Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-AOC | ₹4.3 Cr | L1 | Accepted-AOC lowest |
| 2 | L2₹4.3 Cr+₹3.4 L (0.79%)Rejected-Finance | ₹4.3 Cr+₹3.4 L (0.79%) | L2 | Rejected-Finance not being lowest |
| 3 | L3₹4.7 Cr+₹35.3 L (8.21%)Rejected-Finance 123 B CENTRAL AVENUE SAINIK FARMS SOUTH DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | ₹4.7 Cr+₹35.3 L (8.21%) | L3 | Rejected-Finance not being lowest |
| 4 | L4₹4.8 Cr+₹50.4 L (11.7%)Rejected-Finance | ₹4.8 Cr+₹50.4 L (11.7%) | L4 | Rejected-Finance not being lowest |
Tender Value
₹4.4 Cr
EMD Value
₹5.2 L
Closing Date
25 Jan 2020, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CE DELHI ZONE DELHI CANT-10
CONSTRUCTION OF OFFICE ACCOMMODATION FOR PAO (OTHER RANKS), RRRC, DELHI CANTT
2019_MES_255821_1
CEDZ-04 OF 2019-20
Open Tender
Civil Works
Lump-sum
547 days
DELHI CANTT
MES contractor enlisted in MES under class A cat a i b i c ii having deposited Standing Security of Rs 7.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and categ
9 documents required · 9 mandatory
₹2,000
GE (P) EAST
₹5.2 L
Yes
10 Feb 2020
10 Dec 2019
27 Jan 2020
10 Dec 2019
25 Jan 2020
10 Jan 2020
Total amount of Sch 'A' Sec I (Building Work) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A' Sec II (Internal Water Supply) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec-II (Internal Water Supply) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 S&F Stainless steel fancy type health, faucet with 1 Mtr tube and hook of standard make complete all as specified and directed.
Subtotal
Total amount of Sch 'A' Sec III (Internal Electric Supply) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec-III (Internal Electric Supply) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 S&F sheet metal enclosure VTPN MCCB 250 Amp DB's 240 Volts, IP-43, suitable for mounting MCCB's, 4 pole, 4 way with insulated bus bar assly double door type complete all as directed by Engineer-in-charge.
Item No. 2 S&F MCCB 4 Pole 250 Amps,415 Volts, 36 KA rapturing capacity complete all as specified and as directed by Engineer-in-charge.
Item No. 3 M&L for lamp holder, angle type, PVC/polycarbonate type with back plate suitable for batten fitting With 10 watt LED lamp complete all as specified ad as directed.
Item No. 4 .S&F Decorative box type fitting with end caps pre wired for LED tube light fittings 16 watts with side holder, accessories and including connecting up with twin twisted flexible copper conductor cable of size 23/0.0076 from ceiling rose to light fittings complete including LED lamp complete all as specified and as directed.
Item No. 5 S&F Decorative sleek 2ft LED mirror light with diffuser of 10 watt with all required accessories complete all as specified and as directed.
Item No. 6 M & L Exhaust Fan 300 mm Sweep, 240 Volt, AC 50 HZ , metal body , heavy duty turbo forced including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed.
Item No. 7 Supply, installation testing and commissioning energy efficient electric geyser of capacity 25 Ltrs ISI marked 240 volt 50 Hz AC with inner stainless steel container, outer plastic body enclosure with glass wool insulation lining between inner SS container and outer enclosure including neccessary fixtures 4 nos 16mm dia 150mm long ms bolts nuts with washers grouted in wall with cement and sand mortar (1:3) with and including safety valve, non return valve 15 mm bore ISI marked with two numbers 15 mm dia 450 mm long PVC flexible conection with chromium plated brass unions one on each side for making flexible connection to geyser etc as directed by Eng-in charge.
Item No. 8 M&L IP 66 powder coated pressure die cast aluminium compact High Power LED bldg security light with heat resistant toughened glass of rating 25 W incl provn of 3 core PVC insulated, sheathed, stranded copper conductor cable/flexible chord of size 2.5 sqmm for electrical connection from ceiling rose to security/street light fitting complete all as specified & as directed.
Item No. 9 S&F Ceilling fan 1200 mm sweep, 230 volt, 50 HZ, complete all as specified and directed
Item No. 10 S & F RJ 112 Tel jack with shutter modular type complete all as directed by Engineer-in-charge
Item No.11 S&F single pole and neutral enclouser with a Two pin and earth plug and socket complete with one single pole MCB SP 20 Amps incluidng cutting chase and concelaing the same enclouser in wall and making well incluidng finishing of surfaces complete all as directed.
Item No. 12.S&F Recessed mounted LED Troffer 2 x 2 light fitting, neutral white enabled by advanced LED light . it blends into ceiling plane and maintains uniform luminance across aperature to enhance visual comfort and including connecting up electric connection from ceiling rose to light fittings complete all as specified and as directed Cat Part No. EZ RSXL 36W GZi, Make : Bajaj/ Cat Part No PBLM10364, Make- Panasonic/Cat Part No - HLFPR22-27-36-CW-DSS, Make - Helonix
Subtotal
Total amount of Sch 'A' Sec IV (Road, Path & Culvert) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A' Sec V (Sewage Disposal) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec-V (Sewage disposal) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 S&F of SFRC manhole cover with frame HD 100 MM thick complete all as specified and as directed by Engineer-in-Charge.
Subtotal
Total amount of Sch 'A' Sec VI (Area Drainage) (Part-II) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec-VI (Area Drainage) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 S&F of SFRC perforated meduim duty drain cover 100 mm thick complete all as specified and directed
Subtotal
Total amount of Sch 'A' Sec VII (External Water Supply) (Part-I) (Ref pre priced Schedule attached seperately)
Schedule 'A' Section-VII (External Water Supply) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 M & L for construction of brick masonary valve pit of size 90 x 90 x 90 cm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, incl. PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in beding and coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 15 cm below ground level providing valve pit 40 X 40 X 6 mm angle iron frame all round the fixed point by means of 04 Nos holdfast 150 mm long made out of flat iron 40 X 6 mm embedded in PCC block (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) of size 250 X 200 X 150 mm incl. provision of hinges welded with MS cover 3 mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement incl. 65 mm dia Godrej pad lock and applying two coats synthetic enamel paint over a coat of red oxide primer incl. necessary excavation and earth work in soft/loose soil complete all as specified and directed by Engr in charge.
Item No. 2 Cutting existing CI pipe line 150 mm dia, screwing and inserting ferrule for making new branch connection GI tube of 80 mm dia including necessary fittings complete all done in position without taking down complete all as specified and as directed by Engineer-in-Charge.
Subtotal
Total amount of Sch 'A' Sec VIII (External Electric Supply) (Part-I) (Ref pre priced Schedule attached seperately)
Schedule 'A' Section VIII (External Electric Supply) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 Supply, installing, testing and commissioning factory made and CDRI test certified LT main panel, Indoor type, floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system having bus bar chamber duly insulated Aluminium bus bars four strip of rating 400 Amps for phase & neutral, installed on epoxy/SMC type insulator. The panel shall be dust and vermin proof IP-54 class protection and made of 2 mm CRCA sheet and powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, internal wiring with PVC insulated, copper conductor, FRLS cables IS-694 marked of adequate size but not less than 1.5 Sqmm etc. complete all as specified and directed. The scope of work includes the following :-
(a) Incoming :- (i) MCCB 4 pole 250Amp 36 KA 415V (Main Incomming)
Item No. 2 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed Engineer In Charge
Item No. 3 Cutting bituminous road at a width not more than 30 cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with the existing surface complete all as specified and as direted by engr in charge
Item No. 4 Supply, installing, commissioning and testing complete of manufacturer of OEM (Original Eqpt Manufacture) manufactured and tested static Silent Diesel Engine driven generating set capable of delivering 160 KVA, 415 volts (AC 3 Phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternatore and mounted on Dunlop metallastik foundation pads on a common base frame and threafter intalled in the CPCB approved acoustic enclosure (the complete set conforming to and test certified as per CPCB norms and as specified) all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete and shall comprise of the following :-
(a) ENGINE (PRIME MOVER). Diesel Engine 1500 RPM of suitbale HP as recommended by manufacturer but not less than 206 BHP (at NTP) water cooled, Turbocharged aircooled, 1x 180 AH 12 Volts electric battery start, complete with fly wheel and all standard fittings/fixtures as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp & pressure gauge, water temp guage and frequency meter (digital type) including safety shutdown contents) and also including self starter, dynamo, fuel tank etc and conforming to I.S. 10002, ISO 3046, BS-5514. The engine shall give electrical out put of 160 KVA at 0.8 PF.
(b) ALTERNATOR. AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to BS 2613/IS 4722, 3 Phase, 415 volts, 50 Hz, 4 wire system output 160 KVA PF 0.8 1500 RPM insulation class `H' enclosure IP 23/TEFC complete with AVR with + 1% voltage regulation directly coupled to and match the above engine and capable for over load of 10% for one hr in 12 hr operation. ( c) CONTROL PANEL (AMF PANEL) The control panel to match with the requirment of DG set and shall be manufactred with 14/16 gauge CRCA sheet and is powder coated for a weather proof and long lasting finish . The control panel consist of following parts as per manufacred norms: (i) PCC- key switch/ Autostart Generator set controller. (ii) Multifunction meter displaying the parameter as voltage current, frequency water oil pressure KVA,KW (iii) Contractors with HRC fuse of suitable rating,current transformers, AMF logic Battery Charger< Aluminium Bus bar of suitable capacity indicating lamps. (iv) Standard foundation as per manufactrers specification anti vibration foundation pad of approved make & suitable capacity.
(d) Dunlop Metallastick anti-vibration pads for mounting engine - alternator assembly on the base frame/plate (e) BASE FRAME. Made out of structural steel as per manufactur's recommended design/specications.(f) ACOUSTIC ENCLOSURE. Provn of an integral type approved/certified acoustic enclosure as per CPCB norms for the DG sets restricted the noise level to 75 db at one meter along and temp rise within canopy shall not exceed 5° to 7° Celsius. It shall be made of 16 SWG CRCA MS sheet with powder coated finish on outside and provided with non igniting fire retardant foam as accustic material. There shall be four hinged doors out of which one shall be with a glass window. The base frame shall be ISM section. It shall also include the following :- (i) Silence absorption type, non-resistance, residential and exhaust pipe covered with asbestos rope lagging extending to about 2 mtrs outside the acoustic enclosures. (ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and flourescent lamp fittings.(iii) Fuel tank of 8 hrs capacity but not less than 400 ltrs made of 14 SWG CRCA MS sheet duly powder coated and provided with float, gauge and fuel float switch.
Subtotal
Total amount of Sch 'A' Sec IX (Rain Water Harvesting) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec IX (Rain Water Harvesting) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 .M & L for for drilling 250mm dia borehole by DTH cum Rotary at any depth below the ground level in any kind of rock/soil upto 40m depth including disposal of surplus soil to a distance not exc 50 mtr away from the site complete all as specified and directed.
Item No. 2 S & F for self perforated un plasticised PVC pipes 200mm dia of pressure rating 10 Kg/Sqcm fixed complete to wall or ceiling or in floors complete all as specified.
Subtotal
Total amount of Sch 'A' Sec X (Compound wall, Gate and Fencing) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec X (Compound wall, Gate and Fencing) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 .S&F stainless steel 3D letters of minimum height 300 mm , fixing to granite/cement plaster surfaces including all fitting/fixtures complete all as specified and directed by Engineer-in-Charge.
Subtotal
Total amount of Sch 'A' Sec XI (Demolition and dismantling) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A' Sec XII (Summer appliances) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec XII (Summer appliances) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No 1 Supply & installed desert cooler electric driven (single phase) having nominal air flow capacity 3200 Cu mtr per hr or nearest size available in market complete all as specified and as directed by Engineer-in-Charge.
Item No 2 S&F for Voltage stabilizer for automatic operation, single Phase Naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 2 KVA complete all as specified and as directed by Engineer-in-Charge
Subtotal
Total amount of Sch 'A' Sec XIII (Lift Work) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec XIII (Lift Work) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
(a) Cage with a four number LED 9 watt and cabin fan one number 300 mm sweep with grill,(b) Machine guide rails in `T' section with tongue & groove arrangement for smooth operation of the car and counter weight, (c) Landing - 4Nos (G+3), (d) Rated speed - 1.0 meter per sec, e) Rated load 08 Passenger 544 KGs , (f) Nos of opening & stops - 4/4 (four stops and four opening), (g) Electric motor AC 415 Volts, 3 Phase 50 Hz of suitable capacity cabling (FRLS) including all necessary PVC conduits, (h) Type of the operation - single automatic push button, (j) Type of the control - microprocessor variabale voltage and variable frequenc,(k) Type of signal system - Hall button with digital hall postion indicator digital car position indicator in car. All fixtures in stainless steel face plate (2mm thick), (l) Provn of LCD display system having GE (U) PM, Date & time, capacity of Passenger and Temp in 'C & F., m) Provn of travelling cables with copper conductor, junction boxes, wiring having copper conductor cables with provision of suitabel size GI/PVC through & other accessories complete, (n) Automatic rescue device battery operated to bring the car cage to the nearest floor level and auto opening for evacuation of passengers in the event of power failure & also to operate alarm & emergency light having power back up for a period of minimum 1 hr (60 min) with battery charger of adequate cap for battery charging within two hrs after each use,
(o) Earthing connections of the machine drive motor and control panel shall be done to the earth dolly, (p) RCC/PCC foundation all as specified and directed complete with suitable size MS ISMB, bolts, grouting plates etc, (q) Provn of hoist way and governors rope with governor, (r) Provn of Buffer springs as per manufacturer's design, (s) Car cabin will have VVVF drive powered doors, (t) Provn of dust proof inspection box on car top, (u) Provn of invertor of adequate capacity to operate the car cabin fan, car lights, emergency light, an alarm bell, intercom with battery back up for minimum one hr in the event of electric breakdown and with battery charging system complete all as specified and as directed by Engr-in-Charge, (v) Provn of any other components not considered in Sch `A' and required at the time of execution for smooth functioning of the lift as a whole.(w) Provn of suitable cap CVT for the new microprocessor controller to safe guard the electronic circuit and enable smooth functioning of the lift incase of voltage fluctuation in the system, (x) Provn of safety guarding eqpt such as 2 Nos pit switches, controller guarding, pit pulley guarding, pit ladder, facia plates to cover free space between car cabin & hoist way and rail switches et, (y) Provn of fireman switch complete at ground floor fitted in box having stainless steel face plate 2 mm thick and covered with glass cover
Safety measure : - (i) Over load relays (ii) Contactors and fuses (iii) Electrical terminals high quality (iv) Limit switch with accessories on each door/cage. (v) Gravity/counter weight limit switches for top most position (vi) Brake motor of suitable size with manned released arrangement. (vii) Single phase preventer for motor.Note :- (i) "Press & Speak" system to be connected with existing machine room independently. (ii) Existing intercom in the cabin/machine room shall be connected with existing communication network as desired. (iii) Do & Donts Steel plate have to be installed inside car cabin.
Item No 2 Fabrication,Supplying & installation, testing and commissioning of Electrical motor control panel for Lift of cubical construction double door panel wall mounted indoor type fabricated 2mm thick CRCA sheet compartmentalized with hinged lockable doors, dust and vermin proof, powder coated, single core PVC insulated FRLS copper conductor cables, having suitable mountings for switchgears and accessories and internal control & power wiring with suitable rating PVC insulated FRLS copper conductor, earth terminals numbering etc suitable for operation on 415V 3 phase 50 Hz AC supply with enclosure protection class IP 55 with 400 Amp rating Al bus bar etc complete as required
(a) Incoming :- MCCB 4 pole 63Amp 25 kA 415V(incomer for Lift ) 01 Nos, (b) outgoing :-MCCB 4 pole 25Amp 25 kA 415V(incomer for Lift ) make : Havells IHLASF0025 01 Nos, (ii) Digital type Volt meter 0-500 volt - 01 Set, (iii) Digital type Amp meter with CT's - 01 No, (iv) Indicating Lamps : 01 set, (v) Phase sequence corrector
Subtotal
Sch 'A' Sec XIV (AIRCONDITIONING) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No 1Supply & Installed wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality invertable type 3 star all copper tube and EER 3.2 of capacity 1.5 TR with all accessories and making good to disturbed surfaces complete all as directed.
Item No 2 S&F voltage stabilizer for automatic operation single phase naturaly air cooled indoor type wall mounted and designed for input variation between 130 V to 300 V, 12 A with output voltage stablizer at 230 V+/-9% complete all as specified and directed.
Item No 3 S&F single Pole & Neutral enclouser with two pole and earth metal plug and socket for incorporating 6-32A SPN MCB.
Item No 4 S&F MCB 6-32 A SPN C series 10ka complete all as specified and as directed.
Subtotal
Total amount of Sch 'A' Sec XV(Site clearnce work) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A' Sec XVI (FIRE FIGHTING) (Part-I) (Ref pre priced Schedule attached seperately)
Sch 'A' Sec XVI(FIRE FIGHTING) (Part-II) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No 1 Fabrication,Supplying & installation, testing and commissioning of control panel for fire fighting pump,jockey pump suitable for 415 Volts,3 phase 4 wire 50 Hz power distribution system the panel should be free standing free mounting compartmentlize design of 2mm thick CRCA sheet steel compartmentalized with hinged lockable doors, dust and vermin proof, powder coated,IP 52 painting earthing numbring danger plate as per specfication and drawing flush front with 200 Amps copper busbars seprate earth bushbar to be provided throught the length of the panel . the incoming and outgoing feeder breakers fuses indicating lamps etc shall be accomodated in a modular multi tier arrangement. the paint shall be done as per relevant IS codes/as specified in the specification adequet size cable shall be provided all around the panel shall be connected throug copper bus bar. bus bar shall be provided with heat shrinkable sleeves and shall be colour coded . the panel shall be suitable for cable entry from top the panel shall be facricated after the approval of fabrication drawing in wiring from Engr in charge. The panel shall consist of the following.
Item No 2 S & F Dry chemical type Fire Extinguisher ISI marked in 6.0 Kg Cap confirming to IS: 15683-2006 duly filled with ISI marked powder confirming to IS : 15683-2006 duly filled with ISI marked powder confirming to IS: 14609 with squeeze grip release valve, discharge pipe, pressure gauge locking arrangement,operation manual and wall bracket.
Item No 3 S & F CO2 type Fire Extinguisher ISI marked in 4.5 Kg Cap confirming to IS: 15683-2006 complete with wheel type control valve, locking arrangement,operation manual and wall bracket.
Item No 4 S & F Clean Agent Fire Extinguisher ISI marked in 4 Kg Cap confirming to IS: 15683 complete with control valve, locking arrangement,operation manual complete all as specified and directed.
Item No 5 S & F Mechanical Foam Fire Extinguisher ISI marked in 9 Ltr Cap confirming to IS: 15683 complete with control valve, locking arrangement,operation manual complete all as specified and directed.
Item No 6 S & F Dry Powder (ABC) Fire Extinguisher ISI marked in 9 Kg Cap confirming to IS: 15683 complete with control valve, locking arrangement,operation manual and wall bracket complete all as specified and directed.
Item No 7 S & F Wheeled Dry Powder Extinguisher ISI marked in 25 Kg Cap confirming to IS: 15683 complete with wheel type control valve, locking arrangement,operation manual and wall bracket.
Item No 8 S & F Steel Fire Bucket (Dry Sand) ISI marked with red colour quoted with FIRE mark in black colour confirming to IS: 2546 complete all as specified and directed.
Item No 9 S & F Fire Exit Sign ISI marked with green colour quoted with EXIT mark in white colour complete all as specified.
Item No 10 . Supply installation, Testing and Commissioning of networkable 4 Loop Micro processor based fire alarm panel, 2 wire fault tolerant loop shall have the capability of connecting 126 device. The fire alarm control panel shall have built in degrade mode function. The panel should have inbuilt TCP/IP communication. The panel shall be able to give location of all fire and more Fire / fault and Isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing upto 2000 events. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel should have protection category of IP30. Also the panel should have the option to operate in manned and unmanned mode. The Panel should have the option of 24/48/96 Zones with individual LED indicators or with in the Loop mimic driver for 96 LED indicators. The panel shall have built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volts SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and as per specifications and duly Approved by EN54/LPCB/VDS/FM. Make – Siemens/Tyco/Notifier
Item No 11Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, active Repeater Panel / Remote Terminal with mounting bracket and required installation accessories. The remote terminal shall facilitate motoring & control of fire events from pre-decided strategic location away from the main FACP. The remote terminal shall facilitate monitoring and control of fire events for each and every device connected to the FACP. It shall have 6 lines x 40 characters display. Make – Siemens / Tyco/Notifier
Subtotal
Total amount of Sch 'A' Sec XVII (EXCAVATION AND EARTH WORK) (Ref pre priced Schedule attached seperately)
Subtotal
India Guniting Corporation
Third Wave Services Pvt Ltd
Ashish Sehgal and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .