Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹71.7 LAccepted-AOC | L 1 | Accepted-AOC Lowest One work order issued on 02.05.2025 | |
| 2 | L 2₹72.4 L+₹73,454.19 (1.02%)Rejected-AOC | L 2 | Rejected-AOC Second Lowest Unsuccessful Tenderer EMD amount to be refund | |
| 3 | L 3₹75.4 L+₹3.7 L (5.18%)Rejected-AOC | L 3 | Rejected-AOC Third Lowest Unsuccessful Tenderer EMD amount to be refund | |
| 4 | L 4₹79.4 L+₹7.7 L (10.8%)Rejected-AOC 6 8 GURULINGAPURAM SATTUR TOWN AND TALUK 626203 | VIRUDHUNAGAR | TAMIL NADU | 626203 | L 4 | Rejected-AOC Fourth Lowest Unsuccessful Tenderer EMD amount to be refund | |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹93.5 L
EMD Value
₹56,800
Closing Date
26 Feb 2025, 6:00 pmClosed
Superintending Engineer South Circle TNPHC Ltd
Tamil Nadu Police Housing Corporation Limited South Circle No 1 Inspector Quarters TSP VI Battalion Campus New Natham Road Madurai 625014
Providing Special repair works for 1 No. of INS, 4 Nos. of SI and 54 Nos. of PC/HC quarters at AR Campus RAMANATHAPURAM in Ramanathapuram District under Priority and Monsoon Related works for the year 2023-2024
2025_TNPHC_526505_1
SE/SC No.36/2024-2025-3
Open Tender
Civil Works
Lump-sum
183 days
RAMANATHAPUARM ARCAMPUS IN RAMANATHAPURAM DISTRICT
Refer Tender Documents
7 documents required · 7 mandatory
₹0
₹56,800
9 May 2025
20 Feb 2025
28 Feb 2025
20 Feb 2025
26 Feb 2025
20 Feb 2025
Amount
DI0027) Dismantling the damaged Pressed tiles laid over cement mortar and Weathering Course lime concrete without affecting the adjacent structures
FL0047) Finishing top of roof with one course of hydraulic pressed tiles of approved superior quality of size 23cmx23cmx20mm thick with water proofing compound
FL0025) Weathering Course with concrete broken brick jelly 20mm gauge
DI0041.a) Dismantling the existing damaged RCC by manual / by using deploying machineries
FW0004) Providing Form work and centering for reinforced cement concrete works c) For Square and rectangular columns and small quantities such as sunshade, parapet cum drops window boxiing, fin projection and other similar works.
C0042) Providing and laying in position, Standardised Concrete Mix M-30 Grade b) In Ground Floor
c) In First Floor
d) In Second Floor
e) In Third Floor
RE0005) Supplying, fabricating and placing in position of Mild steel Grills / Ribbed Tor Steels (without cement slurry) (Binding wire insulated with PVC)
RE0009.a) Applying one coat of anticorrosive treatment on steel reinforcement rods
DI0012) Clean Removal of Cement plaster from walls without affecting the adjacent structures
B0041) B.W in CM 1:4 using kiln burnt country bricks 8¾”x4¼”x2¾” (22x11x7cm) with Admixture for stair case steps including proper setting, scaffolding, curing etc.,
B0053) Brick Partition wall in Cement Mortor 1:4, 110mm thick using kiln burnt country bricks of size 8¾”x4¼”x2¾” (22x11x7cm) with admixture a) In Foundation and Basement
d) In Third Floor
B0012) Brick Work in Cement mortar 1:5 using kiln burnt country bricks of size 8¾”x4¼"x2¾” (22x11x7 cm) with admixture in foundation and basement
PL0003) Plastering with Cement mortar 1:5, 12mm tk with admixture
PL0006) Plastering with Cement mortar 1:4, 12mm thick with Admixture
PL0013) Special ceiling plastering in Cement Mortar 1:3, 10mm thick with admixture
C0068) Chipping of concrete and roughening the surface without affecting the adjacent structures
FL0109) Plastering the top of flooring in Cement mortar 1:4, 20mm thick with admixture
GR0001) Supplying and fixing Mild Steel grills as per the design approved
RE0009) Applying one coat of Anticorrosive treatment for steel window/ M.S. Grills
PA0026) Painting the new Iron work and other similar works such as PVC /ASTM Pipes, Kerb Stone and grills with two coats
PA0042) Painting the old iron work with two coats of approved first class synthetic enamel ready mixed paint including scrapping and removing old paint from structural steel by manual labour
PA0043) Painting the old wood work with two coats of approved first class synthetic enamel ready mixed paint removing old paint from doors windows and works by manual labour
JD0073) Providing and fixing factory made unplasticized polyvinyl chloride (UPVC) Door Frame with shutter
DI0071) Thorough scrapping the old plastered surface with soap, soda and water etc.,
PA0018) Painting primer coat using approved quality of white cement over the cement plastered / concrete wall surfaces,ceiling or other similar works
PA0004) White washing two coats using clean shell lime slaked including cost of lime, gum, blue, brushes, including scaffolding and scrapping the surface etc.,
PA0037) Painting the New walls with two coats of approved best ready mixed plastic emulsion paint for inner walls
PA0044) Painting the old walls with two coats of approved best ready mixed Plastic Emulsion paint excluding primer and including thorough scrapping
EL0004) Wiring with 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable with surface run by means of 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable (open wiring) a. Light point with ceiling rose
b. Light point without ceiling rose
EL0028) Wiring with 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable for 5 amps 5 pin plug socket point at Switch Board Itself (Open wiring)
EL0036) Wiring with 1.5 sqmm copper PVC insulated unsheathed single core 1.1 KV grade cable for 5 amps 5 pin plug socket point at convenient places (Open wiring)
LPS0005) Earthing as per the ISI specification with an earth electrode of 2.1mt class `B` G.I pipe dia not less than 40mm, with copper earth plate of size 125mmx50mmx6mm, with necessary funneling arrangements with necessary masonary work and with 38mm RCC cover slab for the birick masonry.
EL0201) Run off 4 wires of 4 Sq mm. PVC insulated single core multi strand fire retard flexible copper cable (for EB service connection).
EL0221) Supplying and fixing 1 No. of 32 amps 500 volts grade porcelain Fuse unit
EL0187) Run of main with 2 wires of 1.5 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable (Open wiring)
EL0189) Run of main with 2 wires of 2.5 Sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable [Open wiring]
EL0070) Supplying and fixing of 9 watts LED bulb
EL0072) Supplying and fixing of 12 Watts LED Bulb for Bulk head fittings
EL0047) Supplying and fixing of 4'18 watts crystal LED tube light and fixing the tube light fittings
EL0078) Supply and delivery of following Electric Ceiling fan with ISI mark a) 48" Electric fan 1200mm sweep
EL0075) Charges for assembling and fixing of ceiling fan of different sweep with necessary connections and fixing of fan regulator
WS0003) Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark conforming to IS 13952:1992- type `A` for Rain water down fall pipe (UPVC Special Clamp)
WS0006) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 of wall thickness a) 32mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI/GM specials
b) 25mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI/GM specials
WS0033) Supplying and fixing of half turn C.P Long body Tap of 15mm dia
WS0036) Supplying and fixing of half turn C.P short body Tap of 15mm dia
SA0019) Supplying and fixing of Indian Water Closet white glazed (oriya type) of size 580 mm X 440 mm In Ground floor.
SA0020) Supplying and fixing of Indian Water Closet white glazed (oriya type) of size 580mmx440mm (Other than ground floor)
SA0033) Supplying and fixing of PVC SWR pipe (Soil line) with ISI mark - type 'B'. a) 110mm dia PVC SWR pipe including all required PVC specials etc., all complete.,
b) 75mm dia PVC SWR pipe including all required PVC specials etc., all complete.,
CS0039) Supplying and Fixing of fibre mixed precast slab of 50mm thick of all required shapes made in C.C 1:3:6
EL0100) Supplying and fixing of 25 watts LED bulb with Street light fittings arrangements
EL0045) Supplying and fixing of water tight Bulk head fitting suitable for 12w LED bulb with guard
JD0001) Supplying and fixing of Teak wood Panelled Single leaf door shutter with Aluminium fittings Suitable for Door of sizes a) 900 x 2100 mm
C0057) Supplying and fixing Monolithic RCC door frames using standardised Concrete mix M30 Suitable Door of Sizes a) 900 x 2100 mm
J0017) Supplying and fixing of 4mm thick pin headed Glass panels
WS0004) Supply and errection of Rotational Moulded Polyethylene water storage tanks (HDPE Cylinderical vertical type) for outdoor use having capacity of 700 litres
B0025) Brick Work in Cement Mortor 1:6 using kiln burnt country bricks of size 8¾”x4¼”x2¾” (22x11x7cm) with admixture c) In Second Floor
E0001) Earth work excavation for foundation in all soils (including refilling) a) 0 to 2 mt.
SA0048) Supplying, laying and jointing the following dia UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm dia UPVC Non Pressure pipe
KARTHIGAISAMY (BID ID -1257669)
A VELANI (BID ID -1257107)
MANOKARAN (BID ID -1257585)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_626960.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .