Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹21.4 L Quoted ₹22.8 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹25.3 L+₹2.5 L (10.8%)Rejected-Finance | ₹25.3 L+₹2.5 L (10.8%) | L2 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
REPR MAINT OF SECURITY STREET GATE LIGHT PERIMETER ILLUMINATION SYSTEM INCL CONTROL PANELS BLDG EARTHING MAINT OF DG SET LT FEEDER PILLAR CAPACITOR PANELS UPS STABILISERS AND CONEECTED ITEMS AT MH DHANGU MILITARY COMPLEX UNDER GE S PATHANKOT
2021_MES_492514_1
GES/PKT/T-43/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹62,000
Yes
17 Feb 2022
4 Dec 2021
5 Jan 2022
4 Dec 2021
3 Jan 2022
20 Dec 2021
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
All as per Srl Item no. 01 above item but exceeding depth 1.5 mtr and n exceeding 3 mtrs
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available, laid along alignment of cable as protection to cable in trenches, complete all as specified and directed.
Supply, laying and testing of LT, UG cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining, cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
All as per item No 07 above but of size 16 Sqmm 04 core
All as per item No 07 above but of size 25 Sqmm 4 core
All as per item No 07 above but of size 35 Sqmm 3.5 core
All as per item No 07 above but of size 70 Sqmm 3.5 core
All as per item No 07 above but of size 95 Sqmm 3.5 core
All as per item No 07 above but of size 120 Sqmm 3.5 core
All as per item No 07 above but of size 150 Sqmm 3.5 core
All as per item No 07 above but of size 240 Sqmm 3.5 core
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 6 to 16 Sqmm 3.5/4 core with working voltage 1100 volts .
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 16 to 50 sq.mm.
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 150 to185 sq.mm.
Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole.Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint.
Dismantlin of ACSR conductor of any size, from insulator etc from the structure/over head line, M&L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators all as directed.
Dismantling insulators any type, size, M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade.
M&L for GI pipe light grade 15 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings/ plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
Supplying and fixing in replacement of old u/s service cable size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
All as per Srl item No. 26 above but for service cable of size 10 sqmm twin core.
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like lamp, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
supply and fix in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels .
Supply only the following spares parts suitable for LED street/Flood light fittings of
Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting
Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting
Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Taking down old unserviceable street light fittings from any height and Supply & Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 9000 lumens suitable wattage for efficiency not less than 100 lumens/Watt,min wattage 90 watt, with ingress protection IP 65 and SPD of capacity 10 KV etc complete and testing on completion all as specified and as directed. Note: The GI pipe if rquired bracket will be measured and paid separately under relevant schedule items
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
Supply & fixing in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc complete all as directed.
3 Pole MCCB, 415 V, Adjustable type with breaking capacity 35 KA, 320-400 Amp rated
3 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 125-160 Amp rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 160-200 Amp rated
3 Pole MCCB, 415 V, Adjustable type with breaking capacity 16 KA, 40-100 Amp rated
M & L for replacement of unsv/broken thermoplastic polycarbonate spring type locks suitable for panel locking (Mi DV 01 with Mi SR 4) complete
Restretching of ACSR conductor of any size of over head lines LT/ HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: ACSR conductor Required for winding etc to be included in quoted rates.
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and GI wire 4 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 8 sqmm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mm including dismantling old one.
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4mm dia galvanised iron or steel wire including dismantling old one.
Dismantling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made Outdoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet floor mounted, with angle iron base frame made of 40 x 40 x 6mm, 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (b) LED Indicator RYB -01 Set (Set of three). Note: (i)The panel shall be as per CPRI certificate. (ii) PCC will be measured and paid separately.
Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Cutting, trimming of hanging/ extended braches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorised diesel operated hacksaw etc complete. One span comprises of 3 to 5 conductors of any distance between one pole to adjacent pole including trimming of all tree branches in vicinty & around poles /conductor & will be measured as one span. Necessary prior permission shall be obtained from concerned I/C JE E/M before carrying out the work. All safety measures & insurance to the staff undertaking the Job shall be the Contractor's responsibility.
Supply and fixing in repair Test point terminal block made of gun metal or phosphorus bronze size 75x 75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws including provision of 30 cmx25cmx8cm sheet metal box made out of 3.15 m thick CRCA sheet with front hinged door shutter & locking arrangement and duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
S&F loop-in/loop-out box of outer size size 250x 210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
Material and Labour for Galvanised iron round bracket made out of 40mm dia GI tubing including making provision for fixing of 04/06 no flood light on 11 mtr steel tubular pole ad fixing and connecting up of LED lights (LED lights shall be measured seperately under respective items of sch ) complete all as specified and directed. Note: The inner diameter of ring shall not be less than 1.0 meter
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ blackground etc complete all as directed
Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enamelled copper wire all as per existing and servicing/greasing of reduction gear box complete all as specified and directed.
Decarbonising of the control panel of High mast/ Mid mast and including sevicing of parts such as contactors/timers including replacement of pitted lugs,thimbles, control wiring etc complete including painting with a coat of synthetic enamel paint
M & L for preparation of old painted surfaces of 09/11 m long steel poles incl removing oily/greasy sports and applying one coat of aluminium paint complete above 1.5 mtr and one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed
M & L for preparation of old painted surfaces of 09/11 m long PCC poles incl removing oily/greasy sports and applying one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
Dismantling the defective LT UT cable 3.5/ 4 core from panel/DB/junction boxes, dismentling the cable gland if any, removing the pitted/burnt aluminium lugs and suplly and fixing of aluminium paim type lugs or lugs as per existing, crimping with suitable size crymping tool bit, refixing/ replacing cable gland, refixing the cable with suitable nut bolts & washers etc complete for the following size cable:- (Note:(i) one set of triple pole and neutral lugs will be measured as one job. (ii) The rate quoted deemed to be inclusive of insulation tape, nut bolts & washers etc complete. (iii)cable gland will be measured and paid separately.(iv) The rate quoted deemed to be inclusive the necessary earth work for removing loop of cable if any required complete all as directed
S&F in repair capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.
S&F in repair capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor
S&F in repair Double metalised paper and polypropylene technology(Mixed dielectric) capacitor cylindrical/box type for per KVAR power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR
M&L in replacement of existing unserviceable conector of current caring range 25 A to 40 Amp (AC-3 duty at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.
M&L in replacement of existing unserviceable conector of current caring range 9 A to 18 Amp (AC-3 duty at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.
M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT paneles/APFC panels including required electrical connections & testing all as directed.
M&L in replacement of existing unserviceable MCB 32-63 Amps TPN 415 volts at different places in LT paneles/APFC panels including required electrical connections & testing all as directed.
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage.
M&L for replacement of existing unservicible fan belt and testing complete for 50KVA to 63KVA capacity of DG sets and any make as per OEM.
M&L for replacement of existing unservicible fan belt and testing complete for 320KVA capacity of DG sets and any make as per OEM.
taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removel of leakage , welding brazing & refixing it duly repaired etc comlete all as directed for 320KVA capacity of DG sets and any make as per OEM.
M&L for repair and overhauling of unsv self starter 12V/24V of any capacity DG set including repair/ replacement unsv/defective spares such as field coil, armature winding , carbon bushes, and pinion assy complete all as specified and directed.
M&L for repair and overhauling of unsv dynamo/ alternator12V/24V of any capacity DG set including repair/ replacement unsv/defective spares such as field coil, armature winding , carbon bushes, and pinion assy complete all as specified and directed.
Taking out the old unserviceable battery from the DG set and supply and fix new 12 V, 180AH maitenance free battery make Amron /Exide including testing and commissioning complete all as specified and directed.
M&L for calibration of fuel pump including replacement of unsv/defective spares of 320 KVA DG set of any make and model complete all as directed.
M&L for calibration of fuel pump including replacement of unsv/defective spares of50to 62.5 KVA DG set of any make and model complete all as directed.
M&L for overhauling and calibration of fuel injector assembly including replacement of unsv /defective spare of 320 KVA DG set of any make and model complete all as directed
Supply and fix in replacement battery leads set ,PVC insulated multisrander, copper conductor of minimum size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitablefor DG sets of different capacities.
M / L for replacement of coolant for radiator for DG set at various locations.
Taking out main transformer of the voltage stabilizer of capacity 50 KVA for repair/rewinding. Rewinding of main transformer using super enameled copper winding wire of existing gauge including latherite paper,PVC sheets,sleeves etc all as required. Varnishing complete with insulating varnish, drying and refixinng to the stabilizer after testing all as required at site or directed.
Taking out main transformer of the voltage stabilizer of capacity 500 KVA for repair/rewinding. Rewinding of main transformer using super enameled copper winding wire of existing gauge including latherite paper,PVC sheets,sleeves etc all as required. Varnishing complete with insulating varnish, drying and refixinng to the stabilizer after testing all as required at site or directed.
M&L for scraping old paint from the voltage stabilizer 3 phase 50 KVA to 100 KVA cap and preparation of surfaces for painting. Repainting the voltage stabilizers by spraying synthetic enamel paint of approved colour, writing SM/ MES No and cap with white paint all as required at site or directed.
All as per Srl item 101 above, but 500 KVA all as required at site or directed.
M&L for carrying out servicing & maintainance of UPS of capacity 20 KVA of Make: M/s SUKAM by strip opening of UPS, inspection/servicing of all spare parts such as Drive cards, relay cards, Ac capacitors, inverter coolong fan, ceramic fuses, batteries and including repacing the defective spares if any complete, ressembling, calibration of UPS complete and testing & commissioning complete all as directed. Note : Major Spares such as inverter Card/Rectifier Card, AC/DC capacitors, replacement of batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses,SCR ,inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.
M&L for carrying out servicing & maintainance of UPS of capacity 15 KVA of Make: M/s SUKAM/Delta by strip opening of UPS, inspection/servicing of all spare parts such as Drive cards, relay cards, Ac capacitors, inverter coolong fan, ceramic fuses, batteries and including repacing the defective spares if any complete, ressembling, calibration of UPS complete and testing & commissioning complete all as directed. Note : Major Spares such as inverter Card/Rectifier Card, AC/DC capacitors, replacement of batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses,SCR ,inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.
Supply only the following spares for carrying out repairs to UPS of capacity 15/ 20 KVA of Make: Sukam/Delta under item No. 99 & 100 above
Inverter Card
Rectifier Card
AC capacitor
DC capacitor
12 V 42 AH SMF batteries
Supply & fixing in replacement of unsv 4 Pole on load changeover switch of following current carrying capacity 100 Amps including necessary additional/alteration to busbars of existing panel etc complete all as directed.
All as per srl item No.111 above but of capacity 125 Amps Capacity
All as per srl item No.111 above but of capacity 200 Amps Capacity
Taking out U/S control wiring complete from stabilizer of capacity 50 KVA to 100 KVA, 3 phase 415 volts any make for unbalanced load, providing wiring loom complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc (Note: Additional items required to make stabilizers serviceable will be measured and paid for separately under respective items)
Supply only the following spares for carrying out repairs to voltage stabilizer of capacity 50 KVA to 100 KVA.
(a) Voltmeter digital type LED display 50 to 550 Volts, AC supply of size 96x96mm acuracy class 1.0.
(b) Printed control card circuit
(c) Limit switch
(d) Toggle switch 2 way, 5 amps, 230 volts
(e) Synchronous motor single phase AC 230 volts with torque up to 5 kg/CM all as required or directed
(f) Control transformer with primary voltage 230 Volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer.
(g) Push button
(h) Variable resistance (pre set) with lock nuts
(j) Resistant of synchronous motor, any rating upto 1 K-10 W+10%
(k) Dimmer stat
(l) Brass stud with nut and washers
(m) Carbon brush with Clamp
Supply only the following spares for carrying out repairs to voltage stabilizer of capacity 50 KVA to 100 KVA.
(a) Voltmeter digital type LED display 50 to 550 Volts, AC supply of size 96x96mm acuracy class 1.0.
(b) Printed control card circuit
(c) Limit switch
(d) Toggle switch 2 way, 5 amps, 230 volts
(e) Synchronous motor single phase AC 230 volts with torque up to 5 kg/CM all as required or directed
(f) Control transformer with primary voltage 230 Volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer.
(g) Push button
(h) Variable resistance (pre set) with lock nuts
(j) Resistant of synchronous motor, any rating upto 1 K-10 W+10%
(k) Dimmer stat
(l) Brass stud with nut and washers
(m) Carbon brush with Clamp
Taking out U/S control wiring complete from stabilizer of capacity 500 KVA, 3 phase 415 volts any make for unbalanced load, providing wiring loom complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc (Note: Additional items required to make stabilizers serviceable will be measured and paid for separately under respective items)
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/s. Aggarwal Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .