Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.5 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹43.5 L+₹90,842 (2.13%)Rejected-Finance | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | Rejected-Technical 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | - | Rejected-Technical Due to non enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
13 Mar 2021, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
OUTSOURCING OF SERVICES FOR OPERATION AND MAINTENANCE OF 132/11KV MRS EXTRA HIGH VOLTAGE WITH 50KVA DG SET AND CONNECTED EQUIPMENTS AT MRS AND EARTHING SYSTEM UNDER GEI RND RCI HYDERABAD
2021_MES_415892_1
8604
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE I R AND D RCI
MES enlisted Class D category b iii and d v Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹98,000
Yes
31 Aug 2021
25 Jan 2021
22 Mar 2021
25 Jan 2021
13 Mar 2021
27 Feb 2021
Amount
Outsourcing of services for operation and maintenance of 132/11KV Main Step Down Station, 50KVA DG Set and Distribution of HT networking system for trouble free operation of entire installation including 132/11KV Switch Yard (Old & New) for daily checking as given in Appendix 'A' etc., complete by providing One Electrician and One Helper per shift of 8 hours for Three shifts in a day on all days including Sundays and all Holidays complete all as specified and directed.
Maximum Demand and Power Factor shall be monitored every 4hours.
Providing stationery, aprons, safety equipments, tools, testing equipment, maintaining all records, log sheets, cleanliness and up keeping yard and surroundings of MSDS shall be the responsibility of contractor and this provision shall be deemed to be included in the unit rate quoted.
Local and remote operation shall always be operational and any defect shall be rectified immediately.
It shall be the responsibility of the contractor for maintenance during break down from MSDS to down below sub station like establishing outgoing cable faults by disconnecting and meggering to the cable for opening the panels for checking the faults, isolation of the fault and restoration of power supply etc., However jointing of cables and repairs of the panels are not included in the scope of work.
All as per item No 01 above by providing One Highly Skilled Electrician per shift of 8 hours for Three shifts in a day on all days including Sundays and Holidays.
Outsourcing of services for maintenance of Voltage Stabilizers, Isolation Transformers, Main Incoming Panels of individual buildings and Air Conditioning Installation incoming panels by attending and rectifying fault/ breakdown in the system, servicing and decarbonising of LT panels for avoidance of short circuits/faults of complete RCI area including ELSEC, CPDC by providing Two Electricians and One Helper per shift of 8 hours for One shift in a day on all days excluding Sundays and Holidays.
Notes for the serial item No 01 to 03: Diesel will be issued by the department free for running the DG set and the contractor shall maintain the daily log sheet duly signed by the users at each substation.
Contractor shall maintain daily log sheet duly signed at each Sub Station all as directed by the Engineer in Charge.
All T&P including Hydraulic ladder or aerial access platform mounted on vehicle required for operating, repair and maintenance are deemed to be included in the unit rates quoted.
All stationary for Duty Roster, Attendance register, Wages register, Log sheet book, maintenance record etc., shall be arranged, maintained and submitted by the contractor to Engineer in charge in the first week of every month.
Any loss due to negligence, faulty operation shall be made good by the contractor without any extra cost to the department.
Wage period shall not exceed one month. Wages for all workers employed shall be paid before 7th day of every month through bank account without fail irrespective of whether RAR is claimed or not.
Minimum wages, EPF, ESI, Bonus etc., to the workers shall be paid by the contractor as per Regional Labour/PF Commissioner Gazette Notification including DA all as authorized.
Labour elements for fixing of spares/parts mentioned in this schedule as supply only shall be deemed to include in the unit rate quoted.
The workers employed by the contractor for outsourcing shall be entitled for one day weekly off and the contractor has to provide suitable substitute in the concerned shifts. The unit rate quoted shall be deemed to include for this provision.
Personal protective equipment and tools such as gloves, safety shoes, torch, earthing discharging rods and spanner set shall be provided by the contractor for the persons engaged in the work. Quoted rate shall be deemed to include cost of same. Market cost towards cost of the equipment shall be recovered from any amount due to contractor for non compliance of the above provision.
M&L in repairs, Earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to GI strip 32x6mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed.
Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II.
2. GI earth Strip beyond 7.5m will be measured and paid separately.
M&L in repairs, Earthing complete with copper earth plate electrode of size 600 x 600 x 3mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to copper strip 20x3mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed.
Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 25mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II.
2. Copper earth strip beyond 7.5m will be measured and paid separately.
Supply only GI earth strip 50 x 6mm as in earth continuity conductor or main earthing lead complete all as specified.
Supply only GI earth strip 32 x 6mm as in earth continuity conductor or main earthing lead complete all as specified.
Supply only copper earth strip 32 x 6mm as in earth continuity conductor or main earthing lead complete all as specified.
Supply only copper earth strip 20 x 3mm as in earth continuity conductor or main earthing lead complete all as specified.
Supply only aluminium earth strip 25 x 3mm as in earth continuity conductor or main earthing lead complete all as specified.
Supply only commercial salt crystal type.
Supply only funnel made of GI sheet for earthing.
Supply only ready made, 40mm thick precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate earth pit cover slab all as shown on Electrical Plate No. 3 of SSR Part-I, reinforced with 8mm dia TMT bars at 150mm centre to centre both ways.
Supply only breather of 5Kg capacity along with silica gel for power transformer of 8MVA capacity complete all as specified.
Supply only HT 11KV bus support insulator complete all as specified.
Supply only HT 11 KV Fuse Wire
Supply only 110 DC trip coil for 11 KV VCB
Supply only 110 DC closing coil for 11 KV VCB
Supply only 110 DC trip neutral close switch for breaker control.
Supply only strip heater 80Watt for 11 KV VCB
Supply only DOL starter suitable for 3 phase 2HP OLTC mechanism motor, 1.5KW and relay max range of 10.5-17.5Amp complete all as specified.
Indu Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .