| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹16.3 L+₹54,849 (3.48%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹18.4 L+₹2.7 L (17.2%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹21.1 L+₹5.3 L (33.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | Rejected-Technical | - | Rejected-Technical Not capable for handling more load as per WLR |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Jan 2020, 6:00 pmClosed
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2019_MES_303306_1
GE (AF) NAL/T-40/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) Nal
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹40,000
Yes
GE (AF) Nal, Bikaner
8 Feb 2020
3 Dec 2019
9 Jan 2020
3 Dec 2019
7 Jan 2020
18 Dec 2019
6 Dec 2019 - 9 Dec 2019
11 Dec 2019
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour sand cushioning (Tibba Sand) for protection of underground cable, consolidated and compacted with clean dry sand complete all as specified and as directed.
Supply and laying Precast unreinforced Concrete cable covers Class HV, type 1 flat of size 300mm x 180mm x 40 mm for HT cable all as specefied
Taking out HT un-serviceable / faulty cable of Cross sectional area 95 sq mm, 3 core from trench / pole / cable duct carefully incl bricks, pipe and stacking properly for disposing off from site or for relaying in same place complete all as directed Note : (i) Excavation and earth work shall be measured and paid separately. (ii) Unit rate of this item include the cost of taking out brick protection/ tiles and GI Pipe etc as applicable. (iii) Old serviceable cable shall be stored properly for relaying / handing over to contractor for disposal off from site.
All as per description of serial item No. 6.00 here in before but cable of cross sectional area 120 sqmm, 3 core
All as per description of serial item No. 6.00 here in before but cable of cross sectional area 185 sqmm, 3 core
Laying only including testing of HT serviceable PVC / XLPE insulated 11000 Volts grade aluminium conductor cable Cross sectional area 95 sq mm, 3 core in trench or fixed to wall /passing through pipe / pole complete all as specified and directed. Note : (i) Old serviceable cable retrived under Item No. 6.00 here-in-before shall be used in the work. (ii) Brick protection, concrete cable cover, sand cushioning shall be measured and paid for separately.
All as per description of serial item No. 9.00 here in before but cable of cross sectional area 120 sqmm, 3 core.
All as per description of serial item No. 9.00 here in before but cable of cross sectional area 185 sqmm, 3 core.
Supply, laying and testing XLPE insulated, armoured 11000 Volts grade aluminium conductor cable, Cross sectional area 95 sq mm, 3 core, as per IS-7098 (Part-II), in trenches or fixed to wall /passing through pipe / pole, as directed for the following cross sections. Note : (i) Excavation and earth work shall be measured and paid for separately. (ii) Concrete cover protectioin and sand cushining shall be measured and paid for separately. (iii) Pipe including clamps shall also be measured and paid for separately.
All as per description of serial item No. 12.00 here in before but cable of cross sectional area 120 sqmm, 3 core
M&L straight through joint HT 11000 volts grade heat shrinkable of cable Cross sectional area 70 Sqmm, 3 core complete all as specified and directed. Note : 1. Excavation & earthwork shall be measured and paid for separately
All as per description of serial item No. 14.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 14.00 here in before but for cable of cross sectional area 120 sqmm, 3 core
S&F End termination joint (Out door type) heat shrinkable HT 11000 volts grade of cable Cross sectional area 70 Sqmm, 3 core complete all as specified and directed.
All as per description of serial item No. 17.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 17.00 here in before but for cable of cross sectional area 120 sqmm, 3 core
M&L End termination joint (Indoor type) heat shrinkable HT 11000 volts grade of cable Cross sectional area 70 Sqmm, 3 core complete all as specified and directed.
All as per description of serial item No. 20.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
All as per description of serial item No. 20.00 here in before but for cable of cross sectional area 120 sqmm, 3 core
Supply and fixing GI tubing light grade 80 mm bore for cable protection complete all as specified and directed. Note:- Cost of taking out of pipe included in unit rate for taking out cable here-in-before.
All as per description of serial item No. 23.00 here in before but 100mm bore pipe
Tracing out fault in 11KV underground cable any size with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. Note: (i). Joint kit shall be measured and paid separately. (ii) Earth work shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width given in SSR for each size of cable. (iii) All other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted. (iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account. (v) Cable required, if any shall be measured and paid for separately. (vi) Fault & location thereof shall be traced within 12 hours of intimation by the Engineer-in-Charge and shall be rectified within given time frame
M&L servicing of 33 KV Isolator including, greasing repairing U fingers and knives as suitable, fixing connecting leads properly with suitable size conductor and checking and repairing the operation complete all as specified. Note : (i) Cost of grease, lubricating oil shall be deemed included in the unit quoted rate. (ii) Site of servicing shall be given as and when felt by GE/ Engineer-in-Charge and nothing extra shall be admissible on account of any misunderstanding. (iii) Servicing shall be carried out by the contractor within time frame allowed by the GE/ Engineer-in-Charge. Therefore, contractor shall provide the sufficient manpower/ electricians including T&P well in advance so that interruptions of electricity can be minimized.
M&L servicing of Air Break Switch (GOD) 11 KV (200/400 Amp) including, greasing repairing/replacement of U fingers and knives blade as suitable, fixing connecting leads properly with suitable size conductor and checking and repairing the operation complete all as specified. Note : (i) Cost of grease, lubricating oil shall be deemed included in the unit quoted rate. (ii) Site of servicing shall be given as and when felt by GE/ Engineer-in-Charge and nothing extra shall be admissible on account of any misunderstanding. (iii) Servicing shall be carried out by the contractor within time frame allowed by the GE/ Engineer-in-Charge. Therefore, contractor shall provide the sufficient manpower/ electricians including T&P well in advance so that interruptions of electricity can be minimized.
S&F as in repairs out door, TP, Gang Operating Device, in single bank, tilting type suitable for vertical / horizontal mounting consisting of hot dipped electro plated galvanised channel iron base having 9 Nos insulators 11 KV, copper aloy tinned contacts, copper or chromium plated MS arcing chains capable of making and breaking the magnetising current complete with horizontal bar, GI pipe as down operating rod coupled with handle for operation with locking arrangement with working voltage of 11000 Volts of 200 Amps rating and testing on full load complete all as specified. Note : Contractor shall produce original purchase vouchers and test certificate duly attested by the manufacturer.
M&L Disconnecting, opening of 33KV, 3 Pole, 200/ 400 Amps, outdoor type Porcelain Clad Vaccum Circuit Breaker of Make: Crompton Greaves / GEC, type : 36PV25A (used for protection of 33/11 KV ,3.15 MVA transformer) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing and caliberation, greasing, oiling of parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing and commisioning complete all as specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under relevent item of sch 'A' as supply only but cost of fixing of the parts replaced/repaired shall be deemed to be included in this item. (ii) Servicing shall be got carried out by the authorised rep of VCB manufacturer. The service engineer will submit a service report including calibration for each VCB and unit rate of this item includes this element. (iii) Any item not mentioned in the description of item above but required for successful operation of the panel shall be provided by the contractor and the cost there of shall be deemed to be included unit rate quoted. (iv) Complete repair/ services as applicable shall be carried out at work site only. (v) Complete job shall be completed within reasonable time as allowed by the GE/Engineer-in-Charge, accordingly contractor shall provide all arrangements including T&P and equipments/ parts well in time for timely completion of work. Tenderer are hereby advised to keep this factor while quoting their rates.
Supply only following parts suitable for 33KV VCB of Make : Crompton / GEC dismantled / fixed under Sch 'A' item No: 29.00 here-in-before complete all as specified and directed:-
Vacuum Interrupter suitable for 33 KV VCB Panel CT 200/400 Amps
Tripping Coil assembly 24 Volts DC suitable for 33 KV VCB Panel
Close Coil assembly 24 Volts DC suitable for 33 KV VCB Panel
TNC switch for 33 KV VCB Panel
Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
HRC fuse blade type 2 Amps, 24 Volt,
M&L Servicing of 33 KV Potential Transformer, cleaning of core, checking of all connections replacement of oil and testing of all connections complete all as specified and directed. Note:- Oil shall be measured and paid for separately under respective item of this Schedule.
M&L Servicing of 33 KV Current Transformer, cleaning of core, replacement of oil (40 Ltr), testing of all connection complete all as specified and directed. Note:- Oil shall be measured and paid seperatly under respective item as 'Supply only'.
Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not less than 65 KV for topping up the Power/distribution transformer HT 33 KV / 11 KV. NOTE:- Transformer oil shall be brought by the contractor in sealed standard packing in barrell of 210 ltrs capacity. Contractor shall produce the original purchase vouchers and test certificate from the manufacturer.
M&L filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength / insulation value upto 65 KV/40KV (RMS) at standard gap of electrodes 2.5 mm for one minute in various capacity of transformers 33/11KV and 11/0.433KV including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test complete all as specified and directed.
Supply and fixing as in repairs PG clamp die cast aluminium of suitable size and for fixing clampling ACSR conductor connections for PT's CTs isolators all as specified
Supply, stringing and fixing as in repairs ACSR conductor of any type/size on existing poles including fixing to insulators with binding wire or aluminium taps complete all as specified .
Disconnecting, opening of indoor type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom) of any description and any make of rating 11 KV 400/630/800 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in the item rate. (ii) Servicing shall be got carried out by the authorised rep of the VCB manufacturer and the service engineer will submit a service report and calibration certificate for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
Supply only following parts suitable for 11KV VCB, 400/630 Amps capacity of Make : Crompton/Megawin/Yamuna Denson/ABB Ltd, Alstom) dismantled / fixed under Sch 'A' item No: 37 here-in-before complete all as specified and directed.
Vacuum Interrupter type WL-33379 suitable for 11 KV, VCB circuit breaker
Isolating contact assembly 400/630/800 Amps suitable for 11 KV/400/630/800 Amp VCB Panel
Tripping Coil assembly 24/30 Volts DC suitable for 11 KV VCB Panel
Close Coil assembly 24/30 Volts DC suitable for 11 KV VCB Panel
TNC switch for 11 KV VCB Panel
Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
M&L testing and calibration of 11KV VCBs (Make : Crompton / Megawin / Dension / ABB Ltd, Alstom) indoor type alongwith control panel and control wiring, protection system and relays system (relay to tripping coil auxiliary switch male and female housing cut outs etc) , checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing (IR value, Ratio test, Polarity test) and connection verification of 11 KV Current transformer (Set of three) by PRIMARY INJECTION KIT and Testing and calibration of relay (set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all as specefied and directed.
M&L for servicing testing and calibration of 11KV SF6 circuit breaker/ 01 Way 400/630 Amp (Make : CG Lucy/ Crompton/Megawin/ Dension/ABB Ltd, Alstom) indoor type alongwith control panel and control wiring, protection system and relays system (relay to tripping coil auxiliary switch male and female housing cut outs etc) , checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing (IR value, Ratio test, Polarity test) and connection verification of 11 KV Current transformer( Set of three) by PRIMARY INJECTION KIT and Testing and calibration of relay (set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all as specefied and directed.
All as per description of serial item No. 40.00 here in before but 2 way
All as per description of serial item No. 40.00 here in before but 3 way RMU having 2 Nos I/C and one No out going
M&L repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity up to 250 KVA, by dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oil from the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, explosion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oil will be measured & paid for seperately (ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation.
All as per description of serial item No. 43.00 here in before but capacity of transformer 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed.
Supply only brass terminal rod with nuts, bolts washers & bushings suitable for HT and LT side of the transformer of any make and capacity upto 100KVA complete.
All as per description of serial item No. 45.00 here in before but capacity of transformer exceeding 100 KVA but not exceeding 250 KVA.
All as per description of serial item No. 46.00 here in before but capacity of transformer exceeding 250 KVA but not exceeding 630 KVA.
Supply only super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed.
S&F as in repairs of Maintenance free sealed battery 7 AH complete all as specified and directed.
M&L as in repairs of operating rod made out of heavy duty 25mm G.I tube and connecting the same with operating handle and GOD complete all as specified and directed.
S&F as in repairs of post type porcelain insulator vitreous, white brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height,150 mm dia for 11KV grade complete all as specified and directed.
Supply and fix as in repairs HT cable route marker / HT cable joint marker made of Jodhpur stone 250mm x 150mm size, 900mm long, with top of oval shaped, two sides engraved with letters 'HT cable', letters painted with approved paint, embedded in ground including necessary excavation and earthwork complete all as specified and directed.
S&F as in repairs drop out fuse double stack channel type suitable for 11 KV on and including 06 insulators (set of three) complete all as specified and directed
M/s Rohit Construction Co.
SRI SAI CONSTRUCTION COMPANY
GURDEEP SINGH AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .