Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹27.5 L+₹2.1 L (8.46%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹30.1 L+₹4.8 L (18.8%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹33.0 L+₹7.6 L (30.0%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
9 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS AMRITSAR
DAY TO DAY COMPLAINTS OF EXTERNAL ELECTRIC SUPPLY AND ALLIED WORKS AT NAMS
2022_MES_544617_1
GE NAMS-29/2022-23
Open Tender
Civil Works
Item Rate
330 days
GE NAMS
CLASS D CATEGORY b(ii)
7 documents required · 7 mandatory
₹500
GE NAMS
₹77,000
Yes
27 Sept 2022
11 Aug 2022
12 Sept 2022
11 Aug 2022
9 Sept 2022
26 Aug 2022
Amount
Day to day attending complaints & maintaining the electric supply GE NAMS Area round the clock (24 Hours) comprising the following HT /LT net work / transformers / LT panels by contractor/his rep with fwg networks:-
(i) Feeder No-1 emanating from 66 KV grid Sub station to TOP II, Appx length – 4.5 Km.
(ii) Feeder No-2 emanating from 66 KV grid Sub station to NME, Appx length = 1.8 Km, LT Panels , LT overhead lines appx – 2.50 km and 01 No transformer.
(iii) Feeder No 03 emanating from TOP I Sub station to Old Officer colony Feeder, Appx length = 3 Km along with 08 transformers with GOD s of different capacities , LT Panels , LT overhead lines appx – 4.5 km.
(iv) Feeder No 04 emanating from TOP I Sub station to Back Feeder Appx length = 3 Km along with 07 transformers of different size, LT Panels GOD's, LT over head line appx 4 Km.
(v) Feeder No 05 emanating from TOP II Sub station to Old Kathania Accn Appx length = 2 Km along with 06 transformers GOD'S, LT Panels, LT over head line appx length 4.5 Km with cable/service connections.
(vi) Feeder No 6 emanating from TOP II Sub station to Back Feeder to Army school, central school Appx length = 3.5 Km along with 05 transformers of different cap with GOD's, LT Panels, LT over head line appx 1.5 Km.
(vii) Feeder No 7 emanating from TOP II Sub station to New officer Colony: & OTM 54 Bde HQ, 21 Kumaon,18 JAK, 415 Fd Hosp and 9 PUNAJB Appx length = 4 Km along with 08 transformers of different size with GOD's, LT Panels, LT over head line appx 3 Km with cable/service connections.
(Viii) Feeder No 8 emanating from TOP II Sub station to NOC II, Appx length = 1 Km along with 01 transformer with GOD's, LT Panels over head line appx 2.5 Km.
(ix) Feeder No 9 emanating from TOP II Sub station to CP -6 baffle range Appx length = 4 Km along with 02 transformers of different size with GOD's, LT Panels, LT over head line appx 0.5 Km.
(x) HT feeder No 10 emanating from 66 KV Sub station to New Red Colony, New Kathania & NOC-I Appx length = 2.5 Km along with 06 transformers of different size with GOD's, LT Panels, LT over head line/UG Cable appx 3 Km with cable/service connections.
Preodicity - round the clock
(B) Nature of work to be done -
(i) Maintaining the serviceability and attending break down complaints of electric supply of all the feeder including of New ASR Cantt area mentioned under Sl 2.01(i) to 2.12(xii) here in before .
(ii) Attending the complaint of external electric supply – from pole to main board / DB of the occupant .
(iii) Periodical maintenance/complaints of all the feeders mentioned here-in-before which includes – (a)Replacement of overheated jumper / blown off jumpers .
(b) Replacement of blown off HT fuses .
(c ) Periodical complaints of LT panels .
(d) List of T&P to be provided for each electrician by the contractor without any extra cost i.e. the cost of the undermentioned itiems are included in the quoted rate are as under :- (i) Screw Driver Set - 01 Set for each electrician. (ii) Cutting plier - 01 Nos for each electrician. (iii) Hack saw with balde - 1 Nos for each electrician. (iv) Open Jaw spanner set of 14 Spanner - 1 set for each Electrician (v) closed jaw spanner set of 14 spanner - 1 Set for each electrician. (vi) Club Hammer for electrician - 1 for each electrician (vii) High power torch - 02 Nos (vii) Line man safety belt for electrician - 1 Nos for each electrician (viii) Clamp meter - 01 Nos for each electrician (ix) Discharge Rod - 01 Nos (x) Magger 5000V- 1 Nos
(xi) Rain Suit - 01 Nos to each person (xii) Rain Shoes- 1 Pair to each person (xiii) Bamboo Ladder 28 Steps - 04 Nos (xiv) Bamboo ladder 24 Steps- 04 Nos (xv) HT hand gloves- 01 Pair to each person. (xvi) Electrician tool bag kit- 1 for each person. (xvii) MAN/ ELECTRICIAN ON WORK board with hanging arrangement - 5 Nos Note:- All the items shall be purchase by the contractor in advance and lay out in Office for checking of Engr-in-charge before issue to electrician. If any item found defective or unsv it will be replaced by the contractor throught the period of contract. A panelty of Rs 1000 Shall be imposed on the contractor if any item found defi in electrician tool bag kit at any time by any Inspecting/ checking officer. A time of 48 hours will be given to the contractor for replacement / make up of items and if he fail to give the items again panely of Rs 1000 shall be imposed from his dues and the process continues till contractor provide tools and give completion on his letter pad.
(e) Contractor provide one No mobile phone without camera to the complaint cell and resposible for recharge of the same for the period till the completion of contract. A Panelty of Lump Sum Rs 5000/- shall be imposed on the contractor from his dues if the same is not provided or not recharged by the contractor. rate for the same shall be included in the quoted rate.
(f) Complaint to be attended within 1 to 2 hrs otherwise penalty to be made at @ Rs. 500/- per complaint.
(g) Complaint Register & complaint slip shall be provide by the contractor wihout any extra cost paid to him and maintained by the SBA on duty/ Contractor rep present at Complaint cell in supervison of JEEM and signature of JE / Engr in charge will be taken on each complaint after completion of complaint on daily basis also take following detail on complaint slip after completion of complaint such as Army No , Rank , Name, Mobile No , unit and Signature without signature complaint slip will not be accepted and no payment shall be paid to the contractor for such complaint slip. Note :- No extra cost shall be paid to the contractor for complaint register and complaint slip.
Note – (i) Time consuming jobs such as replacement of defective cable by extension of loop and periodical trimming of trees / branches along the over head lines shall be measured and paid separately . (ii) Before attending any complaints of external elect supply contractor or his rep shall ensure that proper shut down has been taken in physical presense on permit slip and will be lifted on the same permit by the physical reporting at Sub station with proper time and signature. Note . No shut down given/ lifted on mobile phone. Shut down shall be given / lifted only after physical reporting of electrician at power house (iii) All safety precaution will be taken by the Contractor/his rep. incase of any physical injury / any mishappning contractor is responsible for all the medical treatment and compansation to the individual . No extra cost paid to the contractor for the same. (iv) Contractor will provide shut down permit book for taking shut down permit from the JE/ Engr-in-Charge on duty. No extra cost will be paid for the same.
Excavation trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5m/in width & not exceeding 3m in depth for and getting out in any of soil complete all as specified and as directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 7 here-in-before but of size 120 Sqmm 3.5 core.
All as per srl item No 7 here-in-before but of size 50 Sqmm 3.5 core.
All as per srl item No 7 here-in-before but of size 35 Sqmm 3.5 core.
All as per srl item No 7 here-in-before but of size 25 Sqmm 4 core.
All as per srl item No 7 here-in-before but of size 16 Sqmm 4 core.
All as per srl item No 7 here-in-before but of size 16 Sqmm 2 core.
Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge of size 50mm outer dia and 38mm inner dia
------Ditto all as per items No 14 but of size 77mm outer dia and 63mm inner dia for
-----Ditto all as per items No 14 but of size 90mm outer dia and 75mm inner dia
Supply and fixing in replacement danger notice plate of 1.6mm thick mild steel sheet , virtreous enameld white, with letters , figures and conventional skull and bones in signal red colour(in three language) and fixed with MS clamps , bolt and nuts of approved size for LT 20 X 15 CM size complete all as specified and directed.
Ditto all as per items No 21 but for 66 KV/11KV HT of size 25 x 20CM
Excavates and relaying cables loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
S & F in replacement end termination joint cold shinkable type suitable for 3 core 11000 volts XLPE HT UG cable of size 120 Sq mm to 185 Sq mm complete all as specified and directed.
Material and Labour in replacement straight through joint/End temination kit of heats shrinkable suitable for above 185 sqmm to 300 sqmm HT 3 core 11000 volts XLPE cable type complete all as specified and directed.
Supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-31 ( 9 mtr long) erecting in position all as specified/shown on drawing and as directed by Engr-in-Charge Note: (i) Excavation Earth work and foundation will be measured and paid seperately under relevent items.
Supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-55 ( 11 mtr long) erecting in position all as specified/shown on drawing and as directed by Engr-in-Charge Note: (i) Excavation Earth work and foundation will be measured and paid seperately under relevent items.
M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
Material and labour in replacement for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
Supply & fixing in replacement of LT stay assembly comprising of 7/3.15mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessary Excavation and PCC all as specified and directed by Engr-in charge
S&F in replacement loop type porcelain white, brown or green small size with cover dimensions of 65x 90 mm clearance of whole 16 mm as specified and directed by Engr-in charge.
S/F galvanised steel stranded stay wire size 7/4mm for stay assembly
Replacement of pin type polymer/porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height,65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
S & F in shackle type,vetrious Insulator incl one galvanised mild steel spindle, two galvanised iron washerrs,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt,and as directed by engineer in charge.
Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of Engr in charge
Supply and fill up transformer oil topping up having dielectric strength not less than 50 KV at 4 mm gap conforming to IS complete all as specified and directed.
Supply & fixing in replacement Pin/Disc type type polymer insulator including one galvanised mild steel straps, washers and nut for 11000 volts grade, including removal of existing insulators complete all as specified and directed.
S & F in replacement of guard wire with galvanised steel wire 4mm dia for HT/LT OH line complete all as specified and directed by Engineer-In-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009.
Supply and fixing in replacement of male female contacts of gang operative switch made out of brass and rated capacity 200 amps ,make matching with the existing switch complete all as specified and directed .
Supply and fixing in replacement of copper ribbon suitable for 200 amps rated capacity gang operative switch, 45 CM long complete all as specified and directed .
M&L for highly resistant insulating rubber mat suitable for 11 KV , Class B, 2.5mm thick complete with fixing using glue on flloor of power house all as specified and as directed Make
M&L for grease suitzable for 11 KV equipment complete all as specified and as directed by Engr-in-Charge
S&F in replacement HRC fuse suitable for VCB 630 Amp , 11 KV compete all as specified and as directed.
S&F in replacement air break switch insulator , 200 Amp , 11 kv complete all as specified and as directed.
S&F in replacement spindle suitable for 11 kv Pin insulator complete all as specified and as directed.
Material and labour for PCC 1:3:6 type D-2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified.
Material and labour for PCC 1:2:4 type B-1using 20mm graded broken stone aggregate for coping pedestal of poles incliuding necessary form work fair finished to exposed surface.
Taking out carefully manually by excavation of existing cable of any size HT/ LT with loops and relaying with old retrived brick complete the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) HT/LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling.
Supply & fixing in replacement of MCCB Capacity 36 KA 4 pole 630 Amps adjustable thermal magnet to release type with preader and aluminium lugs all as required at site.
-do- but 500 Amp 36 KA
-do- but 400 Amp 36 KA
-do- but 250 Amp 36 KA
-do- but 350 Amp 36 KA
-do- but 200 Amp 25 KA
-do- but 160 Amp 16 KA
Material and Labour in replacement straight through joint heats shinkable suitable for upto 50 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour in replacement straight through joint heats shinkable suitable for 70 sqmm to 120 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour in replacement straight through joint heats shinkable suitable for 185 sqmm to 300 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and labour for reconditioning of battery including changing of all cells and external portion and battery terminal for power back up system at MES Power house ,12V , 180Ah complete all as specified and as directed by Engr-in-Charge.
Prunning of trees of over head HT/LT lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge.
Supply and replacement HT 11 KV bush rod suitable for indoor / outdoor type 250 to 315 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed.
All as per Srl item No 59.00 here-in-before but suitable for 160 to 200 KVA transformer.
Supply and Fix high grade PVC LT overhead phase to phase line spacer suitable for 3 lines , suitable for verticale and horizontal line complete all as specified and as directed.
Supply and Fix high grade PVC LT overhead phase to phase line spacer suitable for 5 lines , suitable for verticale and horizontal line complete all as specified and as directed.
Supply and fixing in replacement aluminium thimble of size 50 sqmm
Supply and fixing in replacement aluminium thimble of size 95 to 120 sqmm
Supply and fixing in replacement aluminium thimble of size 185 to 240 sqmm
Supply and fixing in replacement aluminium thimble of size 300 to 400 sqmm
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 16 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Material & labour for 2 Pole structure complete painting to mild steel cross arms, bracing, supports, clamps, back plate etc fixed on HT Poles any height with providing two coats of aluminium paint over a coat one coat of red oxide primer complete all as specified and directed. Note:- One 2 pole mild steel struture complete on HT PCC pole steel members fixed thereon shall be considered as 'One Unit'.
Painting of PCC poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping ovdirer a coat of primer including Numbering of poles as directed by Engr-in-Charge
Material and labour for tinned copper fuse wire 22 SWG to 35 swg, 5 Ampere to 24 Ampere (14 sizes ), each roll weight from 125 to 150 gm , sutable for fuse wire complete all as specified and as directed.
Material and labour in replacement of LT fire resistant PVC self adhesive electrical insulaion tape (Red, Yellow, Blue & Black) high quality size minimum 7 mtr long x 1.8 CM width complete.
Supply and fixing out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch, mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 200 amps and all accessories ie pipe clamp etc complete, all as specified and directed.
M&L for HT lightening arrestor for outdoor use, expulsion type, POLYMER complete with all fittings, transmission class, discharge capacity 65kilo amps, minimum working pressure 11000 volts grade conforming to IS complete all as specified and directed
Material and labour in replacement for HT fire resistant, flame retardant self adhesive electrical insulaion tape suitble for 11KV (RYB), high quality size minimum 19mm x 60 Ft complete.
Material and labour for drawing of old faulty cable from existing DWC pipe and make them serviceable and reconnecting it into its original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) HT/LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling.
M/s MAHAJAN CONSTRUCTION CO.
Bharat Builder
kailu construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .