Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.8 L+₹2.6 L (9.80%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹29.7 L+₹3.4 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹30.5 L+₹4.2 L (16.1%)Rejected-Finance | L4 | Rejected-Finance Highest bid quoted other then L1 | |
| 5 | L5₹33.8 L+₹7.5 L (28.7%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L5 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹77,180
Closing Date
29 Aug 2022, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
SPL REPAIR TO LT PANEL AND CONVERSION OF OH TO UG LT CABLE WITH ALLIED WORK AT 516 ASC BN AT SRI GANGANAGAR MIL STATION
2022_MES_542559_1
GE SGNR/ TOK-30 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Sri Ganganagar
D Class b(i) for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹77,180
Yes
6 Oct 2022
2 Aug 2022
31 Aug 2022
2 Aug 2022
29 Aug 2022
8 Aug 2022
Amount
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 150 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 120 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 50 sq mm. 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 25 sq mm. 4core complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 16 sq mm. 4core complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 10 sq mm. 4core complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 10 sq mm. 2core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry coarse sand to under ground cable around the cable after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supplying, erecting in true vertical position in replacement of 9 meter long ,type 410 SP- 31 steel tubular swan Necked pole complete with cast iron base plate, finial taper plug, bolts nuts and screws including painting with two coat of synthetic enamel paint black and white in alternate strips 30cm each up to 1.5 meter height from top of PCC coping and remaining portion of pole shall be painted with two coats of aluminum paint including writing pole No. with black synthetic enamel paint over 15 cm dia. yellow round base prepared with synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.NOTE: - Excavation, earth work and concrete work for embedding poles shall be measured and paid separately.
Supply and fixing new generation energy saving & environmental friendly long life versatile pressure die-cast aluminum IP-66 road way luminaries 45 watt LED with high power LEDs as light source and electronic driver including testing complete all as specified and directed by Engineer-in-Charge
Supply, install, test and commisioning of LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed with bottom frame made out of angle iron 50mm x 50mm x 6mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 200 Amps from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected iems complete all as specified and directed by Engineer-in-Charge. FP No1 Incoming (i) MCCB 200 Amps, four pole with fixed thermal magnetic release, 415 V AC supply, having rupturing capacity 36 KA - 01 No Outgoing (ii) MCCB 100 Amps, Four pole with fixed thermal magnetic release, 415 volts having rupturing capacity 25 KA - 3Nos (iii) 32 Amp TPN - 01 Nos (iv) 25 Amp SPN - 02 Nos(v) Indicating lamps set RYB - 01 Set (VI) Digital Amp Meter 0- 250 A with CT , Digital Voltmeter 0- 500 V
Supply, install, test and commisioning of LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed with bottom frame made out of angle iron 50mm x 50mm x 6mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 200 Amps from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incomingproper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories& all connected items complete . Incomming (i) MCCB 100 Amps, four pole with fixed thermal magnetic release, 415 V AC supply, having rupturing capacity 25 KA -01 No Out going (ii) MCCB ,4 pole 63 Amp -02 No (ii) TPN 32 Amp -02 No (iii) SPN 25 Amp -02 Nos (iv) Indicating lamps set RYB - 01 Set (v) Digital Amp Meter 0- 200 A with CT , Digital Voltmeter 0- 500 V
Supply and fix shock ,rust proof fire retarddant class FV-0 as per IS-11731 Part II or V-0 as per UL -94 ,high heat distortion temperature FRP juction box of size 300 x200x105 mm with locking arrangement made out of 3 mm thick PVC sheet including provision of 4 nos aluminium busbar of size20 mmx3 mm mounted on insulator 01 nos MCB 1 A SP 10 KA 240 volt , drilling holes for outgoing and incomming cable ( 2 way) connection with suitable lugs and glands including provision of clamp made out of 40 x5 mm thick mild steel flat iron complete all as specified and directed by Engineer-in-Charge.
M&L for GI 1.2 meter bracket for street lightincluding nut bots , fabricated fromstructural steel sections incl nut,bolts, ,washers, welding, ,bending cold or hot , drilling holes for bolts , in any sizecomplete all as specified and directed by Engineer-in-Charge.
Painting on steel tubular poles of any size with MS Clamps and with two coat of superior quality of aluminium paint incl preparation of surface by rubbing complete incl painting of steel poles with synthetic enamel paint each of 30 cm width upto 1.5 mtr height from Gl amd making of pole numbers serially with painting 150mm circle with yellow paint and writing ST-01and so on with black paint complete all as specified and directed by Engineer-in Charge.
S&F on pole/wall/in panel, Sheet metal enclosure Bus bar chamber consisting 04 pole 200 Amp 415 volts copper bus bar Each Set suitable for connecting cable as a (junction incoming & outgoing total No 4 ways) including connecting of existing cables with suitable sizes aluminum thimbles complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 32 x 6 mm size by means of bolts, nuts check nuts and washers of galvanised iron and 32 x 6 mm dearth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.5 of SSR1991 Part I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4.0 mm size by means of bolts, nuts check nuts and washers earth lead protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) , GI light grade 20mm bore pipe for watering perforated at the bottom 7.5 meter long placed on top edge of earth plate common salt and charcoal filling test point , funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR1991 Part I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for boring of holes 80 mm under road/pavement/hard standing or any other situation by manual mean and making good both the ends complete all as specified and directed by Engineer-in-Charge. . Note : Pipe and cable will be measured and paid separately
Supply and fix in replacement of GI pipe 80 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
M & L in replacement PVC insulated, PVC sheathed Aluminium conductor electric cable 1.5 Sq mm 3Core 1100 volts grade for pole box to street light fitting complete all as specified and directed by Engineer-in-Charge.
Dismanting of unserviceable ACSR conductor/AAC conductor of any size and any type complete all as specified and directed by Engineer-in-Charge.
Dismanting of steel pole any type and size complete all as specified and directed by Engineer-in-Charge.
Dismanting of cross arm, clamps , bracing etc of MS section complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and directed by Engineer-in-charge
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in pedestal coping of poles etc including weathering, slightly rounded or chamfered angle and necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
Dismanting of insulator complete all as specified and directed by Engineer-in-Charge.
Note :(i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
Singla Electricals
Ganganagar Enterprises
DASHMESH ENTERPRISES
M/S BUDHRAM BISHNOI
Aggarwal brothers and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .