Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance GM PLAZA MA LINK ROAD SRINAGAR J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹89,000
Closing Date
19 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HQ 133 Wks Engrs
HQ 133 Wks Engrs PIN-914133 c/o 56 APO
PROVN OF BOREWELL AND ALLIED INFRASTRUCTURE AT BB CANTT
2020_MES_354523_4
CWEK-29/2020-21
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE 864 EWS
Class D Category a ii
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹89,000
Yes
HQ 133 Wks Engrs
25 Feb 2021
22 Jan 2021
22 Feb 2021
22 Jan 2021
19 Feb 2021
5 Feb 2021
22 Jan 2021 - 1 Feb 2021
1 Feb 2021
60 days
Amount
Materiral and Labour for Boring mm bore mild steel casing pipe in any type of strata including soft/hard rock by DTH/ODEX/Rotary combination rig and getting out for upto 25 mtr depth below ground level. Note:- (i) The diameter of the bore hole should be sufficient large enough for lowering well assembly of 200 mm casing pipe all as specified in IS-2800. (ii) The cost of casing pipe ,slotted pipe, and fittings shall be measured and paid seperately.
All as per serial item No.1 here-in-before but depth from 26 metre to 50 metre below ground level.
All as per serial item No. 1 here-in-before but depth from 51 metre to 75 metre below ground level.
All as per serial item No. 1 here-in-before but depth from 76 metre to 100 metre below ground level.
All as per serial item No. 1 here-in-before but depth from 101 metre to 125 metre below ground level.
All as per serial item No. 1 here-in-before but depth from 160 metre below ground level. Note for item No 1 to 6 :- (a) The exact location of bore well shall be based on report/ recommendation of Central Ground Water Board carried out. Same shall carried out by tenderer of proposed area. (b) The rate quoted by the tenderer shall be deemed to include from transportation of suitable truck mounted drilling with DTH/ODEX attachment alongwith necessary accessories and T&P and site clearance for setting machinery etc. (c) For the payment purpose only single unit of works for trial bore shall be measured and paid. (d) Test boring of size 125mm shall be done by the contractor prior to 200mm main boring to acertain the water depth and rates for the same shall be deemed to be included in the rate quoted against item No 1.00 to 6.00 above.
Yield test for the bore well by continuously pumping for 16 hrs to determine safe pumping yield.
Developing tube well with compressor of suitable capacity along with other arrangement including required tools, plants and equipments till sand free water of potable quality acheived for minimum period of 24 Hrs. including carring out Drawdown, verticality and aligment test of bore hole.
Supplying, assembling, lowering and fixing in position 200 mm nominal bore mild steel ERW type, ISI marked, casing blind pipe having wall thickness 8.00 mm as per IS-4270 : 1991 and jointing with electric arc welding in random length of 3 to 6 metre, jointing and painting with two coats of bituminous paint on external surfaces of pipe complete, all as specified and directed.
Supply, lowering and fixing in position heavy duty mild steel ERW slotted casing pipe 200 mm bore having thickness 8 mm as per IS-8110 : 1985 and slot size 0.75mm, area of slot shall be between 15 to 22% of screened area including jointing and welding of sockets complete, all as specified and directed.
Supply and fixing well cap fabricated out of 8 mm thick mild steel sheet for 200 mm dia bore pipe in two piece having 80 mm dia hole in centre with external bracket of flat iron of size 100 mm x 6 mm thick complete with nuts and bolts and washers etc including painting with two coats of black bitumenious paint complete all as specified and directed.
Supply and fixing casing shoe , 200mm dia including two coats of black bituminous paint over a coat of red zinc oxide primer complete, all as specified and directed.
Strata sample box made out of 20 mm thick veneered particle board and 12 mm thick ply wood with 25 mm x 25 mm aluminium angle 2 mm thick bearer, overall length 1200 mm x 750 mm x 100 mm with front glass sheet sliding type cover with aluminium frame all around 2 Nos key holes plate of size 40 mm x 25 mm and 3 mm thick complete showing name of tube well, location and strata sample with depth complete all as per specified.
Supply and lowering in borewell, MS ERW column pipe heavy duty, 100 mm bore in 3.00 metre length both end flanges screwed and welded complete with nuts, bolts, gasket etc. having wall thickness 6 mm or more, conforming to IS-1239 (Part - I) of 1979 with groves for passing the submersible cable and four number of grooves to accommodate the submersible cables and sling wires, 10 mm dia with sutable size of nuts, bolts, washers and rubber gasket complete all as specified and directed. Note :- All arrangement including required tools, plants and equipments required for lowering the column pipe in the bore shall be made by the contractor under their own arrangement at no extra cost.
Supply, lowering, connecting and commissioning of submersible pumpset radial flow multistages not less than 825 litre/minute discharged capacity at 130 metre head including suitable 40 HP submerciable motar, 5 star rated suitable to be lowered in 200 mm dia bore well, 415 /440 volts, 50 Hz, AC 3 Phase supply and having stainless steel body and stainless steel impeller complete all as specified and directed.
Supply and fixing flat electric cable of size 25 sqmm, 3 core, PVC insulated stranded copper conductor cable, 1100V, conforming to IS:694 for submersible pump motors including water proof joints with motor leads connected to panel board all as specified and directed.
Supply and fixing manually operated, heavy duty oil immersed star-delta motor starters type:SSD for 40 HP submersible pump including suitable copper thimbles for cable connection,water tape etc complete, all as specified and directed.
Supplying and fixing cast iron sluice valve, heavy duty, Class PN 1.6 with flanged ends, 150 mm nominal bore, ISI marked, any pattern with cast iron head wheels and stainless spindle, conforming to IS 14846 of 2000 including jointing material flanged joint, rubber/ fibre board gasket 6mm thick, mild steel bolt, washer, etc complete all as specified and as directed.
Supplying and fixing non return valve Cast iron heavy duty 150 mm dia,Class PN 1.6 with double flanged including nuts, bolts, washer and rubber packing gasket complete all as specified and directed.
Supplying, laying, jointing and testing galvanised steel tubing 150mm bore, ISI marked, 'Medium grade' with all fitting such as bends, elbows, tees, short pieces, union, etc., and fixing complete with clips, wall hooks complete all as specified and directed.
Supplying, laying and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 1100 Volts grade, cross sectional area 50 Sqmm 3.5 core, suitable for 11 KV earthed system, in trenches, floors, ducts passing through pipe for road crossing etc, including connecting & testing, complete, all as specified and directed. (Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured & paid for separately)
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 3.25 mtrs. deep below ground level) with top edge of the plate not less' than 2.5 mtrs. below normal ground level, connected to 25x4 mm earth strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel necessary earth work, drilling hole, RCC cover with handle, GI tubing medium grade 20 mm dia for watering, funnel wire mess GI bolts with washer of suitable size all as shown in electrical plate No 3 connected to earth test point all as specified or indicated incl. testing on completeion. (Note : Fresh soil will be used for filling the dug as required to achieve the desired resistance from out side, copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item GI wirebeyond 7.5 RM will be connected through double nut bolt and brazing of joints).
Material and Labour for PCC 1:2:4 type B1 in platform of size 1.50m x 1.50m x 0.50 m over leveled ground surface including removing the extra soil/mud of bore well in low lying area or as directed by Engr-in- Charge.
Testing of water sample by taking in clean container from borewell water and getting the same tested from the Govt approved laboratory for bacteriological and chemical test complete all as specified and directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth for foundation, shafts, man holes, etc not exceeding 10 Square metre on plan and getting out in hard/dense soil, complete, all as specified and as directed.
Returning filling in including spreding leveling watering and well ramming in layers not exc 25 cm each in soft/loose soil, complete all as specified and as directed .
Removing excavated soil to a distance exceeding 500 metre and not exceeding 1.00 Kilometre and deposited where directed complete, all as specified nad directed.
Supplying and fixing Cast iron specials fittings such as bends, tees, flanges, sockets etc.required at site for the execution of borewell work complete, all as per specified and directed.
Supplying and fixing single phase preventor with proper connection complete all as specified and as directed.
Material and labour for sub class brick laid dry width wise across the cable in trenches for protection of cable complete, all as specified and as directed.
Material and Labour for Fine and dry sand cushioning for underground cable by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including tretching the cable, complete all as specified and as directed. Note - Punned thickness of sand layer shall be measured and paid to contractor.
Housing clamp for 200mm dia MS ERW pipe made out of flat iron 100x12mm thick with required bolts, nuts washers including painting with two coats of black bituminous paint complete all as specified and directed.
M/S Gh Qadir
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .