Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.5 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹22.8 L+₹49,134.30 (2.20%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹24.8 L+₹2.5 L (11.1%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹25.2 L+₹2.9 L (13.2%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹25.7 L+₹3.4 L (15.4%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
9 Feb 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
SPECIAL REPAIR TO BOUNDARY WALL AROUND BLDG NO-249 AT ASTHA COMPLEX AND IMPROVEMENT OF WASHROOM OF SWO OFFICE AND DSC REST ROOM AT AF CAMP AREA NARAINA IN AOR OF GE (AF) FARIDABAD
2023_MES_632724_2
GE (FBD)/AF-62/2023-2024
Open Tender
Civil Works
Item Rate
180 days
NARAINA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹68,000
Yes
9 Apr 2024
20 Jan 2024
12 Feb 2024
20 Jan 2024
9 Feb 2024
27 Jan 2024
20 Jan 2024 - 23 Jan 2024
Amount
Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 02 above but except bricks
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) following the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of white cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engineer-in-Charge. (Payment for providing grooves shall be made separately).
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish even and smooth w/o using extra cement incl WPC @ 3% weight of cement at any height etc complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately).
Supply only liquid WPC complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying three coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrylic primer incl preparation of old/new surface and one layer of 3mm thick wall care compound of putty for exterior/interior on old scraped wall/ceiling surfaces or new plastered surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge. Note : Colour as approved by EIC
M&L for one coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl preparation of old/new surface and one layer of 3mm thick wall care compound of putty for exterior/interior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge. Note : Colour as approved by EIC
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of oil emulsion distemper over a coat of primer on surface of walls incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old steel or iron surfaces of any description not otherwise described n exc 10 cm in girth or width when unconnected with other painting or when painted in a different tint applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling / demolition and rubbish off the primises etc ccomplete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic colour tiles joint free in vertical surface 300x350x7/ 450x600x7 mm thick set andjointed in neat cement slurry and pointed in white or colour cement to match with tiles including 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting in vertical surface etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by GE.
M&L for Verified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles n. exc 0.36 sqm, in floors, skirting etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match, incl dismantling/demolition and rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge.
M&L for Verified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles n. exc 0.36 sqm, in dado , skirting etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match, incl dismantling/demolition and rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl dismantling complete all as specified and directed by Engineer-in-Charge.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and complete all as specified and directed by Engineer-in-Charge.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 sqm each and complete all as specified and directed by Engineer-in-Charge.
S&F Pressed steel frames of size 125x60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate incl filling hollow of frame with plain cement concrete type B0 (1:3:6 )(using 12.5mm graded stone aggregate ,etc complete all as specified and directed by Engineer-in-Charge.
M&L for factory made, 2nd class hard wood, 30 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass / gauge etc. (without sash bars) edges or framing plain, chamfered or rounded fitted with cut or mitered beads for securing glass etc. size of members of shutters as specified in SSR Part - I section 8.20 (a), complete all as specified and directed by Engineer-in-Charge.
S & F in repair for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed by Engineer-in-Charge.
S&F factory made 2nd class HW rail and style 30 mm thick plain, framed, paneled shutter (two panels), with lock rail and panel of 9mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
S&F in repair for factory made Solid WPC Door frame size ( 45mm X 85mm Single Rebate ) made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawings including all necessary assories complete all as specified and directed by Engineer-in-Charge. Note : The door frame should be Water Proof , Termite Proof , Fire Retardent and having excellent screw holding capacity.
S&F in repair for factory made 30mm Thick moulded WPC with decorative surface 2mm thick Moulded wood grain printed Prelam PVC sheet on front face and 2mm thk PVC sheet on back side, 100 % Solid door ( Conforming As Per IS : 4020 ) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood Grain Texture and back side palin with density not less than 600 kg/cum. Manufactured by an ISO: 9001-2015 certified company. The door should be Water Proof , Termite Proof , Fire Retardent and having screw holding capasity.Fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws incl Aluminum Jali and Stainless wiremess and other assories as per required. Material test certificate and authentication should be compulsory provided by the manufacturing company, complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium framed work for door, window / vent (powder coated) aluminium section weighting 0.55kg/RM with one or more rebated incl jointed cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium powder coated door, window and ventilator shutters, aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm thick sheet glass ordinary quality & glazing or PVC sheet joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 Nos aluminium handles 150mm, 3 x hinges, 2 x Aluminium tower bolts 150mm, 1xdoor stoper with each shutter any type complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium Anodized powder coated fixed frame of partiton or fixed window / ventilator , aluminium section weighting not less than 0.55kg/RM incl 4.8mm thick sheet glass oridinary quality ' frosted glass or ACP sheet joining with rubber beading , aluminium snap beading complete all as specified and directed by Engineer-in-Charge.
S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed by Engineer-in-Charge.
M&L for 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair complete all as specified and directed by Engineer-in-Charge.
S & F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube incl taking down old frame any type complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl taking down old shutter & 3Nos- 100mm Aluminium hinges for each shutter complete all as specified and directed by Engineer-in-Charge.
S&F for MS butt hinges, medium weight, cold rolled mild steel 100mm long (ISI Marked) with welded or complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum anodized barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum handles cast type anodized 200mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 16-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding ,rounding of edgeing complete all as specified and directed by Engineer-in-Charge.
S&F Acrylic letters (English/Hindi) 300 mm high, 50 mm width and 3 mm depth hollow wall fixed on walls fixed on wall surface or or 3mm ACP sheets board of any description using stainless steel screws of suitable size or best quality adhesive including LED module rain proof lights fittings in each letters complete all as specified and directed by Engineer-in-Charge.
Dismantling of AC/GI sheet (corrugated, semi corrugated etc) of any thickness incl ridges hips valleys as in roof coverings complete all as specified and directed by Engineer-in-Charge.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Dismantling MS works of any description complete all as specified and directed by Engineer-in-Charge.
M & L for mild steel Framed work such as grills, gratings, gates etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; nosing, framework of water tanks, band, straps, wind ties and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush down pipe) incl connection to drain and flushing pipe complete all as specified and directed by Engineer-in-Charge.
S&F PVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china urinals, half stall type (635x450mm) , complete including providing and fixing , bedding urinal against wall in cement mortar 1:2 , pointing around urinal back in cement , grating and union for discharge pipe, (inclusive of fixing supply pipe to flushing cistern, trap & waste pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair wash hand basin table top of size 600x400x175 mm vitrous China including , waste coupling & PVC waste pipe of 32 mm dia etc complete all as specified and directed by Engineer-in-Charge.
S & F for Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S& F for swan neck pillar cock fancy type chromium plated screw with iron pipe incl all fittings in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repair for wall mixturer 3 in 1 system with provision for both hand shower and overhead shower with 115 mm long bend pipe, connecting legs and wall flanges complete all as specified and directed by Engineer-in-Charge. (Without hand & overhead shower).
S&F for CP brass Centre hole mixer without pop up waste system with 450 mm long braided hoses, 20mm cartridge size for mixing hot and cold water screwed down for iron pipe for WHB, in repairs complete all as specified and directed by Engineer-in-Charge.
S&F for Brass chromium plated shower rose of 200mm size with arm and with or without swivel joints, complete all as specified and directed by Engineer-in-Charge.
S & F in repair for CP towel racks with lower hanger complete all as specified and directed by Engineer-in-Charge.
S & F for Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed by Engineer-in-Charge.
S&F for 15 mm bore Twin one angle valve/ bib tap cast copper alloy chromium plated, fancy type, screwed down high pressure, screwed both ends for iron pipe or for union complete all as specified and directed by Engineer-in-Charge.
S&F for Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge.
S&F for PVC connections 60cm long superior quality with PTMT nut on both side complete all as specified and directed by Engineer-in-Charge.
S&F for 32 mm dia Waste coupling of PTMT (half or full threaded) .(Minimum weight 32mm?45gms)complete all as specified and directed by Engineer-in-Charge.
S&F for 32 mm dia Waste coupling of PTMT (half or full threaded) suitable for urinal . (Minimum weight 32mm?45gms)complete all as specified and directed by Engineer-in-Charge.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S&F CP jet for EWC along with pvc connection complete all as specified and directed by Engineer-in-Charge.
S&F for Toilet paper holder,stainless steel, fixed with and including chromium plated brass screws and and wooden/plastic cleats on walls, complete all as specified and directed by Engineer-in-Charge.
S&F for health faucet (ABS body) mils steel chromium plated suitable for 15mm dia pipe with 1.25 mtr along flexible tube and ABS wall hook incl making connection and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F for liquid soap container of PTMT fixed with and incl CP brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
S&F Steelness steel Soap dish approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F for Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified and directed by Engineer-in-Charge.
S&F Tublar towel rail 20 mm dia, D type, 60cm long between flanges of brass chromium plated fixed with and incl chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 20mm dia Nipple suitable for HDPE water tank.(Minimum weight 20mm 45gms ) complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm dia Unions. brass to connect iron to polyethylene and fixed complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel pegset of six suitable size of length etc complete all as specified and directed by Engineer-in-Charge.
S&F for 32/40 mm dia PVC waste pipe for WHB/sink, complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed by Engineer-in-Charge.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
All as per item No 85 above but laid in trench or in floor complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed by Engineer-in-Charge. .
S&F for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 100 mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
All as per item No 91 above but laid in trench or in floor complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in ground floors and paving n. exc 15 cm thickness below or above gound level , concrete debris and rubbish to a distance n exc 100m complete all as specified and directed by Engineer-in-Charge.
M & L for machine pressed chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone agg. ) as in plinth protection / path/ any paved area complete all as specified and directed by Engineer-in-Charge.
M&L for Surface excavation n.exc 30 cm deep and and avg 15 cm deep and getting out soft and loose soil complete all as specified and directed by Engineer-in-Charge.
M & L broken bricks hard core of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed by Engineer-in-Charge.
M&L for 60 mm thick machine cut precast concrete inter locking paver block except tile ,(M-35) grade any clours complete all as specified and directed by Engineer-in-Charge.
M&L for 80 mm thick machine pressed and machine cut precast concrete inter locking paver block glossy finish with grey cement and pigment ,(M-40) grade (confirming to IS 15658-2006) any clours complete all as specified and directed by Engineer-in-Charge.
M&L for 80 mm thick machine cut precast concrete inter locking paver block except tile ,(M-40) grade any clours complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as specified and directed by Engineer-in-Charge.
M&L for in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance exc 1.5 KM but not exceeding 5 KM and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed by Engineer-in-Charge.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators as per specified SSR and complete all as specified and directed by Engineer-in-Charge. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls..
All as per item No 110 above but 5 Amp socket outlet, independent complete all as specified and directed by Engineer-in-Charge.
All as per item No 110 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano, flush type single pole, one way, 15 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing socket outlet 3 pin , 3 pin 15 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling roses, 3 phase, PVC/Polycarbonate, isolated body complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of LED tube light along with fixture,20W complete with all accessories with twin conductor complete all as specified and directed by Engineer-in-Charge.
Supply and install in replacement SPN enclosure including plug And socket with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan sweep 300 mm in replacement made up of sturdy engineering plastic complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-Charge.
M&L for earthing with galvanised steel plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25mtr deep from ground level) surrounded from all directions with charcoal dust, salt and edge of earth plate not less than 1.5 mtr below ground level connected to galvanised iron strip 4mm dia. earth lead by means of nuts, bolts and washers incl excavation and earth work PCC chamber and RCC cover of 1:2:4 type B-1 using XPM weighing not less than 4 Kg/Sqm using 20mm graded stone aggregate for coping/under covers, 20mm size GI pipe light grade for watering funnel wire mesh etc, complete all as specified and directed by Engineer-in-Charge and shown in electrical plate No-03 of SSR Part-I.
Supply & fixing in replacement of MCB SP 6 to 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge.
M& L for taking down and refixing Ceilling fan / exhaust fan of any type and rating on any surface complete all as specified and directed by Engineer-in-Charge.
M/S Yamin
M/S Rohit Enterprises
R. S. Associates
Maninder Singh Lohia
SAGAR ENTERPRISES
36SHRI RADHEY ASSOCIATES
VED PRAKASH ARORA
Singh Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .