Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 01 SORANA NAKUR SAHARANPUR UTTAR PRADESH 247232 | SAHARANPUR | UTTAR PRADESH | 247232 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.6 L+₹1.6 L (4.58%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹36.0 L+₹2.0 L (5.77%)Rejected-Finance 2 2407 GILL COLONY NARAINPURI SAHARANPUR UP | SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹37.4 L+₹3.4 L (9.87%)Rejected-Finance PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L4₹41.5 L+₹7.4 L (21.8%)Rejected-Finance | L4 | Rejected-Finance Being 5th lowest |
Tender Value
₹43.2 L
EMD Value
₹86,480
Closing Date
20 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
PROVN OF LAND SCAPING AND ARBORICULTURE NEAR BLDG No. P-88 AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2024_MES_647687_1
8123/SAR-76/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE(AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) SARSAWA
₹86,480
Yes
20 Jun 2024
23 Mar 2024
27 Apr 2024
23 Mar 2024
20 Apr 2024
6 Apr 2024
23 Mar 2024 - 6 Apr 2024
Amount
M&L Steel work in tubular trusses including, plates , nut/bolts, fastners, special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 Complete all as specified
M & L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L Pre- painted galvatume aluminum zinc coating GI based Semi-corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge.
M&L for with or without reinforcement Cutting opening in cement concrete walls (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc.
Providing, cement concrete type B1 (1:2:4) 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L for rendering 15mm thick in CM 1:4 on stone wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound ( water proofing compound shall be separately paid) all as specified.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L for false ceiling made out of E-board classic of size 600 x 600 x 4 mm thick, GI frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with GI wire 5mm dia and up to 2 Mtrs long complete including plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/c and applying two coats of Oil Bound distemper to the ceiling board complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplush soil to a distance n exc 50m and making good surface complete all as directed by Engineer-in-charge and all as specified.
M&L for PCC Type C2 1:3:6 (40 mm graded aggregate) Cement concrete in foundations, filling and mass-concrete complete all as specified & directed by Engr-in-Charge.
M&L for 100 mm thick PCC 1:4:8 type D -2 using 40 mm graded aggregate as in sub base of path/hardstanding complete all as specified & directed by Engr-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed by Engr-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Demolition of cement concrete (un-renforced) in ground floor and paving. N exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as directed by Engineer-in-charge and all as specified.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate), as in sub base all as directed by Engineer-in-charge.
M&L Vitrified Ceramic tiles 10mm thick double charged (square/rectangular) polished, area of each tiles exceeding 0.36 sqm, but not 0.42 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 15mm thick cement screeding in CM 1:6 Complete all as specified and directed by Engr-in-Charge.
M&L Vitrified Ceramic tiles 10mm thick double charged (square/rectangular) polished, area of each tiles exceeding 0.36 sqm, but not 0.42 sqm, in vertical surfaces as skirting and dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 10mm thick rendering in CM 1:4 Complete all as specified and directed by Engr-in-Charge.
M&L for point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with including modular type PVC rectangular block of suitable size and plate and frame of modular type including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :- One light / fan point controlled by one way switch
All as per above item No-20 here in before but One 5 Amp socket outlet on independent board.
All as per above item No-20 here in before but One 5 Amp socket outlet on same board.
All as per above item No-20 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S & F in of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including concealed PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F of ceiling rose surface polycarbonate 63 x50mm three terminals complete all as specified and as directed.
S&F socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
S&F switch 6 amps modular type one one way complete all as directed.
S&F switch 16 amps modular type one one way complete all as directed.
S&F socket outlet 6A-2/3 pin combined 2 module modular type complete all as specified and directed.
Supply and fixing LED type flood light 35 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
S&F sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.
S&F MCB SP 5 to 40 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F MCB DP 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
DHIMAN ENGINEERS & BUILDERS
RAMAPATI ENGINEERING SERVICES
RADHA ENTERPRISES
M/s RAM RATAN AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .