Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.2 L+₹1.0 L (7.38%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹16.4 L+₹2.3 L (16.1%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹18.6 L+₹4.5 L (31.5%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹19.6 L+₹5.5 L (38.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹18.1 L
EMD Value
₹36,500
Closing Date
8 Dec 2020, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2020_MES_370232_2
GE/NRC/8778/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹36,500
Yes
15 Jan 2021
11 Nov 2020
14 Dec 2020
11 Nov 2020
8 Dec 2020
24 Nov 2020
Amount
Taking down old unserviceable MCB TPN of any make & supply and fix MCB TPN 415 Volts, 'C' series, breaking capacity 10 kA of rating 63 Amps including necessary cable lugs / glands required at site complete all as directed by Engr-in-Charge . Note :- The item is operated as per daily based job card and complaint slip from department.
Dismantling carefully the existing unserviceable LT / HT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Supply and stringing ACSR conductor for over head line securing on pole complete including binding wire ,jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed.
Stringing only old dismantled ACSR conductor for over head line securing on pole complete including binding wire , etc of any size all as specified and as directed.
S & F 1100 Volts grade 4 line composite phase separators, moulded & bolted type as per IS 1445 - 1997 make max well or Denson including taking down old unserviceable separator.
S & F 1100 Volts grade 5 line composite phase separators, moulded & bolted type as per IS 1445 - 1997 make max well or Denson including taking down old unserviceable separator
Dismantling of unserviceable insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
Re-fixing of old LT pin insulator obtained from item No 7 above.
Re-fixing of old LT shakel insulator obtained from item No. 7 above
S & F pin type insulator 100mm height and 65mm dia for 1100 Volts grade, porcelain White, Brown or Green including one GI spindle, two GI washer, one GI nut all as specified and directed by Engr-in-charge.
S & F LT shackle type insulator 90mm dia 75 mm height, including GI strip of Size 31 x 3 mm washers, 12 mm dia, Insulators nuts, bolts suitable for 1100 volts grade.
Taking down old jumper connection of 4 pole structure from line / AB / DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin / pipe sleeve all as specified and directed by Engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down old jumper connection of 2 pole structure from line / AB / DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin / pipe sleeve all as specified and directed by Engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down old jumper connection of disc cut point from line and re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin/pipe sleeve all as specified and directed by Engr-in-Charge. (ACSR conductor will be measure & paid separately)
Taking down of faulty LT underground cable of size upto 3.5 x 25 sqmm from trenches / pole / wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation / Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Taking down of faulty LT underground cable of size above 3.5 x 25 sqmm upto 240 sqmm from trenches / pole / wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation / Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Supply and joint cable jointing kit straight through joint epoxy type of size 10 sqmm 4 core to 16 sqmm 4 core all as specified and directed.
Supply and joint cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core all as specified and directed.
Supply and joint cable jointing kit straight through joint epoxy type of size 70/95 sqmm 3.5 all as specified and directed.
Supply and joint cable jointing kit straight through joint epoxy type of size 120 sqmm 3.5 to 150 sqmm 3.5 core all as specified and directed.
Dismantling of unserviceable stay assembly carefully including stay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site all as directed.
Stay assembly complete with accessories and stay rod 16 mm dia and 180 cm long, including ms galvanized stay plate 300 mm x 300 mm x6 mm and galvanized thimble complete all as specified and shown in electrical plate No 1 Note-(loop type insulator, stays clamps, excavation and earth work and concrete measured separately)
All as per Item No 22 here in before, but stay Rod 20 mm dia
Dismantling of unserviceable existing cross arms by means made from channels, angles, unserviceable FI clamps, nuts, bolts etc. from OH line and removing complete.
S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
S & F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 , suitable for 11000 volt ,400 Amps incl dismantling of old one all as specified.
Dismantling of existing unserviceable HT / LT pole of any size & type from its position carefully and removing from the site and necessary excavation and earth work in any soil / strata, demoltion of concrete, disconnection of conductor fom pole etc. complete all as directed.
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450 mm x 450 mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 9 mtr long 410 SP-31 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450 mm x 45 0mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 11 mtr long 410 SP-55 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Taking down unservisable underground cable, service wire from trenches, wall, floor etc upto 35 sqmm
Taking down unservisable underground cable from trenches, wall, floor etc above 35 upto 95 sqmm
Supply , laying and testing XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade lay in trenches , ducts , along pole, along transformer cross sectional area 3 core 95 sqmm complete all as specified and directed.
EXCAVATION BY TENCHLESS TECH - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. Suitable for 0.4 mpa working pressure.
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (9.0 mtr length) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge
S& F XLPE insulated armoured and PVC sheated heavy duty electric cable of size 2 core 10 sqmm aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in trenches passing through pipes / ducts including testing complete
All as per item No 38 here in before but, of size 4 core 16 sqmm
All as per item No 38 here in before but, of size 3.5 core 50 sqmm
All as per item No 38 here in before but, of size 3.5 core 95 sqmm
All as per item No 38 here in before but, of size 3.5 core 150 sqmm
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out.
Taking down old unserviceable metal box and supply and fixing MS enclosure made out of CRCA sheet 3.00 mm thick of size 450 mm x 450 mm x 250 mm depth with aluminium bus bar mounted on epoxy insulators, fixing arrangement with suitable MS clamps.
Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf / cm2 laid in trenches of size 50 mm suitable for cable protection of size 50 sqmm complete all as specified and directed.
Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf / cm2 laid in trenches of size 95 mm suitable for cable protection of size upto 95 sqmm to 150 sqmm HT / LT cable complete all as specified and directed.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25cm all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point all as specified and directed.
Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole as specified by Engr-in-charge.
Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
M&L Earthing with 600 X 600 X 6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32 X 6 mm by means of bolts, nuts, check nuts, and washer of galvanised steel, Gi shrip to be provide upto the extent of 7.5 m GI strip to be duly connected to metalic bodies of HT / LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement, complete all as shown on electrical plate No.3 of SSR Part I (2009) and testing on completion.
M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00 mm dia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6 mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00 mm dia up to 7.5 m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-1991 (part-I)
S&F PVC junction box of size inside dimenssion 250 x 200 x 105 mm complete with industrial connector, including clamp made out of MS flat iron 30 x 5 mm , connection from junction box to street light fitting as specified & directed
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (11.0 mtr length- Two pole structure) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint / steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge
M&L for scrapping the existing deterioted old alumininum paint by iron brushing and painting of steel tubular poles of (11.0 mtr length- four pole structure) with one coat of metal primer and two coat of aluminium paint over exposed portion of pole above PCC coping including cross arms, angles, nut, bolts, clamps and S&F new radium sticker Radium paint / sticker of different colour 80 cm above coping of pole, i.e. alernatively with sky blue / red & white radium sticker (10 cm - 04 sky blue / red strip and 10 cm - 04 white strip) complete circumference of any type any shape pole and cement base paint on coping portion, marking of pole nos with radium yello / black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed at site.complete all as specified and directed at site by Engineer-in-Charge
Dismantling and taking down by disconnecting electric connection from existing serviceable / unserviceable / partly unserviceable street / security / flood light fittings or any other light fitting of any type / any wall, fitting and fixture etc and depositing to MES store yard or serviceable light fitting will be reuse in other loction and making good to the disturbed surfaces etc complete all as specified and directed at site.
Fixing only security light fitting of any size any watt and any location complete all as specified and directed by Engr-in-Charge. PVC insulated cable from junction box to street light or overhead line to fitting shall be measured under relevant item. Note : Security lights shall be issued to contractor under Sch 'B' free for fixing only )
Material and labour for painting / Repairing with welding including change of hinges of LT pannel board / LT feeder piller box, indoor / out door type any size / capacitywith smoke gray colour synthetic enamel paint one coat over the existing paint after cleaning and removing the dust and durt and cleaning with sand paper complete including writting letters 100 mm height with white synthetic enamelled paint complete with PCC work all as specified and directed at site.
Supply and fix galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
Supply & fix PVC insulated 3 core 1.5 sqmm multistranded Copper conductor on pole for security light from junction box to street light fititng as specified and directed.
Taking down old burnt / unserviceable MCCB and S&F MCCB 100 Amps TP, 415 V with thermal magnetic setting 18/16 KA capacity , fixing to suit in repair with fixing arrangement in the existing LT panel board complete
Taking down old burnt / unserviceable MCCB and S&F MCCB 160 Amps TP, 415 V with thermal magnetic setting 18 / 16 KA capacity , fixing to suit in repair with fixing arrangement in the existing LT panel board complete
Taking down old burnt / unserviceable MCCB and S&F MCCB 200 Amps TP, 415 V with thermal magnetic setting 18 / 16 KA capacity , fixing to suit in repair with fixing arrangement in the existing LT panel board complete
Supply only service cable 2 core aluminium conductor PVC insulatd PVC sheathed cross sectional area 4 sqmm 1100 volts grade .
Supply only service cable 2 core aluminium conductor PVC insulatd PVC sheathed cross sectional area 6 sqmm 1100 volts grade .
Supply only service cable 2 core aluminium conductor PVC insulatd PVC sheathed cross sectional area 10 sqmm 1100 volts grade .
NOTE :- AMOUNT OF SCHEDULE OF CREDIT RS. 25,680.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
DURGAI ELECTRICALS
M/S S.N ENTERPRISES
SHRI SULAI ELECTRICALS
M/s Anil Builders
Bidder Name
SHRI SULAI ELECTRICALS
DURGAI ELECTRICALS
SHRI SWAPNAYOG ENTERPRISES
M/S S.N ENTERPRISES
M/s Anil Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .