Repair servicing and overhauling of 11 kv VCB panel board 11 KV HT isolators and voltage stabilizer installed at GZSA
2021_UDJK_121938_1
enit 499 dated 24-3-21
Open Tender
Electrical Works
Item Rate
45 days
Universty of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer university works department
₹11,500
14 Sept 2021
7 Apr 2021
6 May 2021
7 Apr 2021
5 May 2021
7 Apr 2021
Amount
Repair, overhauling and servicing of 11KV, 630A , HT ON LOAD Indoor/Outdoor type Isolator consisting of an oil chamber which houses the switch and air chamber where mechanism is fitted including dismantling, opening at workshop, any repair and replacement, filing of shortfall oil, painting including the transportation charges, insurance, all taxes applicable, loading and unloading by way of crane at site, workshop and vise versa. The service provider shall be responsible for any repair replacement during the defect liability period of one year.
Repairs, overhauling, servicing of the 800 KVA, 11 KV natural oil cooled rolling type automatic voltage stabilizer outdoor type, balanced supply, unbalanced load and copper wound with stepless control of voltage and power having hand control and automatic control, raise and lower push button control, electronic relay for automatic correction of flucation type of HT Voltage Stabilizer unit including dismantling the unit, opening the same in the workshop, cleaning of all mechanical and electrical parts, repair/painting of complete set, repair and replacement of the parts such as motor, RC, Micro Switches, Cork-Sheets, checking the level of transformer oil, filling of dehydrated transformer oil as per the quantity, motor, relays, control circuits rewinding of the damaged winding if any of the stabilizer and dimmer including the transportation charges, insurance, all taxes applicable, loading and unloading by way of crane at site, workshop and vise versa. The service provider shall be responsible for any repair replacement during the defect liability period of one year.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .