Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.4 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹16.9 L+₹1.6 L (10.2%)Rejected-Finance | L-2 | Rejected-Finance Being other than lowest. | |
| 3 | L-3₹17.0 L+₹1.7 L (10.9%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest. | |
| 4 | L-4₹18.0 L+₹2.7 L (17.6%)Rejected-Finance H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-4 | Rejected-Finance Being other than lowest. | |
| 5 | L-5₹19.6 L+₹4.3 L (27.8%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L-5 | Rejected-Finance Being other than lowest. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
5 Aug 2020, 6:00 pmClosed
GEAFADMAREAAGRA
GEAFADMAREAAGRA
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL FANS INCLUDING REPLACEMENT OF ELECTRIC METER IN 4 AREA AND NEW MAP FHASE II AREA UNDER AGE E M OF GE AF ADM AREA AGRA
2020_MES_361881_1
8000-1814/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GEAFADMAREAAGRA
Class E Cat b ( i ) and for un enlisted firms docs as per NIT
8 documents required · 8 mandatory
₹500
GEAFADMAREAAGRA
₹40,000
Yes
9 Sept 2020
17 Jul 2020
7 Aug 2020
17 Jul 2020
5 Aug 2020
24 Jul 2020
Amount
Taking down/ collect the unserviceable/ burnt ceiling fan/ exhaust fan/ pedestal fan/ wall mounted fan/ cabin fan any sweep from any height of building/ site for repair/ rewinding/ overhauling and re-fixing the same after repair/ overhauling and testing complete at same place or other place as directed by the engineer-in-charge. (i) Fixing of repaired fan in any location of camp area shall be contractors responsibility at his own arrangement of transport and T& P. (ii) Old burnt wire will be contractors property and necessary credit shall be recovered as per sch of credit) Note – Repair/ rewinding/ overhauling shall be measured & paid separately under respective items of BOQ.
M&L for strip opening of ceiling fan 1200 mm sweep for overhauling including cleaning, greasing, oiling and minor repair work, including checking nuts and bolts, clamps etc complete and reassembling the same after testing on full load with blade complete all as specified and directed. Note : Capacitor, bearings, regulators, rubber reel and other connected items shall be measured and paid separately under respective items as "Supply Only").
Description all as per item No 2.00 here-in-before but ceiling fan 1400 mm sweep.
Description all as per item No 2.00 here-in-before but for exhaust fan of size up to 300 mm sweep.
Description all as per item No 2.00 here-in-before but for exhaust fan of size above 300 mm & up to 450 mm sweep.
Description all as per item No 2.00 here-in-before but for wall mounted fan/ cabin fan of size up to 450 mm sweep.
M&L for rewinding of ceiling fan motor 1200 mm sweep any make with super enameled copper winding wire ISI marked of gauge as per existing including cutting and getting out old U/S winding, sleeve work, varnishing , threading incl. making connections with three core copper flexible wire of suitable size and reassembling the same and two coats of synthetic enamel paint with spray painting including cleaning the fan with cleaning materials or tinner after testing at full load with blades to the entire satisfaction of Engineer-in-charge complete all as specified and directed.
Description all as per item No 7.00 here-in-before but for ceiling fan of 1400 mm sweep.
Description all as per item No 7.00 here-in-before but exhaust fan of size up to 450 mm sweep, 230 V, AC.
Description all as per item No 7.00 here-in-before but for wall mounted/ cabin fan of size up to 450 mm sweep.
M&L for machining the shaft of ceiling fan to suit the gun metal bushes off sizes complete all as specified and directed.
Supply only ball bearing of ceiling fan of size 6201/ 6202 complete all as specified and directed. Make :- NBC/ SKF
Supply only ball bearing of exhaust fan of size 6203/ 6204 complete all as specified and directed. Make :- NBC/ SKF
Supply only gun metal bushes for fans of suitable sizes complete all as specified and directed.
Supply only capacitor 2.5 MFD, 230V AC complete all as specified and directed. Make :- Asian/ Usha/ Bajaj/ Crompton.
Supply only of capacitor 3.15 MFD, 230V, ACcomplete all as specified and directed. Make : Usha/ Bajaj/ Asian/ Crompton.
Supply only capacitor 4 MFD, 230V, AC complete all as specified and directed. Make : Usha/ Bajaj/ Asian/ Crompton.
Supply only rubber reel of suitable sizes for ceiling fan 1200 / 1400 mm sweep complete all as specified and directed.
Supply only flexible wire 23/ 0.0076 size three core, 1100 V, twisted, PVC insulated, copper conductor multistrand for connection complete all as specified and directed.
Supply only MS nut, bolt 8 mm dia of suitable size for hanging of the ceiling fans complete all as specified and directed.
M&L for MS clamp for hanging the ceiling fans of suitable size complete all as specified and directed.
M&L for down rod MS 15 mm dia, heavy duty of size 300 mm long including making hole for hanging ceiling fan complete all as specified and directed.
M&L for down rod MS 15 mm dia, heavy duty of size 450 mm long including making hole for hanging ceiling fan complete all as specified and directed.
M&L for canopy of suitable size for ceiling fan 1200/ 1400 mm sweep (white colour) complete all as specified and directed.
S&F in repair ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed. Make : Havells Reo/ Cona/ SSK.
M&L for replacement of exisitng U/S meter box with polystrene polycarbonate hinged door, with transparent lid, meter box of size 168 mm x 253 mm x 115 mm in accordance with IEC 60670- 24, shall be IP 65 protection with IEC 60529, corrosion proof suitable for single phase energy meter, internally embedded polyurethane gasket for lid, metric size knock out for cable entry from top and bottom. Meter box shall be suitable to accomodate the meter of any make complete all as specified and directed. Make:- Hensal KG 9002 / Seimens/ Rittal. Note :- (i) Taking down existing meter and refixing in new meter box shall be deemed in quoted rate. (ii) Min. 4 sqmm single core FRLS PVC insulated multi-stranded copper conductor cable shall be used for making connections from meter to DB incl. providing pin/ bottle type copper thimbles shall be part of Job. (iii) All wires shall be drawn in PVC flexible conduit of suitbale dia.
S&F aluminium blades of suitable size for ceiling fan of size 1200 mm sweep as per sample complete including taking down of old unserviceable blade complete all as specified and directed. Make : Usha/ Bajaj/ Crompton.
Description all as per item No 27.00 here-in-before but for size 1400 mm sweep.
Description all as per item No 27.00 here-in-before but for exhaust fan of size up to 300mm sweep. Make : Usha/ Bajaj/ Crompton Greaves.
Description all as per item No 27.00 here-in-before but for exhaust fan of size up to 450mm sweep. Make : Usha/ Bajaj/ Crompton Greaves.
S&F in replacement fibre blades of suitable size for wall mounted fan of up to 450 mm sweep complete all as specified and directed.
S&F 15 mm bore GI pipe, ‘medium grade’ for making down rod of required size for hanging ceiling fan including MS clamps of suitable size and shape compete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . Make:- Legrand / Schenieder/ Seimens
S&F in replacement MCB single pole 240 volts, 'B' curv of rating from 6 to 40 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables. Make:- Legrand / Schenieder/ Seimens.
S&F in replacement MCB SPN 240 volts, 'B' curv of rating from 6 to 40 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables. Make:- Legrand / Schenieder/ Seimens
M&L for replacement of existing U/S submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification. Make of copper wire: Polycab / Grandlay / Finolex.
M&L for fixing of GI tubing 40 mm bore 'light grade' with required fittings at site for provision of hanging of ceiling fans including making hole and making good the disturbed surface to match with existing specifications complete all as spd and directed. Make:- Jindal/ Ravindra/ Surya.
S&F in replacement of existing U/S geyser element 1.5 KW Triangle/ Round (as per approved sample) of ISI marked complete all as specified and directed. Make: Dass pass/ DITZ/ Theeta.
S&F in replacement of existing U/S geyser element 2 KW Triangle/ Round (as per approved sample) of ISI marked complete all as specified and directed. Make: Dass pass/ DITZ/ Theeta.
S&F in replacement of existing U/S geyser thermostat adjustable type between 30 0C to 85 0C of ISI marked complete all as specified and directed.
M&L for replacement of existing U/S louwers/ shutters suitable for 300 mm sweep exhaust fan complete all as specified and directed.
M&L for replacement of existing U/S louvers/ shutters suitable for 450 mm sweep exhaust fan complete all as specified and directed.
S&F in replacement static energy meter electronic tamper proof energy meter with backlite (LCD with multi features digital type) with optical communication port for down loading the data and two push buttons for manual depation to read the data, single phase two wire direct operated 240V, 50 Hz AC supply, class of accuracy 1.0 operating voltage 140 V to 300 V, AC range basic current 10A maximum 60 A (10-60A) conforming to IS 13779/CBIP 88 ISI marked with Engineering plastic transparent pilfer proof meter box to house the single phase and class of protection shall not be less than IP 51, dust & vermin proof, shock proof of suitable size to house meter freely complete all as specified and directed. Make - L&T/ Indo Asian/ Havells.
jmd engineers
AGRA AND COMPANY
H.S.Kochhar n Sons
MUKTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .