Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹2.5 L
Closing Date
5 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
WORKS
13 conditions · 2 needing a document upload
As per GCC 10(b):- The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; Where: V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Technical Eligibility Criteria: - As mentioned in GCC 2022 clause 10(a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. The work is executed for similar nature of work as under: Repair / Rehabilitation / Overhauling / AMC / Supply, erection, testing & commissioning of Central AC Unit / Window AC / Package AC units / Air Conditioning Duct / Split type AC units / Water Cooler etc. The work must have been carried out in any of the following organizations: a) Central Government departments or State Government departments. b) Central government PSUs or State Government PSUs. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
8 conditions · 6 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Certificate stating that the tenderer/s are not liable to be disqualified and all their statements / documents submitted along with bid are true and factual as per Annexure-V (Ref: PARA 6.1 of Part-I, Instruction to Tenderers(ITT) at Page Nos.7 & 33-34 of GCC April 2022).
TENDER FORM (First Sheet) (Ref: Page Nos.9 & 10 of GCC April 2022 and correction slip 7).
In case the tenderer is other than Joint Venture (JV) firm, tenderer has to submit all the documents as mentioned below (Ref: Clause 14 (ii) (a) to (c), (e) to (g), (iv) & 18.10 of TENDER FORM (Second Sheet) at Page Nos.17-18 of GCC April 2022
6.Tenderers shall note that the submission of other following supporting documents, is important and they shall ensure the same at the time of on line bidding of tender. However Railways may seek clarifications / details / documents in this regard: (a) Copy of Vendor Mandate Form as per Appendix-VII of the Tender Document. All Payments to the agency [Including the refund of the Earnest Money (EMD) of the unsuccessful bidder] will be remitted through NEFT. The Tenderer is required to declare Bank details and A/C No. etc. in Vendor Mandate Form. (b) Copy of the complete details of the firm as per Appendix-I of the Tender/Technical Bid Document, to which all correspondences shall be made by the Railway. (c) Copy of Goods and Services Tax (GST) Registration Certificate containing GST Registration Number. (d) Copy of certificate by tenderer for site visit & familiarization as per Appendix-VI of the Tender/Technical Bid Document. (e) Copy of the list of the Personnel / Organization of the tenderer on hand and proposed to be engaged for this tender as per Appendix-IV of the Tender/Technical Bid Document (Ref: CP/23/23). (f) Copy of list of the plants & machinery of tenderer available on hand and proposed to be inducted & hired for this tender as per Appendix-V of the Tender/Technical Bid Document (Ref: CP/23/24).
Electrical License
Supervisor Licences
GST,PAN CARD ETC.
Design, Supply, Erection, testing and commissioning of VRF system at various service buildings in Kalyan Under Kalyan Segrigation of Long distance train of Mumbai Division of Central Railway.
LCF-DR-AC-504-2025-23~CR
LCF-DR-AC-504-2025-23
Open
Works - General
6 Months
Mumbai, Maharashtra
₹0
₹2.5 L
5 Mar 2026
10 Feb 2026
19 Feb 2026
141 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,03,75,867 | ||
| — | 2.00 | — | — | ||
| Supply, Lifting Shifting, Erection, Installation, Testing and Commissioning of Outdoor Units of VRF system with Air-cooled condenser suitable for operation at ambient temperature up to 56°C,highpressure Scroll Compressors with hermetic motor, assembled and wired in a singlepackagecomplete, starting controls, safety controls, operating controls and with fullfeaturemicrocomputer based controller with programming/diagnosis facility. One/All Compressorsshall beinverter type based on manufacturer's technology. The system should deliver rated capacity atambient up to 43°C DB. (a) 10 HP Outdoor Unit | — | — | — | 4,27,114 | |
| — | 2.00 | — | — | ||
| Lifting Shifting, Erection, Installation, Testing and Commissioning of Outdoor Units ofVRFsystem with Air-cooled condenser suitable for operation at ambient temperature up to 56°C,highpressure Scroll Compressors with hermetic motor, assembled and wired in a singlepackagecomplete, starting controls, safety controls, operating controls and with fullfeaturemicrocomputer based controller with programming/diagnosis facility. One/All Compressorsshall beinverter type based on manufacturer's technology. The system should deliver rated capacityatambient up to 43°C DB. (a) 10 HP Outdoor Unit | — | — | — | 47,458 | |
| — | 3.00 | — | — | ||
| Supply of Outdoor Units of VRF system with Aircooled condenser suitable for operation at ambient temp. upto 56C, high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with programming / diagnosis facility. One / All Compressors shall be invertor type based on manufacturer's technology. The system should deliver rated capacity at ambient upto 43°C DB.(b) 12 HP Outdoor Unit | — | — | — | 6,07,236 | |
| — | 3.00 | — | — | ||
| "Lifting Shifting, Erection, Installation, Testing and Commissioning of Outdoor Units of V R F system with Air-cooled condenser suitable for operation at ambient temp. upto 56C, high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with programming / diagnosis facility. One / All Compressors shall be invertor type based on manufacturer's technology. The system should deliver rated capacity at ambient upto 43°C DB. (b) 12 HP Outdoor Unit " | — | — | — | 67,470 | |
| — | 4.00 | — | — | ||
| Supply of 20 HP Outdoor Units of VRF system with Air-cooled condenser suitable for operation at ambient temperature up to 56°C, high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with programming/diagnosis facility. One/All Compressors shall be invertor type based on manufacturer's technology. The system should deliver rated capacity at ambient up to 43°C DB. | — | — | — | 12,58,736 | |
| — | 4.00 | — | — | ||
| Lifting Shifting, Erection, Installation, Testing and Commissioning of 20 HP Outdoor Units of VRF system with Air cooled condenser suitable for operation at ambient temperature up to 56°C, high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with programming/diagnosis facility. One/All Compressors shall be invertor type based on manufacturer's technology. The system should deliver rated capacity at ambient up to 43°C DB. | — | — | — | 52,176 | |
| — | 3.00 | — | — | ||
| Supply of 22 HP Outdoor Units of VRF system with Air-cooled condenser suitable for operation at ambient temperature up to 56°C, high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with programming/diagnosis facility. One/All Compressors shall be invertor type based on manufacturer's technology. The system should deliver rated capacity at ambient up to 43°C DB. | — | — | — | 10,11,459 | |
| — | 3.00 | — | — | ||
| Lifting Shifting, Erection, Installation, Testing and Commissioning of 22 HP Outdoor Units of VRF system with Air cooled condenser suitable for operation at ambient temperature up to 56°C, high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with programming/diagnosis facility. One/All Compressors shall be invertor type based on manufacturer's technology. The system should deliver rated capacity at ambient up to 43°C DB. | — | — | — | 96,534 | |
| — | 3.00 | — | — | ||
| Supply of 28 HP Out Door Units suitable for VRF System. The system shall comprise of Outdoor Units with Air cooled condenser suitable for operation at ambient temperature of 56°C, delivering rated capacity at 43C without deration, high pressure Rotary / Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller and programming / diagnosis facility as per Railway Requirement. All Compressors shall be inverter type based on manufacturer's technology. The unit is to be given shipped with full operating charge of refrigerant and oil. Air cooled Condensor, refrigeration-piping controls, first charge of refrigerant etc. The Refrigerant used shall be any CFC free gas R410A refrigerant OR any other variant of CFC free refrigerant gas. | — | — | — | 12,49,113 | |
| — | 3.00 | — | — | ||
| Lifting Shifting, Erection, Installation, Testing and Commissioning of 28 HP Out Door Units suitable for VRF System. The system shall comprise of Outdoor Units with Air cooled condenser suitable for operation at ambient temperature of 56°C, delivering rated capacity at 43C without deration, high pressure Rotary / Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller and programming / diagnosis facility as per Railway Requirement. All Compressors shall be inverter type based on manufacturer's technology. The unit is to be given shipped with full operating charge of refrigerant and oil. Air cooled Condensor, refrigeration-piping controls, first charge of refrigerant etc. The Refrigerant used shall be any CFC free gas R410A refrigerant OR any other variant of CFC free refrigerant gas. | — | — | — | 97,266 | |
| — | 11.00 | — | — | ||
| Supply,of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU- compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz,AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation | — | — | — | 3,85,748 | |
| — | 11.00 | — | — | ||
| " Lifting, shifting, installation, testing & Commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz,AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation" | — | — | — | 42,856 | |
| — | 82.00 | — | — | ||
| "Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 2.2TR (594 cfm) to 2.8TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remoten control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete" | — | — | — | 23,11,252 | |
| — | 82.00 | — | — | ||
| "Indoor Unit : Lifting, shifting, installation, testing & Commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 2.2TR (594 cfm) to 2.8TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remoten control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete" | — | — | — | 2,56,742 | |
| — | 85.00 | — | — | ||
| Supply of Ref joints for Outdoor Unit of VRF. The size of Ref nuts joints should be as per manufacturer standards software suitable to gas piping should be procured from same OEM | — | — | — | 32,61,705 | |
| — | 85.00 | — | — | ||
| Installation, testing & commissioning of Ref joints for Outdoor Unit of VRF. The size of Ref nuts joints should be as per manufacturer standards software suitable to gas piping should be procured from same OEM | — | — | — | 32,045 | |
| — | 2100.00 | — | — | ||
| Supply of Refrigerant piping 'Hard Copper refrigerant piping of required sizes for pair of gas (suction) & liquid, with 19 mm Closed Cell Insulation for wrapping the copper pipe lines. The piping system must be supported at specific distance. Rates to include supporting system including installation of factory made joints as required. | — | — | — | 30,99,600 | |
| — | 2100.00 | — | — | ||
| Erection, testing and commissioning of Refrigerant piping 'Hard Copper refrigerant piping of required sizes for pair of gas (suction) & liquid, with 19 mm Closed Cell Insulation for wrapping the copper pipe lines. The piping system must be supported at specific distance. Rates to include supporting system including installation of factory made joints as required. | — | — | — | 3,44,400 | |
| — | 2500.00 | — | — | ||
| Supply of Communication cable between indoor to Outdoor unit 2 Core x 1 sq mm shielded CU cable | — | — | — | 1,62,500 | |
| — | 2500.00 | — | — | ||
| Erection, testing and commissioning of Communication cable between indoor to Outdoor unit 2 Core x 1 sqmm shielded CU cable | — | — | — | 22,500 | |
| — | 1000.00 | — | — | ||
| Supply of Communication cable between indoor to Outdoor unit 3 core x 1.5 sqmm Flexible CU Cable. | — | — | — | 45,000 | |
| — | 1000.00 | — | — | ||
| Erection, testing and commissioning of Communication cable between indoor to Outdoor unit 3 core x 1.5 sqmm Flexible CU Cable | — | — | — | 12,000 | |
| — | 1500.00 | — | — | ||
| Supply and Installation of indoor to outdoor 4Core x 4Sqmm CU cable XPLE insulated PVC Sheathed multi-standard armoured Copper conductor armoured cable confriming to ISS-1554 part-1 with suitable size glands and lugs as per site condition. | — | — | — | 1,77,000 | |
| — | 1500.00 | — | — | ||
| Erection, testing and commissioning of AHU panel to AHU Motor 4 Core x 4Sqmm XPLE insulated PVC Sheathed multi-standard armoured Copper conductor armoured cable confriming to ISS-1554 part-1 with suitable size glands and lugs as per site condition. | — | — | — | 40,500 | |
| — | 1000.00 | — | — | ||
| Supply of 4 core 6 sq.mm LT, XPLE insulated PVC Sheathed multi-standard armoured Copper conductor armoured cable confriming to ISS-1554 part-1 with suitable size glands and lugs as per site condition. | — | — | — | 1,13,000 | |
| — | 1000.00 | — | — | ||
| Laying, Transportation,testing & commissioning of 4 core 6 sq.mm LT, XPLE insulated PVC Sheathed multi-standard armoured Copper conductor armoured cable confriming to ISS-1554 part-1 to be laid underground/ wall with GI clamp of suitable size. The cable shall be terminated with suitable size glands and lugs as per site condition. | — | — | — | 20,000 | |
| — | 800.00 | — | — | ||
| Supply of 4 core 10 sq.mm LT, XPLE insulated PVC Sheathed multi-standard armoured Copper conductor armoured cable confriming to ISS-1554 part-1 with suitable size glands and lugs as per site condition. | — | — | — | 92,800 | |
| — | 800.00 | — | — | ||
| Laying, Transportation,testing & commissioning of 4 core 10 sq.mm LT, XPLE insulated PVC Sheathed multi-standard armoured Copper conductor armoured cable confriming to ISS-1554 part-1 to be laid underground/ wall with GI clamp of suitable size. The cable shall be terminated with suitable size glands and lugs as per site condition. | — | — | — | 4,800 | |
| — | 800.00 | — | — | ||
| Supply of 4 core 16 sq.mm , XPLE insulated PVC Sheathed armoured 1.1 KV grade Copper conductor with suitable size glands and lugs as per site condition. | — | — | — | 1,68,000 | |
| — | 800.00 | — | — | ||
| Laying, Transportation,testing & commissioning of 4 core 16 sq.mm , XPLE insulated PVC Sheathed armoured 1.1 KV grade Copper conductor with suitable size glands and lugs as per site condition. | — | — | — | 18,400 | |
| — | 800.00 | — | — | ||
| Supply of GI perforated cable tray of size 300mm x50mm x 1.6mm thick(cover type) | — | — | — | 2,63,200 | |
| — | 800.00 | — | — | ||
| Laying of GI perforated cable tray of size 300mm x50mm x 1.6mm thick(cover type) | — | — | — | 46,400 | |
| — | 800.00 | — | — | ||
| Supply of plain type cable tray of size 300mm x75mm with cover for refrigerent & drain pipe | — | — | — | 4,56,000 | |
| — | 800.00 | — | — | ||
| Laying of plain type cable tray of size 300mm x75mmwith cover for refrigerent & drain pipe | — | — | — | 51,200 | |
| — | 764.00 | — | — | ||
| Supply of plain type cable tray of size 150mm x75mm with cover for refrigerent & drain pipe | — | — | — | 4,04,920 | |
| — | 764.00 | — | — | ||
| Laying of plain type cable tray of size 150mm x75mm with cover for refrigerent & drain pipe | — | — | — | 45,076 | |
| — | 4000.00 | — | — | ||
| Supply of MS stand for condensing unit & MS tray for copper pipe & cables as per site requirement | — | — | — | 2,48,000 | |
| — | 4000.00 | — | — | ||
| Erection, testing and commissioning of MS stand for condensing unit & MS tray for copper pipe & cables as per site requirement | — | — | — | 40,000 | |
| — | 1500.00 | — | — | ||
| Supply of Drain piping in hard PVC with all fittings, supports and clamps. The piping shall be suitably insulated with 9mm thick closed cell foam Class O (Nitrile Rubber) stuck with approved adhesive compound.(25/50mm dia as per site requirement) (1 meter = 1 RMT) | — | — | — | 4,80,000 | |
| — | 1500.00 | — | — | ||
| Erection of Drain piping in hard PVC with all fittings, supports and clamps. The piping shall be suitably insulated with 9mm thick closed cell foam Class O (Nitrile Rubber) stuck with approved adhesive compound.(25/50mm dia as per site requirement) (1 meter = 1 RMT) | — | — | — | 54,000 | |
| — | 30.00 | — | — | ||
| "CIVIL FOUNDATION Desigin, preparation, Drawing and Digging of Soil / Concrete for MS structure legs at various points - Soil prepearation concrete base formation fixing MS structure, Providing base leveling and balancing the structure filling with suitable PCC at all points and finishing etc." | — | — | — | 7,59,780 | |
| — | 1997.00 | — | — | ||
| Supply of GI strip of 25 mm x 3 mm with nut bolts & washers. | — | — | — | 27,958 | |
| — | 1997.00 | — | — | ||
| laying of GI strip of 25 mm x 3 mm with nut bolts & washers. | — | — | — | 9,985 | |
| — | 16.00 | — | — | ||
| Supply of 40A MCB. with metal box complete as required for Outdoor unit operation | — | — | — | 14,928 | |
| — | 16.00 | — | — | ||
| Installation, testing and commissioning of 40A MCB. with metal box complete as required for Outdoor unit operation | — | — | — | 1,056 | |
| — | 16.00 | — | — | ||
| Supply of 63A MCB 2 Nos with metal box complete as required for AHU operation | — | — | — | 21,360 | |
| — | 16.00 | — | — | ||
| Erection, testing and commissioning of 63A MCB 2 Nos with metal box complete as required for AHU operation | — | — | — | 1,056 | |
| — | 50.00 | — | — | ||
| Core cutting at Slab area dia 50 mm | — | — | — | 47,700 | |
| — | 50.00 | — | — | ||
| Core cutting at Terrace area dia 100 mm | — | — | — | 47,700 | |
| — | 20.00 | — | — | ||
| Supply portion of minor Civil works such as making holes/Painting in walls etc. | — | — | — | 10,60,880 | |
| — | 20.00 | — | — | ||
| Erection portion of minor Civil works such as making holes/Paintig in walls etc. | — | — | — | 1,17,880 | |
| — | 14.00 | — | — | ||
| Transportation, Erection,testing &commissioning of 1.5/ 2 Ton,split type air conditioner fitted with rotary compressor R-22 refrigerant with nominal cooling capacity (k.cal/hr) 5800 - 6000 and minimum guaranteed cooling capacity (kcal/hr) 5500, minimum room discharge air flow (cub. mtr/hr) 800, EER (w/w) 2.9 - 3.1, 5 star rating , condenser and cooling coil should be of copper tube only. | — | — | — | 29,022 | |
| — | 200.00 | — | — | ||
| Supply, of 5/8" Copper pipes with nitrite rubber insulation | — | — | — | 50,400 | |
| — | 200.00 | — | — | ||
| erection, testing & commissioning of 5/8" Copper pipes with nitrite rubber insulation | — | — | — | 2,600 | |
| — | 200.00 | — | — | ||
| Supply of 3/8" Copper pipes with nitrite rubber insulation | — | — | — | 41,200 | |
| — | 200.00 | — | — | ||
| erection, testing & commissioning of 3/8" Copper pipes with nitrite rubber insulation | — | — | — | 2,200 | |
| — | 250.00 | — | — | ||
| Supply of water quality type heavy duty 3/4" PVC pipe for drainage of water from AC units. | — | — | — | 27,500 | |
| — | 252.00 | — | — | ||
| erection of water quality type heavy duty 3/4" PVC pipe for drainage of water from AC units. | — | — | — | 1,260 | |
| — | 14.00 | — | — | ||
| Design, fabrication, supply of M.S. angle stand of suitable size for outdoor unit of 1.5 / 2 TR split airconditioner | — | — | — | 16,856 | |
| — | 14.00 | — | — | ||
| painting, & Erection of M.S. angle stand of suitable size for outdoor unit of 1.5 / 2 TR split airconditioner | — | — | — | 6,580 | |
| — | 500.00 | — | — | ||
| Supply of XLPE armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | — | — | — | 81,000 | |
| — | 500.00 | — | — | ||
| Transportation, Laying, testing & commissioning XLPE armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/AL | — | — | — | 13,500 | |
| — | 500.00 | — | — | ||
| Supply of XLPE armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | — | — | — | 51,000 | |
| — | 500.00 | — | — | ||
| Transportation, Laying, testing & commissioning XLPE armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/AL | — | — | — | 13,500 | |
| — | 500.00 | — | — | ||
| Supply of XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | — | — | — | 52,500 | |
| — | 500.00 | — | — | ||
| Transportation, Laying, testing & commissioning XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/AL | — | — | — | 14,500 | |
| — | 500.00 | — | — | ||
| Supply of XLPE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | — | — | — | 56,000 | |
| — | 500.00 | — | — | ||
| Transportation, Laying, testing & commissioning XLPE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/AL | — | — | — | 14,500 | |
| — | 20.00 | — | — | ||
| Supply of maintenance freeearthing using copper coatedsteel rods compression coupleras per RDSO specification No.RDSO/PE/SPEC/PS/0109-2008(Rev-"0") or latest, withapproved enhancing compoundand exothermic welding. | — | — | — | 1,38,620 | |
| — | 20.00 | — | — | ||
| Erection, testing andcommissioning of maintenancefree earthing using coppercoated steel rods compressioncoupler as per RDSOspecification No.RDSO/PE/SPEC/PS/0109-2008(Rev-"0") or latest, withapproved enhancing compoundand exothermic welding. | — | — | — | 38,640 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
04PRICESANDPAYMENT.pdf
ATTACHMENT
01SPECIALINSTRUCTIONTOTENDERER.pdf
ATTACHMENT
03CONDITIONSOFCONTRACT.pdf
ATTACHMENT
07TECHNICALSPECIFICATION.pdf
ATTACHMENT
08GCC2022withadvancecorrectionslips.pdf
ATTACHMENT
05tenderscheduleKYN.pdf
ATTACHMENT
02INSTRUCTIONSTOTENDERERSkyn.pdf
ATTACHMENT
ExplanotrnoteKYN.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .