Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3.7 Cr
EMD Value
₹2.0 L
Closing Date
20 Nov 2026, 3:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Officer
Arulmigu Kulasekara Perumal tirukovil,kallidaikuruchi,Ambasamudram taluk,tirunelveli dt
Repair and restoration works of the Arulmigu Kulasekara Perumal tirukovil,kallidaikuruchi,Ambasamudram taluk,tirunelveli dt
2026_HRCE_712301_1
4/2026
Open Tender
Civil Works - Others
Item Rate
650 days
Repair and restoration works/Kallidaikuruchi
Please refer tender Documents
7 documents required · 7 mandatory
₹0
₹2.0 L
22 Oct 2026
22 Oct 2026
20 Nov 2026
22 Oct 2026
20 Nov 2026
22 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling the existing laid weathering course Lime concrete including clearing away from the site etc complete | 110 | cum | - | - |
| 2 | Dismantling the existing Brick work in Lime Mortar including clearing away from the site etc complete. | 140 | cum | - | - |
| 3Labour charges for removing the Existing cutstone flooring including numbering , wire charges , tools and plants, scaffolding for working in heights etc complete. | |||||
| 3.01 | a) For Chitranvanam, Padma Jagati, Kandam, Uthira vari, Kabothagam, Viyalam, Ull Vari, Pavukkal, Flooring, Nilaikal etc complete. | 1,441 | sqm | - | - |
| 3.02 | b) For Thani Thun , Uthiram & Bothiyal etc complete. | 20 | cum | - | - |
| 3.03 | a) For Flooring | 244 | sqm | - | - |
| 4 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except to rock requiring blasting but including shoring strutting and bailing out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick well consolidated and depositing the surplus earth within the compound with an initial lead of 10 metres and lift of 2 metres in places as shown by the departmental officers and clearing levelling the site etc complete complying with standard specification. | 734 | cum | - | - |
| 5 | Cement concrete 1:5:10 (one cement five sand and Ten aggregate) using 40mm gauge hard granite broken stone jelly for foundation including cost and conveyance of all materials labour for mixing, laying, compacting, curing, dewatering, side shuttering, wherever necessary including curing etc.,complete complying with standard specification. | 71 | cum | - | - |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
For Raft slab & Plinth Beam | 976 | sqm | - | - |
| 7 | Providing and laying in position, Standarzised Concrete Mix M-20 Grade in accordance with IS:456-2000,using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimumcement content of 325 kg/mᶾ and maximum water cement ratio of 0.55, including admixture (plasticiser /super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete,improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mmmachine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jellyand with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricatingcharges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing,curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary withoutclaiming extra, etc., complete complying with standard specification and as directed by the departmentalofficers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). For Upto Basement | 280 | cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
tenderconditionsa.pdf
Tender Documents • 0.72 MB
BOQ_855666.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .