Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹22.5 L+₹2.5 L (12.7%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
24 Dec 2020, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
PROVN OF TOILET BLOCK FOR COLLECTION PARTIES AT FSD POONCH PROVN OF SEPTIC TANK SOAKAGE WELL WITH ALLIED INFRA FOR INF BDE CAMP AT POONCH AND SPECIAL REPAIRS/REPLACEMENT OF BER COOLING AND HEATING APPLIANCES UNDER AOR OF STN HQ POONCH UNDER GE881 EWS
2020_MES_396739_1
GE/PNH-52/2020-21
Open Tender
Civil Works
Lump-sum
240 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹37,000
Yes
29 Dec 2020
20 Nov 2020
26 Dec 2020
20 Nov 2020
24 Dec 2020
11 Dec 2020
Amount
Schedule 'A' Part-I (Building Work) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-I (Building work) brought forward from srl page No-19.
Schedule 'A' Part-II (Internal Water Supply works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-II(Internal Water Supply works) brought forward from srl page No-20
Schedule 'A' Part-III (Plumbing works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-III(Plumbing works) brought forward from srl page No-21
Schedule 'A' Part-IV (Sec-I) (Internal Electrification works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-IV (Internal Electrification works) brought forward from srl page No-23
Schedule 'A' Part-IV (Sec-II) (Internal Electrification works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Tube light fitting with universal batten suitable for T8 LED lamps LED 20W tube Rod with end cap complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 20LED tube rod 4 feet long (Double Side Connection) fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:-REGALBATTENT8UPTO1X22WSSBSWH for fittings & CRYSTAL 1213T8DSTL20WLED865SGLASS for LED tube rod or Equivalent cat part of make as specified in Appx 'A' here in after. Note :- The LED batten and LED tube rod shall be of same make.
LED street light fittings 30W made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with hosing with all accessories pre wired with and including 40mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shap & 40x6mm siize, nut, bolts, washers and making connection with three core copper flexible cable of suitable size to light fitting fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:-ENDURAPEARLSL30WLED757SASYTOPCMP or Equivalent cat part of make:-Wipro / Crompton / Bajaj.'.
LED lamp ADORE 10 watt with holder base (B22) type & 5star rating, 1200mm lumen outputcomplete all as specified. Make of LED lamp:- Havells cat part No-LHLDEUEBML8Z010 or Equivalent cat part of make:-Wipro / Crompton / Bajaj / cropmpton
MCB single pole and neutral 6 to 32 amps 240 volts 10 KA 'C' series all as specified. Make:- Havells cat part No-DHMGCSNF006-032 or Equivalent cat part of make of make:-Legrand /Indoasian.
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or equivalent cat part of make-Legrand / INDOASIAN / L&T
Schedule 'A'Part-V(Sec-I) (Sewage Disposal Works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-V(Sec-I)(Sewage Disposal WorKs) brought forward from srl page No-25
Schedule 'A'Part-V(Sec-II) (Sewage Disposal Works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Construction of conventional type on site LLDPE septic tank for 5 users designed to carry sewage and sludge water with & including earhtwork in any type of soil and mass concrete in PCC 1:4:8 below foundation, vent shaft, connection etc. complete all as specified.
Schedule 'A'Part-VI(External water supply Works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-VI(External water supply Works) brought forward from srl page No-26
Schedule 'A'Part-VII(External Electrification Works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-VII(External Electrification Works) brought forward from srl page No-27
Schedule 'A'Part-VIII(Area Drainage Works) JOB NO. SHQ/LBW-07/2020-21)(Toilet block at FSD Poonch)
Total amount of Sch 'A' Part-VIII(Area Drainage Works) brought forward from srl page No-28
Schedule 'A'Part-IX (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.(JOB NO. SHQ/POONCH/SR/EM/01/2020-21)(Spl rep of cooling and heating appliances at Poonch),(JOB No. SHQ/LBW-09/2020-21)(Prov of septic tank and soakage well for INF BDE Camp at Poonch)
B&R Portion:- Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc. not exceeding 10sqm on plan and not exceeding in depth and getting out in any type of soil, complete all as specified.
Description all as per srl item No 12 above but exceeding 1.5mtr and not exceeding 3mtr depth, complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed
Concrete bed to drain pipes including packing under and haunching against the sides of pipes for 150mm SGSW pipe after they are laid in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) & tested, complete all as specified and directed.
RCC pipes class NP2 of 150mm dia laid in trenches and jointed with one collar per length of pipe, laid in trenches or in floor complete all as specified and directed
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:4), all as specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified.
15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces with mixing of liquid water proofing admixure as per manufacturer's instruction & finishing the surface even and smooth without using extra cement, complete all as specified. Note:-Liquid water proofing admixture shall be measured & paid seperately.
Supply only Liquid water proofing admixture.
Cement concrete (1:2:4) using 20mm graded stone aggregate as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified
Precast cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:6) including necessary form work complete all as specified and directed by Engineer-in-Charge.
Cutting of road, path, drain, paved area, steps etc of any description upto 1.5 mtr length of required width & depth as per site for laying of NP-02 pipe for the dismantelled / demolished portion & making good the same by matching the existing surface with PCC 1:3:6 type C-1 (using 20mm crushed stone aggregate), complete all as specified.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified.
Cutting /Trimming/ Chopping of tree roots below ground level for laying of NP-02 pipe for a width of 45 cm & providing acid on cut portion of roots (to stopped the growth of roots) along with making good the exising surface complete all as specified & directed.
E&M Portion:- Supply, installation commissioning and testing of all weather cooling and heating type Split unit air conditioner electric driven, single phase of capacity 1.5 TR, BEE five star rated all as specified and directed. Make:- Voltas Model AC18HSZS or equivalent in Hitachi/ Carrier/ LG/ Godrej
Supply, installation, commissioning and testing refrigerator, electric dirven, single phase, 230 V, 50 Hz of capacity 235 Ltr , five star rating, all as specified and directed. Make: LG / Voltas/Samsung/ Whirlpool
Supply, fixing, commissioning & testing geyser of cap 25 ltrs five star rated ISI marked storage type with suitable fixing accessories & making good and matching existing surface and finish all as specified & directed. Make: Havells (Monza DX) or equivalent cat part of make CG/Bajaj.
Supply, fixing, commissioning & testing geyser of cap 50 ltrs five star rated ISI marked storage type with suitable fixing accessories & making good and matching existing surface and finish all as specified & directed. Make: Havells (Monza DX) or equivalent cat part of make CG/Bajaj.
Supply and fixing of ceiling fan 1200mm sweep, 230V, 50Hz with all accessories all as specified and as directed. Make: Havells/ Khaintan/Usha
Supply and fixing of exhaust fan 450mm sweep, 230V, 50Hz with all accessories all as specified and as directed. Make: Havells/ Khaintan/Usha
M/S RAJ ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .