Loading…
Loading…
Tender Value
Refer Docs
Closing Date
10 Mar 2025, 2:00 pmClosed
Single Packet
Normal Tender
No
Itemwise/Consigneewise
Lowest to Highest
CONSIGNEE
Not Applicable
90 days
Expenditure
General
82
3 conditions · 3 needing a document upload
[A] Bulk order will be placed on the manufacturer or its authorized dealer or vendor having proven performance for the tendered item or similar items. The vendor firm must have satisfactorily executed at least one single purchase order placed by any Hospital of Zonal Railways/ PUS/CORE or by any Govt. Hospital for the tendered item for a minimum of 20 percent of total tendered quantity against purchase order placed during three preceding completed financial year and current year up to date of tender opening. [B] The Authorized dealer/agent must upload tender specific authorization along with the manufacturing license of OEM issued by appropriate authority/Govt. body to OEM & brochure of the product. In case the Tenderers/ Bidders do not submit the requisite documents as detailed above along with their offer, then the tender will be decided on the basis of their past supply performance records as available with Hospital in Hospital of SER [if any] and no back reference shall be made in this regard.
The Authorized dealer/agent of the approved vendors/OEM must upload tender specific authorization in proper format, failing by which their offer will be summarily rejected.
OEM must submit the license of manufacturing issued by the appropriate authority/Govt. body along with the brochure of the product.
34 conditions · 4 needing a document upload
[i] Have you attached the past performance credentials with your offer?
[ii] Have you checked properly the documents attached with the tender wherever is necessary as per tendered schedule?
FOR: Destination.
All the bidders are advised to submit certificate of compliance for sharing land border with India as per the clause 32 and proforma at annexure - 8 of GCC attached.
Bidders are reminded to carefully go through IRS conditions of contract (included and uploaded alongwith the bid document) particularly those pertaining to Code of Integrity, Misdemeanor and penal measures. If two or more bidders are found to be sister concerns of affiliates (having common partner/director/promoter/owner/holding company decision control etc.) the offers of all such sister concern sare liable to be rejected as per relevant provisions of IRS terms and condition.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1 condition
Code of Integrity Declaration: I/We have carefully gone through the IRS conditions of contract(included and uploaded along with the bid document) particularly Para 2500 pertaining to code of Integrity, Misdemeanor of Penalties . I/We hereby certify that no other concerns or affiliates (such as having common partner/director promoter/ owner/holding company/ management control etc.)have participated in this tender which give rise to a conflict to interest or fall under anti-competitive practices. We understand that the offers of all such related concerns including ours are liable to be rejected as per relevant provisions of IRS terms and conditions. I/We, affirm that we shall abide by the code of integrity in general, with specific reference to conflict of interest [Para 2502(e)], anti competitive practices [Para2502 (c)] and obligation to proactive disclosures [ Para 2503 ]. I/We, understand that we are fully responsible for the above declaration and it shall not be the Railway's responsibility to verify the same. I/We aware that we shall be liable for all consequences of violation of Code of Integrity, if detected/damaged at any stage.
1 location across West Bengal · 800 Numbers total
TRILUMEN CENTRAL VENOUS CATHETER . SPECIFICATION - BLOOD SPILLAGE LESS INSERTION TECHNIQUE WITH POLYURETHENE RADIO PAQUE TRIPLE LUMEN CENTRAL VENOUS CATHETER 7 Fr - 15Cm WITH INJECTION T SITE CAPS . RAULERSON SYRRINGE / INTRODUCER NEEDLE PLUS KINK FREE NITINOL CORE GUIDEWIRE . TWO INTRODUCES NEEDLE MUST BE PROVED Y SHAPED AND STRAIGHT BOTH ALONG WITH SURGICAL DRESSING FOR CENTRAL LINE AND VESSEL DILATOR AND A LIPID RESISTANT STOP COCK . THE CATHETER MUST BE THERMOSENSITIVE POLY URETHANE WITH ATRAUMATIC TIP AND ADDITIONAL FIXATION WING SHOULD BE PROVED .
HB255173A
HB255173A
Open - Indigenous
Goods
West Bengal
₹0
Exempted
10 Mar 2025
27 Feb 2025
1 item · 800 Numbers total
TRILUMEN CENTRAL VENOUS CATHETER . SPECIFICATION - BLOOD SPILLAGE LESS INSER TION TECHNIQUE WITH POLYURETHENE RADIO PAQUE TRIPLE LUMEN CENTRAL VENOUS CATHETER 7 Fr - 15Cm WITH INJECTION T SITE CAPS . RAULERSON SYRRINGE / INTRODUCER NEEDLE PLUS KINK FREE NITINOL CORE GUIDEWIRE . TWO INTRODUCES NEEDLE MUST BE PROVED Y SHAPED AND STRAIGHT B OTH ALONG WITH SURGICAL DRESSING FOR CENTRAL LINE AND VESSEL DILATOR AND A LIPID RESISTA NT STOP COCK . THE CATHETER MUST BE THERMOSENSITIVE POLY URETHANE WITH ATRAUMATIC TIP A ND ADDITIONAL FIXATION WING SHOULD BE PROVED . Sample Clause: "For quality assessment with wr itten consent that sealed sterile pack will be opened for inspection and will be returned in pack open st ate along with bids" [ Warranty Period: 12 Months after the date of delivery ] ]
| Delivery Location | State | Quantity |
|---|---|---|
| MATRON GR-I/GRC, SER | West Bengal | 800.00 Numbers |
| Total | 800 Numbers | |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
4872858.pdf
ATTACHMENT
4777113.pdf
ATTACHMENT
4410391.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .