Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAccepted-AOC | ₹4.7 Cr | L1 | Accepted-AOC reasonable bid |
| 2 | L2₹5.0 Cr+₹33.9 L (7.23%)Rejected-AOC BU 02 SFS FLATS OUTER RING ROAD PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹5.0 Cr+₹33.9 L (7.23%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹5.3 Cr+₹62.4 L (13.3%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | ₹5.3 Cr+₹62.4 L (13.3%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹5.7 Cr+₹98.5 L (21.0%)Rejected-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹5.7 Cr+₹98.5 L (21.0%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹5.7 Cr+₹1.0 Cr (21.8%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹5.7 Cr+₹1.0 Cr (21.8%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹5.0 Cr
EMD Value
₹5.7 L
Closing Date
18 Oct 2021, 6:00 pmClosed
CE R N D Secunderabad
CE R N D Opp Jubilee Bus Station Picket Secunderabad
PROVISION OF AIRCONDITIOING TO TECHNICAL BUILDING AT RCI HYDERABAD
2021_MES_473833_1
CA NO.CERD/SEC/TOKEN/44 OF 2018 -2019
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
As per NIT
7 documents required · 7 mandatory
₹2,000
Yes
GE I R and D RCI Hyderabad
₹5.7 L
Yes
2 Dec 2021
8 Sept 2021
25 Oct 2021
8 Sept 2021
18 Oct 2021
11 Oct 2021
Amount
SCHEDULE 'A' PART - I Supply, installation, testing and commissioniong of Air-cooled Screw type chilling units 3x89TR (02 working + 01 standby), AHRI certified not less than 89 TR actual capacity each at below mentioned design conditions, complete with semi hermetic twin screw single/multi compressor/s, Flooded type shell and tube type chiller, with in-built DOL / star delta starter, electronic expansion valve, motor, air-cooled condensers (Cu tubes and Al fins type only) and fans with high air flow with Hydrophobic fins coating, spring vibration isolators, integrated refrigerant piping, fitting and valves and wiring, operating on Eco-friendly CFC & HCFC Refrigerant such as R134a / 407c etc., first charge of factory filled refrigerant and lubricant, micro processor based control panel, automatic and safety controls all mounted on steel frame as per manufacturers specifications. complete all as specified an directed. (For Non Explosive building). Chilled Water in - 12 deg.C (53.6 deg.F) Chilled Water out - 7 deg.C ( 44.6 deg.F) Ambeint Temp - 45 deg C (113 deg F) Fouling Factor for chiller - 0.0001 FPS units COP @ AHRI conditions shall be more than 3 IPLV @ AHRI conditions shall be more than 4.0 1 KW/TR at design conditions shall not exceed 1.58 KW/TR MAKE:- Blue Star / Trane / Daikin / Voltas Notes:- (i) The chiller performance test report on AHRI condition shall be submitted before dispatch / approval (ii) All necessary civil works for foundation etc., deemed to be included in unit rate quoted all as per manufacturer's instructions/specifications.
Supply, installation,testing and commissioniong of Air-cooled Screw type chilling units 3x75TR (02 working + 01 standby), AHRI certified not less than 75 TR actual capacity each at below mentioned design conditions, complete with semi hermetic twin screw single/multi compressor/s, Flooded type shell and tube type chiller, with in-built DOL / star delta starter, electronic expansion valve, motor, air-cooled condensers (Cu tubes and Al fins type only) and fans with high air flow with Hydrophobic fins coating, spring vibration isolators, integrated refrigerant piping, fitting and valves and wiring, operating on Eco-friendly CFC & HCFC Refrigerant such as R134a / 407c etc., first charge of factory filled refrigerant and lubricant, micro processor based control panel, automatic and safety controls all mounted on steel frame as per manufacturers specification, complete all as specified and directed. (For Explosive Building) Chilled Water in - 12 deg.C (53.6 deg.F) Chilled Water out - 7 deg.C ( 44.6 deg.F) Ambeint Temp - 45 deg C (113 deg F) Fouling Factor for chiller - 0.0001 FPS units COP @ AHRI conditions shall be more than 3 IPLV @ AHRI conditions shall be more than 4.0 1 KW/TR at design conditions shall not exceed 1.58 KW/TR MAKE:- Blue Star / Trane / Daikin / Voltas Notes:- (i) The chiller performance test report on AHRI condition shall be submitted before dispatch / approval (ii) All necessary civil works for foundation etc., deemed to be included in unit rate quoted all as per manufacturer's instructions/specifications.
Supply, install, testing and commissioning of EES series (Energy Efficient) mono block centrifugal water pumpset of standard IEC 60034-30:2008 and IS 12615:2011, end suction, top discharge comprising of pump of capacity to circulate 384 USGPM (US Gallon per minute) at not less than 40 metre head, fitted with suitable electric motor copper wound on same base frame (TEFC and IP-55) for chilled water pumping including mechanical seal, base frame anti vibration pads, necessary accessories, civil works for foundation of pump sets etc., complete all as specifed and directed. (For chilled water of Explosive building) (one working and one stand by) MAKE:- KIRLOSKAR / KSB / CROMPTON GREAVES / GRUNDFOSS
Supply, install, testing and commissioning of EES series (Energy Efficient) mono block centrifugal water pumpset of standard IEX 60034-30:2008 and IS-12615-2011, end suction, top discharge comprising of pump of capacity to circulate 450 USGPM (US Gallon per minute) at not less than 40 metre head, fitted with suitable electric motor copper wound on same base frame (TEFC and IP-55) for chilled water pumping including mechanical seal, base frame anti vibration pads, necessary accessories, civil works for foundation of pump sets etc., complete all as specifed and directed. (For chilled water of Non-Explosive building) (one working and one stand by) MAKE:- KIRLOSKAR / KSB / CROMPTON GREAVES / GRUNDFOSS
Chilled water tank, HDPE, of capacity 1000 litre, tank shall be insulated with fiber glass wool of density 24 kg/cu.m and thickness 50mm and covered with chicken wire mesh and covered with sand cement plaster complete, with and including provision of suitable size float valve, over flow and drain pipe arranegement, inlet and outlet GI pipe 25mm dia medium grade with valves from tank to tapping point and including provision of painting to the external surface, complete all as specified and directed. (01 for Explosive and 01 for Non-Explosive AC plant). NOTE:- Provision of new foundation in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) including making good disturbed surfaces to match with the existing shall deemed to be included in the quoted rate.
Hot water tank, HDPE, of capacity 500 litre, tank shall be insulated with fiber glass wool of density 24 kg/cu.m and thickness 50mm and covered with chicken wire mesh and covered with sand cement plaseter complete, with and including provision of suitable size float valve, over flow and drain pipe arranegement, inlet and outlet GI pipe 25mm dia medium grade with valves from tank to tapping point and including provision of painting to the external surface, complete all as specified and directed. (01 for Explosive area). NOTE:- Provision of new foundation in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) including making good disturbed surfaces to match with the existing shall deemed to be included in the quoted rate.
Supply, install, testing and commissioning of capacity 29,000 CFM, Total Static pressure 80mm water gauge, floor mounted double skin construction Air Handling Unit (AHU), recirculation type made of extruded aluminium structural frame work and casted polyemide / aluminium corner / intermediate connecting pieces, panels made of 45mm / 40kg per cu.m PUF injected sandwich panels in 0.6mm thick galvanised sheet casings having scratch free plastisol coating on galvanised sheet on external side with 6 row chilled water coil of capcity not less than 45TR, two row hot water circulating coil of suitable size and capacity including mixing chamber and flame proof motor, complete all as specifed and directed. The Air handling unit (AHU) shall comprise of fan section with DIDW backward curved fan, fitted with suitable electric motor copper wound (TEFC and IP 55) and motor drive assembly coil section comprising of chilled water 6 row copper coil, stainless steel drain pan covered under coil section and fan section with proper U-trap made up of SS 304 grade, 1.00mm thick sheet including GI pipe suitable for drain, filter section comprising of pre-filters capable of filtering upto 10 microns at 90% efficiency followed by 5 micron filter, fire retardant canvas connection, VCD, anti vibration springs for drive set and anti vibration pads / footings for mounting AHU beneath auxiliary base frame, provision of inspection doors with locking facility. (For Explosive building Rudram II) MAKE:- ZECO / EDGETECH / CITIZEN / VOLTAS / BLUESTAR
Supply, install, testing and commissioning of capacity 18,000 CFM, Total Static pressure 80mm water gauge, floor mounted double skin construction Air Handling Unit (AHU), recirculation type made of extruded aluminium structural frame work and casted polyemide / aluminium corner / intermediate connecting pieces, panels made of 45mm / 40kg per cu.m PUF injected sandwich panels in 0.6mm thick galvanised sheet casings having scratch free plastisol coating on galvanised sheet on external side with 6 row chilled water coil of capcity not less than 35TR, two row hot water circulating coil of suitable size and capacity including mixing chamber and flame proof motor, complete all as specifed and directed. The Air handling unit (AHU) shall comprise of fan section with DIDW backward curved fan, fitted with suitable electric motor copper wound (TEFC and IP 55) and motor drive assembly coil section comprising of chilled water 6 row copper coil, stainless steel drain pan covered under coil section and fan section with proper U-trap made up of SS 304 grade, 1.00mm thick sheet including GI pipe suitable for drain, filter section comprising of pre-filters capable of filtering upto 10 microns at 90% efficiency followed by 5 micron filter, fire retardant canvas connection, VCD, anti vibration springs for drive set and anti vibration pads / footings for mounting AHU beneath auxiliary base frame, provision of inspection doors with locking facility. (For Explosive building Pralay) MAKE:- ZECO / EDGETECH / CITIZEN / VOLTAS / BLUESTAR Note:- Necessary civil works for foundation of AHU, deemed to be included in unit rate quoted all as per manufacturer's instructions/specifications.
Supply, install, testing and commissioning of capacity 24,000 CFM, Total Static pressure 80mm water gauge, floor mounted double skin construction Air Handling Unit (AHU), recirculation type made of extruded aluminium structural frame work and casted polyemide / aluminium corner / intermediate connecting pieces, panels made of 45mm / 40kg per cu.m PUF injected sandwich panels in 0.6mm thick galvanised sheet casings having scratch free plastisol coating on galvanised sheet on external side with 6 row chilled water coil of capcity not less than 45TR, hot water circulating coil of suitable size and capacity including mixing chamber and flame proof motor, complete all as specifed and directed. The Air handling unit (AHU) shall comprise of fan section with DIDW backward curved fan, fitted with suitable electric motor copper wound (TEFC and IP 55) and motor drive assembly coil section comprising of chilled water 6 row copper coil, two row hot water coil, stainless steel drain pan covered under coil section and fan section with proper U-trap made up of SS 304 grade, 1.00mm thick sheet including GI pipe suitable for drain, filter section comprising of pre-filters capable of filtering upto 10 microns at 90% efficiency followed by 5 micron filter, fire retardant canvas connection, VCD, anti vibration springs for drive set and anti vibration pads / footings for mounting AHU beneath auxiliary base frame, provision of inspection doors with locking facility. (For Explosive building Rudram III) MAKE:- ZECO / EDGETECH / CITIZEN / VOLTAS / BLUESTAR Note:- Necessary civil works for foundation of AHU, deemed to be included in unit rate quoted all as per manufacturer's instructions/specifications.
Supply, install, testing and commissioning of capacity 18,000 CFM, Total Static pressure 80mm water gauge, floor mounted double skin construction Air Handling Unit (AHU), recirculation type made of extruded aluminium structural frame work and casted polyemide / aluminium corner / intermediate connecting pieces, panels made of 45mm / 40kg per cu.m PUF injected sandwich panels in 0.6mm thick galvanised sheet casings having scratch free plastisol coating on galvanised sheet on external side with 6 row chilled water coil of capcity not less than 35TR, including electric control panel, complete all as specifed and directed. The Air handling unit (AHU) shall comprise of fan section with DIDW backward curved fan, fitted with suitable electric motor copper wound (TEFC and IP 55) and motor drive assembly coil section comprising of chilled water 6 row copper coil, stainless steel drain pan covered under coil section and fan section with proper U-trap made up of SS 304 grade, 1.00mm thick sheet including GI pipe suitable for drain, filter section comprising of pre-filters capable of filtering upto 10 microns at 90% efficiency followed by 5 micron filter, fire retardant canvas connection, VCD, anti vibration springs for drive set and anti vibration pads / footings for mounting AHU beneath auxiliary base frame, provision of inspection doors with locking facility. (For Non-Explosive Pralay) MAKE:- ZECO / EDGETECH / CITIZEN / VOLTAS / BLUESTAR Note:- Necessary civil works for foundation of AHU, deemed to be included in unit rate quoted all as per manufacturer's instructions/specifications.
Supply, install, testing and commissioning of capacity 30,000 CFM, Total Static pressure 80mm water gauge, floor mounted double skin construction Air Handling Unit (AHU), recirculation type made of extruded aluminium structural frame work and casted polyemide / aluminium corner / intermediate connecting pieces, panels made of 45mm / 40kg per cu.m PUF injected sandwich panels in 0.6mm thick galvanised sheet casings having scratch free plastisol coating on galvanised sheet on external side with 6 row chilled water coil of capcity not less than 50TR, incluidng electrcial control panel, complete all as specifed and directed. The Air handling unit (AHU) shall comprise of fan section with DIDW backward curved fan, fitted with suitable electric motor copper wound (TEFC and IP 55) and motor drive assembly coil section comprising of chilled water 6 row copper coil, stainless steel drain pan covered under coil section and fan section with proper U-trap made up of SS 304 grade, 1.00mm thick sheet including GI pipe suitable for drain, filter section comprising of pre-filters capable of filtering upto 10 microns at 90% efficiency followed by 5 micron filter, fire retardant canvas connection, VCD, anti vibration springs for drive set and anti vibration pads / footings for mounting AHU beneath auxiliary base frame, provision of inspection doors with locking facility. (For Rudram II and Rudram III) MAKE:- ZECO / EDGETECH / CITIZEN / VOLTAS / BLUESTAR Note:- Necessary civil works for foundation of AHU, deemed to be included in unit rate quoted all as per manufacturer's instructions/specifications.
Supply, install, testing and commissioning Hot Water generation system comprising of 3-phase Pumps - 02 Nos (1 working + 1 standby) (like base frame, coupling, lubricating seal, motor etc.,), with and including provision of MS structure required for the installation of pumps, suitable RCC foundation as per manufacturers specification, complete as per manufacturers drawing, suitable for 100KW hot water generator; the pumps shall have to work for a total minimum head of 30metre for flow rate 17200 litre per hour, complete all as specifed and directed. Hot water Generator, 100KW capacity, with all accessories; vertical / horizontal vessel of Hot Water Generator shall be made out of good quality mild steel conforming to IS-226 standard design, temperature and pressure; Hot Water Generator shall be provided with 2 to 4 Banks, equally distributed load, factory wired, complete all as per manufacturers specification and as per manufacturers drawing, with and including provision of Hot water piping of 40 / 32mm MS 'C' Class pipe ERW conforming to IS:3589 duly insulated with mineral / rock wool / glass wool of density not less than 48 kg/cu.m with thickness 50mm covered around pipe line and shall be covered with 26 guage aluminum cladding with nuts and bolts / screws, complete all as specified and directed. MAKE:- RAPID COOL / EMERALD / KEPL Notes :- (i) Pumps, Hot water generator, associated pipe work with thermal insulation and all other associated work shall deemed to be included in the quoted rate. (ii) Necessary civil works for foundation of AHU, deemed to be included in unit rate quoted all as per manufacturer's instructions/specifications.
Pan type humidifier with 6 KW including inter-connecting 25mm GI pipe with 100 litre capcity make up tank, complete all as specified and directed. MAKE:- RAPID CONTROL / THERMAX / ECOFLAME / EMERALD / M/s DASPASS SALES CORPORATION, DELHI
Ultrasonic humidifer with 5 LPH flow rate, including inter-connecting 25mm GI pipe with 100 litre capcity make up tank, complete all as specified and directed. MAKE:- RAPID CONTROL / THERMAX / ECOFLAME / EMERALD / M/s DASPASS SALES CORPORATION, DELHI
Humidistat and Digital thermostat including control wiring, complete all as specified and directed. MAKE:- DANFOSS / JOHNSON / HONEYWELL / SIEMENS / SCHNEIDER / BELIMO / RAPID CONTROL
Fin type strip heater bank 20 KW capacity with control panel fixing in side, the duct fixed on insulators for each AHU, complete all as specified and directed. MAKE:- DASPASS / ESCORT
Supply, erection, testing and commisioning of mild steel class 'C', ERW pipes, laid above ground / underground as per site requirement, conforming to IS: 3589 to be used as insulated chilled water piping complete with fittings, flanges, gaskets, fasteners, cement / mild steel supports wherever necessary, pressure testing of pipes including insulation of piping with 50mm thick TF quality EPS pipe section, covering with polythene followed by chicken wire mesh and 26 guage aluminium cladding for plant room area and cement plaster for exposed and underground, complete all as specified and directed, of the following sizes:- MAKE:- TATA / JINDAL / ZENITH
125mm dia
100mm dia
80mm dia
50mm dia
40mm dia
Supply, erection, testing and commisioning of mild steel class 'C', ERW pipes, laid above ground / underground as per site requirement, conforming to IS: 3589, to be used as insulated hot water piping complete with fittings, flanges, gaskets, fasteners, cement / mild steel supports wherever necessary, pressure testing of pipes including insulation of piping with 50mm thick rock wool minimum density 120kg/cu.m, covering with polythene vapour barrier followed by chicken wire mesh and 26 guage aluminium cladding for plant room area and cement plaster for exposed and underground, complete all as specified and directed, of the following sizes:- MAKE:- TATA / JINDAL / ZENITH
80mm dia
50mm dia
40mm dia
25mm dia
Supply, fixing, testing and commissioning of the following type of valves, PN16 rating as per engineering standards, of cast iron with 32mm thickness nitrile rubber insulation and 24gauge aluminium cladding where ever required as per specifications, valves spindle shall be of extended type to accommodate the insulation thickness, complete all as specifed and directed. (For Chilled water system) MAKE:- KIRLOSKAR / ADVANCE / L&T - AUDCO / CASTLE
Butterfly valve 125mm dia
Butterfly valve 100mm dia
Butterfly valve 80mm dia
Butterfly valve 50mm dia
Butterfly valve 40mm dia
Balancing valve 80mm dia
Balancing valve 100mm dia
Ball valve 25mm dia
Non-return valve 80mm dia PN 1.6 rating, confirming to relavant IS, complete all as specified and directed.
Non-return valve 125mm dia PN 1.6 rating, confirming to relavant IS, complete all as specified and directed.
Y-strainers 100mm dia NOTE:- Make shall be all as per list of manufacturers' specified here-in-after
Y-strainers 125mm dia NOTE:- Make shall be all as per list of manufacturers' specified here-in-after
Supply, install, testing and commissioning of auto airvents 20mm dia, complete all as specified and directed. MAKE:- ANERGY / CASTLE
Supply, install, testing and commissioning of 3-way motorised valves 100mm dia with rapid control actuator for chilled water as per specification along with thermostat control, complete all as specified and directed. MAKE:- JOHNSON CONTROL / HONEY WELL / SIEMENS / AUDCO / RAPID CONTROL
Supply, install, testing and commissioning of 3-way motorised valves 80mm dia with rapid control actuator for chilled water as per specification along with thermostat control, complete all as specified and directed. MAKE:- JOHNSON CONTROL / HONEY WELL / SIEMENS / AUDCO / RAPID CONTROL
Supply, erection, testing and commissioning of factory fabricated GI ducting of 19mm thickness as per IS-655 of Galvanised sheet of Class VIII with TDF flange as per the technical specifications and practice, fittings, joints for ducting, complete all as specifed and directed, for the following sizes:- MAKE:- RADIANT / SPIRAL TUBE / ZECO / ROLASTAR Note : - Cost of cutting of fly ash brick wall for erection of ducting and making good the disturbed surfaces deemed to be included in the unit rate quoted.
24 Gauge
22 Gauge
20 Gauge
18 Gauge
Supply air duct insulation with close cell elastomeric nitrite foam class O fire rating covered with factory laminated aluminium foil, 19mm thickness, complete all as specified and directed. MAKE:- ARMA FLEX / K FLEX
Return air duct insulation shalll be with close cell elastomeric nitrile foam class O fire rating covered with factory laminated aluminium foil, 13mm thickness, complete all as specified and directed. MAKE:- ARMA FLEX / K FLEX
Supply, fixing, testing and commissioning of extruded aluminium grills / diffuser made out of powder coated aluminium sections all as per manufacturers instructions, complete all as specified and directed. MAKE:- CARYAIRE / CONAIRE / AIR FLOW PVT. LTD / TROX INDIA PVT. LTD / SAGAR AIR
Supply, fixing, testing and commissioning of collar dampers gear operated made of 22guage GI frame and 26guage GI blades, complete all as specified and directed. MAKE:- CARYAIRE / CONAIRE / AIR FLOW PVT. LTD / TROX INDIA PVT. LTD / SAGAR AIR
Supply, fixing, testing and commissioning of fire dampers as per STEC pamphalete No. 22, made of 16guage GI sheet with fusible link UL listed fire rating upto 120minutes, for supply duct to isolate fire propagation, complete all as specified and directed. MAKE:- CARYAIRE / CONAIRE / AIR FLOW PVT. LTD / TROX INDIA PVT. LTD / SAGAR AIR
GI fresh air damper and wire mesh sets including cowl piece and ducting upto AHU room approximately 3metre long, standard fixing accessories etc., complete all as specified and directed. MAKE:- CARYAIRE / CONAIRE / AIR FLOW PVT. LTD / TROX INDIA PVT. LTD / SAGAR AIR
Acoustic insulation applied inside of the duct work with 25mm thick resin bonded fibre glass density 32kg/cu.m covered with RP tissue paper and finished with aluminium perforated sheet of 28 guage as per specifications, complete all as specified and directed. MAKE:- SPINTEX / UPTWIGA / BEARD SHELL / FGP / LLOYDS
Pressure gauges with syphon & cock and isolation valve etc., complete all as specified and directed. MAKE:- H-GURU / FIEBIG
Dial type Thermometers 0 to 50 degree Centigrade with syphon & cock and isolation valve etc., complete all as specified and directed. MAKE:- H-GURU / FIEBIG
Supply, Install, testing and commissioning of LT panel board CPRI approved makes as specified here-in-after, indoor type, weather & vermin proof, free standing floor mounting type, powder coated, with 8/7 tank process cable alley for all the feeders, suitable for 415Volts, 3 Phase, 4wire 50Hz AC supply system rated fault level 65KA / IS 3 phase + N + E with internal arc containment, conforming to IS, IP-54 class protection made out of 2mm thick CRCA MS sheet with 50mm x 50mm x 6mm MS angle iron frame, hinged doors front and rear openings, locking arrangement and 63mm lock, with necessary busbar mounting arrangements, with 1200 Amp aluminium busbar as per specification with and including excavation in any strata and provision of PCC 1:3:6 type C2 (40mm graded stone aggregate) platform, 100mm thick (for explosive building of 3 x 75TR AC plant) provided upto one metre around panel board, including provision of cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate with and including provision of following accessories, complete all as specified and directed. Make of Panel Board :- LOTUS POWER GEAR PVT LTD. / UNIVERSAL SWITCH GEAR CONTROL DELHI / TENCO SYSTEM AND SWITCH GEAR PVT LTD . INDORE / POWER SWITCH GEAR & CONTROL HYDERABAD / JAIHIND ELECTRICAL, AMBEGAON PUNE / VIDYUT TECHNOLOGIES INDIA PVT LTD, HYDERABAD / DYNAMIC CONTROL SYSTEM, AHMEDABAD
SL. ITEM NO. 32.00 CONTD... (a) ACB (Air Circuit Breaker) 4Pole, manual draw out type, 3 phase, 440Volts, 800 Amps, 4way, 50 KA at 500 Volts operational voltage upto 690Volts suitable for aluminium & copper termination, microprocessor release relay, overload, short circuit, earth fault relay with display shunt trip release 415Volts, coil voltage 440Volts conforming to IS:139472, with IEC 60947-2, complete in all respects - 01 No (incoming) (b) MCCB, FP, 160Amps, Icu=36 KA, 415 volts with thermal and magnetic release and adjustable overload (70% to 100%), Ics=100% Icu - 05 Nos (03 Nos for chillers, 01 No for Split AC Panel, 01 No for Hot water Generator) (c) MCCB, FP, 100Amps, Icu=16 KA, 415 volts with thermal magnetic release and adjustable overload (70% to 100%), Ics=100% Icu - 04 Nos (outgoing) (for AHU panels) (d) MCB TP 40 Amps, 10 KA, 415 volts along with automatic STAR-DELTA starter including amp meter, timer,single phase preventer and suitable size over load protector for chiller pump - 2 Nos and hot water circulating pumps - 2 Nos (f) Spare cubical without switchgear - 01 No (g) Digital multifunctional meter (A, V, W, Hz, PF) 3-phase - 1 set (h) Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 14 Sets (j) CT operated energy meter - 01 No
Supply, Install, testing and commissioning of LT panel board CPRI approved makes as specified here-in-after, indoor type, weather & vermin proof, free standing floor mounting type, powder coated, with 8/7 tank process cable alley for all the feeders, suitable for 415Volts, 3 Phase, 4wire 50Hz AC supply system rated fault level 65KA / IS 3 phase + N + E with internal arc containment, conforming to IS, IP-54 class protection and made out of 2mm thick CRCA mild steel sheet with 50mm x 50mm x 6mm angle iron frame, hinged doors, front & rear opening and locking arrangement (including provision of 65mm size Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with insulated Aluminium bus bar 1500 Amps rating for phase and neutral 4 strips, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including necessary earthwork, excavation in any strata and provision of PCC platform 100mm thick (for Non-explosive building air cooled chiller 3Nos x 89 TR AC plant) with PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) upto one metre around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multi-layer chambers to accommodate with and including provision of following accessories, complete all as specified and directed.
SL. ITEM NO. 33.00 CONTD... MAKE of Panel board :- LOTUS POWER GEAR PVT LTD. / UNIVERSAL SWITCH GEAR CONTROL DELHI / TENCO SYSTEM AND SWITCH GEAR PVT LTD . INDORE / POWER SWITCH GEAR & CONTROL HYDERABAD / JAIHIND ELECTRICAL, AMBEGAON PUNE / VIDYUT TECHNOLOGIES INDIA PVT LTD, HYDERABAD / DYNAMIC CONTROL SYSTEM, AHMEDABAD (a) ACB (Air Circuit Breaker) 4Pole, manual draw out type, 3 phase, 440Volts, 1000 Amps, 4way, 50 KA at 500 Volts operational voltage upto 690Volts suitable for aluminium & copper termination, microprocessor release relay RMS-10 / SR18G, overload, short circuit, earth fault relay with display shunt trip release 415Volts, coil voltage 440Volts conforming to IS:139472, with IEC 60947-2, complete in all respects - 01 No (incoming) (b) MCCB, FP, 250Amps, Icu=36 KA, 415 volts withthermal and magnetic release and adjustable overload (70% to 100%), Ics=100% Icu - 04 Nos (outgoing) (for 3 Nos chillers & 01 No. split AC panel) (c) MCCB, FP, 63Amps, Icu=16 KA, 415 volts with thermal magnetic release and adjustable overload (70% to 100%), Ics=100% Icu - 04 Nos (outgoing) (for AHU panels) (d) MCB FP 40 Amps, 10 KA, 415 volts along with STAR-DELTA starter including amp meter, timer, single phase preventer and suitable size over load protector for chiller pump - 2 Nos
SL. ITEM NO. 33.00 CONTD… (e) Spare cubical without switchgear - 01 No (f) Digital multifunctional meter (A, V, W, Hz, PF) 3-phase - 1set (g) Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 14 Sets (h) MCCB 4pole 415V, 125 Amp with thermal magnetic release 100 Amps, Icu=16KA and Ics = 100% Icu, with adjustable overlaod setting (with 70% to 100%) fixed magnetic setting - 02 Nos (for splic AC panels)
Supply, assembly, erection, testing and commissioning of Electrical panel cubical indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase + N + E, 415V, 50 Hz, AC with internal arc containment, internally pre-wired with copper conductor factory fabricated as per CPRI approved maks as specified here-in-after, floor mounted free standing made out of 2mm thick CRCA sheet, and shall be compartmentalised with rubber gasketed hinged door having front and rear opening for installation of separate cable alleys, bus bar chamber and switch gear compartments, dust and vermin proof duly powder coated with aluminium bus bars 200A capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided, with and including provision of the following switch gears, complete all as specified and directed: (For Non-Explosive building) MAKE of Panel board :- LOTUS POWER GEAR PVT LTD. / UNIVERSAL SWITCH GEAR CONTROL DELHI / TENCO SYSTEM AND SWITCH GEAR PVT LTD . INDORE / POWER SWITCH GEAR & CONTROL HYDERABAD / JAIHIND ELECTRICAL, AMBEGAON PUNE / VIDYUT TECHNOLOGIES INDIA PVT LTD, HYDERABAD / DYNAMIC CONTROL SYSTEM, AHMEDABAD
Supply, assembly, erection, testing and commissioning of Electrical panel cubical indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase + N + E, 415V, 50 Hz, AC with internal arc containment, internally pre-wired with copper conductor factory fabricated, CPRI approved make as specified here-in-after, floor mounted free standing made out of 2mm thick CRCA sheet, and shall be compartmentalised with rubber gasketed hinged door having front and rear opening for installation of separate cable alleys, bus bar chamber and switch gear compartments, dust and vermin proof duly powder coated with aluminium bus bars 200A capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided, with and including provision of the following switch gears, complete all as specified and directed: (For Explosive building) MAKE of Panel board :- LOTUS POWER GEAR PVT LTD. / UNIVERSAL SWITCH GEAR CONTROL DELHI / TENCO SYSTEM AND SWITCH GEAR PVT LTD . INDORE / POWER SWITCH GEAR & CONTROL HYDERABAD / JAIHIND ELECTRICAL, AMBEGAON PUNE / VIDYUT TECHNOLOGIES INDIA PVT LTD, HYDERABAD / DYNAMIC CONTROL SYSTEM, AHMEDABAD
Supplying, laying, jointing, testing and commissioning of 1100 volts grade, LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches / passing through pipe / duct / road crossing or fixed on poles, walls with suitable size clamps made of mild steel flat iron including jointing material such as lugs, brass cable glands, heavy duty double compression type etc., complete all as specified and directed, for the following sizes:- NOTE:- Excavation and Earthwork, sand cushioning, cable covers shall be measured and paid separately under respective items of this Schedule.
3.5 core 185 sq.mm
3.5 core 150 sq.mm
3.5 core 120 sq.mm
3.5 core 35 sq.mm
4 core 25 sq.mm
4 core 16 sq.mm
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25mm x 4mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C1 earth chamber with 40mm x 40mm x 6mm MS angle iron frame, 50mm thick RCC cover (1:2:4) type B1 mix with 6 Nos of 8mm dia TMT bars both ways etc., with plastering 15mm thick in CM 1:6 internally and upto 150mm below GL externally, PGI funnel with wire mesh, complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre. (ii) Earth strip and GI protection pipe (as applicable) beyond 7.50mete shall be measured and paid separately under respective item of this Schedule.
GI Perforated type cable tray, 150 mm wide, 100mm depth including cover made out of 2mm thick GI sheet, including MS supports / threaded rods and anchor fasteners whereever required as per site conditions, complete all as specified and directed. MAKE:- M/s PATNY SYSTEMS PVT. LTD. / M/s FORMTEK INDUSTRIES PVT. LTD., PUNE / M/s MANIBHADRA ELECTRICAL PVT. LTD.
Supply, Installation, testing and commissioning of high wall Split type air conditioner unit (Inverter type), BEE five star rated, of capacity 1.5 TR complete with drive motor, air cooled copper condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor units as per manufacture recommendation and fixing indoor unit on wall, provinding and making interconnection including refrigerant piping (upto 3.0 RM) with nitryle rubber insulation and control cable from indoor to outdoor upto a distance of 3.0 metre, power cabling from isolator / enclosure to unit, first charging of non CFC / non HCFC of refregerant gas including cordless remote, drain piping of 25 mm dia for connecting drain lines from indoor unit to maximum of 3.0 metre to nearest drain points, complete all as directed and specified. MAKE:- VOLTAS/ LG/ CARRIER/ BLUESTAR /TOSHIBA / DAIKIN/ LLOYD
Supply, Installation, testing and commissioning of high wall Split type air conditioner unit (Inverter type), BEE five star rated, of capacity 2.0 TR complete with drive motor, air cooled copper condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor units as per manufacture recommendation and fixing indoor unit on wall, provinding and making interconnection including refrigerant piping (upto 3.0 RM) with nitryle rubber insulation and control cable from indoor to outdoor upto a distance of 3.0 metre, power cabling from isolator / enclosure to unit, first charging of non CFC / non HCFC of refregerant gas including cordless remote, drain piping of 25 mm dia for connecting drain lines from indoor unit to maximum of 3.0 metre to nearest drain points, complete all as directed and specified. MAKE:- VOLTAS/ LG/ CARRIER/ BLUESTAR/ TOSHIBA/ DAIKIN/ LLOYD
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25mm x 4mm galvanised iron or steel strip, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, laid as a protection pipe to earth strip, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 40mm bore of pipe, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or taking out / laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil, complete all as specified and directed.
Returning, filling in, in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25cm., complete all as specified and directed.
Removing surplus excavated soils to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Spreading of natural, clean and dry river sand / M-Sand in trenches for cable protection, complete all as specified and directed. NOTE:- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover made using M20 grade of concrete, class LV, type 1, flat, size 250mm x 150mm x 40mm, conforming to IS 5820, laid with gap between adjacent covers not more than 10mm, laid as protection to XLPE under ground cables, complete all as specified and directed.
GI tubing light grade, galvanised with all fittings including short lengths, laid as a protection pipe to cables under road crossing or other situations as per site requirement, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 100mm bore of pipe, complete all as specified and directed.
Automatic Voltage stabilizer 4KVA ISI marked wall mounted 160 to 260Volts input voltage, rated output voltage 220 ± 25 Volts, rated current 14.5 Ampere, insulation Class 'B' with inbuilt electronic overload trip, protection against high / low voltage and timer for 10 seconds with efficiency of more than 97% (BIS Code 8448--1984), complete all as specified and directed. MAKE:- VOLINA / VOLTECH / V-GUARD / MICROTECH
Single pole and neutral (SPN) enclosure with a two pin and earth plug and socket complete with one SPN MCB 20A, 240V flush to wall, complete all as specified and directed.
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of casing & capping and its accessories and connecting terminal ends to DB's including providing 1 run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) Quoted rate shall deemed to include the cost of making hole in existing wall and making good disturbed surfaces to match with existing.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of surface stove enamelled steel conduit 25mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of stove enamelled steel conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) Quoted rate shall deemed to include the cost of making hole in existing wall and making good disturbed surfaces to match with existing.
MCCB DB VTPN double door 4-way sheet metal enclosure, 415V, with tinned copper 200Amp rated bus bar suitable for incomer as MCCB and outgoing as SP MCBs, complete all as specified and directed.
MCCB, 4-Pole, 415V, 63 Amp, 50Hz with thermal magnetic release and Ics = 100% Icu, with rupturing capacity 16kA, adjustable overload minimum 70% to 100%, complete all as specified and directed.
MCCB, 4-Pole, 415V, 100 Amp, 50Hz with thermal magnetic release and Ics = 100% Icu, with rupturing capacity 16kA, adjustable overload minimum 70% to 100%, complete all as specified and directed.
MCCB DB VTPN double door 4-way sheet metal enclosure, flame proof, 415V, with tinned copper 200Amp rated bus bar suitable for incomer as MCCB & outgoing SP MCBs, complete all as specified and directed.
Single pole and neutral (SPN) enclosure with a two pin and earth plug and socket complete with one SPN MCB 32A, 240V flush to wall, complete all as specified and directed.
Copper pipe of size 15.875mm (5/8 inch), including tubular heat / cold resistant rubber / foam type insulation, complete all as specified and directed.
Copper pipe of size 9.525mm (3/8 inch), including tubular heat / cold resistant rubber / foam type insulation, complete all as specified and directed.
Copper pipe of size 12.70mm (1/2 inch), including tubular heat / cold resistant rubber / foam type insulation, complete all as specified and directed.
Copper pipe of size 6.35mm (1/4 inch), including tubular heat / cold resistant rubber / foam type insulation, complete all as specified and directed.
Supply and charging of refrigerant gas 410A / 407C, complete all as specified and directed.
CPVC pipe on wall / floor including all fittings like tee, socket, bends etc., for drain pipe of 40mm dia, complete all as specified and directed.
CPVC pipe on wall / floor including all fittings like tee, socket, bends etc., for drain pipe of 20mm dia, complete all as specified and directed.
Supply, assembly, erection, testing and commissioning of Electrical panel cubical as per CPRI approved make as specified here-in-after, indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase, 415V, 50 Hz, AC, internally pre-wired with copper conductor factory fabricated by OEM approved manufacturer, floor mounted free standing as per specification with aluminium bus bars 300Amp capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation, suitable sized knock out holes for cable glands shall be provided with and including provision of the following switch gears, complete all as specified and directed. (For Explosive building) MAKE of Panel board :- LOTUS POWER GEAR PVT LTD. / UNIVERSAL SWITCH GEAR CONTROL DELHI / TENCO SYSTEM AND SWITCH GEAR PVT LTD . INDORE / POWER SWITCH GEAR & CONTROL HYDERABAD / JAIHIND ELECTRICAL, AMBEGAON PUNE / VIDYUT TECHNOLOGIES INDIA PVT LTD, HYDERABAD / DYNAMIC CONTROL SYSTEM, AHMEDABAD
Supply and fix on walls/roof/floor, hot dip solid cable tray and cover fabricated from GI sheet 2mm thick with all necessary acessories, coupler and cover etc., of size 150 mm width and 100mm depth, complete all as specified and directed. MAKE:- M/s PATNY SYSTEMS PVT. LTD. / M/s FORMTEK INDUSTRIES PVT. LTD., PUNE / M/s MANIBHADRA ELECTRICAL PVT. LTD.
Supply, assembly, erection, testing and commissioning of Electrical panel cubical as per IS / IEC - 61439 indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase, 415V, 50 Hz, AC, internally pre-wired with copper conductor factory fabricated by OEM approved manufacturer, floor mounted free standing as per specification with aluminium bus bars 400Amp capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation , suitable sized knock out holes for cable glands shall be provided with and including provision of the following switch gears, complete all as specified and directed. (For Admin building Rudram - III) MAKE of Panel board :- LOTUS POWER GEAR PVT LTD. / UNIVERSAL SWITCH GEAR CONTROL DELHI / TENCO SYSTEM AND SWITCH GEAR PVT LTD . INDORE / POWER SWITCH GEAR & CONTROL HYDERABAD / JAIHIND ELECTRICAL, AMBEGAON PUNE / VIDYUT TECHNOLOGIES INDIA PVT LTD, HYDERABAD / DYNAMIC CONTROL SYSTEM, AHMEDABAD
Supply, assembly, erection, testing and commissioning of Electrical panel cubical as per IS / IEC - 61439 indoor type powder coated with 8 / 7 tank process suitable for operation on 3-phase, 415V, 50 Hz, AC, internally pre-wired with copper conductor factory fabricated by OEM approved manufacturer, floor mounted free standing as per specification with aluminium bus bars 200Amp capacity for phases and neutral, set of three LED indicating lamps with base, air ventilation to be provided for heat dissipation , suitable sized knock out holes for cable glands shall be provided with and including provision of the following switch gears, complete all as specified and directed. (For Admin building Rudram - III) MAKE of Panel board :- LOTUS POWER GEAR PVT LTD. / UNIVERSAL SWITCH GEAR CONTROL DELHI / TENCO SYSTEM AND SWITCH GEAR PVT LTD . INDORE / POWER SWITCH GEAR & CONTROL HYDERABAD / JAIHIND ELECTRICAL, AMBEGAON PUNE / VIDYUT TECHNOLOGIES INDIA PVT LTD, HYDERABAD / DYNAMIC CONTROL SYSTEM, AHMEDABAD
Supply and fixing of control cable, 1100 Volt grade with PVC insulated copper conductor cable of size 3 core 4sq.mm, complete all as specified and directed.
Supply and fixing of control cable, 1100 Volt grade with PVC insulated copper conductor cable of size 3 core 6sq.mm, complete all as specified and directed. NOTE (for Sl. No. 69.00 & 70.00 here-in-before):- Control cable shall be provided between split AC indoor and outdoor units.
SCHEDULE 'A' PART - II Manning and operation of AC plants installed under Schedule 'A' Part - I here-in-before, for a period of 60 months after satisfactory completion of phase - I test, in respect of central AC plant 3 x 75TR capacity air cooled chiller plant and 3 x 89TR capacity air cooled chiller plant, round the clock in three shifts of 08 hours each shift (i.e., 0600 hours to 1400 hours - first shift, 1400 hours to 2200 hours - second shift and 2200 hours to 0600 hours - third shift, on all days including Sunday and Gazetted holidays, by employing one qualified tradesman in each shift for each plant, complete all as specified and directed.
For FIRST YEAR from the certified date of completion of Phase - I work as mentioned in Schedule 'A' Notes No. 1.1 here-in-before, complete all as specified and directed.
For SECOND YEAR from the certified date of completion of Phase - I work as mentioned in Schedule 'A' Notes No. 1.1 here-in-before, complete all as specified and directed.
For THIRD YEAR from the certified date of completion of Phase - I work as mentioned in Schedule 'A' Notes No. 1.1 here-in-before, complete all as specified and directed.
For FOURTH YEAR from the certified date of completion of Phase - I work as mentioned in Schedule 'A' Notes No. 1.1 here-in-before, complete all as specified and directed.
For FIFTH YEAR from the certified date of completion of Phase - I work as mentioned in Schedule 'A' Notes No. 1.1 here-in-before, complete all as specified and directed. NOTE:- (FOR SL. NO. 71.00, 71.01 to 71.05 here-in-before) (i) Manning and operation of central AC plant shall be carried out round the clock in three shifts for 24 hours (each shift of 08 hours duration) through ITI qualified tradesmen i.e., Refrigeration Mechanic for each plant. Thus contractor shall employ total 6 Nos qualified tradesmen per day for this purpose. (ii) Maintenance of log sheet and all maintenance record shall be the responsibility of contractor and no stationary shall be provided by department. Format of log sheet and maintenance records etc., shall be as decided by GE. (iii) The contractor shall ensure neat and cleanliness of all equipments installed in the premises and surrounding of AC plant room, cooling tower, water tanks, ducting, AHU rooms etc. (iv) The work covered under this Schedule shall be ordered on the contractor by the GE through a separte work order at the quoted rates, after the installations are completely taken over by the department. (v) The contractor shall keep personnel on installation with such qualification who can operate central AC plant as well as to carryout preventive / routine maintenance.
Comprehensive maintenance comprising of routine, preventive and breakdown maintenance of AC plant installed under Schedule 'A' Part - I (Sl. item No. 1.00 & 2.00 of BOQ here-in-before), for a period of 36 months after satisfactory completion of defects liability period, on all days including Sunday and Gazetted holidays, complete all as specified and directed.
For FIRST YEAR from the date of expiry of defects liability period, complete all as specified and directed.
For SECOND YEAR from the date of expiry of defects liability period, complete all as specified and directed.
For THIRD YEAR from the date of expiry of defects liability period, complete all as specified and directed.
SL. NO. 72.00 CONTD... NOTE:- (FOR SL. NO. 72.00, 72.01 to 72.03 here-in-before) (i) Separate skilled man power shall be employed against comprehensive maintenance. (ii) The contractor shall submit a maintenance schedule for the entire period of 03 (Three) years as per original manufacturer for ACs, AHUs, pumps etc., for all type of maintenance. (iii) During this period, the contractor shall be liable to maintain the complete maintenance towards routine servicing once in every quarter and labour for attending any number of breakdown calls during the contract period and fault rectification on-site as well as off-site and refrigerant gas charging as and when required. (iv) On receipt of a break down intimation, a qualified and competent team shall be deputed immediately on the same day and fault would be rectified immediately on priority basis and within 24 hrs so as to ensure that Air Conditioners are functioning satisfactorily. If failed, ₹1,000.00 per day shall be deducted from the payment due to contractor, as penalty. (v) The contractor shall arrange at his own expense all necessary tools, equipments and required parts which are required for proper execution of the work. (vi) The work of Comprehensive Maintenance shall be carried out by the original authorised service dealer only and a copy of certifcate for authorised dealership from maufacturers shall be submitted alongwith experience.
SL. NO. 72.00 CONTD… NOTE (Contd…):- (vii) Any breakdown (major or minor) shall be attended even after working hours and keep the AC's, AHUs etc., in working condition. The replacement of any parts (major / minor) shall be covered under above quoted rates which includes compressors, fans, motors, relays, capacitors, PCBs, outdoor units, indoor units, filters, battery for remotes, central controller units with LED display monitors, rewinding of AHU blower motors, blades, fan belts, AHU filters, all connected electrical, refrigerant pipelines including supply and filling of R134A / R 407C gas, leak test with supply of nitrogen gas, vaccum, topping up of compressor oil or any other minor/major spares to be replace etc. No payment what-so-ever shall be made by the department as extra. (viii) The contractor should carry out preventive maintenance once in every quarter. During maintenance the technicians should analyse the performance of complete AC's outdoor and indoor units through computer system and performance report should be kept ready as and when asked by the department. If found any fault, it should be addressed and rectify at the same time. (ix) Half yealy, the complete outdoor units to be washed with water with chemicals/solutions, if required the indoor units are also to be cleaned with water. (x) Maintenance / breakdown reports shall be resubmitted during each visit immidieatly after rectification of job. Note:- Supply of all consumables incuding rerigerant gas during comprehensive maintenance shall be iclusive in the quoted rate.
Pneumatic Engineers Pvt. Ltd.
omsai thermax engineers
Leo Air and Power Solution pvt Ltd.
Universal refrigeration and Engineering Company
UTSAV INDIA LIMITED
AIRFRAME
M/S N.K BUILDERS
SVC PROJECTS PVT. LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .