Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAdmitted-Finance INDIA | L1 | Admitted-Finance | |
| 2 | L2₹21.2 L+₹4.0 L (23.5%)Admitted-Finance 1301 13 BVR EK OPP INDER RESIDENCY HOTEL NR WESTOND HOTEL ELLISBRIDGE AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | L2 | Admitted-Finance | |
| 3 | L3₹22.5 L+₹5.4 L (31.3%)Admitted-Finance A 8 MOHAN COOPERATIVE INDUSTRIAL ESTATE MATHURA ROAD NEW DELHI 110044 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110044 | L3 | Admitted-Finance | |
| 4 | L4₹22.9 L+₹5.8 L (33.9%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹37.0 L+₹19.8 L (115.7%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | EIE INSTRUMENTS PVT. LTD L2 | Mass International L5 | Aimco Solutions LLP L1 | AIMIL LTD L3 | BALAJI ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00ITEMS (BITUMEN TESTING MACHINES) | ||||||||
| 1.01 | Cannon Manning cum Cannon Fenske Viscometer bath with Vaccum Pump with Viscometer (Tube size 11,12, 6)
Digital Vacuum Regulator System
The equipment should consists of Digital Vacuum Regulator system consisting of Vacuum Pump for maintaining the vacuum to desired level , 4 Nos. manifold bleed values, moisture trap, vacuum regulator, Start/Stop button, 3- Pin power connector, digital display, all interconnecting tubings/piping and accessories as needed to complete the vacuum system.
Digital vacuum regulator pressure: up to 650 mmHg
Provision: For 4 test.
Pressure Cell range : -1 to 1 bar G (Pin Connection),
Vacuum Pump (fitted Inside) :
Vacuum Pump Specification:-
Power : 220V 50Hz , Max Power (W) : 60 , Max Vacuum : -650 mm/Hg , Max Pressure : --600 mm Hg , Rotation : 1450 RPM , Capacitance : 2 f 450 V , Horse Power : 1/8 HP , Port. Thread : 5/16" , Noise Level : 50 dB
Double layer constant temperature bath :
The inner bath adopts ɸ 300 mm x 300 mm hard glass material. The outer shell adopts ɸ 360 mm x 285 mm organic glass material. The interlayer is a layer for heat preservation. Two holes are set on the bath cover. One is for thermometer and the other is for sensor. Four installation holes for capillary viscometers are set on the bath cover. It can do two groups of parallel tests. The accuracy of the viscometer bath is ± 0.1 ˚C over the entire length of the viscometer or from
viscometer to viscometer in the various bath positions. Capacity 23L.
Main technical specification and parameters:
Heating Power: 1700 W , Temperature range: Ambient to 135.0 ˚C , Temperature control accuracy: ± 0.1 ˚C , The range of timer: 0-9999.9s , Bath capacity: 23L , Stirring motor: Power 6W, speed 1200 RPM
Temperature sensor: RTD, Pt100 , Maximum power consumption: 1800 W
Overall dimension: 530x400x670mm ( bath should be included)
(with Two years Warranty) | 1 | Nos | 4,05,920 ₹4,05,920 Lowest | 7,80,000 ₹7,80,000 | 4,35,167 ₹4,35,167 | 5,63,450 ₹5,63,450 | 7,53,200 ₹7,53,200 |
| 1.02 | Cleveland Flash (Open) & Fire Point Apparatus
Instrument will be used for determination of the flash & fire points of petroleum products except oils and products having an open cup flash below 175o F.
It should have a Cleveland flash-cup in brass with an insulated handle, a metal heating plate with a circular opening covered by asbestos board, an electric heater with energy regulator, and a gas test jet assembly.
Complete with Thermometer IP28 C Range of -6°C to +110°C
(with Two years Warranty) | 1 | Nos | 12,390 ₹12,390 Lowest | 26,500 ₹26,500 | 14,160 ₹14,160 | 20,282 ₹20,282 | 16,520 ₹16,520 |
| 1.03 | Universal Penetrometer
The instrument will be used for determining the penetration value of bitumen.
The instrument should have the automatic timer to control duration of penetration. Exactly 5 seconds to a timing head (built in timer). The timer head should allow the plunger rod to fall freely for 5 seconds and clamps. It should have leveling screws.
Complete with supply of Penetration cone, penetration needle, dish made of copper, sample container (set of 2) made of aluminum.
(with Two years Warranty) | 1 | Nos | 28,910 ₹28,910 | 55,000 ₹55,000 | 29,500 ₹29,500 | 41,537 ₹41,537 | 16,284 ₹16,284 Lowest |
| 1.04 | Rotational Viscometer
Test to perform ASTM D4402 & BIS 73 high temperature testing of asphalt binders. It should have thermal chamber electrically heated with auto tuned PID controller for precise regulation of asphalt temperature upt 300C. Single measurement can be performed via instrument from panel and displayed on the builtin keyboard or optional printer
Complete with C25 titanium bob stainless steel cup.
Rotational speed: 0-1000 rpm
Shear rate 1/s, s-1 4-1 , 200
Torque Range 0-10mNm
Shear stress Pa 8-1, 500
Viscosity Pas 0.006-350
The heater temp range Amb. To 300°C
Measurement system DIN 53019 C25
Serial interface RS232/USB
Less Power consumption 4W
(with Two years Warranty) | 1 | Nos | 10,03,000 ₹10,03,000 | 11,40,000 ₹11,40,000 | 4,11,567 ₹4,11,567 Lowest | 5,16,250 ₹5,16,250 | 7,39,200 ₹7,39,200 |
| 1.05 | DIGI Modified Marshall Apparatus, for 4"/6" dia sample
Marshall apparatus will be used to measure the resistance of cylindrical bituminous mix specimens to plastic flow under loading on the lateral surface. This test method is used for bituminous mix design.
The test measures the maximum load supported by the test specimen at a loading rate of 50.8 mm/minute. Load is applied to the specimen till failure, and the maximum load is designated as stability.
100kN Single Speed machine. Sample dia 4”/6”. Complete with 3 set of compaction mould.
(with Two years Warranty) | 1 | Nos | 2,30,100 ₹2,30,100 | 5,40,000 ₹5,40,000 | 2,93,567 ₹2,93,567 | 3,78,338 ₹3,78,338 | 1,86,440 ₹1,86,440 Lowest |
| 1.06 | Pavement Core Drilling Machine
The Pavement Core drilling machine should have following
• Petrol engine powered for road building drill for the purpose of drilling test cores from or holes in roads, airport runways, bridges.
• The machine should be complete with 6HP petrol engine
• Low vibration.
• Two vertical support columns to carry the drill head/engine.
• Metal (rigid) base plate, leveling facility.
• Suitable for vertically coring.
• Suitable for depth of core upto 400mm
• Variable drilling speed from 900 to 1200rpm
• Bit diameter 150mm
• Drill wrenches.
• Water Tap.
• Diamond Core Bits, 100mm dia x 200.
(with Two years Warranty) | 1 | Nos | 2,06,500 ₹2,06,500 | 4,50,000 ₹4,50,000 | 2,00,600 ₹2,00,600 | 2,77,257 ₹2,77,257 | 1,98,240 ₹1,98,240 Lowest |
| 1.07 | Automatic compactor:
The equipment should be a Rugged construction to withstand hard work, Fully automatic and easy to operate, uniform compaction, automatic blow counter and automatically stops machine on completion.
The drive mechanism should be capable of lifting the weight of 4.5 Kg and 10.2 kg and drops it through a height of 457mm.
It should be capable of accommodating both 4” moulds.
Suitable for operation on 230 V, 50Hz, Single phase, AC Supply.
(with Two years Warranty) | 1 | Nos | 1,03,250 ₹1,03,250 Lowest | 2,80,000 ₹2,80,000 | 1,35,700 ₹1,35,700 | 1,77,000 ₹1,77,000 | 1,74,640 ₹1,74,640 |
| 1.08 | Semi Automatic Ring and Ball Apparatus
It should have magnetic stirrer with heating facility and digital display of temperature, and integral PID controlled for heating adjustment.
(with Two years Warranty) | 1 | Nos | 28,910 ₹28,910 Lowest | 65,000 ₹65,000 | 33,040 ₹33,040 | 48,426 ₹48,426 | 80,240 ₹80,240 |
| 1.09 | Centrifuge Extractor
Compact with inbuilt dimmerstat for speed veration from 0 rpm to 3600 rpm.
Capacity : 1500g
(with Two years Warranty) | 1 | Nos | 33,630 ₹33,630 Lowest | 95,000 ₹95,000 | 44,840 ₹44,840 | 60,947 ₹60,947 | 37,760 ₹37,760 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
18 Feb 2021, 3:00 pmClosed
General Manager (MKT), SICOP, Gangyal Jammu
General Manager (MKT), SICOP, Gangyal Jammu
Suppliers for Supply of Material Testing Equipments at SICOP Testing Centre Digiana, Jammu.
2021_SICOP_115629_1
SICOP 2721 Dated 05.02.2021
Open Tender
Miscellaneous Goods
Item Rate
30 days
SICOP Testing Centre Digiana
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
0116020100000058, IFSC code- JAKA0GNGYAL
₹1 L
Yes
23 Feb 2021
5 Feb 2021
19 Feb 2021
5 Feb 2021
18 Feb 2021
5 Feb 2021
Amount
ITEMS (BITUMEN TESTING MACHINES)
Cannon Manning cum Cannon Fenske Viscometer bath with Vaccum Pump with Viscometer (Tube size 11,12, 6) Digital Vacuum Regulator System The equipment should consists of Digital Vacuum Regulator system consisting of Vacuum Pump for maintaining the vacuum to desired level , 4 Nos. manifold bleed values, moisture trap, vacuum regulator, Start/Stop button, 3- Pin power connector, digital display, all interconnecting tubings/piping and accessories as needed to complete the vacuum system. Digital vacuum regulator pressure: up to 650 mmHg Provision: For 4 test. Pressure Cell range : -1 to 1 bar G (Pin Connection), Vacuum Pump (fitted Inside) : Vacuum Pump Specification:- Power : 220V 50Hz , Max Power (W) : 60 , Max Vacuum : -650 mm/Hg , Max Pressure : --600 mm Hg , Rotation : 1450 RPM , Capacitance : 2 f 450 V , Horse Power : 1/8 HP , Port. Thread : 5/16" , Noise Level : 50 dB Double layer constant temperature bath : The inner bath adopts ɸ 300 mm x 300 mm hard glass material. The outer shell adopts ɸ 360 mm x 285 mm organic glass material. The interlayer is a layer for heat preservation. Two holes are set on the bath cover. One is for thermometer and the other is for sensor. Four installation holes for capillary viscometers are set on the bath cover. It can do two groups of parallel tests. The accuracy of the viscometer bath is ± 0.1 ˚C over the entire length of the viscometer or from viscometer to viscometer in the various bath positions. Capacity 23L. Main technical specification and parameters: Heating Power: 1700 W , Temperature range: Ambient to 135.0 ˚C , Temperature control accuracy: ± 0.1 ˚C , The range of timer: 0-9999.9s , Bath capacity: 23L , Stirring motor: Power 6W, speed 1200 RPM Temperature sensor: RTD, Pt100 , Maximum power consumption: 1800 W Overall dimension: 530x400x670mm ( bath should be included) (with Two years Warranty)
Cleveland Flash (Open) & Fire Point Apparatus Instrument will be used for determination of the flash & fire points of petroleum products except oils and products having an open cup flash below 175o F. It should have a Cleveland flash-cup in brass with an insulated handle, a metal heating plate with a circular opening covered by asbestos board, an electric heater with energy regulator, and a gas test jet assembly. Complete with Thermometer IP28 C Range of -6°C to +110°C (with Two years Warranty)
Universal Penetrometer The instrument will be used for determining the penetration value of bitumen. The instrument should have the automatic timer to control duration of penetration. Exactly 5 seconds to a timing head (built in timer). The timer head should allow the plunger rod to fall freely for 5 seconds and clamps. It should have leveling screws. Complete with supply of Penetration cone, penetration needle, dish made of copper, sample container (set of 2) made of aluminum. (with Two years Warranty)
Rotational Viscometer Test to perform ASTM D4402 & BIS 73 high temperature testing of asphalt binders. It should have thermal chamber electrically heated with auto tuned PID controller for precise regulation of asphalt temperature upt 300C. Single measurement can be performed via instrument from panel and displayed on the builtin keyboard or optional printer Complete with C25 titanium bob stainless steel cup. Rotational speed: 0-1000 rpm Shear rate 1/s, s-1 4-1 , 200 Torque Range 0-10mNm Shear stress Pa 8-1, 500 Viscosity Pas 0.006-350 The heater temp range Amb. To 300°C Measurement system DIN 53019 C25 Serial interface RS232/USB Less Power consumption 4W (with Two years Warranty)
DIGI Modified Marshall Apparatus, for 4"/6" dia sample Marshall apparatus will be used to measure the resistance of cylindrical bituminous mix specimens to plastic flow under loading on the lateral surface. This test method is used for bituminous mix design. The test measures the maximum load supported by the test specimen at a loading rate of 50.8 mm/minute. Load is applied to the specimen till failure, and the maximum load is designated as stability. 100kN Single Speed machine. Sample dia 4”/6”. Complete with 3 set of compaction mould. (with Two years Warranty)
Pavement Core Drilling Machine The Pavement Core drilling machine should have following • Petrol engine powered for road building drill for the purpose of drilling test cores from or holes in roads, airport runways, bridges. • The machine should be complete with 6HP petrol engine • Low vibration. • Two vertical support columns to carry the drill head/engine. • Metal (rigid) base plate, leveling facility. • Suitable for vertically coring. • Suitable for depth of core upto 400mm • Variable drilling speed from 900 to 1200rpm • Bit diameter 150mm • Drill wrenches. • Water Tap. • Diamond Core Bits, 100mm dia x 200. (with Two years Warranty)
Automatic compactor: The equipment should be a Rugged construction to withstand hard work, Fully automatic and easy to operate, uniform compaction, automatic blow counter and automatically stops machine on completion. The drive mechanism should be capable of lifting the weight of 4.5 Kg and 10.2 kg and drops it through a height of 457mm. It should be capable of accommodating both 4” moulds. Suitable for operation on 230 V, 50Hz, Single phase, AC Supply. (with Two years Warranty)
Semi Automatic Ring and Ball Apparatus It should have magnetic stirrer with heating facility and digital display of temperature, and integral PID controlled for heating adjustment. (with Two years Warranty)
Centrifuge Extractor Compact with inbuilt dimmerstat for speed veration from 0 rpm to 3600 rpm. Capacity : 1500g (with Two years Warranty)
Ductility Testing Machine, Electrically Operated with Digital display It can perform three test specimens simultaneously. It should be electric motor driven. It should have electric pump circulator and heater. The temperature is controlled by digital temperature controller. (with Two years Warranty)
EIE INSTRUMENTS PVT. LTD
AIMIL LTD
BALAJI ENTERPRISES
Mass International
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .