Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr Quoted ₹3.0 Cr | L1 | Accepted-AOC Selected as L1 and negotiated again to lower value and accepted and finalised. |
| 2 | L2₹3.2 Cr+₹22.0 L (7.39%)Rejected-Finance | ₹3.2 Cr+₹22.0 L (7.39%) | L2 | Rejected-Finance Found eligible in Technical and Financial done by committee found as L2 Vendor |
Tender Value
Refer Docs
EMD Value
₹7 L
Closing Date
10 Apr 2024, 3:00 pmClosed
Transport Commissioner
100 FEET ROAD MUDALIARPET PONDICHERRY
SELECTION OF CONTRACTOR FOR SUPPLY INSTALLATION COMMISSIONING AND MAINTENANCE OF SMART BUS SHELTERS IN PUDUCHERRY UNDER SMART CITY MISSION
2024_TDP_15656_1
959-2/TD/RTO(HQ)/Smart City/2024
Open Tender
Civil Works
Item Rate
30 days
REFER NIT DOCUMENTS
SELECTION OF CONTRACTOR FOR SUPPLY INSTALLATION COMMISSIONING AND MAINTENANCE OF SMART BUS SHELTERS IN PUDUCHERRY UNDER SMART CITY MISSION REFER NIT DOCUMENTS
2 documents required · 2 mandatory
₹5,250
Senior Accounts Officer
₹7 L
10 Oct 2024
16 Mar 2024
12 Apr 2024
16 Mar 2024
10 Apr 2024
16 Mar 2024
16 Mar 2024 - 21 Mar 2024
Amount
EARTH WORK
Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth up to 50m and lift up to 1.5m - All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the Cost of centering and shuttering - all work upto plith level - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for - foundations, footings, bases for columns
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix , including pumping of concrete to site of laying but excluding the cost of centering , shuttering finishing and reinforcement , including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete , improve workability without impairing strength and durability . Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work above plinth level upto floor V level
REINFORCEMENT
Steel reinforcement for R.C.C. work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Mild steel and Medium Tensile steel bars
STRUCTURAL STEEL WORK
Structural steel work riveted , bolted or welded in built up sections , trusses and framed work , including cutting, hoisting ,fixing in position and applying a priming coat of approved steel primer all complete
Laying and Jointing PVC Pipe. Heading
Designing , fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding , with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalization or rain screen principle as required , proper drainage of water to make it watertight including checking of all the structural and functional design b) Providing , fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metaliccolour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick) . The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved color and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws , nuts , bolts , washers , cleats , weather silicone sealant , backer rods etc. c) The fastening brackets of Aluminum alloy 6005 T5 / MS with Hot Dip Galvanized with serrations and serrated washers to arrest the wind load movement , fasteners , SS 316 Pins and anchor bolts of approved make in SS 316 , Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing . The item includes cost of all material &labour component , the cost of all mock ups at site , cost of all samples of the individual components for testing in an approved laboratory , field tests on the assembled working curtain wall with aluminium composites panel cladding ,cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation . Base frame work for ACP cladding is payable under the relevant aluminium items. The contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete as per the Architectural drawings, as per item description as specified, as per the approved shop drawings. However , for the purpose of payment , only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places.
ALUMINIUM WORK
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade (The item included cost of material such as cleats , sleeves , screws etc. necessary for fabrication of extruded aluminium frame work . Nothing extra shall be paid on this account)
PAINTING
Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface - water thinnable cement primer
Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10sq.m over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content - with ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams / litre
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams / litre , of approved brand and manufacture , including applying additional coats wherever required to achieve even shade and colour - Two coats
ROOFING
Supplying and fixing 0.45 mm thick colour coated tile profiled galvalume sheets of approved make and colour over the framework already erected, sheets fixed to the frame using special stainless steel extrusions, including all fasteners fixtures as per site requirement, applying silicone sealant wherever necessary so as to make the roof water tight at all heights as per manufacturer's Specifications and as directed by Engineer-in-Charge. - refer code NPSR
Providing and fixing galvalume sheets ridges and or hips which is matching to the tile profile sheet width 60 cm overall width plain G.S. sheet fixed with all fixing components liks hooks, bolts and washers etc complete of approved make and colour and thickness as per the instruction of Engineer in Charge -Refer code NPSR
Providing and fixing 15cm wide, 45 cm overall semicircular plain Galvalume sheet gutter matching to the tile profile sheet roofing with approved colour and make, with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2
FLOORING
Providing and laying flamed finish granite per sq.m stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as - flamed finish granite stone slab Jet black , Cherry red, Elite brown, Cat eye or equivalent
MISCELLANEOUS
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
Providing and fixing acrylic sheet having 4mm thick to the existing framework including all necessary fittings etc. complete as per the drawing and as per the direction of Engineer in charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type -lll of ASTM-D-4956-01 as approved by Engineer-in-Charge letters, borders etc. as per IRC: 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class ll of ASTM -D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position the all complete as per drawings, specification and direction of the Engineer-in-Charges. (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment ).Overhead informatory road signage
Bougainvillea
Bougainvillea
Miscellaneous
Miscellaneous
Electrical Works
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required. Group A
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing following size/ Modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2 +8 way, Double door
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
Statutory fee for availing single phase supply
Supply ,installation ,testing and commissioning of recess type 9 w LED light fitting
Supply installation testing and commissioning of single phase energy meter fabricated by 14 gauge GI sheet with all other accessories
Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun rise or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required1 output per phase and suitable for single phase supply
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
IT Equipment
2 MP IR Speed Dome Camera
4 Channel Network Video Recorder with 1 HDD Bay support 4# POE ports, HDMI, VGA and ONVIF
8 Channel Network Video Recorder with 1 HDD Bay support 4# POE ports, HDMI, VGA and ONVIF
Media converter with two LAN port
SC/LC patch card 1 mtr
6 TB Hard disk
12 TB Hard disk
CAT 6 Cable
6 U Rack
LED Lights
Pole with mounting bracket
PVC Pipes
1 KVA UPS with battery (30 min backup)
2 KVA UPS with battery (30 min backup)
43” LED TV with rigid enclose
GPS Clock
PIS System accessories for the installation
USB charging Sockets
Wi-Fi Router
Miscellaneous
Miscellaneous
FINEARTS COMMUNICATORS INDIA PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .