GE Chandigarh
GE Chandigarh N Area Pin-160003
REPAIR / MAINT/ REPLACEMENT OF SECURITY , STREET LIGHT, FLOOD LIGHT, HIGH MAST, UG CABLE AND CONTROL PANEL INCLUDING REPAIR / MAINT AND IMPROVEMENT OF CERTAIN LT UG CABLE OVER HEAD LINES, LT PANEL AND ALLIED WORKS AT K AREA UNDER GE CHANDIGARH
2024_MES_673141_1
GE/CHD-42/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandigarh
Class D category b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹1 L
Yes
3 Dec 2024
7 Sept 2024
7 Oct 2024
7 Sept 2024
5 Oct 2024
23 Sept 2024
7 Sept 2024 - 14 Sept 2024
Amount
Taking down unserviceable street light fitting any from the position and replacement of accessories ie driver, surge protector and wiring circut etc and refixing at position complete with connection cable for satisfactory performance all as specified and as directed. Note :- Spares ie LED driver, surge protector and cable will be measured and paid for seperatly under respective item under this schedule here in after as "supply only".
S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
All as per item no 2 above but LED street light 45 watt complete all as specified and as directed.
All as per item no 2 above but LED street light 60 watt complete all as specified and as directed.
S&F in repair street light bracket made out of 32mm dia fancy type top mounted on 9 mtr LT tubular pole for mounting of 4 street light, 1.50 mtr long GI tubing, "medium grade" ISI marked, bent to required shape and angle as per site requirement with and including nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S&F in repair LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed..
All as per item No.06 above but of Capacity 170Watt complete all as specified and as directed. .
All as per item No.06 above but of Capacity 210 Watt complete all as specified and as directed.
Disconnection and removing the U/S street light S&F post top lantern LED 40 Watt with die cast aluminium spigot and lid cover high efficient LED and clear acrylic cover conforming to IP 65 ptrotection with clear acrylic cover and incl necessary fixing arrangement complete all as specified including taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge.
S&F in repairs LED bollard 10Watt with die cast aluminium housing with polycarbonate housing and cylinder diffuser IP 65 conforming to Halonix or equivalent in Cromption/Bajaj/C&S Complete with 10 watts LED, Driver and surge protector including making new connection with three core PVC copper flexible cable of size 23/.0076.
S&F in repairs 1100 volts grade heavy duty cable PVC insulated aluminium, with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspensionwire, two core cables cable flat or circularof size 4 Sqmm stranded conductor for sevice connection.
All as per item No. 11 above but of size 6 Sqmm.
All as per item No. 11 above but of size 10 Sqmm.
Disconnection and removing the U/S timer and S&F install digital timer switch in sheet metal encloser havig the contact rating : 16A AC1 usb key version : EG103E. 1 channel weekly cycle 56 adjustment pre recording programme two moudules with impulse and holiday function having the contactors rating all for AC 7A lead only (Coil voltage 230V 50Hz). for remote switch control a power circuit 3 No, 63 A 3 modules complete all as per manufacturer's specificationsincluding taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge.
Supply only PVC insulated copper wire FRLS of size 2.5 Sqmm (nominal area) 3 core for repair of street light wherever required at site and as directed by Engr -in-charge.
Supply only LED surge protection device having maximum discharge surge current (Imax) -10kA (8/20 µs), Nominal discharge surge current ( In)-5kA (8/20 µs) and protection level (Up) upto 5kv. up to 200 watt security light /flood light fitting complete all as specified and as directed.
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 30 Vdc & 1.3A. Driver complete all as specified and as directed.
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 42 Vdc & 1.27A. Driver complete all as specified and as directed.
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 54 Vdc & 1.50A complete all as specified and as directed.
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 48 Vdc & 2.7A complete all as specified and as directed.
Disconnection and removing the unserviceable auxilary contactors and S&F Auxilary Contactors (Existing type) 3 pole, 30 to 32 Amp with logic units.
All as per item No. 21 above but capacity 3 pole, 40Amp.
All as per item No. 21 above but capacity 3 pole, 18Amp.
Disconnecting and removing u/s MCCB and S&F MCCB 3 Pole, 63 Amps 25KA, 415Volt, 50HZ with breaking capacity 16 KA complete all as specified and as directed.
All as per item No. 24 above but of Capacity 100Amp, 16KA complete all as specified and as directed.
All as per item No. 24 above but of Capacity 125Amp, 6KA complete all as specified and as directed.
All as per item No. 24 above but of Capacity 4 Pole, 160Amp 36KA complete all as specified and as directed.
All as per item No.24 above but of Capacity 160Amp 36KA
S&F MCCB and S&F MCCB 4 Pole, 630 Amps, 415Volt, 50HZ with breaking capacity 50 KA all complete.
All as per item No. 29 above but of Capacity 400Amp 36KA.
All as per item No. 29 above but of Capacity 350Amp 36KA.
All as per item No. 29 above but of Capacity 250Amp 36KA.
All as per item No. 29 above but of Capacity 200Amp 36KA.
Disconnecting U/S Change Over and S&F Change over switch fuse type 100A, 440Volts complete all as specified and as directed.
S&F ACB and S&F ACB 4 Pole 800 Amp 50KA, 50 to 60 HZ all complete all as specified and as directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade ISI Marked along with fixing material such as GI bolt,nut and washers etc.. grade complete all as specified and as directed.
Supply and Fixing Disk type, brown, green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and as directed.
M&L for painting the LT steel tubular poles, LT Panel and cross arm channels, clamps nut & bolts with two coats of of aluminium paint over one coat of red oxide primer including prepration of surface complete all as directed.
M&L for painting 2 pole structure and cross arm channels, clamps nut & bolts with two coats of of aluminium paint over one coat of red oxide primer including prepration of surface complete all as directed.
Cutting & trimming of tree trunks / branches of grith not more than 80 mm falling on or likely to fall on LT over head electrical lines for a clearence of 6 meter on ground from the nearest counductor / pole /earth etc. & desposal of unservicable materials to distance not exc.50 mtrs & clearing of site all as directed by Engg-In-Charge.
Disconnection and removing the u/s Earthing and M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to using galvanised GI wire 4mm dia as earthing lead as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, funnel with wire mesh, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 40mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
M&L Repair/Shifting of LT Panel making electric connections including wiring by Conductor multi stranded PVC insulated welding of doors, fixing hinges, Thimble, refixing of MCCBs and brazing with bus bar etc incl complete all as specified and diercted by Engineer-in-Charge.
Supply and laying GI tubing light grade in tranches for protection of cable for 40 mm dia including taking out. old pipe complete all as diercted by Engr -in-charge.
All as per item No. 43 above but 50mm dia " light grade" ISI marked complete all as diercted by Engr -in-charge. .
All as per item No. 43 above but 80mm dia, " light grade" ISI marked.
Taking out/down old unserviceable cable any type and sizes from trenches after disconnecting from pole / bus bar box fixed on pole, complete all as specified.
Supply and lay cable XLPE Insulated screened, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 2 Core complete all as diercted by Engr -in-charge.
All as per item No 47 above but cable of size 3.5 core 25 sqmm.
All as per item No 47 above but cable of size 2 core 10 sqmm.
All as per item No 47 above but cable of size 4 core 10 sqmm.
All as per item No 47 above but cable of size 4 core 16 sqmm.
All as per item No 47 above but cable of size 3.5 core 35 sqmm.
All as per item No 47 above but cable of size 3.5 core 50 sqmm.
All as per item No 47 above but cable of size 3.5 core 95 sqmm.
All as per item No 47 above but cable of size 3.5 core 120 sqmm.
All as per item No 47 above but size 3.5 core 70 sqmm
All as per item No. 47 above but size 3.5 core, 185 Sqmm.
All as per item No. 47 above but size 3.5 core, 240 Sqmm.
All as per item No. 47 above but size 3.5 core, 400 Sqmm.
All as per item No. 47 above but size 3.5core, 500 Sqmm.
Excavation in trenches in soft/loode of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection covers. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations.
All as above item no-48 but exc 1.5m in depth but not exc 3 mtr complete all as specified.
Returning, filling in including spreading levelling, watering, and well ramming in layers not exc. 25 cm in soft/loose soil.
Removing excavated materials not exc 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying of class B bricks for under ground cable protection as directed by Engineer- in - charge
M&L for trenches less cutting of road and culvert at the span of upto 4 mtr for crossing of UG cable and GI pipe of size up 50/80 mm dia complete all as diercted by Engr -in-charge.
M & L for Outdoor type Straight through ,jointing kit, heat shrinakable for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 25 to 50 Sqmm 3.5 Core complete along with jointing material all as specified and as directed.
M&L for outdoor type heat shrinkable end joint kit for 1.1 KV grade UG cable with 3.5/4 core Aluminium conductor of size 50 to 120 Sqmm complete all as diercted by Engr -in-charge.
M & L for Outdoor type Straight through ,jointing kit, heat shrinakable for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 185 to 240 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
M & L for Outdoor type heat shrinakable End jointing kit, for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 500 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
All as per item No. 71 but of size 240 to 400 Sqmm 3.5 Core/4 Core
All as per item No. 71 but of size 185 to 240 Sqmm 3.5 Core/4 Core
M&L cement concrete 1:2:4 type B-1 (using 40 mm grades stone agregate) as in foundations, filling and mass concrete complete all as diercted by Engr -in-charge.
M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified.
Repair to existing LED type solar street light fitting with following features/specification:- 1. Luminaire:- Aluminium housing LEDs for light source optics with high effeciency driver & MPPT charge controller, Excellent heat dessipation IP 65 protection, High birghtness and high efficiency of more than 120 lm/W new age LEDs, individual peanut optical lenses for uniform light distribution system output: 2200 lm. 2. Solar Panel :- Polycrystaline solar cells. 3. battery :- Input (LifeP04) 12.8 Volt 40AH Lithium battery, weather proof, long back-up idel for cloudy conditions. 4. Pole:- Galvanised pole, Rigid and safe, corrossion free length 6 mtr. with optimum thermal management and heat sink design and microprocessor based charge controller and led driver maximizes the performance of panel & battery complete all as specified and directed.
S&F in repair LED Inverter street light 60W RTC Street light with inbuilt RTC (Real time clock) for Auto ON Auto off and must have Dimming facility from 10 to 100% of rated watage as per user defiend timeline housing made of pressure Die cast Aluminium, top maintainable and with clear heat Resistant toughened glass, should have secondary lens for better optics, should have LM 80 certified LED of CREE, with constant current rtc enabled electronic driver with 5KV SPD, IP66. Street light shall have 1.5 to 2.0 hrs battery backup at inverter load in case of power failure, Efficancy 100LPW, Pf 0.95 Cut of voltage at 300 volt, and Suitable for 50mm mounting pipe.
All as per item No 77 above but street light 60W complete all as specified and as directed.
M&L for danger notice board / plate of 1.6mm thick M.S sheet vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour 440 Volt and fixed with M.S clamps, bolts and nuts of approved size, for LT, 20 x 15cm size by removing old unserviceable.
Repair and servicing of Trolley mounted 4 Wheel extendable ladder including winch operating system assembly & replacement of following parts as per existing size and shape. Note : - (a) Steel wire rope (As per sample) -30RM. (b) Ruberised wheel heavy duty (As per sample)- 04Nos. (c) Wheel bearing 04 Nos. Note:- Repair should include cost of oiling, greasing, topping up of oil in winch/gear box including welding of broken steel members, denting, penting of the lader complete all as directed by the Engr-in-Charge.
Disconnection and removing the unserviceable broken PCC LT pole and Supply & install steel tublar pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS: 2713 (part-I) 1980 made out of MS tubing including painting of two coats of aluminium paint of approved quality over one coat of red oxide primer length 9.00 mtr long 410 SP -31 using for any description of external electric work all as specified and directed by Engr-in-charge. NOTE : (i) Earth work and PCC work will be measured and paid separately under respective item of the schedule. (ii) Material and labour for ACSR conductor, cross arms, insulators will be measured and paid separately under respective item of the schedule.
M & L for trenches less cutting of road and culvert at the span of upto 7.5 mtr for crossing of UG cable and GI pipe of size up 50/80 mm dia
Supply and fixing poly propylene composite LT phase separator, bolted type for ACSR conductor of any size, suitable for 2,3,& 5 wires, complete all as specified.
Dismantling of old unserviceable ACSR conductor and Supply and Fixing New ACSR by stratching required tension on existing LT pole conductor complete.
M&L galvanised steel wire 4 mm dia for making craddle, hexagonal / rectangular, across span complete.
M&L stay assembly with stay rod of dia meter 20 mm complete with accessories as shown in electrical plate No. 1 complete with loop type insuator, stay clamp and stay wire of size 7/2.5 mm etc . (Eart work and PCC shall be measured and paid separately)
Material and Labour for fabrication of Cross Arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and two under coat of synthetic enamel paint and incl removing rusted cross arm completeall as specified and as directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade ISI Marked along with fixing material such as GI bolt,nut and washers etc.. grade complete all as specified and as directed.
Cleaning the area of electric supply installations (Sub Station) by cutting and removing jungle sturts, roots, bushes plants small trees from roots etc incl levelling of area and deposited to n.exc 50 mtr to 100 mtr out side installations as directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 2.25 mtr below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, funnel with wire mesh, GI protetion pipe of size 40 mm dia up to test point or upto 7.5 mtr length, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 80mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
Disconnection and removing the existing orroded Galvanised iron strip from the existing location and M&L for Earth continuity conductor or main earthing lead fixed to wall/earth on buried in ground or draw in pipe or fixed to poles or any other indicated situation for loop earthing etc as required but 32 x 6 mm Iron strip
Dismantling the old ACSR conductor from the insulator / poles by removing winding from different places and stretching and refixing the conductor as required tension suitable for upto 05 wires complete as required at site incl trimming / cutting of trees upto 5 mtr either side from center of OH line( Span of 5 wire shall be measured as one unit).
Taking down old unserviceable LT current transformer and supplying, fixing, testing and commissioning of resin cast tap wound LT current transformer for rating 100/5A to 200/5A on LT panel board and connections secondary terminals to ammeter.
Disconnecting U/S Volt meter and S&F testing and commissioning of electronic volt meter 0-500 V range suitable all as specified and directed. Note :- The rate quoted shall be deemed to including the following:- (i) Control wiring for auxiliary supply 230 Volts AC if required. (ii) Calibration and testing the meter.
Disconnecting U/S Amp meter and S&F testing and commissioning of electronic Ammeter 100 to 300 Amps all as specified and directed. Note :- The rate quoted shall be deemed to including the following :- (i) Control wiring for auxiliary supply 230 Volts AC if required. (iii) Calibration and testing the meter.
M&L for replacement of indicater lamp (RYG) with LED type indicater lamp 220 volt on Feeder pilla box/LT panels.(Each Set of 3)
Preparation of surfaces of LT RCC/PCC poles and applying two coats of cement base white paint Luminious paint Strip upto 1.5 mtr height at an intervals of 30cm each yellow and black strip from the ground level and above coping for 09 mtr LT pole complete all as directed.
Surface Preparation and M&L for painting 4 pole structure and cross arm channels, clamps nut & bolts with two coats of of aluminium paint over one coat of red oxide primer complete all as directed at site.
S&F and connecting in repairs Metallized polypropylene film heavy duty cylindrical type of 2KVAr complete with suitable amps rating capacitor duty power contactor 1 No/1NC, 440Volts 3 phase 50 HZ.
All as per Item no 100 here in above but of cap 3KVAr
All as per Item no 100 here in above but of cap 5KVAr
All as per Item no 100 here in above but of cap 7.5KVAr
All as per Item no 100 here in above but of cap 12.5KVAr
Disconnection and removing the unserviceable broken PCC LT pole and Supply & install steel tublar pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS: 2713 (part-I) 1980 made out of MS tubing including painting of two coats of aluminium paint of approved quality over one coat of red oxide primer length 9.00 mtr long 410 SP -31 using for any description of external electric work all as specified and directed by Engr-in-charge. NOTE : (i) Earth work and PCC work will be measured and paid separately under respective item of the schedule. (ii) Material and labour for ACSR conductor, cross arms, insulators will be measured and paid separately under respective item of the schedule.
S & F in repars MCB, SP, 240Volt, 6 to 32 Amps, breaking capacity 10 KA, Complete all as specified
S & F in repars MCB, SPN, 240Volt, 32 Amps, breaking capacity 10 KA, Complete all as specified
S & F in repars MCB, SPN, 240Volt, 40 to 63 Amps,, breaking capacity 10 KA, Complete all as specified
S & F in repairs MCB, TPN, 415Volt, 40 to 100 Amps, Complete all as specified.
S&F in repairs MCB, TPN, 415Volt, 16 to 32 Amps, Complete all as specified.
Disconnection and removing U/S contactor and S&F Power contactor with AC coil 200Amp, 4 pole, 415 volts.
Disconnection and removing U/S contactor and S&F Power contactor with AC coil 125Amp, 4 pole, 415 volts.
Taking down existing any type of sign board and M&L for Informatory sign board of size 800mmx600mm made out of 2mm thick Stainless steel sheet fixed on Stainless steel sheet frame of ractangular shape 45mmx25mm fixed on stainless steel pipe 50mm dia 2.25mtr long vertical member-2nos ,including letter writing (100 to 150 words), logo/drawing/schematic diagram made with computerized printing of fully retro reflective with high intensity prismatic tape pasted on sheet with single side writing including vertical pipe emmebedded in 0.30X0.45mtr in PCC (1:3:6 ) type C-1 complete all as specified and directed by the Engineer-in-charge Note : (i) The cost of Excavation post hole, earth work , PCC for foundation etc shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account. (ii) The letter size of Main heading shall be minimum100mmx10mm and sub heading letter size shall be minimum 50mmx5mm. (iii) The drawing and colour of writing work shall be got approoved by Engineer in charge.
Disconnection and removing the unserviceable MCB TPN board complete and S&F MCB DB, TPN, 12 way, Including 125Amp MCCB, with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
Disconnection and removing U/S thimble and S&F Aluminium thimble 500 Sqmm
Disconnection and removing U/S thimble and S&F Aluminium thimble 400 Sqmm
Disconnection and removing U/S thimble andS &F Aluminium thimble 185 to 240 Sqmm
Disconnection and removing U/S thimble and S&F Aluminium thimble 95 to 120 Sqmm
Disconnection and removing U/S thimble and S&F Aluminium thimble 70 to 95 Sqmm
Disconnection and removing U/S thimble and S&F Aluminium thimble 25 to 50 Sqmm
Arun enterprises (BID ID -3107276)
GS Engineers (BID ID -3119202)
M/S BALWINDER SINGH (BID ID -3127107)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .