Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.3 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 1 | Accepted-AOC Being the lowest bidder. | |
| 2 | 2₹6.5 L+₹1.2 L (22.0%)Rejected-AOC 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | 2 | Rejected-AOC Being other than the lowest bidder. | |
| 3 | 3₹7.7 L+₹2.3 L (43.9%)Rejected-AOC 687 ARYA NAGAR POWAYAN ROAD SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | 3 | Rejected-AOC Being other than the lowest bidder. |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
10 Mar 2022, 6:00 pmClosed
CWE Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO. CWE BLY / GE(E) / 119 OF 2021-2022 REPAIR TO REFRIGERATOR, WINDOWS/SPLIT TYPE AC, WATER COOLER, DESERT COOLER, VOLTAGE STABLIZER AND DEEP FREEZER AT MIL STN SHAHJAHANPUR UNDER GE (EAST) BAREILLY
2022_MES_507583_1
8200/B/711/E8
Open Tender
Civil Works
Item Rate
180 days
Shahjahanpur
Class E Category b(i) For Unenlisted Contractor - Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value of work, Annual turnover, working capital , etc as mentioned in NIT.
6 documents required · 6 mandatory
₹500
Yes
GE(E) Bareilly
₹20,000
Yes
28 Mar 2022
12 Feb 2022
17 Mar 2022
12 Feb 2022
10 Mar 2022
26 Feb 2022
Amount
S&F in replacement taking out the old unserviceable sealed compressor unit from existing Split/window type AC 1.5 ton capacity of any make by cutting and replacing the same with new sealed unit from authorised OEM workshop/manufacturer and reconnecting the replaced sealed compressor unit to its original position of air conditioner by brazing incl flushing out complete refrigerator system by applying CTC/nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity after complete equating and cleaning the system reinstalling the air conditioner at site and testing on false load to its satisfactor performance complete all as specified and directed.
All as per item No 1 here-in-before but for capacity of air condition (2.00 ton) complete all as specified and directed.
M&L for Flushing the complete refrigeration system and repairing of leakage pipe lines by brazing and charging the unit by compressor oil and refrigerant Gas-134 to its full capacity after evacuating and cleaning the complete system and installing, commissioning and testing for its smooth functioning for 72 hours on full load complete all as specified and directed.
S&F in repairs for over load protector suitable for AC protector complete all as specified and directed.
S&F in repairs for condensor unit copper type suitable for split/window AC 1.5 ton capacity complete all as specified and directed.
S&F in repairs relay suitable for 1.5 Ton (window/Split type) air conditioner complete all as specified and directed.
S&F in repairs thermostat switch for AC complete all as specified and directed.
S&F in repairs switch controlling knobs along with complete control panel for any make and any size of AC complete all as specified and directed.
S&F in repairs running capacitor of required 36/45 MFD complete all as specified and directed.
S&F in repairs starting capacitor of required 120 MFD complete all as specified and directed.
M&L for repairing of voltage stablizer of any make and size of 4 KVA to 5 KVA by repairing/replacement of electric circuit and rewinding including insulating materials complete all as specified and directed.
S&F in repairs of PCB sutable size for window / split AC complete all as specified and directed by Engr In Charge.
Taking of old unserviceable/sealed compressor unit from existing refrigerator of 310/300 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed.
All as per item No 13 here-in-before but for capacity of refrigerator 280 ltrs complete all as specified and directed.
All as per item No 13 here-in-before but for capacity of refrigerator 165/175 ltrs complete all as specified and directed.
M&L for Flushing out complete refrigeration system by nitrozen/CTC gas after deleting leakage and repairing tube/lines by brazing and charging the unit with compressor oil and refrigerant Gas-134 to its full capacity of refrigerator 300 lts capacity of any make including commissioning and testing for its smooth functioning complete all as specified and directed.
S&F rubber gasket of refrigerator door of any size and any make complete all as specified and directed.
Supply and replacement of thermostat switch of suitable size for any make and size of refrigerator complete all as specified and directed.
S&F in repairs for runnig capacitor of suitable size of refrigerator of any make and size complete all as specified and directed.
S&F in repairs for starting capacitor 40 MFD capacity complete all as specified and directed.
S&F in repairs for relay assembly suitable for refrigerator starting capacitor 40 MFD capacity complete all as specified and directed.
S&F in repair for over load protector suitable for refrigerator protector complete all as specified and directed.
Supply and replacement of freezer door of any make 310/300/286 ltrs size of refrigerators complete all as specified and directed.
All as per item No 23 here-in-before but size of refrigerator 165/175 ltrs complete all as specified and directed.
Repair to body of refrigerator of any size/capacity by welding of MS Sheet not less than 1.6 mm thich to match existing after receiving old rusted/unserviceable portion replacement of old nut bolt washers and hinges of top cover incl painting to complete body of refrigerator with two coat of synthetic enameled paint after preparation of surface and removing dentscomplete all as specified and directed.
Taking of old unserviceable/sealed compressor unit from existing deepfreezer of 300/310 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing incl flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance incl painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed.
Taking out the broken legs from the base of refrigerator supplying and fixing new legs set of 4 to put the refrigerator of any capacity/make in to vertical position complete all as specified and directed.
S&F in repairs for condensor unit suitable for deep freezer of existing size any capacity complete all as specified and directed.
M&L for repairing of voltage stablizer of any make and size of 2 KVA to 3 KVA by repairing/replacement of electric circuit and rewinding including insulating materials complete all as specified and directed.
Taking out the old unserviceble sealed compressor from existing water cooler of any capacity of any make 120/60 and 150 ltrs storage capacity by cutting, replacing the same with new compressor from nanufacturer and re-connecting the replaced sealed comressor, unit to its original position of water cooler by brazing incl flushing out complete refrigeration system by applying/using CTC Nitrogen gas, charging the refrigeration system with and incl compressor oil and refrigerant R-134 gas to its full capacity after complete evacuating and cleaning the system reinstalling the water cooler at site and testing on full for its satisfactorily performance complete all as specified and directed.
All as per item No 30 here-in-before but for capacity of water cooler 40/60 ltrs complete all as specified and directed.
M&L for Flushing out complete refrigeration system by CTC and repairing the leaking pipe/joints by refrigeration brazing and charging the unit with compressor oil and refrigerant gas after evacuating and flushing to its full capacity of any size and make of water cooler complete all as specified and directed.
S&F in repairs for condensor unit suitable for water cooler any capacity complete all as specified and directed.
S&F in repairs for running capacitor of suitable size of water cooler of any make and size complete all as specified and directed.
S&F in repairs for starting capacitor 80/100/120 mfd capacity complete all as specified and directed.
S&F in repairs for relay assembly 412Y/312Y complete all as specified and directed
S&F in repairs for over load protector suitable for water cooler protector complete all as specified and directed.
S&F in repairs for thermostat for water cooler complete all as specified and directed.
S&F in repairs rubber bedding gasket for any make and size of water cooler tank cover upto 25mm bore complete all as specified and directed.
M&L for repair to body of water cooler of any size/capacity by welding of MS sheet not less than 1.6mm thick to match existing agter receiving old rusted/unserviceable portion, replacement of old nut bolt washers and hinges of top cover including painting to complete body of W/C with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed.
S & F Concussive pushbutton taps for water cooler of cast copper alloy 15mm, screwed for iron pipe and fixed complete all as specified and directed.
S&F in Replacement of PVC copper cable 2.5 sqmm multistrand three core complete all as specified and directed.
M&L for repairing of voltage stabilizer of any make and size of 0.5 KVA to 1 KVA by repairing/replacement of electric circuit and re-winding including insulating materials complete all as specified and directed.
Supply and Fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Material and labour for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as an earth continuity conductor complete all as specified.
Material and labour for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as an earth continuity conductor complete all as specified.
M&L for complete overhauling of desert cooler of any size and make including replacement of perished wiring oiling and greasing the blower motor exhaust fan and water lifting/tullu pump including replacement of plastic unserviceable spares susch as ben, water distributor and PVC pipe including replacement of wood pads, preventing leakage if any by welding, painting of water tank with rubber seal of any approved make and testing the same for its smooth functioning complete all as specified and directed.
M&L for Desert cooler fan/ exhaust fans any type 230 V, AC sup, Single phase dismantling the cooler fan/ exhaust fans and taking out complete burnt winding from cooler fan motor and rewinding the same with super enameled copper winding wire of existing gauge and size incl throughly cleaning all the components of cooler fan, oiling and greasing painting with one coat of synthetic enamel paint after scrubbing and preparing the old painted surfaces & testing etc complete all as specified and directed.
M&L for two coats of painting for desert cooler cover a coat of red oxide primer including preparation of old surfaces on complete body of desert cooler of existing colour after removing dents and preparing surface complete all as specified and directed.
S&F in replacement of water lifting/tullu pump submersible type complete all as specified and directed.
S&F in replacement of wood wool for desert cooler of any size complete all as specified and directed.
Supply and fixing capacitor Dry type 4 MFD 230 volts for Exhaust/cooler fan of any type complete all as specified and directed.
Supply and Fixing of fan blade for Desert cooler of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for AC of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for water cooler of any type and any size complete all as specified and directed.
Supply and Fixing of fan blade for deep freezer of any type and any size complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 34,173.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S CHAUHAN ELECTRIC WORKS
M/S MANSI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .