RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Patient Bed (Fowler And Semi Fowler) ( 59 pieces ) Technical Specifications 1/9 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Performance Parameters Type of bed Fowler Fowler Number of bed platform sections 4 for fowler bed 4 for fowler bed Availability of Backrest section Yes * Backrest section linkage welded with MS CRCA tube (14 G) * Availability of Leg section Yes Yes Leg section linkage welded with MS CRCA tube (16 G) welded with MS CRCA tube (16 G) Mattress platform shall be perforated Yes * Screw mechanism welded with ERW MS tube (18 G) in M.S. cover made from (16 G) ERW tube * Manual adjustments Backrest
Requiredknee rest through two screw systems with thrust bearings individually manouvred by two handles for fowler bed Backrest
Requiredknee rest through two screw systems with thrust bearings individually manouvred by two handles for fowler bed Back rest - min 45 % of the frame length Yes * The bottom end of the H legs are provided with PVC shoes Yes in case of bed without castors Yes in case of bed without castors
RequiredNA in case of bed with castors The bed has head & foot panels detachable by hand without need of any tool Yes * Saline rod provision four locations on the bed platform to hold stainless steel Telescopic Saline rod 12mm dia with 15.87 mm dia x 1.2 mm (18 G) stainless steel * Provision for mounting of syringe pump outer covering tube with a knob to mount syringe pump * Finishing & workmanship shall be Yes * 2/9 of high standard All corners shall be rounded off so that there shall be no sharp corners and holes should be burr free Yes * Coating for metal parts M.S. tubular parts
Requiredlinkages
Requiredflats are to be In-house
Requiredpretreated shot blasted and Epoxy powder coated with coating thickness 50 to 100 microns * Material of handle SS SS
RequiredMS Number of detachable moulded PP with PVC insert head and foot side panels 4 * Provision of castors H' Type Legs with 600 mm Height with 125 mm(5") dia High Grade Synthetic Body Castors
Requiredtwo with brake
Requiredtwo w/o brake H' Type Legs with 600 mm Height with 125 mm(5") dia High Grade Synthetic Body Castors
Requiredtwo with brake
Requiredtwo w/o brake Number of hooks in Telescopic I V Pole 2 2
Required4 Urine Bag Holder Yes * Moulded Chart Holder Yes * Provision of mattress No * Number of sections in mattress 4 for fowler bed 4 for fowler bed Provision of collapsible Railing Yes Yes Material and Dimensional Parameters Overall Length of bed in mm with 5% tolerance 2050 to 2100 * Overall width of bed in mm with 5% tolerance 900 to 950 * Size of Buffer in mm 100 100 Bed Platform frame size with 5% tolerance 2070 mm L x 910 mm W * Mattress Platform size with 5% tolerance 1970 mm L x 790 mm W * Buffer to Handle Length with 5% tolerance 2275 mm * Fixed Height 600 mm * Material and size of 1.2 mm (18 G) CRCA * 3/9 section M.S perforated sheet top Overall length of Back Rest 800-825 775-800
Required800-825 Overall width of back rest 800-825 * Overall length of Knee Rest 400-450 350-400
Required400-450 Overall width of Knee Rest 825-850 750-775
Required825-850 Overall length of Leg Rest 550-600 * Overall width of Leg Rest 800-825 750-775
Required800-825 Overall length of Fix Section 100-150 100-150 Overall width of fix section 800-825 750-775
Required800-825 Raised Backrest Angle 65⁰ * Raised Kneerest Angle 40⁰ * Bed frame tube size 60 mm x 30 mm x 1.6 mm (16 G) Thick ERW tube * Dimensions for Fitting of frame ERW tubes diameter 31.75 mm x 1.2 mm (18 G) thick and diameter 22.22 mm x 1.2 mm (18 G) thick and MS sheet having thickness 3.0 mm (11 G) * Diameter of Four corner rubber buffers in mm 75 * Material of head and foot panels ABS Plastic * Diameter of MS tubular in mm 30 to 50 mm * Diameter of SS Laminated 30 to 50 mm * Patient Working Load 135 Kg * Safe Working Load 150 Kg * Thickness of PU foam of mattress in inch 4 * Density of PU foam of mattress in Kg/m3 NA (incase mattress is not provided ) * 4/9 Material of mattress cover of mattress NA (incase mattress is not provided ) * Colour of mattress cover NA (incase mattress is not provided ) Blue
RequiredNA (incase mattress is not provided ) Material of collapsing railing SS MS
RequiredSS Types of collapsing railing Collapsable Collapsable Reports Manufacturer Certificates ISO 9001:2015 * Details of manufacturer certificates such as number and date - * Availability of certificates of quality system ISO 13485 * Availability of test report from govt NABL/ILAC accredited lab covering all parameters No Yes
RequiredNo Test report number
RequiredIncase test reports not availabble
Requiredput NA - * Test report date
RequiredIncase test reports not availabble
Requiredput NA - * Name of test lab
RequiredIncase test reports not availabble
Requiredput NA - * Address of test lab
RequiredIncase test reports not availabble
Requiredput NA - * Copies of all certifications and reports to be provided to buyer on demand at time of supplies NA
RequiredIncase test reports not availabble Yes
RequiredNA
RequiredIncase test reports not availabble * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.