| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹14.1 L+₹79,880 (6.01%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹15.4 L+₹2.2 L (16.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹16.0 L+₹2.7 L (20.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹18.0 L+₹4.7 L (35.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Nov 2022, 6:00 pmClosed
Lt Col Aditya Gorhe
GE Utility Bathinda Mil stn
REPAIR AND PAINTING OF LT POLES AND MAINTENANCE OF STREET LIGHT FITTINGS AT OTM ACCOMMODATION OF ZONE A UNDER GE(U) BATHINDA.
2022_MES_555953_1
8676/2022-23/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
class E cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹40,000
Yes
12 Nov 2022
4 Oct 2022
10 Nov 2022
4 Oct 2022
1 Nov 2022
18 Oct 2022
Amount
M&L for Cleaning and preparation of old painted surface of street light steel tubular pole 9.00 mtr long and painting with one coat of aluminum paint including brackets and making alternative black and white strips on pole with two coats of synthetic enamal paint (each strip 30 cm height) upto 1.5 mtr height from top of PCC foundation block and numbering of poles complete all directed.
M&L for Cleaning , preparation of PCC surface and painting with two coats of synthetic enamel paint and making altranative black and white strips 30 cm each up to 1.5 mtr height from top of PCC foundation block including numbering of poles of LT PCC Pole 9.00 mtr long complete all as directed.
Checking of non functional street light fittings any type on pole/wall to find out defect at site and making functional by repairing to cable connection/loose connection including necessary cleaning the bowl/perpex cover where provided and testing complete all as s directed. Note : (i) New spares required to repair the light fittings shall be measured & paid separately as supply only under respective item. (ii) The T&P Vehicles and necessry ladders etc will be arranged by the contractor and the cost of maint deemed to be included in the quoted rates. (iii) Contractor is bound to provide 2 Nos of Electrician and 4 Nos of helper for the subject work, the total strength should be devided in two teams for North and south area for daily basis, the rate of same is deemed to included in quoted rate by the contractor.
Supply only driver suitable for 45/60/120 watt LED with IP 65 protection, as per IS complete all as directed.
Supply and fixing in repair energy efficient LED street light fitting of 45 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver Driver should be potted with electrolytic capacitor of 105 degree and fiiting including making electrical connection complete all as directed. Make- Polycab/ havells/ Halonix/ Crompton/ C & S
All as per serial item No. 05 above but for LED street light fitting 60 Watt Make- Polycab/ havells/ Halonix/ Crompton/ C & S
Supply and fixing in repair energy efficient LED flood light fitting of 120 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver Driver should be potted with electrolytic capacitor of 105 degree and fiiting including making electrical connection complete all as directed. Make- Polycab/ havells/ Halonix/ Crompton/ C & S
Dismantling of old broken PCC pole of any size including broken PCC block and site clearance/staking complete all as directed.
Supply and erecting pre-stressed concrete poles 9 mtr long of cross section (102mmx172mm) at top and (102mmx279mm) at bottom, class-10 complying with requirements of IS-1678-1978 in perfect vertical position, embedded in PCC foundation and coping, including applying two coats of cement base paint on PCC coping complete all as directed. Note: (i) PCC and earth work shall be measured and paid for separately under respective item. (ii) The T&P vehicles will be arranged by the contractor for transporting the pole and the cost deemed to be included in the quoted rates.
M&L for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation of electric poles/struts etc including necessary formwork complete all as specified and directed. Note: Volume of poles/struts embedded in concrete shall be deducted during calculation the quantity of PCC for foundation )
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of electric poles/struts etc including necessary formwork complete all as specified and directed. Note: Volume of poles/struts embedded in concrete shall be deducted during calculation the quantity of PCC for coping.)
S&F in repair service wire PVC insulated stranded aluminium conductor, served with inner sheating of PVC tape and overall PVC sheathed of Size 6 Sqmm twin core flat, 1100 volts complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, laying of cables or pipes (where provided) and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed .
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as directed.
Laying only old serviceable under ground PVC/XLPE LT cable of any grade , any size laid in trenches / fixed to wall / pole / roof / laid in floor including necessary connections and thimbling complete all as directed.
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed.
All as per serial item No. 16 above but for cross sectional area 16 Sqmm 4.00 core Note for serial item No. 14 to 17: (i) Earth work shall be measured and paid separately under respective items.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all specified and as directed.
M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm complete all as directed.
Supply and laying well burnt sub class B breicks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
All as per serial item No. 21 above but using old serviceable bricks.
Opening /disconnecting the electrical connection of defective/burnt out main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junction box/LT panel/ O/H line complete all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks protection and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra shall be paid on this account. (i) Additional cable/ protection pipe required at site shall be measured and paid seperatly under respective item.
S&F in repair junction box ,size not less than 200mm x 160mm x 98mm, insulated type , made out with Polycarbonate with glass fiber reinforced with MCB SP 'C' curve 2.5 Amp complete all as directed. Make: Hensel, Cat Part No. KF5255 / HANSON/ Siemens / GE Power/ Rittal. Note :- (i). Manufacturer should submit routine test certificate for CJB/PJB (ii).The Polycarbonate Junction Box shall be environment friendly, recyclabe, UV resistant, halogen & silicon free, anti acid & anti corrosive. (iii). The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529. (iv).The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. (v).The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60988 - 2 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. (vi). The Junction Box color according to RAL 9011. (vii).The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For beter safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechnical load shall be in accordance with EN 50298 - 98 for IK 08.
S&F in repair MCCB, 3 phase, 4 pole, 415 volt of capacity 63 Amp, short circuit, breaking capacity not less than 16 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed.
S&F in repair MCCB, 3 phase, 4 pole, 415 volt of capacity 32 Amp, short circuit, breaking capacity not less than 16 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed.
S&F in repair MCB 'C' Curve, TPN ,240Volt, 63 Amp 10KA all as specified and as directed.
S&F in repair MCB 'C' Curve, SP ,240Volt, 6 to 20 Amp 10KA all as specified and as directed.
S&F in repair MCB 'C' Curve, SPN ,240Volt, 20 Amp 10KA all as specified and as directed.
S&F in repair AC coil for C1 series contactor suitable for operation of timer with operating voltage 240 volt as specified and directed.
Cutting / trimming of tree branches upto 1.50 metre distance on each side and 3.00mtr distance on both sides of LT over head lines including collection and removal from road complete all as directed. Note : For measurement and payment purpose each span shall be considered as 40.00 mtr. Span.If the length of span is less than 40.00 mtr measurment and payment shall be considered proportionally.
M&L for making the horizontal boring under road and hard standing suitable for laying and inserting pipe upto 80 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface complete all as specified and directed. Note: GI pipe shall be measured and paid separately under respective item.
Supply and laying GI tubing, light grade, 50 mm bore complete with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/along wall/under road/across the drain complete all as specified and as directed.
Supply and laying in repair GI tubing, light grade, 40 mm bore complete with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/along wall/under road/across the drain complete all as specified and as directed.
Taking down the lanteren carrige assembly along with lanterns after replacement of worn out pully at top section of high mast ,welding putting the fell down wire rope in pully groves in proper alignment for satisfactory operation of winch system by arranging hydraulic crane from civil market having boom suitable for working at 16 mtr height and carrying out work complete all as directed by Engineer-in-Cahrge . Note:- (i). Cost of hiring of hydraulic crane suitable for working at above 16 mtr height and T&P used for repair of high mast is deemed to be included in unit quoted rate.
Rewinding of motor 2 HP ,3 phase ,415 volts ,1425 RPM with copper wire of existing size and varnishing and testing complete all as directed.
S&F in repair Bearing SKF 4026 complete all as directed.
S&F in repair decorative circular design type of Post top Lantern of 45 Watts LED type resistance to impact & corrosion, IP 65 protection, heat sink, system efficiency > 100 lmn/ W, CRI between 80-90, color temp 5000-6000 K, with LEDs and Driver complete all as directed. Make :Bajaj/ CG/ Halonix/ C&S/Philips/Polycab
All as per serial item No. 39 above but for Post top Lantern of 30 Watts LED type . Make : Bajaj/ CG/ Halonix/ C&S/Philips/Polycab
Un binding from old insulators and taking down old unservicable insulators and re–stretching only existing ACSR of any size on LT poles including binding the ACSR with new insulators with and including aluminium binding wire 2mm dia complete all as specified and as directed. Note :- (i) The rate of aluminium binding wire 2mm dia is included in this item and nothing shall be paid extra on this account. (ii) New insulators shall be measured and paid seperately under respective item of this scheule of works of BOQ.
Supply , fixing and stretching in repair ACSR of any size as per site requirement on existing HT/LT poles including binding on existing insulator with aluminium binding wire 2mm dia complete all as specified and directed by Engineer-in-charge. Note :- 1. For measurement and payment purpose only the weight of ACSR shall be considered .The weight of aluminium binding wire 2.00mm shall not be considered. 2. The rate of aluminium binding wire 2.00mm is included in this item and nothing shall be paid extra on this account.(ii)(ii) New insulators if required shall be measured and paid seperately under respective item of this scheule of works of BOQ.
Supply and fix in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. Note : The rate of one primer coat, one under coat and one finishing coat of paint is included in this item.The payment shall be made as per actual weight of material. During weighting the weight of paint and primer shall not be considered for payment purpose.nothing shall be extra paid on this account.
Supply, installation, testing and commissioning in replacement of maintenance free earthing (grounding) electrode of size 85 mm Dia x 3 Mtr long with 17.2 mm Cu bonded MS conductor in high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Electrode made of conductive earth enhancing material mixed with cement in the ratio (3:1) backfill the voids surrounding the 17.2 mm Cu Bonded MS conductor or other metal components placed in augured bore hole of 100mm dia x 3 Mtr depth, resulting to increase in the effective surface area of the earth electrode or grids to lower the resistance. Earth enhancing matetial should not leach chemicals into the adjacent soil or underground water channels and should be in pH neutral range. Earth enhancing material should permanently protect the encased metal components of the earthing system, copper bonding on MS rod should be minimum 250 microns. All hardware like nuts, bolts and washers should be of stainless steel. Electrode should withstand fault current upto 35 KA for 1 second. Electrode's top terminal be sealed permanently packed with conductive concrete and Cu bonded copper strip of size 32mmX 6mm taken out be terminated on to earth test point and equipment terminal upto 7mtr length. Test certificate of NABAL laboratory shall be submitted by the contractor, test link of size 50 mmX 6 mm X 200 mm, RCC pit cover test point complete, all as specified and directed by Engineer-in-Charge. Make: Elancrete Note :- (i) Test certificate of earthing material from certified NABL laboratory shall be submitted. (ii) Test Reports Should Not be more than 7 year old. (iii)Test Report for Fault Current,Rohs compliance, Resistivity value from NABL certified/ CPRI lab is must be submitted.
PREM ENTERPRISES
Sandeep Enterprises
M/s Kataria Construction Company
MODERN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .