Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹34.1 L+₹1.2 L (3.60%)Rejected-Finance HOSPITAL ROAD SOLAN TEHSIL SOLAN DISTRICT SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | L2 | Rejected-Finance 2 | |
| 3 | L3₹37.0 L+₹4.0 L (12.3%)Rejected-Finance | L3 | Rejected-Finance 3 | |
| 4 | L4₹38.6 L+₹5.7 L (17.3%)Rejected-Finance | L4 | Rejected-Finance 4 | |
| 5 | L5₹47.9 L+₹15.0 L (45.4%)Rejected-Finance | L5 | Rejected-Finance 5 |
Tender Value
₹24.1 L
EMD Value
₹43,800
Closing Date
2 Aug 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
JSV Division Jubbal
Providing LWSS GWSS to various Hab in GP kathasu Mandhol Kot Kaina Sari Brall and Dhar to cover FHTC of leftout house hold under JSV Sub Division Jubbal
2021_HPIPH_50310_1
JBL-SML-09-718
Open Tender
Civil Works
Item Rate
180 days
Mandhol
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
Yes
₹43,800
Yes
11 May 2022
24 Jul 2021
2 Aug 2021
24 Jul 2021
2 Aug 2021
24 Jul 2021
120 days
Amount
Phase 1st. Chiwa. Stage 1st. Supply and errection of standby horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mathar & Platt/Jayoti/Kirloskar confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle raw water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof electric induction motor suitable for operation on the data given below. Pump Type: WKFI 40/12 Make : KSB Capacity 60 HP Discharge 18.54 Cum/Hr. Head 363.00 Mtr. Dia of R/main 150 mm. Length of R/main 1350 Rmt.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slopring motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag , under voltage release wfith initial oil filling. Note:- Star - delta - starter upto 37.5KW , ATS between 37.5KW to 50KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto data ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conformaing to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side.
Hour run meter of reputed make of digit capacity conforming to BIS-722 (latest edition)/ recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity.
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled/ BHEL/ Leader/ of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414(API 600).
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled/ BHEL/ Leader/ of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 (API 600).
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled.BHEL/ Leader of suitable size cast iron/Cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main i.e of R/Main i.e 1.50.mm for withstanding nominal seat pressure of 52Kg/cm^2. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 (API 600).
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments. OR Supply of Kirloskar/ Jyoti/ Kilburn /IVC/ Kartar/ leader / BHEL make cast iron flanged sluice valve having equal to dia of suction pipe capable of withstanding normal seat pressure of 52 kg/ cm2 conforming to BIS 780-1984 with up to date ammendments in case of positive suction.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554(Part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter(one cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles,flexible pipe, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to aproval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost .
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(Part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to (one cable for carring all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipes, solder,nuts & bolts, cable glands etc. laid in pipes or trenches under floor. The type ,size & make will be subject to approval of HPSEB athorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost .
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L suction,delivery pipe considering site requirements , NPSH reqired & available & common header having area equal to times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. Away from the outer wall of pump house as per layout drawings approved by Engineer-in Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. Ie(ii). BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Supply of antivibration pads conforming to BIS 6337-1971 or latest with up to date ammendmentsof suitable size for above machinery.
Errection of all equipments from S.No. 37 to 40, 42 & 44 i/c cost of tees, bends tapes & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Phase 1st. Chiwa. Stage 2nd. Supply and errection of standby horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mathar & Platt/Jayoti/Kirloskar confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle raw water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof electric induction motor suitable for operation on the data given below. Pump Type: WKFI 40/15 Make : KSB Capacity 60 HP Discharge 15.84 Cum/Hr. Head 455.00 Mtr. Dia of R/main 125 mm. Length of R/main 2200 Rmt.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slopring motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag , under voltage release wfith initial oil filling. Note:- Star - delta - starter upto 37.5KW , ATS between 37.5KW to 50KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto data ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conformaing to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side.
Hour run meter of reputed make of digit capacity conforming to BIS-722 (latest edition)/ recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity.
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled/ BHEL/ Leader/ of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414(API 600).
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled/ BHEL/ Leader/ of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 (API 600).
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled.BHEL/ Leader of suitable size cast iron/Cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main i.e of R/Main i.e 1.50.mm for withstanding nominal seat pressure of 52Kg/cm^2. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 (API 600).
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments. OR Supply of Kirloskar/ Jyoti/ Kilburn /IVC/ Kartar/ leader / BHEL make cast iron flanged sluice valve having equal to dia of suction pipe capable of withstanding normal seat pressure of 52 kg/ cm2 conforming to BIS 780-1984 with up to date ammendments in case of positive suction.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554(Part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter(one cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles,flexible pipe, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to aproval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost .
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(Part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to (one cable for carring all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipes, solder,nuts & bolts, cable glands etc. laid in pipes or trenches under floor. The type ,size & make will be subject to approval of HPSEB athorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost .
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L suction,delivery pipe considering site requirements , NPSH reqired & available & common header having area equal to times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. Away from the outer wall of pump house as per layout drawings approved by Engineer-in Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. Ie(ii). BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
Supply of antivibration pads conforming to BIS 6337-1971 or latest with up to date ammendmentsof suitable size for above machinery.
Errection of all equipments from S.No. 37 to 40, 42 & 44 i/c cost of tees, bends tapes & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Phase 2nd Dochi to Kot. Providing horizontal spindle,horizontal/redial split casing/and suction(Back-full out arrangements single/double/multi stage centrifugal pump or combination of pumps. In series/parallel of recommended make such as Mather and Platt/KSB/Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammend-ments read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor/motors of standard make such as Kirlosker/BHEL/Crompton/NGEF/GEC/Siemens/Jyoti and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts bolts and painting etc. and should meet the following requirements.
Duty Conditions Discharge 3.03 LPS Total Dinamic Head 629.75 Mtr. LWL in sump well 1670.00 Mtr. Shaft level 1670 Mtr. Level at discharge point 2230.00 Mtr. Suction lift 560.00 Mtr. Discharge Head 3.00 Mtr. Static Head 560.00 Mtr. Rising main Length = 2700 Mtr. Dia = 65 mm Pumping Hours 8 Hours Altitude of installation above MSL Nil. Charastrict of water : Raw water with turbidity upto 1250 PPM Tempreture 30 degree centrigrate
Providing ICTP Main switch with HRC fuses of Kilburn/L&T/siemens/Standard/Havells make and having capacity 30% extra of the operational rating as per IS: 4064:1978 with upto date ammendments immeidately after the power meter of the HPSEB. ICTP Switch Make Type Capacity
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capacable of mounting the following accessories withina ll internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities. Panel Switch Board Drawing Layout plan
i) MCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments. MCB/MCCB Make Type Range Capacity
II) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end. E.L.C.B Make Type Range.
(III) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition) Voltage Monitor Relay Make Type Range.
Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments. Power Fectoe Meter Type Make Range.
Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments. Frequency Meter Type Make Range.
Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments. Bus Bar Chamber Type Make Range.
ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments. ICTP Switches Type Make Capacity.
Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments. Three Phase Indicator Type Make Capacity.
Capacitor of crompton/L&T/NGEP make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments. Capacitor Type Make Range
Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS:1248( P-V) 1983 with upto date ammendments. Starter Type Make
Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.). Hour Run Meter Type Make Capacity.
Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. Antivibration Pads Size Make Material.
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments. Sluice Valve Make Class Seat Pressure.
Providng double flanged cast iron sluice valves PN-I of leader/BHEL Kirlosker/Kilburn GLED/fourses/ Kartar make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements. Sluice Valve Make Class Seat Pressure Material.
Providing double flanged swing type cast iron valve, PN-I of Leader/BHEL/Kirlosker/Kilburn/GLEd/Fourses/ Kartar make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments). Reflux Valve Make Class Seat Pressure Material
Providing double flanged cast iron reflux valves class PN-I of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES/ Kartar make and of 350 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments. Reflux Valve Make Class Seat Pressure Material
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments. Pressure Gauge Make Range.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments. Discharge Meter Make Type Range
Installation of all the items apparing at serial No.1 to 9 as per the systematic drawing.
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.1. The size of the various components to be as under: i) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe. ii) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe. iii) Common header : One dia higher then delivery of pump x 350 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed. Suction Pipe Material Grade Thickness Pressure rating. Delivery oioe and common header Material Grade Thickness Pressure rating.
Providing and laying copper PVC insulated arsoured power cable(One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens GLOSTER /IEC /ICC /EICD/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor. Arsoured Power Cable A. Motor Side (from switch to starter and starter to motor) Size Make Type Capacity Core B. Supply Side (from meter to HPSEB to bus bar and switch) Size Make Type Capacity.
Surjeet Singh Thakur
Raman Thakur Govt. Cont.
SURENDAR HANSRETTA
Bharat Engg and Suppliers
Thakur Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .