Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.8 LAccepted-AOC SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | 1 | Accepted-AOC lowest bidders | |
| 2 | 2₹30.1 L+₹22,719 (0.76%)Rejected-Finance 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | 2 | Rejected-Finance quoted rate are high | |
| 3 | 3₹32.9 L+₹3.1 L (10.4%)Rejected-Finance 173 RASTA PETH NIKHIL APARTMENT SHIRAL SETH CHOWK PUNE 411011 | PUNE | MAHARASHTRA | 411011 | 3 | Rejected-Finance quoted rate are high | |
| 4 | 4₹35.6 L+₹5.8 L (19.3%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | 4 | Rejected-Finance quoted rate are high | |
| 5 | 5₹35.8 L+₹6.0 L (20.1%)Rejected-Finance | 5 | Rejected-Finance quoted rate are high |
Tender Value
₹37.9 L
EMD Value
₹75,800
Closing Date
23 May 2023, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8410 PROVN OF CERTAIN SPECIAL REPAIRS, REVENUE WORK AND MINOR WORKS IN THE AREA OF MINTSD AND EME BN UNDER AGE EM SOUTH PUNE
2023_MES_591398_1
8410 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹75,800
Yes
5 Jul 2023
26 Apr 2023
25 May 2023
26 Apr 2023
23 May 2023
11 May 2023
Amount
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
M&L for point wiring for one light point/ fan point/ exhaust fan point controlled by one, one way switch using 1.5 Sqmm nominal cross sectional area copper conductor multistranded, PVC insulated unsheathed FRLS cable in and including rigid steel stove enamelled black ISI marked concealed conduit 20 mm dia or higher,16 gauge, complete with all ISI marked rigid steel stove enamelled black conduit accessories/ fittings and 1.5 sqmm nominal cross sectional area stranded copper conductor PVC insulated unsheathed FRLS green colour cable earth wire and connecting to earth dolly including cutting chases in stone / brick masonry walls and making good of disturbed surfaces complete all as specified and as directed. (Note :- The point wiring shall include the wiring of light/ outlets of any length from the distribution board via switch to the point.)
All as per item No. 4.00 above but for One 5A 3 pin switch socket outlet on same board complete all as specified and as directed.
All as per Ser. item No. 4.00 above but for One 5A, 3 pin switch socket outlet mutipurpose on independent board complete all as specified and as directed.
All as per Ser. item No. 4.00 above but wiring complete with 4.0 Sqmm nominal cross sectional area stranded copper conductor PVC insulated unsheathed FRLS wire for 3 pin 15 Amp socket multipurpose on independent board complete all as specified and as directed.
S & F for Piano switch flush type one way 6 Amps complete all as specified and as directed.
S & F for Piano switch flush type one way 16 Amps with neon indicator complete all as specified and as directed.
S & F for celling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked complete all as specified and as directed.
S & F for step type fan regulator 120 watt two module suitable for operation on 230 volt 50 HZ AC supply complete all as specified and as directed
S & F for piano socket, 6 Amps ,3 pin complete all as specified and as directed.
S & F for piano socket, 6/16Amps, 2/3 pin combination complete all as specified and as directed.
S & F for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified.
Supply and fix LED box type fitting pre-wired including LED tube 1x18/20W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed.
Supply and fix in repairs LED mirror light fittings wall mounted type suitable for 1x10 watt with high output diffuser and all fixing arangements conforming to Cat Part No BCLSB 10 WH of Bajaj or equivalant to Wipro / Havells complete all as specified and directed.
Supply fix MCB DB of sheet metal enclosure double door SPN 8 way with 200 Amps rated bus bar 230 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed.
S & F MCB SP 6-32 Amps, 240 V, 50 HZ, C series breaking capacity 10KA all as specified and directed.
S&F MCBs, SPN 40 to 63 Amps, 10 KA, IS/IEC 60898-12002 marked fixing in DBs complete all as specified and as directed. (Note : DBs catered separately in this Schedule under relevant item)
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr in deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level including connecting GI earth wire 4mm dia by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel for watering, PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in pit / chamber, RCC 1:2:4 type B0 using 12.5mm graded stone aggregates and 6mm dia mild steel bars at 100mm c/c as in chamber cover, charcoal, salt etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge. (Note : GI earthwire and GI protection pipe upto 7.5 mtr length shall be included in this item.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall including cutting chases in stone / brick masonry wall etc including one run of PVC insulated 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. (Note:- Three runs of 4.0 sqmm cable cable and one run of PVC conduit will be measured as one unit and Making good of disturbed surfaces will be done by contractor without any claims.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall including cutting chases in stone / brick masonry wall etc including one run of PVC insulated 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. (Note:- Three runs of 6.0 sqmm cable cable and one run of PVC conduit will be measured as one unit and Making good of disturbed surfaces will be done by contractor without any claims.)
M & L for Sub main wiring with approved colour coding as per IS with three single core PVC insulated FRLS cable with stranded copper conductor of size 6.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall including cutting chases in stone / brick masonry wall etc including Two runs of PVC insulated 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. (Note:- Five runs of 6.0 sqmm cable cable and one run of PVC conduit will be measured as one unit and Making good of disturbed surfaces will be done by contractor without any claims.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall including cutting chases in stone / brick masonry wall etc including one run of PVC insulated 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. (Note:- Three runs of 2.5 sqmm cable cable and one run of PVC conduit will be measured as one unit and Making good of disturbed surfaces will be done by contractor without any claims.)
Supply, lay, test, connecting and commissioning under ground cable, LT 1100 volts grade of size 35 Sqmm 3.5 Core, 1100Volt, heavy duty XLPE insulated, armoured with aluminium stranded conductor complete laid in trenches / fixed to poles / drawn through pipes with suitable size cable glands crimping type cable lugs etc complete all as specified and directed
S&F vertical 8 way TPN double door recess mounted / wall mounted MCCB's as incommer is 3 pole V-Tec of 100 amps rating & 16 KA breaking capacity MCCB is pre fitted at factory & including price of MCCBFP 100A fixed / flushed on wall incl cutting chases and making good of disturbed surfaces with PCC 1:2:4, type B-1 using 20mm graded stone aggregate complete all as directed and spd by engr in charge (Make :- Cat Part No DBVTH004SD of L&T equivalent to Havells/Legrand)
S&F Ceiling LED recessed Luminaire 600mmx600mm 35/36 Watt, 220VAC with high efficiency PMMA diffuser soft glare free light complete with driver holders & LED lamp suitable for roof, ceiling incl connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F exhaust fan 300 mm sweep, 230V AC heavy duty, ISI mark with metal frame with louvers, fixing on wall with nut bolts including making suitable size hole in wall of any type and making good as per existing surfaces for exhaust fans complete all as specified and directed
S&F industrial metal clad socket 2P+1N complete with metal clad 3 pin top and MCB SP 20A in sheet metal enclosure complete all as specified and directed.
All as per Ser. Item No. 29.00 above but tripple pole enclosure with 3 Pin & earth plug with socket, MCB TP 32 Amp complete all as specified and as directed.
All as per Ser. Item No. 29.00 above but tripple pole enclosure with 3 Pin & earth plug with socket, MCB TP 63 Amp complete all as specified and as directed.
S & F LED highbay 100 watt lumianaries a fine ventilation technology for better thermal management and its cutting edge LED technology with LED 100 watt and with flat white high transmission white/neutral white color temperature etc, prewired and all accessories including hanging arrangements such as steel wire rope SWR 2mm and clamping at any height and length with suitable size GI tube complete all as directed by Engr-in-Charge (Make : Cat part No. LH09-132-060-50-V5 of Wipro or equivalent model in Philips,Havells as approved by GE.)
Taking down Old unserviceable air termination rods with roof conductor aluminium / GI complete all as specified and as directed.
S&F Air termination single pointed, Aluminium rod, 12 mm dia and 300mm long complete all as specified and as directed.
S&F Bracket suitable for fixing of air termination rod made out from 50 mm bore GI pipe, medium grade 3.00 metre in length, made to shape as required, fixed on roof with PCC block of 1:2:4 type B-1 using 20mm aggregate including aluminium clamp to hold the air pointer rod at top of the GI pipe etc complete including necessary welding works, nuts, bolts & washer etc as required and as specified and directed.
M&L for laying of GI strip 32mmx6mm in trenches / Wall complete all as specified and as directed.
M& L for for Test point terminal block made of gun metal or phosphorous bronze size 75mmx75x25mm drilled and screwed incl three nos 8mm dia 25mm long hexagonal head screw encased in MS box of size 200mmx125mmx40mm of thickness 1.6mm all asspecified and directed
M&L for aluminium strip 25x3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground on wall complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr in deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level including connecting to and including 32x6mm mm dia GI strip upto 7.5 mtr by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel for watering, PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in pit / chamber, RCC 1:2:4 type B0 using 12.5mm graded stone aggregates and 6mm dia mild steel bars at 100mm c/c as in chamber cover, charcoal, salt etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge. (Note : GI earthwire and GI protection pipe upto 7.5 mtr length shall be included in this item.)
M&L for replacement of burnt winding of fans, rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing and overhauling incl replacement of ball and bush bearing and painting with white synthetic enamel paint after removing grease all as specified complete including taking down and refixing the fan at positions to the satisfaction of Engr-in-charge
Ceiling fan 1200/1400mm sweep working on 230 volts AC supply
Exhaust fan upto 380mm to 450mmsweep working on 230 volts AC supply
Wall mounting fan of 450mm to 600mm size,working on 230 volts AC supply
Supply and fixing Integral LED Security Light Luminaire 30 W comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame suitable for 50/40 mm GI Pipe (including GI pipe) of length 1.2m bend at 120 degree complete with accessories conforming to Cat Part No : HPLLEDSL3060S of HPL or of equivalent in Wipro/Philips/Havells/Fortune Art all as specified here-in-after including taking down old fitting.
Refixing of old serviceable earth continuity conductor or main earthing lead fixes to wall on batten or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any indicated GI strip /Aluminium strip 32x6mm & 25 mmx4mm complete all as specified and directed.
Excavating in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter depth and getting out in Soft/loose soil complete all as specified and as directed
Excavating in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter depth and getting out in hard/Dense soil complete all as specified and as directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all specified and as directed.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and as directed.
M&L for galvanised tubing 100 mm light grade with all fittings laid in trenches all as directed by engineer in charge.
Material and labour for sand cushioning with dry river sand /crushed sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as directed.
M&L for laying reinforced concrete pipes, class NP2 of dia 150mm, 2 nos half round (for bottom and top) and before laying UG cable in trenches exacaved area complete all as specified and directed Engr-in-charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm 3.5 core laid in trenches, road, path, culvert, wall & floors complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core laid in trenches, road, path, culvert, wall & floors complete all as specified and as directed.
Supply installation, commission and testing in replacement of outdoor type main control panel indoor type made out of CRCA sheet 3.15 mm thick (width of panel shall not be less than 60 cm in any respect ) with powder coated painting and four Nos 400 amps copper strip (not less than 40 mmx10 mm duly insulated mounted on insulators /suitable size backelite sheet) and comprising the following after removing exsting LT Panel complete all as specified and as directed :-
Shifting ,installation, testing and commissioning of LT control panel retrieved panel from Ser. No. 52.00 above, shifting and fixing at new location for augmentation of power supply duly grouting on PCC 1:3:6 type C-1 including welding of doors & painting of complete panel with synthetic enamel paint inside and outside all as specified and directed
M&L for cutting of existing road for laying underground XLPE cable and after laying cable making good the disturbed materials complete all as specified and as directed by Engr-in-Charge. (Note : Necessary permission for cutting of road shall be taken by Engr-in-Charge from Pune Cantt Board)
Supply and laying unreinforced PCC covers class LV,Type-I of size 250x150x40mm best quality laid dry in trenches for protection of underground cable all as directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trenches / fixed to poles / drawn through pipes with suitable size cable glands crimping type cable lugs etc of size 35.0 sq mm 4 core complete all as specified and as directed.
M&L for galvanised tubing 50 mm light grade with all fittings laid in trenches all as directed by engineer in charge.
S&F industrial metal clad socket 2P+1N complete with metal clad 3 pin top and MCB SP 32A in sheet metal enclosure all as specified and directed.
S&F tamperproof electric meter 10A to 60A, 230V, 50Hz, Class-I conforming to IS-13779, IP-54 with Parameters to show data, time, current reading, Load, PF and KWH etc connecting to existing electric supply system all as specified and directed
Taking down old unsv LED Luminaires and brought to E/M store all as specified and directed
Supply and fixing LED invertor batten 20Watt with lumens efficacy of 100 lumen /W 3.5 KV, Surge Protection, Power Factor >0.9, 6500k Model IVORA of Make Bajaj or of equivalent in Luker, Wipro complete all as specified and as directed.
S&F industrial metal clad socket 2P+1N complete with metal clad 3 pin top and MCB SP 25A in sheet metal enclosure grouted on walls complete all as specified and directed.
Supply, lay, test, connecting and commissioning under ground cable, LT 1100 volts grade of size 50 Sqmm 3.5 Core, 1100V, heavy duty XLPE insulated, armoured with aluminium stranded conductor complete laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands crimping type cable lugs etc all as specified and directed
Supply and fix air cooled, Inverter type, split unit air conditioner electric driven single phase of capacity of 2 TR, BEE 5 star rated, 230V, 50Hz, Single Phase, rated cooling capacity 20847 BTU/Hr, IS EER 5.05 with inverter Rotory Compressor, R-32 refrigerent, LCD remote display complete all as specified and as directed. (Make : Blustar / Hitachi / Carrier)
M & L for copper tubing, confirming to relevant IS, of size 5/8 & 3/8" flare size or nearest size, 3 core 2.5sqmm copper cable from ODU to IDU, PVC drain pipe from IDU to ODU and insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed by Engineer in charge.
Taking up UG cable of size 10 sqmm 2 core to 16 sqmm 4 core from trenches including bricks as required complete all specified and as directed.
All as per Ser. item No. 66.00 above but size 25 Sqmm/35/50sqmm 3.5 core complete all as specified and as directed.
All as per Ser item No. 66.00 above but size 70 /95 sqmm 3.5 Core complete all as specified and as directed.
All as per Ser. Item No. 66.00 above but size 120/150/185 sqmm 3.5 Core complete all as specified and as directed.
Supply and laying XLPE Insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core complete all as directed
All as per Ser. item No. 70.00 above but size 16 Sqmm 2 core complete all as specified and as directed.
All as per Ser. item No. 70.00 above but size16 Sqmm 4 core complete all as specified and as directed.
All as per Ser. item No. 70.00 above but size 25 Sqmm 3.5 core complete all as specified and as directed.
All as per Ser. item No. 70.00 above but size 70 sqmm 3.5 Core complete all as specified and as directed.
All as per Ser. item No. 70.00 above but size 95 sqmm 3.5 Core complete all as specified and as directed.
All as per Ser. item No. 70.00 above but size 120 sqmm 3.5 Core complete all as specified and as directed.
Laying only serviceable UG cable of size 10 sqmm 2 core to 16 sqmm 4 core in trenches retrieved under item ser No. 70 to 72 here in before complete all specified and as directed.
All as per Ser. item No. 77.00 above but size 25 Sqmm/35/50sqmm 3.5 core complete all as specified and as directed.
All as per Ser. item No. 77.00 above but size 70 /95 sqmm 3.5 Core complete all as specified and as directed.
All as per Ser. item No. 77.00 above but size 120/150/185 sqmm 3.5 Core complete all as specified and as directed.
M&L for cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for upto 50 Sqmm ,3.50 core complete all as specified and as directed.
M&L cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for size 70 Sqmm to 95 Sqmm, 3.50 core complete all as specified and as directed.
M&L cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for size 120 Sqmm to 185 Sqmm, 3.50 core complete all as specified and as directed.
Disconnection Elect Supply, taking down of burn / damage bus bar from LT panel and Supply & fixing in replacement air insulated aluminium bus bar with PVC sleeves and insulator of any size as reqd in existing panel , making holes as reqd ,suitable shape by bending and connecting to main bus bar/ MCCBs as existing position complete all as specified and as directed.
Taking up / down old steel tubing of sizes 40mm / 50mm / 80mm from road/wall complete all as specified and as directed.
Supply and fixing in replacement of GI Pipe , light grade 40 mm bore , confirming to IS-1239, for cable protection on poles/ walls/ Road crossing/ floor crossing complete all as specified and as directed.
All as per Ser. item No. 86.00 above but 50mm bore complete all as specified and as directed.
All as per Ser. item No. 86.00 above but size 80mm bore complete all as specified and as directed.
Laying only steel tubes light grade 40 mm on poles/ walls/ under Road / floor including retrieved from item srl No. 86.00 here in above complete all as specified and as directed.
All as per Ser. item No. 87.00 above but 50mm bore complete all as specified and as directed.
All as per Ser. item No. 88.00 above but size 80mm bore complete all as specified and as directed.
Disconnecting and taking up loop of underground cable, megger testing of dismantle LT cable of sizes of cross sectional area 10 to 16 sqmm 2/3, 5/4 core not more than 6mtr length and locating the fault and cutting the faulty damaged portion of cable , making with new straight through epoxy jointing kit with suitable size , including excavation, returning filling and all connected materials complete all as specified and directed. (Note :- Necessary excavation, sand cushioning, cable cover as bricks etc beyond 5 mtr should be measured and paid separately)
All as per Ser. item No. 92.00 above but size 25 Sqmm/35/50sqmm 3.5 core complete all as specified and as directed.
All as per Ser. item No. 92.00 above but size 70 /95 sqmm 3.5 Core complete all as specified and as directed.
All as per Ser. item No. 92.00 here in above but size 120/150/185 sqmm 3.5 Core complete all as specified and as directed.
M&L for Cutting the faulty/ damaged / burnt end portion of the U/G cables of crossectional area 10sqmm to 16sqmm 2/3, 5/4 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing its own position, including Insulation tape, nut ,bolts etc complete all as specified and as directed. (Note :- Necessary excavation, earth work should be measured and paid separately if reqd.)
All as per Ser. item No. 96.00 above but size 25 Sqmm/35qmm 3.5 core complete all as specified and as directed.
All as per Ser. item No. 96.00 above but size 50 to 70 sqmm 3.5 Core complete all as specified and as directed.
All as per Ser. item No. 96.00 above but size 95sqmm 3.5 Core complete all as specified and as directed.
All as per Ser. item No. 96.00 above but size 120/150 sqmm 3.5 Core complete all as specified and as directed.
S & F 1100 volts grade heavy duty flat cable of size 4sqmm 2 core , pvc insulated aluminum solid conductor , served with inner sheathing of pvc tape and overall PVC sheathed in service connections suspended by insulating hangers not more then 1 mtr apart including replacing 4 mm suspension wire , as directed by Engr-In-Charge.
All as per Ser. item No. 101.00 above but size 6 Sqmm 2 core complete all as specified and as directed.
All as per Ser. item No. 101.00 above but size10 Sqmm 2 core complete all as specified and as directed.
M & L for LT Danger notice plate of size 20 X 15 cm of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures, and conventional skull and bones, in signal red colour and fixed with MS clamps, bolts, and nuts of approved size complete all as specified and as directed.
S&F in repair Onload change over switch 200 Amps, 415 volt complete all as specified and as directed (Make : Havells cat No. IHCFFE0200 or equivalent make of L&T/Schneider)
S&F in repair Onload change over switch 100 Amps, 415 volt complete all as specified and as directed (Make: C&S/ Havells/L&T/Schneider)
M&L for Manual boring of holes under road, pavement, hard standing where ordered and incl inserting GI pipe 50 mm to 80 mm complete all as directed . (Note : - GI pipe 50/80 mm will be measured & paid seperately.)
RELIABLE ENTERPRISES
M/S - SUJIT ELECTRICALS
metro electrical services
CHAITANYA WINDWELL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .