Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹88.5 L+₹4.0 L (4.70%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹92.4 L+₹7.8 L (9.28%)Admitted-Finance RZ 151 BLOCK Y NEW ROSHANPURA PAPRAWAT ROAD NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAKESH DUTT SHARMA & SONS L2 | MODERN CONCEPT CONSTRUCTIONS L3 | M/s S.K.Industries L1 |
|---|---|---|---|---|---|---|
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | ||||||
| 2.00 | All kinds of soil. | 31 | cum | 570 ₹17,670 | 257 ₹7,967 | 250 ₹7,750 Lowest |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 11 | cum | 210 ₹2,310 | 227 ₹2,497 | 200 ₹2,200 Lowest |
| 4.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 21 | cum | 1,380 ₹28,980 Lowest | 2,147 ₹45,087 | 1,650 ₹34,650 |
| 5.00Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. | ||||||
| 6.00 | All kinds of soil | 1,391 | sqm | 147 ₹2,04,477 | 27 ₹37,557 | 20 ₹27,820 Lowest |
| 7.00Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. | ||||||
| 8.00 | All kinds of soil | 10 | each | 147 ₹1,470 | 77 ₹770 Lowest | 80 ₹800 |
| 9.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | ||||||
| 10.00 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 4.4 | cum | 6,600 ₹29,040 | 7,047 ₹31,006.8 | 6,500 ₹28,600 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
12 Apr 2023, 3:00 pmClosed
Executive Engineer
Office of the Executive Engineer (Civil Division-III), Room No- MZ-137, Main Building, IIT Delhi,Hauz Khas, New Delhi-110016
Renovation and Modification of Electric Vehicle Lab in CART in academic area at IIT Delhi
2023_IIT_747137_1
IITD/WORKS(SP-4184)/2023
Open Tender
Miscellaneous Works
Works
150 days
Indian Institute of Technology Delhi
As per tender documents
16 documents required · 16 mandatory
₹1,000
Registrar IIT Delhi
₹2.2 L
24 Apr 2023
28 Mar 2023
13 Apr 2023
28 Mar 2023
12 Apr 2023
28 Mar 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
All kinds of soil
Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m.
All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level :
Concrete of M10 grade with minimum cement content of 220 kg /cum
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Shelves (Cast in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
Granite stone slab of colour black, Cherry/Ruby red
Area of slab over 0.50 sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Deduct for not providing hinges in doors, windows or clerestory window shutters with :
ISI marked Stainless steel butt hinges with stainless steel screws :
For 2nd class teak wood and other class of wood shutters
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : (copper oxidized as per IS: 1378)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Exceeding 10.00 sqm and upto 16.80 sqm in the area
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm.
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:
With common burnt clay F.P.S. (non modular) brick tiles of class designation 10
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
110 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Flashings/ Aprons.( Upto 600 mm)
Gutter (600 mm over all girth)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineer- in- Charge.
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand)
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.
For door/ window/ clerestory window
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer- in-Charge.(a) Internal Work- Exposed on wall
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Of area beyond 3 sq. metres
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles above 25 mm and up to 40 mm
Demolishing mud phaska in terracing and disposal of material within 50 metres lead.
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Asbestos Cement sheet
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :
75 to 80 mm dia pipe
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. Complete all as per direction of Engineer-in-Charge.
60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall
15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
15 mm nominal bore
20 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
20 mm nominal bore, 120 mm long, weighing not less than 198 gms
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge
Powder coated minimum thickness 50 micron aluminium
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600
Upto 5 mm depth and 5 mm width
Upto 10 mm depth and 10 mm width
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make. A groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately)
Outer face: Outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, Type A, as per IS:14862:2000 (high pressure steam cured) Inner Face :- 12.5 mm thick gypsum plaster board conforming to IS 2095:2011 fixed on 8 mm thick fibre cement board confirming to IS:14862:2000 of type B (High pressure steam cured)
Providing and fixing 50mm thick sandwich roof panel (factory made) as per specification as follow. a) Outer sheet; 0.50mm (TCT) precoated galvanized trapezoidal steel sheet having minimum 30mm crest depth, polyester top coat & alkyd backer. Zinc coating shall be 120 gsm as per IS-277. Top coat polyester 15-18 microns over 5-7 micron epoxy primer. b) Insulation: High density puff insulation. c) Inner Sheet: Colour coated galvanized, slightly ribbed. Thickness 0.50mm (TCT) minimum 15-18 micron top coat polyester coating, Zinc coating 120g/sqm as per IS-277 Grade of steel : Minimum 240Mpa (both sheets). Sheet should have protective guard film of 25 micron minimum to avoid scretches during transportations and should be supplied in single length upto 12 meter or as desired by Engineer-In-Charge. The sheet shall be fixed using self drilling / self tapping screws with EPDM seal, completed upto any pitch in horizontal / vertical or curved surfaces excluding the cost purlins, rafters and trusses and including cutting to size and shape wherever required. Work to be executed as per the instructions of Engineer-In-Charge.
ELECTRICAL WORK
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for light/ power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
6 x 2.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
3 x 6 sq. mm
6 x 6 sq. mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
6 Module (200mmX75mm)
12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A, 16 kA,TPMCCB
150 A, 16 kA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
16 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (MCCB as a incomer)
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Triple pole
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (Make: Siemens/ L&T/ Schneider/ Legrand/ ABB/ C&S/ Havells)
Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. Rate to be taken
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: Havells/ Beldon/ D-Link/ Polycab)
1 run of Cable
2 run of Cable
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 95 sq. mm (45mm)
3½ X 185 sq. mm (57mm)
Supplying, Installation, Testing and Commissioning of 1200 mm sweep, 32 Watt BEE 5 star rated, ceiling fan with brush less Direct current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts; washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make : Havells/ Crompton/ USHA/ Bajaj/ Orient/ )
FIRE ALARAM SYSTEM
Supplying, installation, testing & commissioning of heat detector operating at 54C/57C with rate of rise cum fixed temperature (dual thermister) type with mounting base complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (Make: Havells/ Finolex/ Polycab)
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete wit visua indications for short circuit fault,open circuit fault,fire condition and all otherstandard facilities as per IS : 2189 with mimic diagram for all area / zone covered , complete with all connections , interconnections etc as required. (Make: System-Tek/Morley/Agni/Ravel/Safeway Security System)
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, Triple pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A, 415 V, 5 pin Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63A "C" curve, TPNMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing FR PVC DLP adaptable trunking without cover of (150 mm x 50 mm) size with provision of internal partition separation for Power & LAN on surface on existing wall etc. as required. (Make: Legrand)
Providing and Fixing following assoceries on the existing FR DLP PVC turnking (150mm x 50mm) etc. as required. (Make: Legrand)
Providig and Fixing of FR PVC trunking cover width 40 mm + full cover width 85 mm for Power + LAN component
Providing and fixing of Clip on partition - Plastic (Make: Legrand)
Providing and fixing of Seperation on partition - Plastic (Make: Legrand)
Providing and fixing of End caps for 150 mm x 50 mm trunking (Make: Legrand)
Providing and fixing of Internal angle for 150 mm x 50 mm trunking (Make: Legrand)
Providing and fixing of External angle for 150 mm x 50 mm trunking (Make: Legrand)
Supplying and Fixing DLP U-PVC turnking of 105mm x 50mm on surface etc as required.
Supplying and Fixing Full Flexible cover of width 85mm on existing DLP U-PVC turnking etc as required.
Supplying and Fixing of internal angle for 105mm x 50mm existing DLP U-PVC turnking etc as required.
Supplying and Fixing of external angle for 105mm x 50mm existing DLP U-PVC turnking etc as required.
Supplying and Fixing of End cap for 105mm x 50mm on existing DLP U-PVC turnking etc as required.
Supplying and Fixing 1 module arteor frame for 40 mm cover (Make: Legrand)
Supplying and fixing of 3 module arteor frame for 85 mm cover (Make: Legrand)
Supplying and fixing of 6 module arteor frame for 85 mm cover (Make: Legrand)
Supplying and fixing following modular switch/ socket on the existing 1/3/6 module frame / U-PVC trunking system including connections etc. as required.
Information socket - category 6-UTP - 1 module (Make: Legrand)
20 Amp switch
6 pin 20 Amp socket outlet/6 pin 6/16 A universal socket
Providing and fixing 125A,25kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders with SS Enclosure box(l & T make) suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system including drilling holes in SS enclosure box, making cable connections, etc. as required.
Providing and fixing 160A,25kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders with SS Enclosure box(l & T make) suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system including drilling holes in SS enclosure box, making cable connections, etc. as required.
Providing and fixing 250A,36kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders with SS Enclosure box(l & T make) suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system including drilling holes in SS enclosure box, making cable connections, etc. as required.
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc as required.
Upto 35 sq. mm (3.5C x 35 sq.mm)
Above 35 sq. mm and upto 95 sq. mm (3.5C x 50 sq.mm)
Above 35 sq. mm and upto 95 sq. mm (3.5C x 95 sq.mm)
Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp (3.5C x 50 Sq.mm)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp (3.5C x 95 Sq.mm)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) (3.5C x 185 Sq.mm)
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) (3.5C x 185 Sq.mm)
S/I/T/C of recess mounting LED luminaire with chain and hook (including dismantling of existing lights) equipped with CRCA powder coating housing, anti-glare polycarbonate diffuser with energy efficient electronic driver suitable for SMD LEDs with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage 36 watts, Output lumens not less than 1001m/watt; CCT not less than 5700K; DimensionLxWxH in mm (1195x295x70mm); Normal surge protection 2.5kV; power factor not less than 0.95; Minimum IP protection 20. (Make : Philips/ Wipro/ Havells) PLANO2X2PLR36WLED857S
S/I/T/C of recess mounting round/square LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage not more then 12 watts, Output lumens not less then 9001m; CCT not less then 6000K; slim profile surface mounted down light square/ round type; Normal surge protection 2.5kV; power factor not less then 0.9; Minimum IP protection 20. (Make : Philips/ Wipro/ Havells/ Panasonic/ Bajaj/ Crompton/ Osram)
Supplying, Installation, testing & commissioning of energy efficient LED compound light equipped with power coated PDC aluminum body & secondary optical lens for superior light distribution with energy efficient electronic driver with following features:- 130-300 Vac, 50Hz, wattage 120 Watts, efficiency not less then 110 Lm/W, CCT 6500K, Nominal surge protection 2.5 kV, Power factor not less then 0.9, Minimum IP protection 66 etc. in suitable size GI pipe with reducer, GI saddle, bracket for proper fixing as required. (Make: Philips/Havells/ Wipro)
S/I/T/C of high speed wall mounting fan 400 mm sweep, copper winding, capacitor start, suitable for operation on 230V, 50 Hz, AC supply with inbuilt speed regulator etc. complete with all standard accessories such as motor, blades clamp etc as required. (Make : Havells/ Crompton/ USHA/ Orient) Colour of fan shall be finallized by Engineer-in-charge)
S/I/T/C of 10"(250mm) size,copper wound, ventiling fresh air fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required Make Crompton Greaves / GE /Havells Ventil Air-DX White.
S/I/T/C of 12"(300mm) size,1400rpm,copper wound, heavy duty metalic Exhaust Fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required Make Crompton Greaves / GE /Havells Turbo Force SP
S/I/T/C of 15"(380mm) size,1400rpm,copper wound, heavy duty metalic Exhaust Fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required Make Crompton Greaves / GE /Havells Turbo Force SP
S/I/T/C of 18"(450mm) size,1400rpm,copper wound, heavy duty metalic Exhaust Fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required Make Crompton Greaves / GE /Havells Turbo Force SP
Supplying, Installation, Testing & Commissioning i/c making solid foundation of brick,cement concrete (0.50Mtr above the ground level) of cubical type Feeder Pillar Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 500 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.
INCOMER
1 Nos. 400 Amps. FP MCCB of 36 KA with inbuilt protection.
MAIN BUS BARS
TPN aluminium bus bars of minimum of 500 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
METERING
3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS
1 Nos. 250 Amps. FP MCCB of 36 KA with inbuilt protection.
2 Nos. 200 Amps. FP MCCB of 36 KA with inbuilt protection.
6 Nos. 160 Amps. FP MCCB of 36 KA with inbuilt protection.
Total Panel Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
Air Conditioning
Supplying, Installation, Testing and Commissioning of Split Inverter type Air Conditioner unit for cooling comprising factory built evaporator and condenser unit with other kits (remote controller with battery, suction & discharge copper pipe of length not less than 3 m each, copper cable for power connection, etc.) for installation as per following specification: Rated cooling capacity: 1.5 TR (not less than 5250 watts); Star Rating 5 star; Compressor: Rotary type inverter inbuilt for variable speed operation; Refrigerant: Ecofriendly; Material of evaporator & Condenser refrigerant pipe : Copper; Suitable for operation on 230 volt, 50 Hz, AC supply Make ( Hitachi / Blue Star/ LG/ Voltas/ Haier/ Daikin/ Mitsubishi/ O General)
Supply, Installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft drawn copper refrigerant piping for split AC unit, complete with fittings, with suitable adjustable ring type hanger supports (wherever required), jointing / brazing including accessories, insulated with nitrile rubber tube sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required : [Acceptable make of copper pipes : Uniflow / Manibhadra / Ganpati / Mexflow / Mandev / Indigo / Godrej / Visiaro]; [Acceptable make of tubular insulation: Visiaro / Marshland / Avi Global / Armaflex / Aajjo / Dynamic / Uttam]
NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The thickness of fittings used shall be same as that of the pipe
Supplying and laying ISI marked 25 mm dia pvc pipe (flexible & braided type) for drain line, including providing insulation wherever necessary, proper saddling, etc. complete as required. (Acceptable make: Astral / Supreme / Finolex / Prince / Savera / Ashirvad / Apollo)
Supplying and laying of ISI marked hard CPVC pipe of 25 mm dia for draining of sweated water from AC evaporator unit including all accessories providing tee, joints, elbows, insulation wherever necessary etc. complete as required. (Acceptable make: Astral / Supreme / Finolex / Prince / Savera / Ashirvad / Apollo)
Supplying and laying of ISI marked FRLS 4 core x 2.5 sqmm PVC insulated industrial flexible copper conductor cable of 1.1 kV grade conforming to IS 694:2010 including making connections etc. as required. (Acceptable make: Havells / Finolex / Polycab / Universal)
Supplying and fixing of prototype adjustable readymade stand made of steel for resting condenser unit either on flat surface(Floor mounted) or on wall [as per site requirement - either floor mounted or wall mounted], duly prepainted with anticorrosive paint, nuts, bolts, fasteners, grouting / properly securing from accidental fall, fasteners, etc. complete as required.
CREDIT OF DISMANTLE ITEMS
Credit of dismantle of old Iron Scrap like steel windows / door frames, MS grills, MS bars, GI pipe and fittings etc.
Credit of dismantle of old Wooden Scrap like old flush doors, wooden frames, ply, board etc.
Credit of dismantle of old PVC scrap like PVC cistern, PVC tanks, PTMT fittings etc.
RAKESH DUTT SHARMA & SONS
MODERN CONCEPT CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_785561.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .