| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.6 LAccepted-AOC | L1 | Accepted-AOC Responsive | |
| 2 | L2₹91.7 L+₹12,073.76 (0.13%)Rejected-Finance JATIA GUWAHATI | GUWAHATI | L2 | Rejected-Finance Financially Non Responsive | |
| 3 | L3₹93.8 L+₹2.1 L (2.34%)Rejected-Finance | L3 | Rejected-Finance Financially Non Responsive | |
| 4 | L4₹1.1 Cr+₹21.9 L (23.9%)Rejected-Finance | L4 | Rejected-Finance Financially Non Responsive | |
| 5 | L5₹2.1 Cr+₹1.2 Cr (126.0%)Rejected-Finance 4TH FLOOR LB PLAZA G S ROAD BHANGAGARH GUWAHATI 781005 ASSAM | KAMRUP METRO | ASSAM | 781005 | L5 | Rejected-Finance Financially Non Responsive |
Tender Value
Refer Docs
EMD Value
₹3.8 L
Closing Date
1 Dec 2020, 4:00 pmClosed
CGM(D),APDCL,CAR
O/o the CGM(D), APDCL,CAR,Bijulee Bhawan, Guwahati
R and M of 33/11 kV, 3.15MVA Harangajao S/S along with construction of new control room building and with available APDCL Supply materials, under Halflong ESD of KANCH El. Circle on Partial Turn Key Mode
2020_APDCL_19203_1
CAR/R-M/HarangajaoSS/2020
Open Tender
Composite Works
Turn-key
180 days
Harangajao S/S, Halflong ESD, of Kanch El Circle
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹3.8 L
1 Mar 2021
6 Nov 2020
2 Dec 2020
6 Nov 2020
1 Dec 2020
12 Nov 2020
9 Nov 2020 - 23 Nov 2020
R&M of 33/11 kV,3.15MVA Harangajao S/S along with installation of an additional 1x2.5MVA PTR and construction of new control room building (with available APDCL Supply materials) under Halflong ESD of KANCH Electrical Circle on "Partial Turnkey Mode", under R&M Scheme.
Description of Work / Item(s)
R&M of 33/11 kV,3.15MVA Harangajao S/S along with installation of an additional 1x2.5MVA PTR and construction of new control room building (with available APDCL Supply materials) under Halflong ESD of KANCH Electrical Circle on "Partial Turnkey Mode", under R&M Scheme.
Description of Work / Item(s)
R&M of 33/11 kV,3.15MVA Harangajao S/S along with installation of an additional 1x2.5MVA PTR and construction of new control room building (with available APDCL Supply materials) under Halflong ESD of KANCH Electrical Circle on "Partial Turnkey Mode", under R&M Scheme.
Installation of Battery Charger suitable for 150 AH, 110 V Battery Bank
Installation of DCDB
Installation of ACDB
Supply and Installation of 110 Volt , 150 AH Battery Bank with sealed maintnace free valve regulated lead acid batteries with multi tier wooden mounting rack of teak/sal wood planks of minimum 25mm thickness
Installation of 33 KV outdoor installation type VCB with terminal connector & GI mounting structure
Installation of 33 KV 1 phase CT with GI mounting structure & marshaling Box ( Set comprising of three units) 200-100/5-5 Amp
Installation of 33 KV 10 KA lighting arrestor with surge monitor & GI mounting
Installation of 33 KV 10 KA lighting arrestor with surge monitor & GI mounting
Installation of 33 KV 800 Amps Double break isolator without earth switch with terminal connector & GI mounting structure
Installation of 33 KV C&R Panel for Transformer ( with differential realy numerical type & with static TVM)
Installation of 33KV/110 V, 1 ph PT with GI mounting structure & marshling Box ( Set comprising of three units)
Installation of 33/0.4 KV 100 KVA transformer
Installation of 33 KV DO fuse 150 Amp
Supply and Installation of 33 KV Gang Switch 500 Amp
Installation of 33 KV 10 KA lighting arrestor with surge counter & GI mounting
Supply and Installation of 33 KV Combined CT PT set
Supply and Installation of HT Trivector meter ( Category C)
Installation of 11 KV outdoor VCB with GI structure & marshalling Box
Installation of C & R panel for 11 KV outdoor VCB
Installation of C & R panel for 11 KV outdoor VCB
Installation of 11 KV outdoor CT for Incomer with GI structure & marshalling Box 600-300/5-5-5 Amp
Installation of 11 KV outdoor CT with GI structure & marshalling Box 200-100/5-5 Amp
Installation of 11 KV outdoor CT with GI structure & marshalling Box 200-100/5-5 Amp
Installation of 11 KV 630 Amp Double break Isolator with earth switch with terminal connectors & & with GI mounting structure
Installation of 11 KV 630 Amp Double break Isolator without earth switch with terminal connectors & & with GI mounting structure
Supply and Installation of 11 KV outdoor PT with marshaling Box & GI mounting Structure
Installation of 12 KV, 9 KA station type ligtening arrestor with surge monitor
Installation of 12 KV, 9 KA station type ligtening arrestor with surge monitor
Supply and Installation of Control cable copper 10 core x 2.5 sqmm
Installation of Control cable copper 7 core x 2.5 sqmm
Installation of Control cable copper 7 core x 2.5 sqmm
Supply and Installation of Control cable copper 4 core x 2.5 sqmm
Installation of Control cable copper 2 core x 2.5 sqmm
Installation of Control cable copper 2 core x 2.5 sqmm
Supply and Installation of PVC Cable 1 core 2.5 Sqmm copper cable
Supply and Installation of LT XLPE cable 1 core 120 Sqmm
Supply and Installation of Bi metalic lug (Assorted)
Supply and Installation of GI Channel cross arm (100x50x6x2200)mm
Supply and Installation of GI Channel cross arm (75x40x6x2200)mm
Supply and Installation of GI Channel (100x50x6)mm
Supply and Erection of Sub-Station structure using GI Steel tubular pole SP 66
Supply and Installation of Pole clamp of GI flat 50 x 6 mm
Supply and Installation of GI wire 6 SWG for earthing
Supply and Installation of GI nuts & bolts with GI washer
Supply and Stringing of ACSR Wolf conductor ( for 11 KV & 33 KV Bus )
Supply and Installation of 33 KV Polyemric disc insulator 70 KN B&S
Supply and Installation of H/W fitting for disc insulator tension type 70 KN
Supply and Installation of Tension clamp for wolf
Supply and Installation of PG Clamp for wolf
Installation of 11 KV polymeric disc insualtor (70 KN)
Installation of Hardware fitting for disc insulator 70 KN
Installation of 11 KV polymeric pin insualtor
Supply and Construction of PCC Foundation (1:2:4) for 33 KV CT
Supply and Construction of PCC Foundation (1:2:4) for 33 KV LA
Supply and Construction of PCC Foundation (1:2:4) for 33 KV PT
Supply and Construction of RCC Foundation for 33 KV Isolator
Supply and Construction of RCC Foundation for 33 KV VCB
Supply and Installation of earthing system with MS flat 50x10mm(for earthing mat) with GI flat riser 25x6mm(for earthing conductor) & GI pipe 50mm dia of length 3000mm for electrodes) including excavation of earth welding etc.necessary
Supply and Construction of Cable trench size(950x450)mm for control cable including supply of all materials and labours as per specification and drawing.
Supply and Construction of RCC Foundation for 11 KV VCB
Supply and Construction of PCC Foundation (1:2:4) for 11 KV CT
Supply and Construction of PCC Foundation (1:2:4) for 11 KV LA
Supply and Construction of RCC Foundation for 11 KV Isolator
Supply and Construction of Transformer pad for 33/11KV 5MVA PTR
Supply and Construction of Switchyard gravelling of 0.15 m (thickness) by 40 mm size crushed stone
Supply and Construction of RCC control room building(120 sqm) , including internal electrification, water supply & sanitary works etc. complete .
Supply and Construction of Earth filling with river sand earth work in filling, levelling, compacting, grading etc. as per site condition and technical specification.
Supply and Construction of Construction of Boundary wall (212 Mtr. Approx.)
Supply and Construction of Switch yard lighting ( complete with 6 nos 40 w LED bulb with structure and acesories)
OK Enterprise
M/S Dipak Kumar Ray
M/s Shyama Construction
Nortech Power Projects Private Limited
OK Enterprise
M/S Dipak Kumar Ray
M/s Shyama Construction
Nortech Power Projects Private Limited
OK Enterprise
M/S Dipak Kumar Ray
M/s Shyama Construction
Nortech Power Projects Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .