Executive Engineer
Executive Engineer PWD Gandhi Nagar I/c UWD
Repair and renovation of seminar hall of scholars room and library of Urdu department Electrical work
2026_UDJK_299597_1
enit 120 dated 23-12-2025
Open Tender
Electrical Works
90 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹708
Executive Engineer PWD Gandhi Nagar I/c UWD
₹8,040
27 Jan 2026
1 Jan 2026
12 Jan 2026
1 Jan 2026
10 Jan 2026
1 Jan 2026
Part-A (Sanctioned Schedule items) Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /KEI/Polycab, Conduit Make - ISI Marked Anchor/High Power /AKG) Equivalent make of required specification to be approved by the Engineer In charge) i.Group ‘A’
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG/) Equivalent make of required specification to be approved by the Engineer In charge 25 mm dia
Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (Wire Make ISI Marked Havells/Anchor/KEI/polycab Equivalent make of required specification to be approved by the Engineer In charge ) i. 2x1.5 +1x1.5 Sq mm
i. 2x2.5+ 1x2.5 Sq mm
ii. 2x6 +1x6 Sq mm
iv. 4x16+ 2x6 Sq mm
Supply and Fixing following ratings, Four pole, 415V volts, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as reqd. a.63 Amp 415 volt Four Pole Isolator. (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Supply and fixing of metal Box of following size(nominal size) on the surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 100mm x 100mm x 60mm deep
200mm x 125mm x 60mm deep
ii.15/16 Amp Switch
iv.6 pin 15/16 Amp Socket
Supplying and fixing following way, horizontal type three pole and neutral,sheet steel,MCB distribution board,415 V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators) ( Havells/Anchor /I.A /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 6 way(4+18), Double door
ii. 8 way(4+24), Double door
Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (Wire Make ISI Marked Havells/HPL/Anchor/KEI/Polycab/ Equivalent make of required specification to be approved by the Engineer In charge) i 1x1.5 sqmm
iii.2x6 sqmm
Supply & fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make Havells/ Anchor /Major Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge)
Re-wiring for light point/fan point/call bell point exhaust fan point with 1.5 Sqm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Wire Make ISI Marked Havells/Anchor/KEI/Polycab ) (Conduit Make - ISI Marked Anchor/High Power /AKG) Group ‘C’
Non-Schedule Items Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) 4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete .
2 feet 9 to 12 watt ,230 volts LED batten type tube light fitting complete
18 Watt LED recessed/surface mounting 6500 K, 240 Volts as per cat : Slim Panel down light fittings/luminaries square or round (225x225)mm to (300x300)mm Dimensions.
b. 600mmX600mm surface mounted LED luminaire CRCA sheet housing comprising of White (WH) LED’s connected in series parallel. Opal diffuser fixed in separate CRCA sheet frame. Opal diffuser frame is held in with housing by screws for easy maintenance. Driver: Constant current LED driver. Finish: Housing white powder coated. (RAL9016). Fixture should have minimum system lumen of 4500lm & minimum efficiency at System level >=100lumens/ watt, Life of fixture : 50K Hrs. @ L70B50 Lumen maintenance, CCT 5700k with same lumens/w. CRI >80, THD <10%@ 240v ac. An operating Voltage Range of 140 - 270 V. Minimum Internal Surge Protection 3kv, IP 20. BIS and OEM certification is required for LED Driver & Luminaire, As similar to Bajaj BZSSQL 45L/Philips/Havewlls/equivilant make of required specification to be approved by engineer in charge 36W
Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient .(Make: Havells /Anchor/USHA /Crompton) Equivalent make of required specification to be approved by the Engineer In charge)
Supply, installation, testing, commissioning of heavy duty 300 mm sweep BEE 1 to 3 star rated energy efficient exhaust fan. Make: ( Anchor/Havellls/Bajaj/Crompton Equivalent make of required specification to be approved by the Engineer In charge)
P/F following rating 230 volts energy saver LED Lamps and LED Tubes 4’ long (Make :Philip /Havells/Bajaj/ Surya/ Crompton/Compact/Halonix Equivalent make of required specification to be approved by the Engineer In charge) i.8 to12 watt LED
Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing following ways horizontal type MCB Distribution Board 415V on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. i.4 way, DD For A.C Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge
Supply and Fixing of Fan Down Rod Upto 2 feet Length including nut bolts and rubber insulator.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
BOQ_971871.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid