Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.4 L+₹1.2 L (19.2%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 |
Tender Value
₹6.6 L
EMD Value
₹13,175
Closing Date
28 Mar 2024, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Pdg. 25 KVA DG at Sub-Tehsil Building at Jakhal in Distt. Fatehabad (Pdg. 25 KVA DG Set)
2024_HRY_368886_1
2024EA3AD6DC EE7D 49BB AA29 555E82685F9C666BAR
Open Tender
Electrical Works
Works
120 days
Jakhal
2 documents required · 2 mandatory
₹1,000
₹13,175
Yes
31 Jul 2024
15 Mar 2024
29 Mar 2024
15 Mar 2024
28 Mar 2024
15 Mar 2024
Amount
[13.19]Providing and fixing galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm fixed on steel windows of standard rolled steel section, with 3 mm thick MS flat iron cover moulding of 12.5 mm width, fixed with machine screws welded complete in all respects. 0 0 0
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP
[23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts
[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.2.4.3]LT CABLE 4.3. Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core
[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia
[24.7.1]RCC FOUNDATIONS FOR DG SET 1. 30 to 40 KVA DG Set
Supply, Installation, Testing, and Commissioning of 25 KVA Liquid-cooled silent DG set confirming CPCB-II Norms comprising of liquid-cooled diesel/ engine developing 33.6 BHP @ 1500 rpm complete with Mechanical governor standard acessories coupled to `Leroy somer /Mecc Alte`25 KVA/20 KW alternator rated at 3 phase - 415 V, 50 Hz, 0.8 power factor @ 1500 rpm both mounted and alined on a common MS base frame complete with MS fuel tank integrated controlled panel, residential exhaust silencer, AVM pads fitted on the base frame, one no 12 V DC battery lead, first fill of lube oil and other features like Ease of information, QR enabled Gen Set, superior look: new attractive color scheme, multicolor gen set status indicator, silencer inside the canopy with compact design including AMF Panel suitable for 25 KVA DG set and complete in all respect up to satisfaction of engineer in charge of work. Make: Kirloskar, Greaves cotton, Cummins. (Rates are excluding GST)
Supply of LT Power Ard. Cables of Aluminium Conductor complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (Rates are excluding GST) Make:- Grandley/ KEI/ RR Kabel/ Polycab. 50 Sqmm 3.5 Core Ard. Cable
M/s JSB Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .