Garrison Engineer
Garrison Engineer C/O 56 APO
REPAIR/MAINT OF FCUS ACS SUMMER AND HEATING APPLIANCES AND CONNECTED WORKS AT AF STN LEH
2021_MES_432451_1
GEAF-51/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF LEH
As Per Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) LEH
₹30,000
Yes
27 May 2021
24 Mar 2021
3 May 2021
24 Mar 2021
1 May 2021
7 Apr 2021
60 days
Amount
Disconnecting, servicing and cleaning electrically operated FCUs of capacity 3000/ 4500 /6000 Kcal/hr from thermic fluid line complete and keeping aside for de-scaling/decarbonising , cleaning in all respect with suitable solution / solvent , checking all pipes leakage (inlet and outlet of FCUs) and brazing the punchered pipe where required, replacement of gate valve whereever required, cleaning of Y-strainer , including replacement of wiring of FCUs and reassembling and testing of the same complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of Fan coil unit of cap 6000 KCal/Hr, PCB controlled with 3 Rows Deep copper coil in 3/8" construction including 12 mm thick pre - filter, DIDW Centrifugal blower with single phase direct driven motor including taking down old userviceable Fan coil unit complete all as specified and directed by Engineer-in-charge.
S&F in repairs of Fan coil unit of cap 4500 KCal/Hr, PCB controlled with 3 Rows Deep copper coil in 3/8" construction including 12 mm thick pre - filter, DIDW Centrifugal blower with single phase direct driven motor including taking down old userviceable Fan coil unit complete all as specified and directed by engineer-in-charge.
Taking out air space heater of capacity 60000 K Cal/Hr, disconnecting electrically, repair of air space heater by replacement of under mentioned spare parts and cleaning of burner chamber from inside, including servicing of burners of any make painting out side body with two coats of synthetic enemelled paint and writing of MES No complete all as specified and directed by Engr in charge. Note :i) Spares parts will be measured and paid under Sch Item No. 4.01 to 4.06 ii) Rate for labour and T&P required for supply only items are deemed to be included in above quoted rate.
Supply only Solenoid valve of suitable size, 220 V AC
Supply only nozzle
Supply only fuel pump
Supply only fuel filter element
Supply only photo cell
Supply only sequence controller
S & F in replacement for compressor of 320 / 400 ltr Deep freezer including necessary brazing work as required including re assembling and testing complete all specified and as directed by Engr- in-Charge
S & F in replacement for thermal over load relay of 320 / 400 ltr deep freezer all specified and as directed by Engr- in-Charge
S & F in replacement for Thermostate switch of 320 / 400 ltr deep freezer all specified and as directed by Engr- in-Charge
M & L for refilling of R-134a gas of 320 / 400 ltr deep freezer including necessary arrangement for gas filling.
S & F in replacement of compressor for refrigerator of capacity 280/310 Ltrs including necessary brazing work as required including re assembling and all specified and as directed by Engr- in-Charge
S & F in replacement of Thermostate switch for refrigerator of capacity 280/310 Ltrs all specified and as directed by Engr- in-Charge
S & F in replacement of thermal overload relay for refrigerator of capacity 280/310 Ltrs all specified and as directed by Engr- in-Charge
M & L for refilling of R-134a gas for refrigerator of capacity 280/310 Ltrs including necessary arrangement for gas filling all specified and as directed by Engr- in-Charge.
S & F in replacement of compressor sealed unit for refrigerator of capacity 165ltr/210ltr including re assembling and testing compete for the all specified and as directed by Engr- in-Charge.
S & F in replacement of Thermostate switch for refrigerator of capacity 165ltr/210ltr including re assembling and testing compete for the all specified and as directed by Engr- in-Charge.
S & F in replacement of Capilary tube for refrigerator of capacity 165 / 210ltr including re assembling and testing compete for the all specified and as directed by Engr- in-Charge.
S & F in replacement of thermal over load relay for refrigerator of capacity 165 / 210 ltr including re assembling and testing compete for the all specified and as directed by Engr- in-Charge.
Disconnecting electrical heat pillar of capacity 2KW/3KW and replacement of unserviceable spare parts and unserviceable burnt connection wires to make it fully serviceable and reassembling the same after repair and testing complete all specified and as directed by Engr- in-Charge. Note: Spare parts shall be measured for and paid separately under relevant items as in below, Cost of internal wiring shall be deemed to be included in quoted rates
Supply only heating rod of capacity 1KW / 1.5 KW
Supply only rotating fan with motor of suitable size
Supply only 2.5 Sqmm 2 core PVC cable copper conductor
Supply only Plug Top 15 A, 230V, AC
Taking down carefully Hot water dispensor of capacity 20 ltr of any make for carry out the repairs of unserviceable parts i.e bushes bearing, heating coil of capacity 1KW unserviceable burnt cable and other parts to make it fully serviceable and reassembling the same after repair and testing complete all as specified and directed by Engineer-in-Charge.
Rewinding of voltage stablizer of capacity 3 to 5 KVA single phase with standard copper enamel wire and making connections (internal) including replacement of control card of voltage stabilizer PCB sensor, ICs and relays etc and testing the stablizer complete all as specified and directed by Engineer-in-Charge.
Servicing and repair of Heating Pads convection type of cap 1500x2/ 2000x2 watts at different locations as specified and directed including replacement of spare parts. Note : i) Spares parts will be measured and paid under respective items. ii) Rate for labour and T&P required for supply only items are deemed to be included in above quoted rate.
Supply only Thermostatically controlled switch
Supply only heating element of cap 1500/2000W
Supply only Digital LED Display
Servicing of split type ACs of cap 1.5 / 2 Ton with air blower by taking down from the site and washing the filters, cooling coil and condensing coil with detergent and open the fins with acid and refixing the same at same location including testing complete all specified and as directed by Engr- in-Charge.
Taking down carefully split type Air conditioners of capacity 1.5 / 2 Ton of any make for carry out the repairs and reassembling the same after the repairs, installation and testing. Note : i) Spares parts will be measured and paid under respective items. ii) Rate for labour and T&P required for supply only items are deemed to be included in above quoted rate.
Supply only compressor rotary type for 1.5 ton capacity AC unit.
Supply only compressor rotary type for 2 ton capacity AC unit.
Supply only PCB of inner unit of 1.5 / 2 Ton AC.
Supply only condensing coil complete for 1.5 / 2 Ton AC.
Supply only cooling coil complete for 1.5 / 2 Ton AC.
Supply only filter flap for indoor unit complete set.
Supply only reverse cycle type valve for Hot & Cold mode for 1.5 / 2 Ton capacity AC
Supply only indoor unit blower with fan and bushes for 1.5 / 2Ton capacity AC.
Supply only starting capacitor 250 mfd + 10 mfd (combined unit).
Supply only refilling gas ( R-22 / R410) in 1.5 / 2 Ton AC.
Supply only running capacitor 50 ± 6 mfd
Supply and fixing route pipe (copper tube) of size 3/8" or 5/8" dia complete with insulation.
Supply and fixing Heating element of capacity 4.0 KW (12") BSP flange 1.25" Hex Head 230 V 50 Hz AC suitable for Solar Water Heater of any Cap.
Supply and fixing Heating element of capacity 1.5 / 2.0 KW for storage type geyser
Supply and fixing Thermostat suitable for heating element of capacity 1.5 / 2.0 KW
Note : Schedule of credit for Rs. 16,230.00 (Rupees Sixteen Thousand Two Hundred Thirty Only) to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
Top Mind Industries Pvt Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .