Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹36.8 LAccepted-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-1 | Accepted-Finance being lowest bidder | |
| 2 | L-2₹39.0 L+₹2.2 L (6.06%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L-2 | Rejected-Finance other than lowest bidder | |
| 3 | L-3₹39.2 L+₹2.4 L (6.63%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-3 | Rejected-Finance other than lowest bidder | |
| 4 | L-4₹39.8 L+₹3.0 L (8.19%)Rejected-Finance | L-4 | Rejected-Finance other than lowest bidder | |
| 5 | L-5₹39.9 L+₹3.1 L (8.43%)Rejected-Finance | L-5 | Rejected-Finance other than lowest bidder |
| Sl No | Description | Qty | Unit | KWALITY CONSTRUCTION L7 | INDIA ELECTRICAL EQUIPMENTS L8 | M/S J S ENTERPRISES L1 | Rounaq Enterprise L5 | ELECTRO FREEZE L6 | EASTERN REFRIGERATION AND ELECTRICAL CO L3 | SUDHA ENTERPRISES L2 | MAKLOYED ELECTRICAL ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning of Air Curtain on entrance door with all wiring, accessories and mounting arrangement. The width of the air curtain shall be 1800 mm. The wiring will be done using 2.5 Sqmm x 3 core unarmoured cable from the provided power point including 16A, 3 pin plug top but not exceeding 2.5m in length. The Air Curtain will be mounted in a safe and sound manner using MS Anchor Fastener (minimum 3 Nos) complete in all respect as directed by the department with all neccessary fixing arrangement of door opening size 70"x90" complete all as specified and directed with the following specifications:-
(a) Dimension (mm) -1800x230x212
(b) Maximum air velocity -21 m/s
(c) Noise lavel(db) -50-70 db
(d) Body Material: 304 Stainless Steel.
(e) Width Size: 6 Feet
(f) No of Blowers: 6
(g) Nof of Motors : 3
(h) HP: 1.12
(j) Voltage: 220v / 50 HZ
(k) No of Shafts: 1 Single + 1 Double
(l) Power Watage: 820 W
(m) Phase: Single
(n) RPM (Max / Min): 2700/ 2100
(o) Blower Material: ABS
(p) CFM : 1490
(q) %Insect / Dust Rejection: 75%
(r) Weight Kgs : 32
Note: Rates of Air Curtains shall be deemed to be inclusive of the cost of 02 years warranty/ AMC, including all spare parts, consumables, servicing, preventives maintenance, attending breakdown and replacement of defective componenets during Defect Liability Period (DLP) | 31 | Each Job | 1,18,000 ₹36,58,000 | 1,19,500 ₹37,04,500 | 1,07,000 ₹33,17,000 Lowest | 1,16,000 ₹35,96,000 | 1,17,200 ₹36,33,200 | 1,14,200 ₹35,40,200 | 1,13,500 ₹35,18,500 | 1,15,600 ₹35,83,600 |
| 2.00 | Supply, installation, testing & commissioning of Air Curtains on entrance door complete with all wiring, accessories and mounting arrangement. The width of the air curtain shall be 900 mm. The wiring will be done using 2.5 Sqmm x 3 core unarmoured cable from the provided power point including 16A, 3 pin plug top but not exceeding 2.5 m in length. The Air Curtain will be mounted in a safe and sound manner using MS Anchor Fastener (minimum 3 Nos) complete in all respect as directed by the department with all neccessary fixing arrangement of door opening size 34" x 90" complete all as specified and directed with the following specifications:-
(a) Dimension (mm) -900x230x212
(b) Maximum air velocity -21 m/s
(c) Noise lavel(db) -50-70 db
(d) Body Material: 304 Stainless Steel.
(e) Width Size: 3 Feet
(f) No of Blowers: 3
(g) Nof of Motors : 2
(h) HP: 1.12
(j) Voltage: 220v / 50 HZ
(k) No of Shafts: 1 Single + 1 Double
(l) Power Watage: 410 W
(m) Phase: Single
(n) RPM (Max / Min): 2700/ 2100
(o) Blower Material: ABS
(p) CFM : 825
(q) %Insect / Dust Rejection: 75%
Note: Rates of Air Curtains shall be deemed to be inclusive of the cost of 02 years warranty/ AMC, including all spare parts, consumables, servicing, preventives maintenance, attending breakdown and replacement of defective componenets during Defect Liability Period (DLP) | 4 | Each Job | 98,300 ₹3,93,200 | 98,000 ₹3,92,000 | 89,700 ₹3,58,800 Lowest | 97,400 ₹3,89,600 | 99,000 ₹3,96,000 | 94,800 ₹3,79,200 | 95,000 ₹3,80,000 | 98,300 ₹3,93,200 |
Tender Value
₹41.1 L
EMD Value
₹82,160
Closing Date
5 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
PROVN OF AIR CURTAINS AT CERTAIN LOCATION OF COMD HOSP (EC) UNDER GE (A) KOLKATA (SPECIAL WORK)
2026_MES_787355_1
GE/ALP (8729) KOLKATA OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Garrison Engineer Alipore
class D category c (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer Alipore
₹82,160
Yes
Garrison Engineer Alipore
5 Nov 2026
2 Sept 2026
7 Oct 2026
2 Sept 2026
5 Oct 2026
16 Sept 2026
2 Sept 2026 - 9 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing & commissioning of Air Curtain on entrance door with all wiring, accessories and mounting arrangement. The width of the air curtain shall be 1800 mm. The wiring will be done using 2.5 Sqmm x 3 core unarmoured cable from the provided power point including 16A, 3 pin plug top but not exceeding 2.5m in length. The Air Curtain will be mounted in a safe and sound manner using MS Anchor Fastener (minimum 3 Nos) complete in all respect as directed by the department with all neccessary fixing arrangement of door opening size 70"x90" complete all as specified and directed with the following specifications:- (a) Dimension (mm) -1800x230x212
(b) Maximum air velocity -21 m/s
(c) Noise lavel(db) -50-70 db
(d) Body Material: 304 Stainless Steel.
(e) Width Size: 6 Feet
(f) No of Blowers: 6
(g) Nof of Motors : 3
(h) HP: 1.12
(j) Voltage: 220v / 50 HZ
(k) No of Shafts: 1 Single + 1 Double
(l) Power Watage: 820 W
(m) Phase: Single
(n) RPM (Max / Min): 2700/ 2100
(o) Blower Material: ABS
(p) CFM : 1490
(q) %Insect / Dust Rejection: 75%
(r) Weight Kgs : 32 | 31 | Each Job | - | - |
| 2 | Supply, installation, testing & commissioning of Air Curtains on entrance door complete with all wiring, accessories and mounting arrangement. The width of the air curtain shall be 900 mm. The wiring will be done using 2.5 Sqmm x 3 core unarmoured cable from the provided power point including 16A, 3 pin plug top but not exceeding 2.5 m in length. The Air Curtain will be mounted in a safe and sound manner using MS Anchor Fastener (minimum 3 Nos) complete in all respect as directed by the department with all neccessary fixing arrangement of door opening size 34" x 90" complete all as specified and directed with the following specifications:- (a) Dimension (mm) -900x230x212
(b) Maximum air velocity -21 m/s
(c) Noise lavel(db) -50-70 db
(d) Body Material: 304 Stainless Steel.
(e) Width Size: 3 Feet
(f) No of Blowers: 3
(g) Nof of Motors : 2
(h) HP: 1.12
(j) Voltage: 220v / 50 HZ
(k) No of Shafts: 1 Single + 1 Double
(l) Power Watage: 410 W
(m) Phase: Single
(n) RPM (Max / Min): 2700/ 2100
(o) Blower Material: ABS
(p) CFM : 825
(q) %Insect / Dust Rejection: 75% | 4 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_882413.xls
BOQ • 1.45 MB
tenderdoc.pdf
Tender Documents • 0.69 MB
corrigendum_8729.pdf
PDF • 0.92 MB
corrigendum_8729.pdf
PDF • 0.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .