Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.4 L+₹1.5 L (4.11%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹38.5 L+₹1.6 L (4.30%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC L3 | |
| 4 | L4₹38.8 L+₹1.9 L (5.21%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹39.7 L+₹2.8 L (7.55%)Rejected-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-AOC L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Nov 2024, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore-63
REPAIR/REPLACEMENT IN WATER SUPPLY DISTRIBUTION SYSTEM AND CONNECTED ITEMS AT AFS YELAHANKA
2024_MES_680937_1
8314/E8
Open Tender
Civil Works
Item Rate
90 days
Yelahanka
Refer Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹90,000
Yes
7 Dec 2024
23 Oct 2024
15 Nov 2024
23 Oct 2024
13 Nov 2024
6 Nov 2024
Amount
Excavation in trenches inot exceeding 1.5 mtr width and not exc 1.5 mtr deep for laying of pipe etc and getting out in hard/dense soil all as specified and directed.
Returning, filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick hard/dense soil all as specified and directed
Removing surplus soil to a distance 50 mtr and deposit where directed at alevel not exceeding 1.5 mtr above the starting point all as directed
Taking up/down steel tubing of the following sizes and disconnections of fitting, joints from tubing where required complete all as specified and directed
Supply and laying of GI water tubing of the following sizes in trenches medium grade ISI marked including all types of fittings such as bends,elbows,tees,short pieces,connectors,backnuts,diminishing pieces,caps,plugs and unions etc and accessories complete all as specified and directed
Supply and fixing of GI tubing of following sizes in walls/ceilings or laid in floors of medium grade ISI marked including all types of fittings such as bends,elbows,tees,short pieces,connectors,backnuts,diminishing pieces,caps,plugs and unions etc and accessories complete all as specified and directed
Supply and fixing in replacement Gun metal gate valve/globe valve of following sizes ISI marked with Iron wheel head screwed both end for GI tubing complete all as specified and directed
S &F in replacement of GI union of following size ISI marked complete all as specified and directed
Supply and fixing in replacement GI nipple of following sizes ISI marked with Iron wheel head screwed both end for GI tubing complete all as specified and directed
(a) 20 mm dia , 6inch long
(b) 20 mm dia ,9inch long
(c) 20 mm dia ,1ft long
(d) 20 mm dia ,2ft long
(e) 25 mm dia , 6inch long
(f) 25 mm dia ,9inch long
(g) 25 mm dia ,1ft long
(h) 25 mm dia ,2ft long
Supply and fixing in replacement GI socket ISI Marked for GI tubing of following sizes pipe complete all as specified and directed
Supply and fixing in replacement GI elbow ISI Marked for GI tubing of following sizes pipe complete all as specified and directed
Supply and fixing in replacement GI tee ISI Marked for GI tubing of following sizes pipe complete all as specified and directed
Supply & Fix in replacement GI reducer socket of the following size dia for GI Pipe medium grade ISI marked all as specified and directed.
(a) 50 mm / 15 mm dia
(b) 25 mm / 20 mm dia
(c) 40 mm / 20 mm dia
(d) 50 mm / 20 mm dia
(e) 40 mm / 25 mm dia
(f) 50 mm / 25 mm dia
Supply & Fix in replacement GI plug of following size dia suitable for GI Pipe medium grade ISI marked all as specified and directed.
(a) 20 mm dia
(b) 25 mm dia
(c) 40 mm dia
(d) 50 mm dia
Taking up cast iron water mains including all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead of pipe of following size dia all as specified and as directed.
Supplying, laying, jointing and testing in replacement of Ductile Iron pipe class K-9 socket and spigot type of size 100 mm dia all as specified and as directed
Supplying, laying, jointing and testing in replacement of Ductile Iron pipe class K-9 socket and spigot type of size 150 mm dia all as specified and as directed
Material and labour for Ductile Iron specials for bends (any type, radius and angle) tapers any type,(straight ,bend, increasing, decreasing, or double socket etc) Tee pieces single branch."Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs up to 150mm bore DI pipes all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of following size dia including replacing/tightening the existing bolts and nuts etc. complete all as specified and directed .
Dismantling and taking down unserviceable sluice valve of following size dia from valve chamber/pipe line all as specified and as directed
Material and labour for sluice valve ISI marked of following size dia both end flanged PN 1.0 with fixing arrangements such as bolt / nuts, rubber packing’s etc all as specified and as directed.
Material and labour for removing unserviceable lead joints from CI pipe line and making proper run lead joints of following size dia pipe complete including necessary excavation, refilling and removing the surplus soil all as specified and as directed.
Dismantling and unscrewing the bolt/nuts, taking out the suction pipe upto 30 mtr along with unserviceable foot valve of following size dia all as specified and as directed.
Material and labour for CI foot valve ISI marked flanged type of follwing size dia , PN 0.2 complete with bolts/nuts, washers, rubber packing etc all as specified and as directed.
Taking down unserviceable Non return valve of follwing size dia from pipe line all as directed
(a)100mm dia
(b) 80mm dia
Material and labour for CI Swing Non return valve/check valve PN 1.6 of following size dia both end flanged with fixing arrangements such as bolt / nuts, rubber packing’s etc all as specified and directed.
(a)100mm dia
(b) 80mm dia
Dismantling the existing unserveciable valve chamber in complete and Construction of valve chamber of Internal size 900mm x 900mm x 900mm deep with 200mm thick PCC block masonary walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (using 40 mm graded coarse stone aggregate) with 100 mm off sets, 15mm thick and internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brass and keys (Make : Godrej / Shell/ Harrison), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
All as per Item No.27 here in before but for internal size 1200mm X 1200mm X 1200mm size
Material and Labour for repacking stuffing box of sluice valve spindle including taking apart and reassembling for the following sizes complete all as specified and directed .
(a) 80mm dia
(b) 100mm dia
(c) 150mm dia
M & L for Taking out sluice valves refacing, regrinding and refixing for the following sizes
(a) 80mm dia
(b) 100mm dia
(c) 150mm dia
S&F in repair stainless steel pressure guage analogue type 0 to 10kg/cm2 ,accuracy of 1.6% FS , Connection 1/2" BSP , 100mm dial size and necessary fittings for connection etc including taking down existing one all as specified and directed by EIC
M&L for cutting of road/hard standing not exc 30cm in width and not exc 60cm in depth for removal/laying of water tubing including returning filling and making good the disturbed surfaces using PCC 1:2:4 type B1 using 20mm graded stone aggregate on top 120 mm layer and fair fininshing the surface without using any extra cement complete all as specified and directed.
S&F in repair manhole covers / valve pit covers fabricated out of MS sheet, MS flat and angle iron of required sizes or shapes required at site and painting with two coat of black synthetic enamel paint over a coat of red oxide primer including taking out / dismantling rusted or unserviceable covers of UG sump/OHT/valve pits, etc. and disposing off complete all as specified and as directed
Taking down unserviceable float and board water level indicator and M&L in repair for float and board water level indicator aluminium powder coatedd of float diameter 300mm along with pulley,flange, telescopic pipe,pointer etc fitted on a MS channel with suitable distance and fixing in position including painting of indicator scale with required marking upto 4mtr complete all as specified and directed by Engineer-in-charge.
Labour only to locate the any kind of fault/leakage in water pipe line GI upto 80 mm dia and any type by digging only along the length of water pipe line and upto the depth of water pipe line bottom to locate the exact pin point location of fault/leakage including rectification of fault with the help of plumber, returning filling of same by tightening the union, replacing of elbows, sockets, tees, nipple, check nuts etc complete all as directed. Note: i) The excavation,removal,returning filling upto 2mtr is included in the item and beyond the length of 2 mtr along the pipe line shall be measured under the respective items of excvation of this shedule. ii) The items required to replace shall be measured and paid seperately under the relevent items of this schedule. iii) The quoted rate is deemed to be included the rate of Plumber & labour for digging.
Labour only to locate the any kind of fault/leakage in water pipe line CI/DI 80 mm to 150 mm dia and any type by digging only along the lenth of water pipe line and upto the depth of water pipe line bottom to locate the exact pin point location of fault/leakage including rectification of fault/leakage i) The quoted rate is deemed to be included the rate of Plumber & labour for digging. ii) The The excavation,removal,returning filling upto 2mtr is included in the item and beyond the length of 2 mtr along the pipe line shall be measured under the respective items of excvation of this shedule.
M&L for cleaning of valve chamber after removing debris,leaves,stones or dirt,trim grass,roots, etc accumulated around the valve chamber of size 900mmx900mmx900mm including opening of valve chamber covers and closing as original with proper locking system and throwing garbage to the area all as specified and directed.
All as per item No. 37 but size 1200mm x 1200mm x 1200mm
Deployment of T&P and labour for cutting and removing the grasses / vegetation growth in the surrounding area of water supply installations and dispersals by using tractor equipped with jungle jim and disposing off all the rubbish to distance exc 250 meter but not exc 500 meter complete all as directed
Supply only High strength Calcium based granular chlorination chemical of following Specifications:- Make: Declicab/Aquafit /PURI chlor (a) Chemical analysis and Physical observations:- Description:- White granules Granular size:- (Mess passing through-100 BSS): 1:1(+ 0.1%) Water/ Moisture: 5.00(+0.2)% Other insoluble Calcium salt:- 1.1(+0.1)% Mercury and other Heavy Metal contaminants:BDL.The chlorination chemical must contain appropriate quantities of dispersants/corrosion inhibitors to prevent encrustation/scaling in distribution systems (b) Strength of Items of quantity of chlorination chemical required to obtain free chlorine of 1 PPM per one lakh liters of water: Requirement must be 125-200 grams per one lakh liter of water to achieve 1 PPM Av.Cl at injection point( Site and raw water quantity variation may apply additionally (c) Stability:- Projected shelf life of chlorination chemical must be one year with minimal loss of chlorine (d) Handling of chlorination chemical for regular chlorination (e) Operational considerations: Must be safe to use in terms of level of insoluble components. There must be no risks relating to encrustations in equipment and pipe lines, no sludge generation, no hard water scaling in supply water. (f) Operator health considerations: Chlorination chemical must contains acceptable levels of granular size to avoid risks to operators from health safety point of view. (g) Safety & health hazard aspects on usages of chlorination chemical for regular drinking water chlorination Mercury and other Heavy Metal contaminants in chlorination chemical must be Below Dectectable Limit(BDL),based on which the product must be considered safe to use from human health safety point of view and freedom from toxicity when used in drinking water chlorination in recommended dosage.
S&F in replacement synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m all as specified and directed.
M&L for jointing of DI Pipes with rubber tyton joints all as specified of folllowing sizes all as specified and as directed
Dismantling and taking out the Unserviceable 50 mm dia column pipe from the borewell/wells all as directed.
Supply and Fixing of GI column pipe heavy grade 50mm dia with ISI mark with GI heavy socket at one end all as specified and as directed
Supply and fix in repair bus bar box of size 450x300x500mm fabricated by 3mm thick MS sheet outdoor type , dust/vermin proof, mounted/ fixed on angle iron frame of MS equal angale size 40x40x6mm of height 0.90 mtr, erected in ground with PCC foundation 1:4:8 with 40mm stone aggregateand including aluminium bus bar flat of size 50x6 mm fixed as bus bar over the insultors, sleeved for three phase and neutral, provision of one MCCB 63 Amps 4 Pole, 415 AMps, 50 Hz of breaking capacity 16 KA and spray painting the box with two coats of enamel paint over a coat of metal primer incuding necessary excavation, PCC for fixing the box compelete all as specified and directed
Supply , laying and testing cable XLPE insulated, screened, PVC bedded galvanised stell strip or wire armoured electric power cables ( heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core.
eurekaenterprises (BID ID -3163898)
devan enterprises (BID ID -3164594)
chowdeshwariconstructionco (BID ID -3163933)
ANAND REFRIGERATION (BID ID -3162947)
Standard enterprises (BID ID -3163257)
JM Engineering (BID ID -3164380)
PLATINUM CONSTRUCTIONS (BID ID -3164327)
EURO ENTERPRISES (BID ID -3164233)
SAPTHAGIRI CONSTRUCTIONS (BID ID -3163855)
KUZHIKKAL ENTERPRISES (BID ID -3163804)
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .