per item No139 above but 25 sqmm 4core complete all as specified and as directed by Engr-in-Charge. Make -: POLYCAB /FINOLEX/ PLAZA /Havells / KEI.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr deep getting out in soft /loose soil for laying cable / erection of poles complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5mtr wide & exceeding 1.5 mtr deep getting out in soft /loose soil for erection of poles
Returning , filling in trenches in layers not exceeding 25 cm thick including spreading, levelling & well ramming including watering as required all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above from the starting point all as specified and directed
Spreading riddled earth as obtained from item No-141 here-in-before for UG cable cushioning complete all as specified and as directed. Note: if the required qty of riddled earth not obtained from above item the contractor should bring the same from other location shown (not beyond 50m) including necessary earthwork as directed for borrow pit/trench to obtain the required qty without any additional cost and the cost deemed to be included in the rate quoted by the contractor.
Supply and lay standard size well burnt bricks,Sub class 'B', laid flat, dry in trenches for cable protection complete all as specified and as directed.
Supply, fixing and testing LED flood light fitting of not less than 80 Watt, luminaire fitting of IP66 protection comprises of pressure die cast aluminium housing powder coated, toughened glass, luminaire efficiancy not less than 110 lm/w provided with surge suppressor 5 KV complete all as specified and as directed by Engr-in-charge.Make: Crompton Cat Part No. LFLN-80-CDL/ 60-M/ Surya Roshini Ltd Cat Part No. SLE FL 80W IP66 LUMOS MAX/ Philips/ Wipro. Note: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS work. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer.
M&L PVC insulated multistranded copper conductor cable 1.5 sqmm round three core 1100V grade complete all as specified and as directed by Engr-in-Charge.POLYCAB /FINOLEX/ PLAZA /Havells / KEI.
Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 65 fabricated by CPRI certified panel manufacturer including suitable terminal TPN 10 KA SMC Connector ( for 3 Phase Cable Line IN & OUT) and provision of dimrail for mounting 3 Nos MCB SP including S&F 01 No MCB 6 A SP C curve , canopy weather proof, hinged door with Two hinges, pad side locking system - 02 Nos (top and bottom), for fixing on PCC / Steel Poles in and including necessary MS Clamps - 02 Nos of suitable shape and size with nut, bolts and washers as per site requirement complete all as specified and directed by Engineer-in-charge. Note - 1) Drawing shall be approved from Deptt by the contractor before placing a order to CPRI certified panel manufacturers.
Supply and fix steel tubular swaged poles type 410 SP-31 (9 meter long) complete with CI base plate etc complete all as specified and as directed. Make: M/S India Tube Co Ltd JAMNAGAR / M/s Bharat conduit and poles co BOMBAY / M/s Jai Bharat poles MFG & ENGG CO BARODA / National tubing Bombay / M/s Calcutta poles / M/s Bombay Tubes
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed.
Material and labour for galvanized iron tubing 40mm bore light grade with all fitting laid in trenches/wall/floor/under road/culvert for protection of cable including providing fixing clamps, bolts and nuts of suitable size as required on wall all as specified. Make:TATA/Jindal/Prakash/Zenith.
SIVA ENTERPRISES
m/s SRI VALLI ENTERPRISES
SUSII CONSTRUCTIONS
N SRINIVASAN
HRML CONSTRUCTIONS
SREE BALAJI ENTERPRISES
BALA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .