Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-Finance | L1 | Accepted-Finance accepted | |
| 2 | L2₹27.5 L+₹1.2 L (4.63%)Accepted-Finance NO 87 NEW BALAJI NAGAR ATTIPATTU CHENNAI 600 120 | CHENNAI | CHENNAI | TAMIL NADU | 600120 | L2 | Accepted-Finance accepted |
| Sl No | Description | Qty | Unit | E GNANAMANI L1 | A.R.C.ENGINEERING L2 |
|---|---|---|---|---|---|
| 1.00 | Cleaning replacement of of 40 W Fluorescent to 18 W LED Tube light and 70W SV lamp to 36 W LED well glass lamp fittings including transport of materials | 800 | Nos | 278 ₹2,62,432 Lowest | 290 ₹2,73,760 |
| 2.00 | Replacement of burnt/failed MCBs in LP boxes at various places of Power house area lighting ( Service building, station building,TG floor of all the three Units and Switch yard etc.,) | 60 | Nos | 208 ₹14,726.4 Lowest | 218 ₹15,434.4 |
| 3.00 | Rewiring of LP including dismantling at various places of Power house area lighting etc., | 40 | Nos | 1,503 ₹70,941.6 Lowest | 1,572 ₹74,198.4 |
| 4.00 | Cleaning and tightness checking of LDB | 26 | Nos | 2,999 ₹92,009.32 Lowest | 3,136 ₹96,212.48 |
| 5.00 | Replacement roof extraction fan provided at TG floor of all the three units | 40 | Nos | 1,800 ₹84,960 Lowest | 1,882 ₹88,830.4 |
| 6.00 | Circuit fault rectification of roof extraction fan motors at TG floor | 40 | Nos | 1,000 ₹47,200 Lowest | 1,045 ₹49,324 |
| 7.00 | Cleaning, Lubricating, tightness of bolt & Nut of roof extraction fan motor at TG floor of all the three units | 280 | Nos | 695 ₹2,29,628 Lowest | 726 ₹2,39,870.4 |
| 8.00 | Replacement of exhaust fan at cable gallery at '0' mtr, 10.5 mtr for all the three units and AC plant | 10 | Nos | 1,000 ₹11,800 Lowest | 1,045 ₹12,331 |
| 9.00 | Circuit fault rectification of exhaust fan at cable gallery at '0' mtr and 10.5 mtr for all the three units. | 24 | Nos | 600 ₹16,992 Lowest | 627 ₹17,756.64 |
| 10.00 | Cleaning, lubricating, tightness checking of exhaust fan at Cable Gallery at '0' mtr and 10.5 mtr for all the three units. | 84 | Nos | 695 ₹68,888.4 Lowest | 726 ₹71,961.12 |
Tender Value
Refer Docs
EMD Value
₹22,600
Closing Date
15 Sept 2026, 2:00 pmClosed
SE/ES/NCTPS-I
SE/ES/NCTPS-I,Chennai-120
NCTPS 1 EM II Dn SD III PHL Carrying out Routine maintenance works of lighting in Power House area comprising of Station Service buildings Cable Gallery TG floor of all the three Units Switchyard and Transformer yard for a period of 360
2026_EB_699880_1
CE/NCTPS-I/SE/ES/WC-56/2026-27
Open Tender
Power/Energy Projects/Products
Works
360 days
NCTPS-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹22,600
Yes
30 Sept 2026
31 Aug 2026
16 Sept 2026
31 Aug 2026
15 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cleaning replacement of of 40 W Fluorescent to 18 W LED Tube light and 70W SV lamp to 36 W LED well glass lamp fittings including transport of materials | 800 | Nos | 252.56 | ₹2,02,048 |
| 2 | Replacement of burnt/failed MCBs in LP boxes at various places of Power house area lighting ( Service building, station building,TG floor of all the three Units and Switch yard etc.,) | 60 | Nos | 189.42 | ₹11,365.2 |
| 3 | Rewiring of LP including dismantling at various places of Power house area lighting etc., | 40 | Nos | 1,366.75 | ₹54,670 |
| 4 | Cleaning and tightness checking of LDB | 26 | Nos | 2,726.9 | ₹70,899.4 |
| 5 | Replacement roof extraction fan provided at TG floor of all the three units | 40 | Nos | 1,636.14 | ₹65,445.6 |
| 6 | Circuit fault rectification of roof extraction fan motors at TG floor | 40 | Nos | 908.97 | ₹36,358.8 |
| 7 | Cleaning, Lubricating, tightness of bolt & Nut of roof extraction fan motor at TG floor of all the three units | 280 | Nos | 631.4 | ₹1,76,792 |
| 8 | Replacement of exhaust fan at cable gallery at '0' mtr, 10.5 mtr for all the three units and AC plant | 10 | Nos | 908.97 | ₹9,089.7 |
| 9 | Circuit fault rectification of exhaust fan at cable gallery at '0' mtr and 10.5 mtr for all the three units. | 24 | Nos | 545.38 | ₹13,089.12 |
| 10 | Cleaning, lubricating, tightness checking of exhaust fan at Cable Gallery at '0' mtr and 10.5 mtr for all the three units. | 84 | Nos | 631.4 | ₹53,037.6 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_841308.xls
BOQ • 0.35 MB
corrigendum.pdf
PDF • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .