Loading…
Loading…
Tender Value
₹7.5 Cr
EMD Value
₹3.8 L
Closing Date
23 Jul 2026, 5:00 pm
MR Yognarayan sahu(DFLT)
CE(Ambikapur)
CONSTRUCTION OF DISTIRCT LEVEL MULTIPURPOSE STADIUM, DIST. M.C.B. (C.G.) ( DEPOSIT WORK). (Without Escalation and Bonus)
194543
NIT NO: 615/TC/2026-27
RESTRICTED TENDER
WORKS
12 days
CE(Ambikapur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Ambikapur)
PWD Circle, Ambikapur
Koria Division Manendragarh
120
12
No
0
194543
23 Jul, 2026 5:00:00 PM IST
28 Jul, 2026 10:00:00 AM IST
2 Jul, 2026 5:00:00 PM IST
NIT NO: 615/TC/2026-27
CONSTRUCTION OF DISTIRCT LEVEL MULTIPURPOSE STADIUM, DIST. M.C.B. (C.G.) ( DEPOSIT WORK). (Without Escalation and Bonus)
377450.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
75486000.00
2
27 Jul, 2026 5:00:00 PM IST
75486000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 16h 21m
17 documents required · 11 mandatory · 6 optional
₹0
₹3.8 L
30 Jun 2026
30 Jun 2026
28 Jul 2026
2 Jul 2026
23 Jul 2026
2 Jul 2026
27 Jul 2026
CONSTRUCTION OF DISTIRCT LEVEL MULTIPURPOSE STADIUM, DIST. M.C.B. (C.G.)
MAKE LIST OF APPROVED ELECTRICAL MATERIALS
S. No. Items Make Remarks
1- Switch, Socket and other accessories with plate and board. (Common type fitting Only) 1- Anchor
2- PVC pipe & Accessories (2mm thickness heavy duty) 1- Dauphin
3- PVC copper wire standard with FRLS wire 1- Polycab
4- MCCB/MCB & MCB DB 1- L&T
5- Power cable 1- Polycab – ISI mark
6- Ceiling fan 1- Usha- Appollo
2- Bajaj - Grace Gold
4- Crompton-Hispeed
7- Exhaust fan /Wall fan 1- Bajaj
8- Submersible water pump 1- CRI
2- Crompton greaves
9- HDPE Pipe 1- Finolex
10- LED/Conventional Luminaires/Tube Lights 1- Wipro
11- LED Street Light 1- Wipro- Sky line
2- Schneider - Ampera
3- OSRAM - LED vvo Plus
12- Main Switch (Switch Fuse Unit) 1- Havells
13- Split Air Conditioners 1- Blue Star
14- Octagonal Pole & HM Shaft 1- R. R. Ispat
NIT SCHEDULE FOR CONSTRUCTION OF DISTRICT LEVEL MULTIPURPOSE STADIUM, DISTT. M.C.B. (C.G.)
To enable entering data into the sheet, please click on 'Enable Editing'.
Please insert items from 12th row.
Every row will be considered as a distinct item.
The row, in which the two fields- 'Item Code' and 'Description' are blank, will not be considered.
If 'CREDIT ITEM' is not entered, default value '0' will be taken.
If 'Calc Field' is not entered, default value 'N' will be taken.
MAX ITEM LIMIT IN EACH EXCEL FILE IS 1000
P.A.C. Rs. 754.86 Lacs
S. No. Department SOR Year Item Code Description UOM Rate Quantity Amount Ref Serial No CREDIT ITEM (0/1) Calc Field (Y/N) Offset Price
1 PWD PWD BLD 2015 1.1 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area). sqm 7.20 19952.48 143658 0 0 N 0
2 PWD PWD BLD 2015 1.4 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. sqm 3.70 20100.00 74370 0 0 N 0
3 PWD PWD BLD 2015 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.1.1 In ordinary Soils. cum 185.00 2055.74 380312 0 0 N 0
4 PWD PWD BLD 2015 1.1.2 In ordinary rocks. cum 267.00 427.24 114073 0 0 N 0
5 PWD PWD BLD 2015 1.6 Extra for every additional lift of 1.5 m or part thereof. 1.6.1 All types of soils cum 26.50 149.86 3971 0 0 N 0
6 PWD PWD BLD 2015 1.6.2 Ordinary or hard rocks cum 47.50 427.24 20294 0 0 N 0
7 PWD PWD BLD 2015 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. cum 65.00 341.14 22174 0 0 N 0
8 PWD PWD BLD 2015 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. cum 371.00 2035.91 755321 0 0 N 0
9 PWD PWD BLD 2015 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). cum 2970.00 310.51 922200 0 0 N 0
10 PWD PWD BLD 2015 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). cum 4163.00 964.10 4013557 0 0 N 0
11 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 97.50 364.37 35526 0 0 N 0
12 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 4260.50 249.46 1062824 0 0 N 0
13 PWD PWD BLD 2015 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: 3.12.1 Thermo-Mechanically treated bars FE 415 kg 54.50 114747.46 6253737 0 0 N 0
14 PWD PWD BLD 2015 3.12.2 Thermo-Mechanically treated bars FE 500D kg 54.50 25282.55 1377899 0 0 N 0
15 PWD PWD BLD 2015 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. cum 4237.00 0.57 2415 0 0 N 0
16 PWD PWD BLD 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. kg 67.50 2186 147554 0 0 N 0
17 PWD PWD BLD 2015 9.18 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate primer. 9.18.4 Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet. meter 474.00 227.00 107598 0 0 N 0
18 PWD PWD BLD 2015 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). 12.46.2 Granite stone black sqm 2719.00 70.80 192505 0 0 N 0
19 PWD PWD BLD 2015 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for arately: 9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). kg 338.00 495.00 167310 0 0 N 0
20 PWD PWD BLD 2015 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 9.51.2 With float glass panes of 5 mm thickness sqm 708.00 49.50 35046 0 0 N 0
21 PWD PWD BLD 2015 9.34 Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete. sqm 791.00 49.50 39155 0 0 N 0
22 PWD PWD BLD 2015 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. 9.57.1 SS Grade 204 kg 467.00 136.800 63886 0 0 N 0
23 PWD PWD BLD 2015 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. sqm 3330.00 23.04 76723 0 0 N 0
24 PWD PWD BLD 2015 10.11 Supply and fixing of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. sqm 636.00 3185.07 2025705 0 0 N 0
25 PWD PWD BLD 2015 10.16 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : 10.16.1 Ridges plain (500-600mm) meter 552.00 45.70 25226 0 0 N 0
26 PWD PWD BLD 2015 10.10 Extra for providing and fixing wind ties of 40x6mm flat iron section. meter 118.00 548.40 64711 0 0 N 0
27 PWD PWD BLD 2015 9.2 Structural steel work riveted or bolted or welded in built-up sections, trusses and frames work upto a height of 5m above plinth level, including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. kg 66.00 166801.2 11008879 0 0 N 0
28 PWD PWD BLD 2015 9.5 Extra for hoisting trusses and placing in position over height above 5m for every 2.5 m height or part thereof. kg 5.40 166801.20 900726 0 0 N 0
29 PWD PWD BLD 2015 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. sqm 139.00 4371.46 607633 0 0 N 0
30 PWD PWD BLD 2015 2.1 2.1.2 Wall of any thickness including attached pilasters, buttresses etc. in super structure. sqm 228.00 95.06 21674 0 0 N 0
31 PWD PWD BLD 2015 2.1 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape. sqm 297.00 1807.23 536747 0 0 N 0
32 PWD PWD BLD 2015 2.1 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235.00 1096.38 257649 0 0 N 0
33 PWD PWD BLD 2015 2.1 2.1.8 Beams, lintels, cantilevers & walls. sqm 202.00 592.94 119774 0 0 N 0
34 PWD PWD BLD 2015 2.1 2.1.13 Weather shade, chhajja, Cornices and mouldings sqm 294.00 97.68 28718 0 0 N 0
35 PWD PWD BLD 2015 2.1 2.1.15Stair cases of all types excluding spiral and folded plate type, including risers and landings sqm 230.00 195.95 45069 0 0 N 0
36 PWD PWD BLD 2015 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand) cum 3263.00 481.94 1572570 0 0 N 0
37 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 3384.00 254.58 861499 0 0 N 0
38 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 121.00 184.06 22271 0 0 N 0
39 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 242.00 228.84 55379 0 0 N 0
40 PWD PWD BLD 2015 7.11 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: 7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand) sqm 382.00 1687.55 644644 0 0 N 0
41 PWD PWD BLD 2015 7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. sqm 62.50 1600.80 100050 0 0 N 0
42 PWD PWD BLD 2015 10.61 Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. sqm 658.00 414.76 272912 0 0 N 0
43 PWD PWD BLD 2015 8.158 Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete. each 1450.00 57.00 82650 0 0 N 0
44 PWD PWD BLD 2015 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height. sqm 86.00 375.00 32250 0 0 N 0
45 PWD PWD BLD 2015 1.25 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) 1.25.1 Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm sqm 27.50 4224.00 116160 0 0 N 0
46 PWD PWD BLD 2015 1.25 1.25.2 Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). sqm 19.00 265.00 5035 0 0 N 0
47 PWD PWD BLD 2015 1.25 1.25.3 Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). sqm 13.50 500.00 6750 0 0 N 0
48 PWD PWD BLD 2015 1.22 Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. litre 208.00 160.00 33280 0 0 N 0
49 PWD PWD BLD 2015 1.19 Providing filling and compacting local earth (from approved source pit) in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. cum 242.00 2400.00 580800 0 0 N 0
50 PWD PWD BLD 2015 11.2 Providing and making 12mm thick cement plaster of mix: 11.2.2 In Cement Mortar 1:4 (1 cement : 4 fine sand) sqm 103.00 94.13 9695 0 0 N 0
51 PWD PWD BLD 2015 11.2 11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 91.50 5236.72 479160 0 0 N 0
52 PWD PWD BLD 2015 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: 11.3.3 In Cement Mortar 1:5 (1 cement : 5 fine sand) sqm 113.00 2027.32 229087 0 0 N 0
53 PWD PWD BLD 2015 11.3 11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 107.00 2056.26 220020 0 0 N 0
54 PWD PWD BLD 2015 11.5 Neat Cement punning. sqm 33.00 94.13 3106 0 0 N 0
55 PWD PWD BLD 2015 12.74 Providing and laying rectified ceramic glazed floor tiles of 1st class quality confirming to IS : 15622-2017 of approved make, in all colours, shades over 20 mm thick bed of Cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per SqM including pointing the joints with white cement mixed with matching pigment etc., complete. 12.74.1 Size 300x300 mm thickness 7 to 8 mm sqm 779.00 104.94 81748 0 0 N 0
56 PWD PWD BLD 2015 12.75 Providing and fixing ceramic glazed wall/dado tiles of 1st quality conforming to IS : 15622-2017 of approved make, in all colours, shades on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. 12.75.1 Size 300x450 mm thickness 7 to 8 mm sqm 710.00 144.48 102581 0 0 N 0
57 PWD PWD BLD 2015 12.44 Extra for nosing in Granite stone for treads. meter 126.00 144.00 18144 0 0 N 0
58 PWD PWD BLD 2015 12.45 15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) 12.45.3 Granite stone lakha red/ shahi red sqm 4200.00 594.58 2497236 0 0 N 0
59 PWD PWD BLD 2015 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). 12.46.3 Granite stone lakha red/ shahi red sqm 4273.00 40.44 172800 0 0 N 0
60 PWD PWD BLD 2015 9.60 Designing, providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade (NORTON or equivalent), on aluminium sections for fixing aluminium/ glass panel, sealing on periphery of frame work, by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure including hire charges of double scaffolding complete. kg 357.00 4260.00 1520820 0 0 N 0
61 PWD PWD BLD 2015 9.61 Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame to be paid separately) 9.61.2 4mm thick sqm 1745.00 426.00 743370 0 0 N 0
62 PWD PWD BLD 2015 12.65 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm 12.65.2Pigment Coloured (rubber mould) precast interlock concrete blocks sqm 632.00 1014.20 640974 0 0 N 0
63 PWD PWD BLD 2015 12.3 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.1 40 mm thick sqm 222.00 969.42 215211 0 0 N 0
65 PWD PWD BLD 2015 8.12 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 8.12.2 35 mm. thick (single leaf) sqm 2005.00 47.82 95879 0 0 N 0
66 PWD PWD BLD 2015 8.148 Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge8.148.2Extruded section Profile size 42x50 mm. meter 196.00 67.20 13171 0 0 N 0
67 PWD PWD BLD 2015 8.149 Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.8.149.24 mm thick door shutters with styles and rails of size 59x24 mm sqm 2399.00 22.40 53738 0 0 N 0
68 PWD PWD BLD 2015 8.58 Providing and fixing bright finished brass butt hinges with brass polished MS screws complete:8.58.675x40x2.50 mm (Ordinary Type) each 88.50 114.00 10089 0 0 N 0
69 PWD PWD BLD 2015 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete: 8.60.1)300x16mm each 475.00 6.00 2850 0 0 N 0
71 PWD PWD BLD 2015 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:8.62.2200x10mm each 231.00 12.00 2772 0 0 N 0
72 PWD PWD BLD 2015 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete:8.65.1125 mm each 55.50 36.00 1998 0 0 N 0
73 PWD PWD BLD 2015 8.73 Providing and fixing 150mm bright finished brass floor door stopper with rubber cushion & brass polished MS screws etc complete to suit the shutter thickness. each 73.00 18.00 1314 0 0 N 0
74 PWD PWD BLD 2015 14.14 Finishing walls with water proofing cement paint of required shade to give an even shade. 14.14.1 On new work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 41.00 3631.26 148882 0 0 N 0
75 PWD PWD BLD 2015 14.22 Painting on new work (two or more coats) to give an even shade with:14.22.1)Satin synthetic enamel paint sqm 55.00 40.59 2232 0 0 N 0
76 PWD PWD BLD 2015 14.57 Providing and applying 2mm thick white cement based Acrylic grade putty with minimum 3 coats applied @ 4.0 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Asian trucare, Berger Happy walls Putty , Birla Opus One pro smooth) to make the surface smooth and even with all tools tackles and labour etc. complete for the work . (This Item to be use in heigher grade painting works Item No. 14.65) sqm 95.00 6270.24 595673 0 0 N 0
77 PWD PWD BLD 2015 14.63 Providing and applying Economy Plastic emulsion paint with roller application minimum three coats appied @ 1.25 lit / 10 Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C (Glossy and Semi Glossy Finish) of required shade (product such as Tractor emulsion , Dulux Promise, Nerolac Bueaty Silver, Berger bison/breeze , Opus I30/ Style Paint) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work . (With 2 Year warranty). sqm 74.00 2994.37 221583 0 0 N 0
78 PWD PWD BLD 2015 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.) sqm 84.00 1568.01 131713 0 0 N 0
79 PWD PWD BLD 2015 14.71 2.0mm thickness (average) having design scratched with leveled & smooth surface. sqm 133.00 892.60 118716 0 0 N 0
80 PWD PWD BLD 2015 14.9 Distempering with acrylic washable distemper to give an even shade.(14.9.1)On new work (Two or more coats) sqm 38.00 33.60 1277 0 0 N 0
81 PWD PWD BLD 2015 10.66 Proving and fixing Acoustical Suspended Ceiling System made of GRG Glass fibre reinforced gypsum tiles with Micro look edge and size 595x595x12mm as approved by Engineer-In-charge, in true Horizontal Level Suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @120 gsm/sqm, both side inclusive) consisting of main "T" Runner with suitably spaced joints to get required length and of size 15x32mm made from 0.30 thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 15x32mm made of 0.30 thick (minimum) sheet, 1200 mm long spaced between main "T" at 600mm center to center to form grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 15x32mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 14x20mm and laying false ceiling tiles of approved texture in the grid,cutting/ making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc wherever required. Main "T" runner to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4mm dia GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along main "T". Bottom exposed width of 15mm of all "T" sections shall be pre painted with polyester paint, all complete for all heights as per specification drawings or as directed by Engineer-In-Charge. The tiles should have Humidity resistance (RH) of 99%, Light Reflectance >83%, Thermal Conductivity K=0.052-0.57w/mk, colour white, fire performance UK class 0/ Class 1(BS 476 pt-6 and 7) in module size of 600x600x16 mm with Bio Block coating on the face of the tile, suitable for green building application, with recycled content of 38-41%. Ceiling height up 3.5 mt from adjacent floor level.Extra height to be paid separately. sqm 1290.00 969.42 1250552 0 0 N 0
82 PWD PWD BLD 2015 NOR SOR INSTALLATION & FINISHING OF AIR-CUSH WOODEN SPORTS FLOORING SYSTEM (VOLLEYBALL/T.Tennis/ squash Court) WITH WARRANTY PERIOD FOR 5 YEARS FOR MATERIAL AND INSTALLATION APPLICATION The SURFACE BOARD: Kiln seasoned imported Maple Wood (sycamore) surface board finished with 21 mm thick, 50-110 mm width and in random length in tongue and groove shape The edges of the boards will have a finger lock groove and the bottom side with air pass groove The SURFACE BOARD: Kiln seasoned imported Maple Wood (sycamore) surface board finished with 21 mm thick, 50-110 mm width and in random length in tongue and groove shape The edges of the boards will have a finger lock groove and the bottom side with air pass groove THE UNDER FRAME: made of commercial quality fir/spruce/pine wood runners of 90/70 mmx45 mm treated with anti-termite solution and fixed on the bottom side with 18 mm thick air cushioning pads by nails through the two wings at 350 mm. c/c THE INSTALLATIN: a vapour barnor of 6 mm (600 micron) thick will be placed on the levelled IPS sub-floor before laying the under frame The runners having air cell cushioning pads will be placed on the vapour barrier in perfect level at 350 mm cic in on direction The surface boards will be screwed to the runners through the tongue only and will lock the screwed tonge by the groove of the adjoining boards The ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive An expansion gap of 8 to 10 mm will be left open between the wooden flooring and the surrounding tiled area/wall THE FINISHING: after installation the floor will be machine sanded in uniform level and finished with Imported Non-skid Din Certified polyurethine lacquer Game Line marking will be carried out in required colors before applying the finish coat MATERIAL (1) The timber used for surface boards will be imported maple. (2) The varying color of the wood due to its natural characterstics will not be considered as a defect (3) All timber will be free from loose knots, bee or borer holes splits, cracks and fungal attack (4) All timber will be kiin seasoned with moisture content of app. 12% sqm 6475.00 969.42 6276995 0 0 N 0
83 PWD PWD BLD 2015 NSR GAME LINE MARKING: under the wooden floor polishing in suitable colour as per international sport standard using synthetic enamel paint which is in sandwich system with sand papening and primer to exposed surface. each 11800.00 2.00 23600 0 0 N 0
84 PWD PWD BLD 2015 19.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK19.6.3 )25 mm nominal outer dia pipes meter 165.00 200.00 33000 0 0 N 0
85 PWD PWD BLD 2015 19.10 Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured) 19.10.1 25 mm nominal bore each 200.00 20.00 4000 0 0 N 0
86 PWD PWD BLD 2015 19.10 19.10.2 32 mm nominal bore each 224.00 25.00 5600 0 0 N 0
87 PWD PWD BLD 2015 19.10 19.10.3 40 mm nominal bore each 278.00 4.00 1112 0 0 N 0
88 PWD PWD BLD 2015 19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):19.16.125 mm nominal bore each 436.00 10.00 4360 0 0 N 0
89 PWD PWD BLD 2015 19.16.2 32 mm nominal bore. each 510.00 10.00 5100 0 0 N 0
90 PWD PWD BLD 2015 19.44 Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. each 94.00 20.00 1880 0 0 N 0
91 PWD PWD BLD 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank litre 7.30 8000.00 58400 0 0 N 0
92 PWD PWD BLD 2015 19.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc.,(19.5.1)15 mm nominal outer dia .Pipes. meter 133.00 200.00 26600 0 0 N 0
93 PWD PWD BLD 2015 19.5.3 25 mm nominal outer dia .Pipes. meter 213.00 250.00 53250 0 0 N 0
94 PWD PWD BLD 2015 19.11 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete: 19.11.1 15 mm nominal bore each 85.00 50.00 4250 0 0 N 0
95 PWD PWD BLD 2015 19.11 19.11.3 25 mm nominal bore each 117.00 60.00 7020 0 0 N 0
97 PWD PWD BLD 2015 19.11 19.11.5 40 mm nominal each 169.00 2.00 338 0 0 N 0
98 PWD PWD BLD 2015 19.43 Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same : each 125.00 10.00 1250 0 0 N 0
99 PWD PWD BLD 2015 19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:19.14.1Bib cock (400 grams) each 382.00 52.00 19864 0 0 N 0
100 PWD PWD BLD 2015 19.14.4 Piller Cock (400 grams) each 398.00 30.00 11940 0 0 N 0
101 PWD PWD BLD 2015 19.14.7 Angle valve for basin mixer and geyser points (450 grams) each 382.00 30.00 11460 0 0 N 0
102 PWD PWD BLD 2015 19.14.13 Toilet paper holder each 248.00 30.00 7440 0 0 N 0
103 PWD PWD BLD 2015 19.14.14 Soap dish plate each 163.00 30.00 4890 0 0 N 0
104 PWD PWD BLD 2015 19.14.15 Shower rose (revolving type) (150mm) each 269.00 30.00 8070 0 0 N 0
105 PWD PWD BLD 2015 19.14.16 Towel rail (600mm long x 20mm dia) each 338.00 30.00 10140 0 0 N 0
106 PWD PWD BLD 2015 19.14.17 Towel ring (150 mm dia) each 254.00 30.00 7620 0 0 N 0
107 PWD PWD BLD 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. each 51.00 45.00 2295 0 0 N 0
108 PWD PWD BLD 2015 18.29 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. each 599.00 30.00 17970 0 0 N 0
109 PWD PWD BLD 2015 18.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required :18.1.3White Orissa pattern W.C. pan of size 580x440 mm each 2899.00 10.00 28990 0 0 N 0
110 PWD PWD BLD 2015 18.4 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.4.1White pedestal type each 2882.00 10.00 28820 0 0 N 0
111 PWD PWD BLD 2015 18.17 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required 18.17.5White Oval or round size 550x400mm. each 1605.00 15.00 24075 0 0 N 0
112 PWD PWD BLD 2015 18.13 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete:18.13.1Flat back half stall urinal of size 460x380x250mm Flat back half stall urinal of size 460x380x250mm each 1776.00 6.00 10656 0 0 N 0
113 PWD PWD BLD 2015 18.11 Providing and fixing 15 mm nominal bore C.P copper connection pipe with C.P brass nuts collar and PVC bush of approved quality:18.11.2 45 CM length each 239.00 50.00 11950 0 0 N 0
114 PWD PWD BLD 2015 18.25 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.25.1 32 mm dia each 68.50 60.00 4110 0 0 N 0
115 PWD PWD BLD 2015 18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1 75 mm dia pipe. meter 182.00 285.00 51870 0 0 N 0
116 PWD PWD BLD 2015 18.76.2 110 mm dia pipe. meter 267.00 350.00 93450 0 0 N 0
117 PWD PWD BLD 2015 18.76.3 150 mm dia pipe. meter 440.00 200.00 88000 0 0 N 0
118 PWD PWD BLD 2015 18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90°18.77.1.1 75 mm each 113.00 40.00 4520 0 0 N 0
120 PWD PWD BLD 2015 18.77.6 Nahani trap 110x75mm each 90.50 60.00 5430 0 0 N 0
121 PWD PWD BLD 2015 18.78 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.18.78.2 110 mm each 61.00 60.00 3660 0 0 N 0
122 PWD PWD BLD 2015 19.47 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : each 754.00 20.00 15080 0 0 N 0
123 PWD PWD BLD 2015 19.48 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : each 4644.00 10.00 46440 0 0 N 0
124 PWD PWD BLD 2015 19.50 Constructing masonry Chamber 120x120x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : each 11021.00 4.00 44084 0 0 N 0
125 PWD PWD BLD 2015 20.1 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :20.1.2 150 mm diameter meter 262.00 100.00 26200 0 0 N 0
126 PWD PWD BLD 2015 20.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design:(20.2.2 )150 mm diameter S.W. pipe meter 436.00 100.00 43600 0 0 N 0
127 PWD PWD BLD 2015 20.31 Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. each 1709.00 2.00 3418 0 0 N 0
128 PWD PWD BLD 2015 21.17 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable) point 1502.00 2.00 3004 0 0 N 0
129 PWD PWD BLD 2015 21.2 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. 21.2.1 All types of soil 21.2.1.3 150 mm dia. meter 371.00 50.00 18550 0 0 N 0
130 PWD PWD BLD 2015 21.2 21.2.2 Rocky strata including Boulders. 21.2.2.3 150 mm dia. meter 424.00 165.00 69960 0 0 N 0
131 PWD PWD BLD 2015 21.5 Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 21.5.3 150 mm nominal dia meter 1304.00 40.00 52160 0 0 N 0
132 PWD PWD BLD 2015 21.11 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 21.11.3 150 mm dia each 217.00 1.00 217 0 0 N 0
133 PWD PWD BLD 2015 21.16 Providing ISI Mark 32 mm dia G.I. ( B class) riser pipe and M.S. plunger rod in 3 meter length socketed on one end as per IS: 1239 ( Part I) 1990 with up to date amendments and socket as per IS: 2062/1990 up to date amendments. meter 275.00 110.00 30250 0 0 N 0
134 PWD PWD BLD 2015 21.12 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 21.12.3 150 mm clamp. each 1055.00 2.00 2110 0 0 N 0
135 PWD PWD BLD 2015 22.13 Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) cum 115.00 4137.79 475846 0 0 N 0
136 PWD PWD BLD 2015 22.25 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: (22.25.4 )Carpet grass (well developed) sqm 263.00 7490.00 1969870 0 0 N 0
137 PWD PWD BLD 2015 19.9 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete: 19.9.1 15 mm dia. nominal bore meter 131.00 700.00 91700 0 0 N 0
138 PWD PWD BLD 2015 19.9 19.9.3 25 mm dia. nominal bore meter 222.00 340.00 75480 0 0 N 0
139 PWD PWD BLD 2015 19.9 19.9.4 32 mm dia. nominal bore meter 272.00 417.00 113424 0 0 N 0
140 PWD PWD BLD 2015 19.9 19.9.5 40 mm dia. nominal bore meter 308.00 200.00 61600 0 0 N 0
141 PWD PWD BLD 2015 9.39 Providing and fixing in position G.I. barbed wire (93.8gram/m) to concrete/ wooden/ angle iron posts (straight or diagonal) including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete(Cost of posts, struts to be paid for separately) meter 9.40 1500.00 14100 0 0 N 0
142 PWD PWD BLD 2015 9.16 Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.9.16.2Angle-iron frames kg 73.50 1560.81 114720 0 0 N 0
143 PWD PWD BLD 2015 9.19 Providing and fixing in position door shutter made of square/ rectangular hollow steel tube of approved size joint mitred, welded frame with two Nos. intermediate rails, 200mm wide lock rail made of 1.6mm thick M.S. sheet welded to intermediate rail, M.S. grill of approved pattern made of M.S. flat or square or round bars welded to frames and provided M.S. butt hinges, all necessary fitting and finished by filling putty including applying a priming coat of red oxide zinc chromate primer all complete. (To be used in safety door shutters in buildings) kg 93.50 1359.00 127067 0 0 N 0
144 PWD PWD_BRIDGE 2015 2.1 R/Wall Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete.I Ordinary soil (i)Upto 3 m depth cum 146.00 233.64 34111 0 0 N 0
145 PWD PWD_BRIDGE 2015 2.1 II Ordinary rock (not requiring blasting) Add extra 20% in the rates of above items for dewatering (Assessment of dewatering shall be made as per site condition ) cum 246.00 70.09 17242 0 0 N 0
146 PWD PWD_BRIDGE 2015 2.6 Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. A. Using concrete mixer (i) PCC Grade M15 cum 4613.00 404.98 1868173 0 0 N 0
147 PWD PWD_BRIDGE 2015 2.24 Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600. MT 68693.00 3.24 222565 0 0 N 0
148 PWD PWD_BRIDGE 2015 3.8 Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200. meter 321.00 56.70 18200.7 0 0 N 0
149 PWD PWD ROAD 2015 3.2 Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300. cum 95.00 6750.00 641250 0 0 N 0
150 PWD PWD ROAD 2015 3.15 Compacting Original Ground (ii) Compacting Original Ground supporting embankment Loosening, leveling and compacting original ground to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at O.M.C. and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction. cum 28.00 6750.00 189000 0 0 N 0
151 PWD PWD ROAD 2015 3.12 Construction of embankment with Material Obtained from Borrow Pits/Borrow Area (Construction of embankment with approved material/selected soil having C.B.R>5 (unless specified otherwise in the contract) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2) cum 223.00 36750.00 8195250 0 0 N 0
152 PWD PWD ROAD 2015 3.20 DRIAN Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications. meter 2592.00 300.00 777600 0 0 N 0
153 PWD PWD ROAD 2015 3.25 Construction of RCC (ii) Drain/Cover/ChamberConstruction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement, with RCC M-20 cum 4146.00 37.80 156718.8 0 0 N 0
154 PWD PWD ROAD 2015 3.25 Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications. MT 56301.00 2.66 149760.66 0 0 N 0
155 PWD ELECT 2020 1.7.1 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point Point 266.00 21.00 5586 0 0 N 0
156 PWD ELECT 2020 1.7.2 Medium Point Point 424.00 46.00 19504 0 0 N 0
157 PWD ELECT 2020 1.7.3 Long Point Point 588.00 122.00 71736 0 0 N 0
158 PWD ELECT 2020 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 216.00 27.00 5832 0 0 N 0
159 PWD ELECT 2020 1.11.3 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point Point 1350.00 3.00 4050 0 0 N 0
160 PWD ELECT 2020 1.11.4 Extra Long Point I Point 1807.00 8.00 14456 0 0 N 0
161 PWD ELECT 2020 1.11.5 Extra Long Point II Point 2315.00 9.00 20835 0 0 N 0
162 PWD ELECT 2020 1.11.6 Extra Long Point III Point 2825.00 10.00 28250 0 0 N 0
163 PWD ELECT 2020 1.13.1 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 1.5 sq. mm in 20mm conduit Metre 92.00 110.00 10120 0 0 N 0
164 PWD ELECT 2020 1.13.2 3 X 2.5 sq. mm in 20mm conduit Metre 111.00 325.00 36075 0 0 N 0
165 PWD ELECT 2020 1.13.3 6 X 2.5 sq. mm in 25mm conduit Metre 172.00 185.00 31820 0 0 N 0
166 PWD ELECT 2020 1.13.6 3 X 4 sq. mm in 25mm conduit Metre 145.00 315.00 45675 0 0 N 0
167 PWD ELECT 2020 1.13.7 3 X 6 sq. mm in 25mm conduit Metre 182.00 545.00 99190 0 0 N 0
168 PWD ELECT 2020 1.13.8 3 X 10 sq. mm in 25mm conduit Metre 270.00 415.00 112050 0 0 N 0
169 PWD ELECT 2020 5.4.3 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Bell push Each 80.00 1.00 80 0 0 N 0
170 PWD ELECT 2020 5.4.9 Fan regulator (two module size) electronic stepped type moving all rounds Each 223.00 34.00 7582 0 0 N 0
171 PWD ELECT 2020 5.4.19 SP MCB 25 amp Each 250.00 15.00 3750 0 0 N 0
172 PWD ELECT 2020 5.4.20 Ceiling rose 3 pin 5 amp Each 40.00 156.00 6240 0 0 N 0
173 PWD ELECT 2020 5.4.22 Batten/ angle holder Each 41.00 22.00 902 0 0 N 0
174 PWD ELECT 2020 5.4.23 Blank Plate Each 28.00 54.00 1512 0 0 N 0
175 PWD ELECT 2020 5.6 Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification. Each 816.00 4.00 3264 0 0 N 0
176 PWD ELECT 2020 5.7.2 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. Deluxe Each 107.00 1.00 107 0 0 N 0
177 PWD ELECT 2020 5.10 Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification. Each 109.00 34.00 3706 0 0 N 0
178 PWD ELECT 2020 6.1.3 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 1200 mm sweep Each 1697.00 34.00 57698 0 0 N 0
181 PWD ELECT 2020 6.11.2 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 60 cm long Each 40.00 7.00 280 0 0 N 0
182 PWD ELECT 2020 6.16.2 Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 36 watt, size 600 x 600mm Each 2342.00 13.00 30446 0 0 N 0
183 PWD ELECT 2020 6.17.5 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 12 Watt Each 215.00 12.00 2580 0 0 N 0
184 PWD ELECT 2020 6.19.3 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 watt {4 feet} Each 443.00 93.00 41199 0 0 N 0
185 PWD ELECT 2020 6.28.8 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 90 watt Each 5531.00 5.00 27655 0 0 N 0
186 PWD ELECT 2020 6.29.10 Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 250 watt Each 15972.00 32.00 511104 0 0 N 0
187 PWD ELECT 2020 7.11.6 Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 300 amps Each 797.00 3.00 2391 0 0 N 0
188 PWD ELECT 2020 7.19.2 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. Above 300 mm and upto 450 mm deep sqm 7525.00 3.50 26337.5 0 0 N 0
189 PWD ELECT 2020 7.21.3 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 300 amp (40x5mm) Metre 2659.00 3.00 7977 0 0 N 0
190 PWD ELECT 2020 9.1.3 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA Each 2385.00 8.00 19080 0 0 N 0
191 PWD ELECT 2020 9.1.24 4 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 35KA Each 6378.00 2.00 12756 0 0 N 0
192 PWD ELECT 2020 9.1.35 4 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 50KA Each 20001.00 2.00 40002 0 0 N 0
193 PWD ELECT 2020 9.4.4 Supplying and fixing on surface/ recess following way, 415 volts TPN MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 4 way, Double door Each 1716.00 8.00 13728 0 0 N 0
194 PWD ELECT 2020 9.4.5 6 way, Double door Each 2038.00 2.00 4076 0 0 N 0
195 PWD ELECT 2020 9.10.1 Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps Each 151.00 46.00 6946 0 0 N 0
196 PWD ELECT 2020 9.12.2 Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps Each 411.00 8.00 3288 0 0 N 0
197 PWD ELECT 2020 9.16.3 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps Each 1275.00 10.00 12750 0 0 N 0
199 PWD ELECT 2020 9.23 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as per specification. Each 7.00 44.00 308 0 0 N 0
200 PWD ELECT 2020 10.6.4 Providing and fixing metal clad, 4 pole, on load change over switch unit (without sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately) 315 amps Each 14411.00 1.00 14411 0 0 N 0
201 PWD ELECT 2020 10.15.4 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 315/5 amps Each 356.00 3.00 1068 0 0 N 0
202 PWD ELECT 2020 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 94.00 6.00 564 0 0 N 0
203 PWD ELECT 2020 10.23 Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification. Each 1201.00 2.00 2402 0 0 N 0
204 PWD ELECT 2020 12.3 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) Set 6209.00 6.00 37254 0 0 N 0
205 PWD ELECT 2020 12.4 Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification. Metre 77.00 100.00 7700 0 0 N 0
206 PWD ELECT 2020 12.8 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as per specification. Metre 528.00 20.00 10560 0 0 N 0
207 PWD ELECT 2020 14.2.4 Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 110 mm outer dia Metre 355.00 150.00 53250 0 0 N 0
208 PWD ELECT 2020 15.3.17 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 150 sq. mm. Metre 484.00 150.00 72600 0 0 N 0
209 PWD ELECT 2020 15.23.19 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 185 sq. mm (50 mm) Each 385.00 2.00 770 0 0 N 0
211 PWD ELECT 2020 15.28.3 Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. . 16 sq. mm Each 19.00 32.00 608 0 0 N 0
213 PWD ELECT 2020 15.29.1 Supplying, fixing and cramping suitable size and all type Copper ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. . 6 sq. mm Each 21.00 64.00 1344 0 0 N 0
215 PWD ELECT 2020 23.3.2 Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 1.5 HP, single phase Each 17589.00 1.00 17589 0 0 N 0
216 PWD ELECT 2020 23.6.2 Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 50 mm outer dia Metre 118.00 200.00 23600 0 0 N 0
217 PWD ELECT 2020 23.7.4 Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 50 mm dia. Each 1058.00 1.00 1058 0 0 N 0
218 PWD ELECT 2020 23.11 Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set Each 4030.00 1.00 4030 0 0 N 0
219 PWD ELECT 2020 23.12 Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification. Metre 291.00 1.00 291 0 0 N 0
220 PWD ELECT 2020 23.13 Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification Each 388.00 1.00 388 0 0 N 0
221 PWD ELECT 2020 23.14.3 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 3x4.0 sqmm Metre 90.00 250.00 22500 0 0 N 0
222 PWD ELECT 2020 23.15.4 Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification. 3x6.0 sqmm Each 450.00 2.00 900 0 0 N 0
223 PWD ELECT 2020 23.16 Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp. Metre 16.00 205.00 3280 0 0 N 0
224 PWD ELECT 2020 30.1 Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification. cum 168.00 27.00 4536 0 0 N 0
225 PWD ELECT 2020 6.29.5 Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 100watt Each 6288.00 8.00 50304 0 0 N 0
228 PWD ELECT 2020 6.103 Supplying, installation, testing and commissioning of Day/Night sensor 220 - 240 volt AC for lighting purpose of IP 65 wattage rating upto 100 Watts as per the specification Each 558.00 4.00 2232 0 0 N 0
229 PWD ELECT 2020 7.19.1 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. Upto 300 mm deep sqm 6818.00 4.00 27272 0 0 N 0
230 PWD ELECT 2020 7.20.1 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 100 amp (20x5mm) Metre 717.00 4.80 3441.6 0 0 N 0
231 PWD ELECT 2020 9.11.2 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps Each 148.00 12.00 1776 0 0 N 0
232 PWD ELECT 2020 9.16.3 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps Each 1275.00 12.00 15300 0 0 N 0
233 PWD ELECT 2020 10.14.2 Providing and fixing 4 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 40 amps Each 1422.00 12.00 17064 0 0 N 0
234 PWD ELECT 2020 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 94.00 12.00 1128 0 0 N 0
235 PWD ELECT 2020 10.22.1 Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. Digital type Each 1901.00 4.00 7604 0 0 N 0
236 PWD ELECT 2020 12.3 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) Set 6209.00 8.00 49672 0 0 N 0
237 PWD ELECT 2020 12.5 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification. Metre 513.00 48.00 24624 0 0 N 0
238 PWD ELECT 2020 14.2.2 Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 75 mm outer dia Metre 174.00 750.00 130500 0 0 N 0
239 PWD ELECT 2020 15.2.23 Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 4 x 16 sq. mm. Metre 205.00 750.00 153750 0 0 N 0
240 PWD ELECT 2020 15.15.2 Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, unarmoured, copper conductor control /power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification and IS: 694 (2010). 4 x 1.5 sq. mm Metre 125.00 64.00 8000 0 0 N 0
242 PWD ELECT 2020 15.28.3 Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. . 16 sq. mm Each 19.00 48.00 912 0 0 N 0
243 PWD ELECT 2020 19.20 Supplying erection testing and commissioning of hot dipped galvanised (single dip 86 micron) 20 metre High mast pole on existing RCC foundation with all accessories and equipments, detailed as below to withstand wind pressure upto 180km/hr and minimum following specifications: a) HM shaft made of not more than 2 sections of suitable lengths with telescopic stressfit joints between sections without any circumpherencial welding, sheet thickness 4mm top and bottom sections, nominal dia 460mm on bottom and 150 mm on top, base plate 30mm thick 670mm dia, PCD of foundation bolts 650mm. b) Double drum winch for lowering & raising of lantern carriage on high mast with operatable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & raising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong. k) Anchor plate of size 750x750x6mm, tem-plates 3mm thick, GI foundation bolts 12 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately) Each 266510.00 4.00 1066040 0 0 N 0
244 PWD ELECT 2020 19.23 Designing and providing suitable and approved size RCC foundation for 12-30 mere high mast including seel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as per specification cum 5219.00 32.00 167008 0 0 N 0
245 PWD ELECT 2020 30.2 Earth work in soft rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling with excavated soil in trench / pit to ground level complete as per specification cum 210.00 40.00 8400 0 0 N 0
246 PWD ELECT 2020 15.14.2 Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, copper conductor control /power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification and IS: 694 (2010). 4 x 1.5 sq. mm Metre 133.00 200.00 26600 0 0 N 0
247 PWD ELECT 2020 24.4 Installation of split type Inverter/Non Inverter Air Conditioner unit, cooling unit on wall inside and condensing unit on out side wall/ ceiling/ floor at desired locations with existing standard length of copper piping with insulation and power cable including providing and fixing necessary good quality powder coated MS frame etc complete as per specification. (Extra length of copper piping and power cable shall be paid extra on linear basis) Each 2110.00 3.00 6330 0 0 N 0
248 PWD ELECT 2020 24.7.2 Supply and fixing of approved make wall mounting type voltage stabilizer with input volts 160-250, output volts 200-240 volts and double step relay on desired location with necessary fixing material including connection etc complete as per specification. 5 KVA Each 4367.00 3.00 13101 0 0 N 0
249 PWD ELECT 2020 24.10.1 Supply, connecting and fixing extra length of copper piping for split type air conditioners of following dia and approved quality with insulation sleave etc complete as per specification 5/8 " Metre 375.00 10.00 3750 0 0 N 0
251 PWD ELECT 2020 24.11 Supplying and fixing good quality powder coated MS frame for installation of out door unit of split type Air Conditioner at desired location with atleast 6 nos steel fastners etc complete as per specification Set 435.00 3.00 1305 0 0 N 0
252 PWD ELECT 2020 24.12 Supplying, connecting and fixing 15mm dia PVC flexible drain pipe (reinforced with nylon threads) in drain outlet of split type air conditioners etc complete as per specification Metre 14.00 10.00 140 0 0 N 0
253 PWD ELECT 2020 24.20.8 Supplying of approved make Hiwall split Inverter type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 5 metre of copper piping with insulation etc complete as per specification: 1.5 Ton split type Inverter AC {5 Star} Each 45340.00 1.00 45340 0 0 N 0
254 PWD ELECT 2020 24.20.9 2.0 Ton split type Inverter AC {5 Star} Each 55830.00 2.00 111660 0 0 N 0
255 PWD ELECT 2020 24.23.3 Supplying, installation, testing and commissiong of following size drinking water cooler storage type ISI marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material- stainless steel {grade AISI 304} with thickness>= 0.8 mm, with PUF insulation including all accessories connection etc complete as per specification. 150/150 Ltrs/hr Each 47568.00 1.00 47568 0 0 N 0
256 PWD ELECT 2020 24.24.2 Supplying, installation, testing and commissiong of following capacity of RO purification system with UF/UV/TDS controler and UV lamp {IS 14724 Ultra voilet disinfection} and minimum three stage purification, automatic on/off, output water conferming standard IS 10500 with inbuild storage tank including all accessories connection etc complete as per specification. 50 Ltrs/hr output capacity Each 39021.00 1.00 39021 0 0 N 0
257 PWD ELECT 2020 24.25.3 Supplying and fixing of approved make Tower Air Conditioner unit with cooling unit and condensing unit with copper coil including standard length of upto 3 metre of copper piping with insulation etc complete as per specification. 4.0 TR Each 95048.00 10.00 950480 0 0 N 0
258 PWD ELECT 2020 24.33 Supply, Installation , testing and commisioning of 5000 Cubic meter per hour Jumbo Plastic Body Cooler Including Floor Standing caster wheels ,Synthetic Honeycomb pads , Sump Tank Capacity (minimum) 100 Litres , minimum Thickness of Body of the Plastic Cooler should be 2 millimeter,Drain Plug material Plastic / Rubber,Fan Size 450 mm ,Blade Material High Impact Plastic ,Minimum number of steps for fan speed control should be 3 , Power Factor 0.9 or Better,Thickness of Synthetic Honeycomb pads Filter should be 15 mm or above, Location of the Water Collecting Chamber At the Bottom , ,Minimum length of connecting cable with 3-pin moulded Plug Top 5/6 Amps rating should be 2.5 meter etc complete with all fitting accessorries and supports as required. Each 14911.00 2.00 29822 0 0 N 0
259 PWD ELECT 2020 25.51.2 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as per specification : 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt. 317.00 100.00 31700 0 0 N 0
260 PWD ELECT 2020 25.51.4 15.9 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt. 808.00 100.00 80800 0 0 N 0
261 PWD ELECT 2020 25.55.1 Supplying, laying, fixing and installation of rigid PVC drain piping of 6 KG/sqcm, duly insulated with 6/9 mm thick nitrile rubber pipe section, complte with all necessary fitting such as elbows, tees, reducers, serviceable "P" traps etc. and supports such as clamps etc. complate as per specifications. 25 MM DIA Rmt. 150.00 100.00 15000 0 0 N 0
262 PWD ELECT 2020 1.15.2 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 25 mm Metre 53.00 200.00 10600 0 0 N 0
263 PWD ELECT 2020 26.1 Suppying , installation , testing and commissioning of Fire alarm Control panel (UL Listed) suitable for 50 addressable points (Detector & Devices). Comprising of the following system components: Operating units, Periphery boards, Power supplies,System enclosures, with battery backup 24hours and 30minutes, Each 95892.00 1.00 95892 0 0 N 0
264 PWD ELECT 2020 26.9 Suppying , installation , testing and commissioning of Intelligent Addressable Multi-sensor Smoke detector: Multi-criteria addressable fire detector that incorporates photoelectric and thermal sensors,Polarity insensitive utilizing SureWireTM technology,Tri-color detector status LED with 360° viewing,Field-selectable application profiles,Superior EMI immunity, Remote sensitivity-measurement capability,Automatic environment compensation,UL Listed and ULC Listed; FM Approved. Each 2986.00 24.00 71664 0 0 N 0
265 PWD ELECT 2020 26.11 Suppying , installation , testing and commissioning of Intelligent Addressable Type Manual Call Point: Intelligent Manual Fire Alarm Box is constructed of durable, molded and polycarbonate material that is matte finished in red with raised white lettering Single-action,Pull-down lever is down, until manually reset,Polarity insensitive via SureWireTM technology Each 4317.00 5.00 21585 0 0 N 0
266 PWD ELECT 2020 26.12 Suppying , installation , testing and commissioning of Short circuit Isolator Base: Local light-emitting diode (LED) indicator UL 864 9th Edition Listed and ULC Listed; FM Approved Each 2149.00 4.00 8596 0 0 N 0
267 PWD ELECT 2020 26.13 Suppying, installation, testing and commissioning of Conventional Type Hooter with Strobe: Hooter with Strobe. Wall Mount models feature field selectable candela settings of 15/30/75/110cd and 135/185cd. Ceiling Mount models feature field selectable candela settings of 15/30/75/95cd and 115/177cd. UL Listed, ULC, FM approved. NFPA Compliant. Red. Each 5084.00 3.00 15252 0 0 N 0
268 PWD ELECT 2020 26.15 Suppying , installation , testing and commissioning of Intelligent Addressable Relay control module for Hooter Interfacing and supervising normally open (N.O) or normally closed (N.C) contacts,Integral single-pole, double-throw (SPDT) relay (up to 4 amps) ,Multi-color light-emitting diode (LED) indicates system status, UL Listed & ULC Listed; FM Approved Each 4277.00 3.00 12831 0 0 N 0
269 PWD ELECT 2020 26.16 Suppying , installation , testing and commissioning of 2 core x 1.5 sq.mm Armoured FRLS cable Metre 509.00 200.00 101800 0 0 N 0
270 PWD ELECT 2020 26.17.1 Supply and erecting of following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. ABC Fire Extinguisher 9KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 6A, 144B. With all accessories. Each 5468.00 6.00 32808 0 0 N 0
271 PWD ELECT 2020 26.17.5 CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve Each 8222.00 2.00 16444 0 0 N 0
272 PWD ELECT 2020 1.15.2 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 25 mm Metre 53.00 160.00 8480 0 0 N 0
273 PWD ELECT 2020 3.14 Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification metre 19.00 250.00 4750 0 0 N 0
274 PWD ELECT 2020 14.2.1 Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 63 mm outer dia Metre 124.00 450.00 55800 0 0 N 0
275 PWD ELECT 2020 19.7.1 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 6 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 600mm long Each 7365.00 6.00 44190 0 0 N 0
276 PWD ELECT 2020 19.11.4 Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 6 metre high Each 805.00 6.00 4830 0 0 N 0
277 PWD ELECT 2020 19.12 Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification. cum 5219.00 3.00 15657 0 0 N 0
278 PWD ELECT 2020 27.11 Supplying , installation , testing and commissioning of 4 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67 , IK 10) , 1/3” 4MP PS CMOS Image Sensor, H.265 and H.264 triple-stream encoding, WDR(120dB), Day/Night Support, UL ,CE FCC Certified as per the specifications. Each 6353.00 6.00 38118 0 0 N 0
279 PWD ELECT 2020 27.12 Supplying , installation , testing and commissioning of 2 MP DOME Camera weather & dust proof IP based Fixed Lens day/night Camera (IP66) 2Megapixel CMOS Image Sensor,H.265 / H.264 triple-stream encoding , WDR(120dB), Day/Night UL, CE, FCC Certified as per the specifications. Each 5094.00 9.00 45846 0 0 N 0
280 PWD ELECT 2020 27.17 Supplying , installation , testing and commissioning of 2 MP PTZ Camera of weather & dust proof IP based Dome PTZ (Pan Tilt & Zoom) true day& night camera ,1/2.8” 2MP PS CMOS Image sensor, Max. 50/60fps@1080P,Color: [email protected]; [email protected] (IR on), Powerful 45x (3.95~177.7 mm) Optical and 16x Digital zoom, WDR(120dB), 3D DNR, Day/Night(ICR),Defog, ROI, EIS, AGC, BLC, HLC, Support Starlight Function, Up to 300 presets, auto scan, 8 tour, 5 pattern, auto pan, Tripwire, Intrusion, Abandoned/Missing , Face Detection, Heat Map, IR Range of 200 Mtr., Max 300° /s pan speed, 360° endless pan rotation, Built-in 7/2 alarm in/out,Micro SD card 256GB, IP67, IK10, Support PoE+, UL, CE ,FCC certified as per the specifications. Each 66806.00 1.00 66806 0 0 N 0
281 PWD ELECT 2020 27.21 Supplying , installation , testing and commissioning of 32 Channel NVR 4 Sata port Up to 32 channel IP camera input , Max 200Mbps incoming bandwidth ,Smart H.265+/H.265/Smart H.264+/H.264 dual codec decoding , Up to 8MP resolution preview and playback , Support 4 SATA HDDs up to 6 TB each, 2 USB(1 USB3.0, 1 USB2.0) , 1 HDMI / 1 VGA simultaneous video output , ONVIF Version 2.4 conformance , Alarm In / out 16/4 , Two way talk 1 Channel Input, 1 Channel Output RCA , 2 RJ-45 port (10/100/1000Mbps), 1 RS485, 1 RS232 as per the specifications. Each 26449.00 1.00 26449 0 0 N 0
282 PWD ELECT 2020 27.25 Supplying , installation , testing and commissioning of 4 Port POE Switch 10/100 4 Port PoE with 2 10/100 Mbps Uplink ,Power Budget 60 Watt , Max 30 watt per port as per the specifications. Each 2773.00 4.00 11092 0 0 N 0
283 PWD ELECT 2020 27.27 Supplying , installation , testing and commissioning of 8 Port Giga PoE Switch 10/100/1000 8 Port with 2 GigaJ 45 uplink, PoE switch ,AI Extend , AI Vlan as per the specifications. Each 6711.00 2.00 13422 0 0 N 0
284 PWD ELECT 2020 27.39 Supplying , installation , testing and commissioning of 8 TB Surveillance Hard disk drive Complete as required Each 21655.00 2.00 43310 0 0 N 0
285 PWD ELECT 2020 27.45 Supplying , installation , testing and commissioning of 6U Indoor Rack Wallmount 6U 450D With Front Glass Door Lock & Key 550 6U - loaded with cable manager + PDU + Fan complete as required. Each 3507.00 3.00 10521 0 0 N 0
286 PWD ELECT 2020 27.49.2 Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification. 43 inch Each 43178.00 1.00 43178 0 0 N 0
287 PWD ELECT 2020 27.93 Supplying and laying Of CAT 6 Outdoor Cable Solid Annealed Bare Copper Conductor. LLD PE/PE Sheath Material For Video Power and Audio Communication With Laying Cable Underground With Suitable Size PVC Conduit/Casing Capping and Other Accessories as per requirement. P.Mtr. 103.00 450.00 46350 0 0 N 0
Say Rs:- 754.86 Lacs
Sub Engineer Sub Divisional Officer Executive Engineer
P.W.D (B/R) P.W.D.(B/R) Sub Division P.W.D.(B/R) Division
Manendragar Manendragarh Manendragarh
Department Name Code SOR Name SOR UOM Name UOM Code false30820
Bastar Urban Public Transport Society (BSTUPTS) BSTUPTS WRD WRD Percentage %
Bilaspur Smart City Limited(BSCL) BSCL PHE PHE Per mile %O
Bilaspur Urban Public Transport Society (BSPUPTS) BSPUPTS ELECTRIC ELECT 1 Job 1 Job
Chhattisgarh Department of Agriculture (CGDA) CGDA PHED PHED1 1000 no. 1000 no.
CHHATTISGARH ENVIRONMENT CONSERVATION BOARD(CECB) CECB RES_BUILDING RESBDG 1000No. 1000No.
Chhattisgarh Handicraft Board (CGHCB) CGHCB PMGSY SOR PMGSY Print 123
Chhattisgarh High Court, Bilaspur (CGHC) CGHC NON SOR NS Per Diem Rate 1234
Chhattisgarh Housing Board (CGHB) CGHB BRIDGE PWD_BRIDGE MAN DAYS 12345
Chhattisgarh Infotech Promotion Society (CHiPS) CHiPS PWD BUILDLING PWD BLD PRINT 678
Chhattisgarh Kamdhenu Vishwavidyalaya(CGKV) CGKV PWD ROAD PWD ROAD Siemens Per meter A/V
Chhattisgarh Medical Services Corporation Ltd. (CGMSC) CGMSC Acre ACR
Chhattisgarh Police Housing Corporation Ltd (CGPHC) CGPHC Price Should be quoted as per SKU in Aneexure-I of Tender Document APT
Chhattisgarh Railway Corporation Ltd(CRCL) CRCL Activity unit AU
Chhattisgarh Rajya Beej Evam Krishi Vikas Nigam (CGRBEKVN) CGRBEKVN Bag BAG
Chhattisgarh Road Development Corporation Limited(CGRDC) CGRDC Batch Batch
Chhattisgarh State Civil Supplies Corp. Limited (SCSC) SCSC Book BK
Chhattisgarh State Co-Operative Marketing Federation Limited(CGMARKFED) CGMARKFED Box BOX
Chhattisgarh State Cooperative Dairy Federation Ltd.(CGCDF) CGCDF Gallons per hour (US) BPH
Chhattisgarh State Industrial Development Corporation (CSIDC) CSIDC Bottle BT
Chhattisgarh State Mandi Board (CGSMB) CGSMB Cubic sentimeter /second C3S
Chhattisgarh State Minor Forest Produce-Trading & Development Co-Operative Federation Ltd (CGMFPFED) CGMFPFED Canister CAN
Chhattisgarh State Power Distribution Company Limited (CGSPDCL) CGSPDCL Carton CAR
Chhattisgarh State Power Generation Company Limited (CGSPGCL) CGSPGCL Cubic Centimeter CCM
Chhattisgarh State Power Transmission Company Limited (CGSPTCL) CGSPTCL Cubic decimeter CD3
Chhattisgarh State Renewable Energy Development Agency(CREDA) CREDA Centiliter CL
Chhattisgarh State Warehousing Corporation (CGSWC) CGSWC cm cm
Chhattisgarh Text Book Corporation (CGTBC) CGTBC Centimeter CM
CHHATTISGARH TOURISM BOARD(CGT) CGT Square centimeter CM2
Department of Animal Husbandry and Dairy (DAHD) DAHD coils coils
Department of Home Guard and Civil Defence Chhattisgarh (HGCD) HGCD COILS Coils
Department of Panchayat and Social Welfare (DPSW) DPSW Copies Copies
Department of School Education (DSE) DSE Crate CRT
Department of Technical Education (DTE) DTE Case CS
Department of Women and Child Development(WCD) WCD Cu.Mtr. Cu.Mtr.
Directorate Horticulture and Farm Forestry, Chhattisgarh(DHF) DHF cubic feet cubic feet
Directorate of Fisheries (DF) DF cubic feet (CFT) cubic feet (CFT)
Directorate of Sports and Youth Welfare(DSYW) DSYW cum cum
DISTRICT POLICE KORBA(DPK) DPK cum.km cum.km
Durg-Bhilai Urban Public Transport Society (DBUPTS) DBUPTS Days DAY
Food and Drug Administration (FDA) FDA Degree DEG
Health Department (HD) HD DFLT DFLT
Indira Gandhi Krishi Vishwavidyalaya (IGKV) IGKV Decimeter DM
Korba Urban Public Transport Society (KRBAUPTS) KRBAUPTS Drum DR
Koriya Urban Public Transport Society (KRYAUPTS) KRYAUPTS Dozen DZ
Lauh Purush Sugar Plant, Pandariya(LSPSSKM) LSPSSKM EACH EA
Mineral Resources Department -Mining (MRD) MRD each each
Naya Raipur Development Authority (NRDA) NRDA each additional floor each additional floor
Panchayat and Rural Development (PARD) PARD Each Courty Each Court
Public Health Engineering Department (PHED) PHED each cut each cut
Public Works Department (PWD) PWD each test each test
Raigarh Urban Public Transport Society (RIGUPTS) RIGUPTS each tree guard each tree guard
Raipur Collectorate (RC) RC each tree guard each tree guard
Raipur Development Authority (RDA) RDA Each box EB
Raipur Smart City Limited(RSCL) RSCL Enzyme Units / Milliliter EML
Raipur Urban Public Transport Society (RUPTS) RUPTS Each TAPE ET
Rajnandgaon Urban Public Transport Society (RNDGUPTS) RNDGUPTS Enzyme Units EU
Rashtriya Madhyamik Shiksha Abhiyan(RMSA) RMSA Fluid Ounce US FOZ
Rural Engineering Services (RES) RES Feet FT
Sarguja Urban Public Transport Society (SUPTS) SUPTS Square foot FT2
State Urban Development Agency (SUDA) SUDA Cubic Foot FT3
Urban Administration and Development Department (UADD) UADD Gigajoule FY
Water Resources Department (WRD) WRD Gram G
Zila Panchayat Raipur(ZPR) ZPR gram act.ingrd /liter G/L
Gram act.ingrd. GI
Gram /liter GLI
Gram /square meter GM2
Gram/Cubic meter GM3
Gallons per mile (US) GPM
hectare hectare
I/O Point I/O Point
Indian Rupees INR
Joule /kilogram JKG
Kilogram act.ingrd KAI
Kilogram /cubic decimeter KD3
Kilogram/Mol KGM
Kilogram /Second KGS
Kilogram / cubic meter KGV
kg act.ingrd /kg KIK
Kilojoule/kilogram KJK
Kilojoule/Mol KJM
Square kilometer KM2
Kilometer/hour KMH
Kelvin/Minute KMN
Kelvin /Second KMS
Kilonewton per square meter KNM
Kilovoltampere KVA
Liter per 100 km LHK
Liter /Minute LMI
Liter /Molsecond LMS
Liter Per hour LPH
lumpsump lumpsump
1/square meter M-2
Mol per cubic meter M:M
Megawatt hours M..
Meter /Hour M/H
Mol per liter M/L
Meter /second M/S
Square meter M2
Square meter/Coat M2C
Square meter/second M2S
Cubic meter /Hour M3H
Cubic meter/second M3S
Man days Man days
Man-Month Man-Month
Manmonth Manmonth
Milligram/liter MGL
Milligram /cubic meter MGQ
Square mile MI2
Microsecond MIS
Milliliter act.ingr. MLI
Square millimeter MM2
Cubic millimeter MM3
Millinewton/meter MNM
Miles per gallon (UG) MPG
Millimol per liter MPL
Millipascal seconds MPS
Meter/second squared MS2
Microsiemens per centimeter MSC
Newton/meter NM
Newton/Square millimeter NMM
one RCC jaali tree guard one RCC jaali tree guard
one RCC jaali tree guard one RCC jaali tree guard
P.cumt. P.cumt.
P.Point P.Point
Per Running Meter Per Box P.R.M.P.BOX
p.sq.mtr p.sq.mtr
P/sq.Mt. P/sq.Mt.
Pascal second PAS
Megavoltampere PCT
per cm height per letter per cm height per letter
per cm height per letter per cm height per letter
per cubic centimeter per cubic centimeter
Per Diem Rate Per Diem Rate
Per Km. Per Km.
per letter per letter
per month per month
Per mtr Per mtr
Per packet PER PACKET
Per person PER PERSON
Per piece PER PIECE
Per Plants Per Plants
per pouch per pouch
Per running feet PER RUNNING FEET
Per Set Per Set
Per Sqr Km Per Sqr Km
Per square km Per square km
Per Tanker Per Tanker
per test per test
Per thousand PER THOUSAND
per tonne per tonne
per tonne capacity per tonne capacity
Per unit PER UNIT
per.mtr per.mtr
PER SQUARE FEET PERSQF
Parts per billion PPB
Parts per million PPM
Per Person Per Month Per Shift PPPMPS
Parts per trillion PPT
Number of persons PRS
Pound Per Sq inch PSI
Pint, US liquid PT
Per Ton Per KM PTPK
Quart, US liquid QT
quintal quintal
Gramm/cubic centimeter RHO
Running Meter Rmt
RUNNING METRE RMT
Square feet Sq.Ft
Square Meter sqm
Thousand Hours THR
Ton/Cubic meter TOM
DEFAULT UNIT DESCRIPTION XXX
Square Yard YD2
Microgram /liter µGL
Microgram /cubic meter µGQ
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
6729407556750375479_194543_Annexure E.doc
NIT • 0.04 MB
3830073501338680426_194543_FORM A.doc
NIT • 0.15 MB
7730704086377026759_194543_NEW NIT.doc
NIT • 0.32 MB
6346335264030648598_194543_NEW PQ.doc
NIT • 0.27 MB
6229657517126728083_194543_Notice.doc
NIT • 0.10 MB
2930212204874922598_194543_Approved Make List EM.xlsx
BOQ • 0.01 MB
4966609509807161090_194543_BOQ.xlsx
BOQ • 0.08 MB
Download all tender documents and submit your bid