Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
8 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO. GE (I) (AF)/SHL/ OF 2022-23 PERIODICAL MAINTENANCE / REPAIRS OF TRANSFORMER, VOLTAGE STABILIZER, APFC AND ALLIED WORKS AT AF STN LAITKOR PEAK UNDER GE (I) (AF) SHILLONG
2022_MES_545103_1
8039/22/SHL/2022/23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
LAITKOR PEAK SHILLONG
For Enlisted Contractors Class E Category b ii and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I) (AF) SHILLONG
₹36,000
Yes
12 Sept 2022
12 Aug 2022
10 Sept 2022
12 Aug 2022
8 Sept 2022
25 Aug 2022
12 Aug 2022 - 18 Aug 2022
Amount
M & L for disconnecting all incoming and outgoing cables of transformers of following capacities at various locations installed on two pole/four pole structures/on platforms at Station, opening the top cover, carrying out following activities :- (a) Draining out all the transformer oil to clean barrel for reuse. (b) Dismantling of all attachment viz breather assy, conservator, oil temperature gauge, HT/LT bushing etc and keeping aside for re-use and re-assembling the serviceable dismantled parts/new spare by providing new insulation materials, gasket, nuts & bolts etc. (c) Inspection of transformer core and winding, drying out transformer core and winding in vacuum chamber till specified IR values are obtained. (d) Cleaning of complete transformer tank, oil fins, removing of sludge and making the inside surface of tank dry by blowing of hot air as directed. Note : Dehydration of collected transformer oil shall be measured and paid under respective item of BOQ here-in-after.
Transformer of capacity 100 KVA
Transformer of capacity For 200 KVA
Transformer of capacity For 315 KVA
Transformer of capacity For 400KVA
Transformer of capacity For 630 KVA
M & L for disconnecting all incoming and outgoing cables of Voltage stablizers of following capacities at various locations installed on two pole/four pole structures/on platforms at Station, opening the top cover, carrying out following activities :- (a) Draining out all the transformer oil to clean barrel for reuse. (b) Dismantling of all attachment viz breather assy, conservator, oil temperature gauge, HT/LT bushing etc and keeping aside for re-use and re-assembling the serviceable dismantled parts/new spare by providing new insulation materials, gasket, nuts & bolts etc. (c) Inspection of transformer core and winding, drying out transformer core and winding in vacuum chamber till specified IR values are obtained. (d) Cleaning of complete transformer tank, oil fins, removing of sludge and making the inside surface of tank dry by blowing of hot air as directed. Note : Dehydration of collected transformer oil shall be measured and paid under respective item of BOQ here-in-after.
Automatic Voltage stablizers of capacity 630 KVA
Automatic Voltage stablizers of capacity 400 KVA
Automatic Voltage stablizers of capacity 200 KVA
M & L for removing of the transformers of following capacities at various locations installed on two pole/four pole structures/on platforms at Station and loading it in the vehicle carefully using crane and transporting it to the workshop for HV/LV re-winding, transport the transformer back to the site , install it complete all as specified and directed :- Notes : (a) M & L for Cost of re-winding shall be measured and paid for separately under respective item of BOQ here-in-after. (b) All other repair work and replacement of spares/components shall be measured and paid for separately under respective items of BOQ.
Transformer of capacity upto 200KVA
M & L for re-winding HV/LV coils of transformers with super enameled copper wire as per the existing gauge and as per laid down standards incl re-insulating with suitable insulating material, complete all as directed
Supply only HT bushing poreclain with copper stud, nuts, bolts, washers, gasket, oil seal {set of three ( For 03 Phases)} suitable for following capacity transformer complete all as specified and directed:-
Transformer of capacity 100 KVA
Transformer of capacity For 200 KVA
Transformer of capacity For 315 KVA
Transformer of capacity For 400 KVA
Transformer of capacity For 630 KVA
Supply only LT bushing poreclain with copper stud, nuts, bolts, washers, gasket, oil seal SET OF FOUR (For 3 Phase and one for neutral) suitable for following capacity transformer complete all as specified and directed:-
Transformer of capacity 100 KVA
Transformer of capacity For 200 KVA
Transformer of capacity For 315 KVA
Transformer of capacity For 400 KVA
Transformer of capacity For 630 KVA
Supply only Motor of existing size and type for following capacity voltage stablizers complete all as specified and directed:-
Automatic Voltage stablizers of capacity 630 KVA
Automatic Voltage stablizers of capacity 400 KVA
Automatic Voltage stablizers of capacity 200 KVA
Supply only Relay card of existing size and type for following capacity voltage stablizers complete all as specified and directed:-
Automatic Voltage stablizers of capacity 630 KVA
Automatic Voltage stablizers of capacity 400 KVA
Automatic Voltage stablizers of capacity 200 KVA
Supply only temperature gauge of existing size and type for measuring temperature 0 to 100 degree centigrade for following capacity transformer complete all as specified and directed:-
Transformer of capacity 100 KVA to 200 KVA
Transformer of capacity For 315 KVA
Transformer of capacity For 400 KVA
Transformer of capacity For 630 KVA
Supply only MS bolts, nuts and washers as per existing size and length all as directed.
M & L for on site centrifusing (dehydration) of old transformer oil at various locations of transformers of Capacity 100 KVA to 630 KVA installed on two pole/four pole structures/on platforms at Station filter action using automatic centrifusing (dehydration) machine to achieve min 40 KV breaking voltage (di-electric strength) at 2.5 mm gap for 2 minutes by absorbing and abolishing all sludge particles for use as per BS-B 66-1983 complete all as specified and directed. Notes : (a) All disconnection/re-connection of transformers HT/LT cables, T & P for required for above activity shall be arranged by contractor and quoted rates deemed to include for same. (b) Dielectric strength of the oil to be tested at site in presence of Engineer-in-charge without any extra cost and recorded the same.
Supply and fill new transformer oil ISI Marked (for topping up) confirming to IS-335 of 1993, low viscosity with dielectric strength 50 KV breaking voltage in 2.5mm gap for 2 minutes filled in transformer at various locations in Station, refixing of top cover and testing, complete all as specified and directed. (Note :- Dielectric strength of the oil to be tested at site in presence of Engineer-in-charge without any extra cost and recorded the same.)
Supply & fixing of cork/rubber gasket 4mm thick for top cover and other joints for transformers of capacity upto upto 630 KVA,11/0.433 KV complete all as specified and as directed.
M&L for preparation of old surfaces by scraping, removing, cleaning, of oil, grease painting of transformer internally and externally and applying two coat of heat resistant synthetic enamel paint of colour as directed by spray painting including writing MES No and SM No on transformer body with synthetic enamel paint complete all as specified and directed for following capacities transformer:-
Transformer of capacity upto 250 KVA rating
Transformer of capacity exceeding 315 KVA and upto 400 KVA..
Transformer of capacity 630 KVA.
Servo Voltage stablizer of capacity 200 KVA and upto 630 KVA
Supply only heavy duty Silica gel breather assembly (transparent type) suitable for transformer of following capacity complete all as specified and directed:-
Transformer of capacity upto 200 KVA rating
Transformer of capacity exceeding 315 KVA and upto 630 KVA.
Supply only Silica gel for breather assembly (transparent type) in granular form for transformers complete all as specified and directed
M & L for earthing complete with Copper earth plate 60 cm X 60 cm X 3.15 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to copper earth strip of size 20mmx3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI/CI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
M & L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as specified and directed
Distmantling and taking down old cross arms, bracing support clamps and back plates from poles etc, complete all as directed.
Supply and fixing MS structural steel work in cross arms, bracings, supports, clamps and back plates fabricated (with drilled holes hot and cold etc) from channel/angle iron sections of various size and shape FI clamps (full, half 'D' and earth clamp etc) including necessary MS bolts, nuts, washer etc and painting with two coats of aluminium paint over one coat of red oxide primer complete all as directed.
Excavation in trenches in soft / loose soil, not exc 1.5 m wide and n. exc 1.5 m depth or n exc 10 Sqm on plan & getting out, for laying of cables, foundations of poles, struts, stays etc. and getting out including triming and forming bottom surface complete, all as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested complete all as directed.
Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point in soils complete all as directed.
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
Supply and laying factory made ISI marked un-reinforced precast concrete cable covers class HV type I flat of size 300mm x 180mm x 40mm complete all as specified and directed.
S & F in replacement Galvanised steel tubing light grade for protection of under ground cable on poles / walls/under road crossing/laid in trenches etc conforming to IS-1239 for size 80mm bore complete all as directed:-
Taking out old unserviceable HT UG cable and Supplying, Fixing/laying, jointing and testing and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 sq. mm, 3 core complete all as specified and directed
Taking out old unserviceable LT UG cable and Supplying, Fixing/laying, jointing and testing and commissioning, LT under ground cables, 1100 Volts grade, XLPE insulated, armoured heavy duty electric cable with stranded aluminuim conductors, laid in trenches, ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe complete all as specified and directed of following sizes:- Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule.
3.5 core 95 Sqmm
3.5 core 120 Sqmm
M & L in replacement for outdoor type cold shrinkable cable end termination jointing kit for LT 1100 Volts (Earthed) grade cable of following size complete with jointing material and accessories complete all as directed :-
50 to 95 Sqmm, 3.5 core
120 to 185 Sqmm, 3.5 core
M & L in replacement for indoor type heat shrinkable cable end termination jointing kit for LT 1100 Volts (Earthed) grade cable of following size complete with jointing material and accessories complete all as directed :-
50 to 95 Sqmm, 3.5 core
120 to 185 Sqmm, 3.5 core
Taking out old unserviceable/deformed mild steel duct cover plates and S & F Plates (plain or chequered) channels, conforming to Fe-290 (Gde E-165), Square cut or notched (ordinary and counter sunk) forming holes, without any attachment with lifting arrangement in any shape as directed including grinding the sharp edges and painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specifed and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m all as specified and directed.
Supply only self bouding EPR (Ethylene Propylene Rubber) HT tape roll of sze 19mm x 10m. Make : 3M or equivalent from Dension / Raychem
Taking down all parts of APFC Panels any capacity including existing wiring and M & L for preparation of old existing door, inner & outer steel or iron surfaces of APFC Panels in position including removal of disintegrated and deteriorated paint by scrapping out with wire brush or iron scrubber, applying a coat of red oxide primer and one under coat, one finish coat of synthetic enamel paint with spray gun machine for smooth finish including writing letter and complete re-assembling of APFC Panels any capacity by refixing the old serviceable parts/new parts with complete rewiring of APFC Panels with 1.5/2.5/6 sqmm (as per existing size) Heat Resistant Flame Retardant HRFR PVC Insulated Industrial Cables multistranded copper conductor cable PVC insulated and unsheathed 1100 volts grade conforming to IS-694 with appropriate sleeves, copper lugs pin/ring type as required including marking Nos, spiral PVC conduit, PVC clamps, proper alingnment of wires and testing after re-assembling the APFC Panels complete all as specified and directed. Notes : (a) Cost of labour for replacement of new spares/component shall be deemed to be included in quoted rates. (b) New spare parts/components shall be measured and paid as Supply only under respective items of BOQ
Supply only following spares/components in APFC Panels any capacity complete all as specified and as directed :-
Flush mount digital Ammeter 0-200 Amps (size 96mm x 96mm)
Flush mount digital voltmeter 0-500 Volts (size 96 mm x 96 mm)
MCB TP 6 to 32 Amps, 415 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I
MCB TP 63 Amps, 415 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I
APFC relay 12 Steps for contactor controlled APFC Panels, auto programmable, single CT input 1/5 Amps, Input voltage 415 Volts AC supply Model & Make : Model No. etaSMART Cat Part No. CS90903OOOO of Make L & T or equivalent model of Makes listed in List of Makes.
APFC relay 8 Steps for contactor controlled APFC Panels, auto programmable, single CT input 1/5 Amps, Input voltage 415 Volts AC supply Model & Make : Model No. etaSMART Cat Part No. CS90902OOOO of Make L & T or equivalent model of Makes listed in List of Makes.
MPP standard duty capacitor cylindrical 25 KVAR, 3 phase, 440 Volts, 50 Hz with rectangular/circular steel container
MPP standard duty capacitor cylindrical 20 KVAR, 3 phase, 440 Volts, 50 Hz with rectangular/circular steel container
MPP standard duty capacitor cylindrical 15 KVAR, 3 phase, 440 Volts, 50 Hz with rectangular/circular steel container
MPP standard duty capacitor cylindrical 12.5 KVAR, 3 phase, 440 Volts, 50 Hz with rectangular/circular steel container
MPP standard duty capacitor cylindrical 7.50 KVAR, 3 phase, 440 Volts, 50 Hz with rectangular/circular steel container
MPP standard duty capacitor cylindrical 5 KVAR, 3 phase, 440 Volts, 50 Hz with rectangular/circular steel container
Capacitor duty contactor 440 Volts, 3 phase, 50 Hz with built-in auxillary contacts 1NO for 25 KVAR rating . Model & Make : Model No. MO C25 Cat Part No. CS96322 of Make L & T or equivalent model of Makes listed in List of Makes.
Capacitor duty contactor 440 Volts, 3 phase, 50 Hz with built-in auxillary contacts 1NO for 20 KVAR rating . Model & Make : Model No. MO C20 Cat Part No. CS90021 of Make L & T or equivalent model of Makes listed in List of Makes.
Capacitor duty contactor 440 Volts, 3 phase, 50 Hz with built-in auxillary contacts 1NO for 15 KVAR rating . Model & Make : Model No. MO C15 Cat Part No. CS90019 of Make L & T or equivalent model of Makes listed in List of Makes
Capacitor duty contactor 440 Volts, 3 phase, 50 Hz with built-in auxillary contacts 1NO for 12.5 KVAR rating. Model & Make : Model No. MO C12.5 Cat Part No. CS96321 of Make L & T or equivalent model of Makes listed in List of Makes.
Capacitor duty contactor 440 Volts, 3 phase, 50 Hz with built-in auxillary contacts 1NO for 8.5 KVAR rating . Model & Make : Model No. MO C8.5 Cat Part No. CS96320 of Make L & T or equivalent model of Makes listed in List of Makes.
Capacitor duty contactor 440 Volts, 3 phase, 50 Hz with built-in auxillary contacts 1NO for 5 KVAR rating . Model & Make : Model No. MO C5 Cat Part No. CS96127 of Make L & T or equivalent model of Makes listed in List of Makes.
Copper wound round type CT of ratio 100/5A
Copper wound round type CT of ratio 300/5A.
M/S DEEDAR ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .