| 1.00 | Supply, Fabrication, transporting, sand blasting with zinc painting of heavy section materials, including all consumables, labour, lead lift etc as directed by the Dept Engineer at site.(RSJ 250 x 125mm / 200 x 100m)(Sectional weight 14/Mtr & abovs) | 1.7 | MT | - |
| 2.00 | Fabrication,transporting, sand blasting with zinc painting of Light section materials, (MS Channel 125 x 65mm/100 x 50mm MS Plate,MS Angle various size.(Sectional weight below 14Kg/Mtr) including all consumables , labour, lead lift etc as directed by the Dept Engineer at site. | 9.2 | MT | - |
| 3.00 | Supply,transport,loading & unloading of MS Flat,(75 x 10mm/65 x 10mm and 50 x 8mm thick ) for earthmat & earth raiser to site including the cost of all materials , transport, labour, lead, lift etc., complete as directed by the Dept Engineer at site.( for both 230KV & 110KV) | 22.5 | MT | - |
| 4.00 | Supply& fabrication of earth electrode 6.00Mtr length t.port, loading & un loading of MS Round Rod (40mm) for earth electrode to the site including the cost of all materials , transport, labour,lead, lift etc., complete as directed by the Dept.Engineer at site. | 7.2 | MT | - |
| 5.00 | Labour charges for erection of Structure Heavy section sectional Wt/ 14Kg/ Mtr and above.(Under LC condition) | 1.7 | MT | - |
| 6.00 | Labour charges for erection of Structure Light section. sectional Wt/ 14Kg/ Mtr and above.(Under normal condition)including 230 & 110KV CVT structure. | 3.2 | MT | - |
| 7.00 | Labour charges for erection of Structure Light section. sectional Wt/ 14Kg/ Mtr and above.(Under LC condition) | 6 | MT | - |
| 8.00 | Erection of 110 KV SF6 circuit breakers (Complete shape) with MOM box & Terminal connectors using crane by own crane arrangement,link plate connection, including inter pole &, control cubical wiring, Evacuation, Gas filling, providing man power for testing whenever required & as directed by the field Engineer. | 1 | No | - |
| 9.00 | Erection of 230 KV CVT, Current Transformers & etc with Junction box & Terminal connectors using crane by own arrangement as per the field condition ,including other incidental charges providing man power for testing whenever required as directed by the field Engineer.(UnderLC condition) | 17 | Nos | - |
| 10.00 | Erection of 110 KV PT, Current Transformer, CVT with Junction boxes & Terminal connectors using crane by own arrangement as per the field condition, including providing man power for testing whenever required & as directed by the field Engineer(Under normal condition) | 11 | Nos | - |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
7 Jan 2020, 2:00 pmClosed
CE/TP-1
A10 Thiru vi ka Indl Estate Guindy Chennai 32
Supply and erection of RS Joist, MS channel, MS plate, supply of MS Flat, MS Rod, Erection of structure, earth mat, earth raiser, earth bore, stringing of 230 KV and 110 KV strung buses, droppers, jumpers, bus bars, erection of C and R panels at new
2019_EB_151862_1
TP1-60/2019-20
Open Tender
Electrical Works
Lump-sum
180 days
chennai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.1 L
23 Jan 2020
27 Dec 2019
8 Jan 2020
27 Dec 2019
7 Jan 2020
27 Dec 2019
Amount
Supply, Fabrication, transporting, sand blasting with zinc painting of heavy section materials, including all consumables, labour, lead lift etc as directed by the Dept Engineer at site.(RSJ 250 x 125mm / 200 x 100m)(Sectional weight 14/Mtr & abovs)
Fabrication,transporting, sand blasting with zinc painting of Light section materials, (MS Channel 125 x 65mm/100 x 50mm MS Plate,MS Angle various size.(Sectional weight below 14Kg/Mtr) including all consumables , labour, lead lift etc as directed by the Dept Engineer at site.
Supply,transport,loading & unloading of MS Flat,(75 x 10mm/65 x 10mm and 50 x 8mm thick ) for earthmat & earth raiser to site including the cost of all materials , transport, labour, lead, lift etc., complete as directed by the Dept Engineer at site.( for both 230KV & 110KV)
Supply& fabrication of earth electrode 6.00Mtr length t.port, loading & un loading of MS Round Rod (40mm) for earth electrode to the site including the cost of all materials , transport, labour,lead, lift etc., complete as directed by the Dept.Engineer at site.
Labour charges for erection of Structure Heavy section sectional Wt/ 14Kg/ Mtr and above.(Under LC condition)
Labour charges for erection of Structure Light section. sectional Wt/ 14Kg/ Mtr and above.(Under normal condition)including 230 & 110KV CVT structure.
Labour charges for erection of Structure Light section. sectional Wt/ 14Kg/ Mtr and above.(Under LC condition)
Erection of 110 KV SF6 circuit breakers (Complete shape) with MOM box & Terminal connectors using crane by own crane arrangement,link plate connection, including inter pole &, control cubical wiring, Evacuation, Gas filling, providing man power for testing whenever required & as directed by the field Engineer.
Erection of 230 KV CVT, Current Transformers & etc with Junction box & Terminal connectors using crane by own arrangement as per the field condition ,including other incidental charges providing man power for testing whenever required as directed by the field Engineer.(UnderLC condition)
Erection of 110 KV PT, Current Transformer, CVT with Junction boxes & Terminal connectors using crane by own arrangement as per the field condition, including providing man power for testing whenever required & as directed by the field Engineer(Under normal condition)
Erection of 110 KV PT, Current Transformer, CVT with Junction boxes & Terminal connectors using crane by own arrangement as per the field condition, including providing man power for testing whenever required & as directed by the field Engineer(Under LC condition)
Erection and alignment of 110 KV Isolators without earth, with terminal connecton, providing man power for testing whenever required & as directed by the field Engineer.(Under LC Condition)
Erection of 230KV LAS with moniter, Terminal connectors using crane by own arrangement as per the field condition, providing man power for testing whenever required & as directed by the field Engineer.
Erection of 110 KV LAS with moniter, Terminal connectors using crane by own arrangement as per the field condition, providing man power for testing whenever required & as directed by the field Engineer.
Erection of support/up right/under hang 230 KV insulators or disc insulator.(Under LC Condition)
Erection of support/up right/under hang 110 KV insulators(Under LC Condition)
Erection of 230 KV strung bus using Twin zebra conductor, fixing Bolted type Tension fitting & spacers (1Span -3ph x 2 Wire = 6 wires)including hoisting of insulators(Under LC condition).
Erection of 230 KV strung bus using Single zebra conductor, fixing Bolted type tension fitting (1Span -3ph x 1 Wire = 3 wires) including hoisting of insulators(Uder LC Condition).
Erection of 110 KV strung bus using Twin zebra conductor, fixing Bolted type Tension fitting & spacers (1Span -3ph x 2 Wire = 6 wires) and eye bolts etc.,)including hoisting of insulators(Under LC Condition).
Erection of 3 inch Aluminium bus with or without bend as per field condition(Under LC Condition)
Providing Jumper / Dropper by Zebra ACSR Conductor(Under LC Condition)
Labour machineries consumable for fabrication of earth electrode 10M/6M length or as directed by the field Engineer.
Labour machineries consumables for fabrication & erection of earth spike, including cost of labour , lead, lift etc.,complete as directed by the Dept.Engineer at site.(Under LC Condition)
Fabrication & Erection of Earth mat & earth raisers with 75 x 12 M.S. Flat , 65 x 10mm MS Flat & 50 x 8mm MS Flat as per the approved diagram.
Providing 140/150 mm dia. bore 5m/6m including labour, lead lift etc., including mobilization in all types of soil & labour for fabrication of earth electrode, insert the electrode in the bore and refilling the bore with red soil and bentonite powder 30 KG and other sundries items including providing earth tub for identification of location as directed by the field Engineer.
Erection of 230KV,110KV C & R Panels AC/DC/panel, Charger, etc.,
Labour ,tools for charging of battery 110V,300AH
Labour ,tools for erection of battery 110V,300AH
Laying of Control cables in duct / trench including the cost of Alu. Tag for identification,including cost of excavation & re filling of trench ave.0.3M & ave.depth 0.4M for cable laying below fixed yard level if necessary. Upto 8 core
Laying of Control cables in duct / trench including the cost of Alu. Tag for identification,including cost of excavation & re filling of trench ave.0.3M & ave.depth 0.4M for cable laying below fixed yard level if necessary. Above 8 core
Laying of control cable with suitable clamping in structure including the cost of Alu. Tag for identification, Upto 8 core
Laying of control cable with suitable clamping in structure including the cost of Alu. Tag for identification, Above 8 core
Labour for excavation and refilling of trench of average width of 0.3m and average depth of 0.8M for eartmat and 0.4 m for laying of cable below fixed yard level and of any size as required by field Engineer.
Labour for loading & unloading of Non- Fragile
Labour for loading & unloading of Fragile
Labour charges for painting earth raisers by green enamel painting including cost of paint (Dulex, Asian & berger preferred) & other consumables & as directed by the field engineer
Hire charges for crane provided (12 Tonne) for any erection loading, unloading, or shifting of equipments , done by department.
Manufacturing and supply of bolt of required length of 18 - 20 mm dia GI rod including cost of GI rod and 2Nos GI nuts & washer as directed by the field Engineer. Grout bolt & Eye bolt.
Supply and provision of M 8,M9,M10,M12, & M16 full thread GI bolt & nuts & GI Washer of various sizes for erection AB Switches & insulators and any other purpose wherever required and as dircted by the fIeld Engineer.
Fabrication supply & fixing of equipment board of various size & fire stand etc as per drawing & as directed by the Executive Engineer including cost of all materials.
Supply of L.C / Key board of 2100 mm (L) X 1000 mm (H), out of 75 X 25 mm Alu. Frame embedded with 12 mm pre laminated wood particle board using 2 nos. screw on rear side, Plain glass of 6 mm thick fixed with metal roller moving on Alu. Channel should be provided on front with locking arrangement, glass piece should be fastened on the glass shutters for opening & closing wall clamp made out of 7 mm plate should be provided. All the materials should be painted as directed by the Engineer
Labour charges for removing rust, primer coat, first & second coat painting both sides & in M.S.board RSJoist & yard light pole etc., including cost of enamel paint (Dulex,Asian,Berger preferred) and other consumables directed by the field Engineer.
Labour charges for writing details in finished surface on boards including cost of enamel paint(dulex, asian berger preferred)and other consumables as directed by The field engineer
Labour charges for drawing layout and writing details in LC/Keyboard including cost of enamel paint(Dulux,Asian, Berger preferred) and other consumables as directed by the field Engineer
Supply and erection of B class G.I pipe for extension of tandem/down pipe for AB switches and for any other purpose wherever required and as directed by field Engineer.including the cost of G.I Pipe. 50mm Dia
Supply & fixing of ISI mark backlite HRC fuse holder of reputed make in panels/boxes for AC/DC/PT Circuits wherever required as directed by the field Engineer.2/5/10A 16Amps
Supply & fixing of ISI mark backlite HRC fuse holder of reputed make in panels/boxes for AC/DC/PT Circuits wherever required as directed by the field Engineer.2/5/10A - 32Amps
Supply & fixing of ISI mark backlite HRC fuse holder of reputed make in panels/boxes for AC/DC/PT Circuits wherever required as directed by the field Engineer.2/5/10A - 63Amps
Supply & fixing of ISI mark backlite HRC fuse without holder in panels/boxes for AC/DC/PT circuit wherever required as directed by the field Engineer. - 2/5/10Amps
Supply & fixing of ISI mark backlite HRC fuse without holder in panels/boxes for AC/DC/PT circuit wherever required as directed by the field Engineer. - 32Amps
Supply & fixing of ISI mark backlite HRC fuse without holder in panels/boxes for AC/DC/PT circuit wherever required as directed by the field Engineer. - 63Amps
Supply & fixing of ISI mark MCB(AC) in panel/Boxes of reputed make as directed by the field Engineer. Single Phase 16Amps
Supply & fixing of ISI mark MCB(AC) in panel/Boxes of reputed make as directed by the field Engineer. - Three Phase 32Amps
Supply & fixing of ISI mark MCB(AC) in panel/Boxes of reputed make as directed by the field Engineer. - Two Phase 32Amps
Supply and fixing of ISI mark 3 Phase 4 Pole 415 V changeover switch of reputed make as required and as directed by the field engineer. 63A
Supply and fixing of ISI mark 3 Phase 4 Pole 415 V changeover switch of reputed make as required and as directed by the field engineer. 200A
Supply and fixing of mounting channels/rails, suitable for CBTM5 terminal blocks & MCBs in panel/box and as required and directed by field engineer.
Supply and fixing of nut type CBTM5 terminal block in panel box as required and as directed by the field engineer
Supply and fixing of disconnecting type terminal block for CT circuits in panel box as required and directed by the field engineer
Providing cable gland of suitable size including removing insulation of cable and providing suitable holes as per field condition, wherever required & as directed by the Engineer- 19 mm
Providing cable gland of suitable size including removing insulation of cable and providing suitable holes as per field condition, wherever required & as directed by the Engineer- 25 mm
Providing cable gland of suitable size including removing insulation of cable and providing suitable holes as per field condition, wherever required & as directed by the Engineer- 28 mm
Providing cable gland of suitable size including removing insulation of cable and providing suitable holes as per field condition, wherever required & as directed by the Engineer- 32 mm
Termination of cable core end including cost of cable socket, lug, ferrules, strap etc., as per cable schedule and as directed by the field Engineer for the equipments – Breaker, CT, CVT, Isolator panels etc.,.
Supply & providing of 600mm mean dia 300mm height 36mm Thick cement coller for identification of earth electrode location including 1 primer coat & 2 coat of colour wash as directed by the field Engineer
Supply and fixing of flexible copper tape /rope for interlinking panel earthing and for any other purpose on any size including the cost of copper lugs at both end as directed by the field engineer
Fabrication and fixing of bellmouth providing jumper connection in the solid core / PT insulators including the cost of GI pipe & other consumables & as directed by the field Engineer.
Supply & providing of 2.5 Sq.mm multi stand / single core flexble finolex/Indo cable for panel wiring work/ for any other purpose as directed by the field Engineer.
Supply & erection of DC interlock box (FRP) (Bay marshalling box ) as per specification , and as directed by the Dept. Engineer at site.including cost of all labour lead, lift & ext.,complete at site.
Supply & erection of AC Junction box (FRP) as per specification ,and as directed by the Dept. Engineer at site.including cost of all labour lead, lift & ext.,complete at site.
Supply of 100mmX10mm Al.flat bars for fitting switch end clamps and where ever necessary and as directed by the Field Engineer
Supply & Erection of 230KV Isolators MOM Box as per standard specification for replacement of existing MOM boxes and alignment of 230 KV Isolators(Motor operated) with earth or without earth, and internal wiring. , providing man power for testing whenever required & as directed by the field Engineer(including tower isolator)(Under LC Condition)
Dismantling of existing 230KV Current transformers including jumpers & secontry wiring connection & ext., & released materials shifted to pocket store.(Under LC Condition)
Dismantling of existing 110KV Potential transformers , Current transformers including jumpers & secontry wiring connection & ext., & released materials shifted to pocket store.(Under LC Condition)
Dismantling of support/up right/under hang 230 KV insulators or disc insulator.(Under LC Condition)
Dismantling of support/up right/under hang 110 KV insulators or disc insulator.(Under LC Condition)
Dismantling of existing230KV twin Kundha conductor strung bus one span 2 x 3 = 6 conductors)including Disc insulators, hardwares & ext., & released materials shifted to pocket store. (Under LC Condition)
Dismantling of existing230KV Kundha conductor strung bus(single conductor ,one span 1 x 3 Conductors)including Disc insulators ,hardwares & ext., & released materials shifted to pocket store.(Under LC Condition)
Dismantling of existing 110KV Kundha conductor strung bus (Twin conductor ,one span 2 x 3 =6 conductors) including Disc insulators ,hardwares & ext., & released materials shifted to pocket store.(Under LC Condition)
Dismantling of existing, Aluminium bus bars, including end clamps & etc., for erection of new 75 mm Alu.bus bars.(Under LC Condition) & released materials shifted to pocket store.
Dismantling of existing, droppers & jumpers including end clamps & etc., for erection of new droppers & jumpers with zebra conductor.(Under LC Condition) & released materials shifted to pocket store.
Supply of Aluminium power connector -Tension fitting 6 Bolted type
Supply and providing of 3", Bus Seating block
Supply and providing of Corona bell for 3" Alu. Bus
Supply and providing of Suspension fitting for Zebra -
Supply and providing of Rubber mat 2M x 2M x 10mm
GST for bidders within TamilNadu
GST for bidders outside TamilNadu (IGST)
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
BOQ_182557.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .