Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹18.8 LAdmitted-Finance | +4.37% | ₹18.8 L | L1 | Admitted-Finance |
| 2 | L2₹19.2 L+₹43,773.60 (2.33%)Admitted-Finance E76 LGF KALKAJI BHAIRAV MANDIR NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | +6.80% | ₹19.2 L+₹43,773.60 (2.33%) | L2 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹36,028
Closing Date
2 Jul 2026, 4:00 pmClosed
Er. Balbir Singh, Executive Engineer (E)BM-I
3rd Floor Mohan Singh Place BKS Marg Connaught Place New Delhi
As per NIT
2026_NDMC_294302_1
NIT No. 18/EE(BM-I)E/2026-27
Open Tender
Electrical Works
Works
365 days
at Talkatora Indoor Stadium New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹36,028
10 Jul 2026
24 Jun 2026
2 Jul 2026
24 Jun 2026
2 Jul 2026
24 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | COMPREHENSIVE AMC OF HVAC SYSTEM (Lower Side) INSTALLED AT TIS WITH THE FOLLOWING SPECIFICATIONS:
Primary Chilled Water Pumps – 10 HP each (Make Kirloskar) – 05 Nos.
Secondary Chilled Water Pumps (VFD control) – 40 HP (Make Armstrong) – 04 Nos.
Condenser Water Pumps – 30 HP (Make Kirloskar) – 05 Nos.
FRP induced draft Cooling Tower – 325 TR/10 HP each (Make Bell) – 04 Nos.
AHU motors – 20 HP/25000 CFM each. (Make ABB) – 06 Nos.
AHU – 7.5 KW/20500 CFM (Make ABB) – 02 Nos.
AHU – 5.5 KW/12000 CFM (Make ABB) – 08 Nos.
AHU motors – 5 HP/5500 CFM each. – 04 Nos.
AHU motors – 3 HP/5000 CFM each. – 02 Nos.
AHU motors – 2 HP/3400 CFM each. – 02 Nos
AHU – 2.2 KW/5000 CFM (Make ABB) – 06 Nos.
AHU – 2.2 KW/6000 CFM (Make ABB) – 02 Nos.
Ceiling Suspended AHU – 2.2 KW/5000 CFM – 01 No.
AHU motors – 1 HP/1900 CFM each. – 07 Nos.
FCU – 400W/2 TR each. – 04 Nos.
FCU – 400W/1.5 TR each. – 16 Nos.
TFA – 1.5 HP/1500 CFM – 04 Nos.
Air washer – 25 HP/32000 CFM each. (Make Humidian) – 02 Nos.
Smoke Evacuation Fan – 5.24 KW/22000 CFM. (Make Nicotra) – 06 Nos.
Smoke Evacuation Fan – 2.2 KW/5000 CFM – 08 Nos.
Smoke Evacuation Fan – 2.2 KW/7000 CFM – 02 Nos.
Exhaust Fan – 10000 CFM – 02 Nos.
Centrifugal Fans Fan – 15 KW/40000 CFM – 08 Nos.
Centrifugal Fans Fan – 15 KW/36000 CFM – 08 Nos.
Fresh Air Fan for basement triangular building area – 11000 CFM – 02 Nos.
Fresh Air Fan for basement parking area -7.5 HP/11000 CFM – 02 Nos.
and included other equipment which is left but part of Air conditioning & Mechanical Ventilation system etc. | 1 | Job | 18,01,383 | ₹18,01,383 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.16 MB
BOQ_391262.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .