Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹38.0 L+₹2.1 L (5.77%)Rejected-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹39.9 L+₹3.9 L (10.9%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹41.4 L+₹5.4 L (15.0%)Rejected-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | L4 | Rejected-AOC L4 Bidder | |
| 5 | L5₹43.8 L+₹7.8 L (21.7%)Rejected-AOC | L5 | Rejected-AOC L5 Bidder |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
23 Jun 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
SPECIAL REPAIR/REPLACEMENT TO LT PANEL AND ALLIED WORKS AT DIPAS AND DSC LINE SUB-STATION OF ZONE B AREA UNDER GE I RND DELHI
2020_MES_345404_1
GE/RND-18/DLI/2020-2021
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class D, Cat b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹95,000
Yes
18 Aug 2020
16 May 2020
25 Jun 2020
16 May 2020
23 Jun 2020
18 Jun 2020
Amount
Supply, installing, testing and commissioning factory made and tested LT panel Indoor type approx size 2100x1000x1600mm platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 2000 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and inner sheet made out of 2.00 mm thick CRCA mild steel sheet and mild steel Mounting Channel frame work made out of MS angle iron 75X40 mm duly coated with zinc metal coating, front opening type for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals, Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipments/ instruments. Each compartment shall be numbered/ letterd as per the approved drg. Affixing MV Danger plate as suitable intervals/ location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 2.5 sqmm complete. All steel metal works including frame shall be painted with anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engineer-in- charge & including taking down the Old rusted panel from it's position & including taking proper shutdown complete all as specified and as directed.
BUS BAR CHAMBER:- (a) 2000 Amps 3 phase & 1 Neutral 2000 Amps, Aluminium conductor E-91 grade, with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, KWH, KVAH, KVAR etc. 3 Phase - 01 Set. (ii) C.T's of capacity 1600/5 A Cl 1.0 - 01 Set. ( Set of three ) (iii) Red, Yellow, Green Phase indicating Lights LED type 220 V 50 Hz - 1 Set. ( Set of three ). (iv) Suitable Protection MCB C Series- 1 Set. ( Set of three ). INCOMING SUPPLY :- (i) ACB 1600 Amps, breaking capacity 50 KA 4 Pole, Manual Draw Out (MDO) with Microprocessor based LCD protection release 415 volts, 50Hz = 01 No., Make of ACB:-L&T/ Siemens/Legrand BUS COUPLER :- (i) ACB 1600 Amps, breaking capacity 50 KA 4 Pole, Manual Draw Out (MDO) Thermal release 415 volts, 50Hz= 01 No., Make of ACB:-L&T/ Siemens/Legrand.
INTERLOCKING:- (i) Complete Electrically and Mechanically Interlocking between Incoming supply and Bus Coupler= 1 Set. OUTGOING SUPPLY:- (i) MCCB 800 Amps, 36 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 03 Nos., (ii) MCCB 630 Amps, 36 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 02 Nos., (iii) MCCB 200 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 01 No., Make of MCCB:- L&T/ Siemens/ Legrand.
Supply, installing, testing and commissioning factory made and tested LT panel Indoor type approx size 1500x1000x1675mm, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 1500 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and inner sheet made out of 2.00 mm thick CRCA mild steel sheet and mild steel Mounting Channel frame work made out of MS angle iron 75X40 mm duly coated with zinc metal coating, front opening type for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals, Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipments/ instruments. Each compartment shall be numbered/ letterd as per the approved drg. Affixing MV Danger plate as suitable intervals/ location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 2.5 sqmm complete. All steel metal works including frame shall be painted with anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engineer-in- charge, including taking down the Old rusted panel from it's position after taking proper shutdown complete all as specified and as directed.
BUS BAR CHAMBER:- (a) 1500 Amps 3 phase & 1 Neutral 1500 Amps, Aluminium conductor E-91 grade, with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, KWH, KVAH, KVAR 3 Phase - 01 Set. (ii) C.T's of capacity 1250/5 A Cl 1.0 - 01 Set. ( Set of three ) (iii) Red, Yellow, Green Phase indicating Lights LED type 220 V 50 Hz - 1 Set. ( Set of three ). (iv) Suitable Protection MCB C Series- 1 Set. ( Set of three ). INCOMING SUPPLY :- (i) ACB 1250 Amps, breaking capacity 50 KA 4 Pole, Manual Draw Out (MDO) with Microprocessor based LCD protection release 415 volts, 50Hz = 01 No., Make of ACB:-L&T/ Siemens / Legrand/Schneider. OUTGOING SUPPLY :- (i) MCCB 630 Amps, 36 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS= 100%ICU = 01 No. (ii) MCCB 400 Amps, 36 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS= 100% ICU = 03 Nos. (iii) MCCB 200 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100%ICU = 01 No. (iv) MCCB 100 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100%ICU = 02 Nos. Make of MCCB:- L&T/ Siemens/ Legrand.
Supply, installing, testing and commissioning factory made and tested LT panel Indoor type approx size 1200x500x1700mm, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 500 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and inner sheet made out of 2.00 mm thick CRCA mild steel sheet and mild steel Mounting Channel frame work made out of MS angle iron 75X40 mm duly coated with zinc metal coating, front opening type for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals, Air ventilation breathers to be provide for heat dissipation. Suitable sized knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipments/ instruments. Each compartment shall be numbered/ letterd as per the approved drg. Affixing MV Danger plate as suitable intervals/ location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 2.5 sqmm complete. All steel metal works including frame shall be painted with anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engineer-in- charge, including taking down the Old rusted panel from it's position including taking proper shutdown complete all as specified and as directed.
BUS BAR CHAMBER:- (a) 500 Amps 3 phase & 1 Neutral 500 Amps, Aluminium conductor E-91 grade, with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, 3 Phase - 01 Set. (ii) C.T's of capacity 400/5 A Cl 1.0 - 01 Set. ( Set of three ) (iii) Red, Yellow, Green Phase indicating Lights LED type 220 V 50 Hz - 1 Set. ( Set of three ). (iv) Suitable Protection MCB C Series- 1 Set. ( Set of three ). INCOMING SUPPLY:- (i) MCCB 400 Amps, breaking capacity 36 KA 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS= 100%ICU = 01 No., Make of MCCB:-L&T/ Siemens / Legrand. OUTGOING SUPPLY :- (i) MCCB 100 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100%ICU = 06 Nos., (ii) MCB 40 Amps, 10 KA, 4 Pole, C Curve 220 volts, 50Hz, = 03 Nos., Make of MCCB & MCB :- L&T/ Siemens/ Legrand.
Supply, installing, testing and commissioning factory made and tested LT panel outdoor type approx size 1200x500x1375mm, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 800 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and inner sheet made out of 3.15 mm thick CRCA mild steel sheet and mild steel Mounting Channel frame work made out of MS angle iron 75X40 mm duly coated with zinc metal coating, front opening type for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipments/ instruments. Each compartment shall be numbered/ letterd as per the approved drg. Affixing MV Danger plate as suitable intervals/ location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 2.5 sqmm complete. All steel metal works including frame shall be with painted anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engineer-in- charge, taking down the Old rusted panel from it's position including taking proper shutdown complete all as specified and as directed.
BUS BAR CHAMBER:- (a) 800 Amps 3 phase & 1 Neutral Strip 800 Amps, Aluminium conductor E-91 grade, with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, , 3 Phase - 01 Set. (ii) C.T's of capacity 600/5 A Cl 1.0 - 01 Set. ( Set of three ) (iii) Red, Yellow, Green Phase indicating Lights LED type 220 V 50 Hz - 1 Set. ( Set of three ). (iv) Suitable Protection MCB C Series- 1 Set. ( Set of three ). INCOMING SUPPLY:- (i) MCCB 630 Amps, breaking capacity 36 KA 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS= 100%ICU = 01 No., Make of MCCB:-L&T/ Siemens / Legrand OUTGOING SUPPLY:- (i) MCCB 250 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU= 01 No., (ii) MCCB 200 Amps, 36 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 01 No., (iii) MCCB 100 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 04 Nos., Make of MCCB:- L&T/ Siemens/ Legrand
Supply, installing, testing and commissioning factory made and tested LT panel Indoor type approx size 1550x1000x2075mm, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 1500 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and inner sheet made out of 2.00 mm thick CRCA mild steel sheet and mild steel Mounting Channel frame work made out of MS angle iron 75X40 mm duly coated with zinc metal coating, front opening type for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals, Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipments/ instruments. Each compartment shall be numbered/ letterd as per the approved drg. Affixing MV Danger plate as suitable intervals/ location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 2.5 sqmm complete. All steel metal works including frame shall be painted with anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engineer-in- charge, including taking down the Old rusted panel from it's position after taking proper shutdown complete all as specified and as directed.
BUS BAR CHAMBER:- (a) 1500 Amps 3 phase & 1 Neutral 1500 Amps, Aluminium conductor E-91 grade, with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER:- (i) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, 3 Phase - 01 Set. (ii) C.T's of capacity 800/5 A Cl 1.0 - 01 Set. ( Set of three ) (iii) Red, Yellow, Green Phase indicating Lights LED type 220 V 50 Hz - 1 Set. ( Set of three ). (iv) Suitable Protection MCB C Series- 1 Set. ( Set of three ). INCOMING SUPPLY:- (i) ACB 800 Amps, breaking capacity 50 KA 4 Pole, Manual Draw Out (MDO) with Microprocessor based LCD protection release 415 volts, 50Hz = 02 No. Make of ACB:-L&T/Siemens/Legrand BUS COUPLER:- (I) ACB 1250 Amps, breaking capacity 50 KA 4 pole, manual draw out (MDO). Thermal release 415 Volts. 50 HZ=01 No. Make of ACB: L&T/Siemens/Legrand INTERLOCKING:- Complete electrically and mechanically interlocking between incoming supply & Bus Coupler=1 Set
OUTGOING SUPPLY:- (i) MCCB 400 Amps, 36 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100% ICU = 02 Nos. (ii) MCCB 250 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100%ICU = 04 Nos. (iii) MCCB 200 Amps, 25 KA, 4 Pole, Adjustable type, thermal magnetic release 415 volts, 50Hz, ICS=100%ICU = 02 Nos. Make of MCCB:- L&T/ Siemens/ Legrand
Supply, installing, testing and commissioning indoor type Automatic Power Factor Correction (APFC) panel approx size 1100 x 600x1500mm Micro processor based power factor correction system of aggregate capacity: 225 KVAR in 8 stages having auto switching system for each stage in the form of electro magnetic making and breaking of contracts, as per varying load sensed by the microprossesor Electro magnetic switching system used for energizing each capacitor stage should have the carrying capacity not less than 1.5 times the charging current of the respective stage, Each switching stage shall carry a back up protection in the form of triple pole MCB of rating not less than 2 times the charging current of individual stage, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 400 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 2.00 mm thick CRCA mild steel sheet and mild steel Angle iron frame work made out of 40 X 40 X 5 mm), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 2.5 sqmm complete. All steel metal works including frame shall be with painted anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL-7035 shade including taking down the Old rusted panel from it's position after taking proper shutdown complete all as specified and as directed.
S&F in repairs multi functional meter ( Voltmeter, Ammeter, PF Meter, Hz Meter, KWH, KVAH, KVARH etc) digital type for frequency range (45-65 Hz) as per matching to existing one including all accessories and wiring complete all as specified and as directed. Make:- AE/L&T.
S&F in repair of LED type Indicating lamp type of voltage AC/DC set of RYB (set of three) as per matching to existing. Make:- L&T.
M&L for laying, connecting and testing XLPE insulated heavy duty, galvanised steel strip armoured LT 1100 volt grade with aluminium conductor multi stranded conforming to IS-7098 cables laid in ground through trenches/ pipes/ on walls/ poles including necessary lugs at termination of cable size 16 Sqmm 4 Core including taking out old unserviceable cables complete all as specified and directed.
M&L for laying, connecting and testing XLPE insulated heavy duty, galvanised steel strip armoured LT 1100 volt grade with aluminium conductor multi stranded conforming to IS-7098 cables laid in ground through trenches/ pipes/ on walls/ poles including necessary lugs at termination of cable size 50 Sqmm 3.5 Core including taking out old unserviceable cables complete all as specified and directed.
M&L for laying, connecting and testing XLPE insulated heavy duty, galvanised steel strip armoured LT 1100 volt grade with aluminium conductor multi stranded conforming to IS-7098 cables laid in ground through trenches/ pipes/ on walls/ poles including necessary lugs at termination of cable size 120 Sqmm 3.5 Core including taking out old unserviceable cables complete all as specified and directed.
M&L for laying, connecting and testing XLPE insulated heavy duty, galvanised steel strip armoured LT 1100 volt grade with aluminium conductor multi stranded conforming to IS-7098 cables laid in ground through trenches/ pipes/ on walls/ poles including necessary lugs at termination of cable size 185 Sqmm 3.5 Core including taking out old unserviceable cables complete all as specified and directed.
M&L for laying, connecting and testing XLPE insulated heavy duty, galvanised steel strip armoured LT 1100 volt grade with aluminium conductor multi stranded conforming to IS-7098 cables laid in ground through trenches/ pipes/ on walls/ poles including necessary lugs at termination of cable size 400 Sqmm 3.5 Core including taking out old unserviceable cables complete all as specified and directed. Note for Item No 11 to 15 : Earthwork, PCC cable cover, sand cushioning etc shall be measured and paid separately under relevant item of BoQ.
Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for laying cable complete all as specified and directed.
Excavation in hard dense soil/PCC/Bituminous road and taking out soil n. exc 1.5 mtr wide and n. exc. 1.5mtr in depth and getting out for laying of cable complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying in repair un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mmX 150mmX 40mm in trenches for cable protection keeping width of the cover parallel to the length of the cable complete all as specified and directed. Make:MEHTAB TILES/PEARLESS INDUSTRIES/HINDMOZAIC GUJRAT/JJCONCRETE LUCKNOW.
Supply and spread clean dry river sand in trenches including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
M&L for cement concrete Type B2 1:2:4 (40mm graded stone aggregate) for resurface of cable route including breaking/removal of old PCC complete all as specified and directed.
Supply and laying in repair GI pipe medium grade of 100mm dia including with all necessary fittings laid in trenches/ on surface for protection of UG cable complete all as specified and directed.
Supply and laying in repair GI pipe medium grade of 50mm dia including with all necessary fittings laid in trenches/ on surface for protection of UG cable complete all as specified and directed.
S&F in repair cable route indicator 15 cm dia made out cast aluminium duly marked with size and type of cable fixed on 40X 40X 6 mm angle iron support embedded in PCC 1:2:4 type B1(300X 300X 400 mm) and painted with two coats of anti corrosive paint over a coat of red oxide primer complete all as specified and directed.
M&L for earthing with Galvanised iron earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top edge of earth plate not less than 1.5 metre below GL connected to GI earth Strip 25 x 4 mm connected to earth plate electrode by means of GI nuts, bolts & washers, earth wire protected with & including 40 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long with & including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, mild steel handle of 8mm dia bar, watering arrangements with 20 mm GI medium grade pipe ISI marked, GI funnel with GI wire mesh, filling with mixture of common salt & charcoal, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as shown in electrical plate No 3 of MES Schedule Part I,
M&L for Earthing with Galvanised iron earth plate electrode 600 x 600 & 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL connected to GI wire 4 mm dia connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No 3 of MES Schedule Part I, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 B1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, mild steel handle of 8 mm dia bar, watering arrangements with 20 mm GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal with alternate layers including, necessary excavation and earth works in any type of soil, including test point, testing & commissioning complete all as specified and directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip including taking down old unserviceable complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 4 mm dia GI wire including taking down old unserviceable complete all as specified and directed.
Leo Air and Power Solution pvt Ltd.
Pradeep Bros
Vijaypower Generators Limited
JM enterprises
G M CONSTRUCTION COMPANY
KRISHANA ELECTRIC WORKS
Surjit and Sons
Rahul Enterprises
R. S. Associates
M/s Adhikari construction co.
Flint India
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .