| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.9 L+₹58,654 (2.07%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.4 L+₹1.1 L (3.79%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹29.5 L+₹1.1 L (3.99%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹31.0 L+₹2.6 L (9.25%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Jul 2024, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
CLEANING REPAIR AND MAINTENANCE OF SEWAGE LINE SEPTIC TANKS MANHOLES SOAK WELLS COVER SLABS ETC IN BAIRAGARH AREA UNDER GE BHOPAL
2024_MES_662374_1
8302/E8
Open Tender
Civil Works
Item Rate
335 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹80,000
Yes
11 Oct 2024
27 Jun 2024
25 Jul 2024
27 Jun 2024
23 Jul 2024
11 Jul 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense of soil complete all as specified and directed.
All as per item No. 1.00 here-in-before but for exc 1.5m in depth
Demolition and breaking up drain pipes of 150mm (SGSW, AC, RCC or PVC), set in cement mortar and disposal of unservicable materials and rubbish to a distance not exceeding 100m complete all as specified and directed.
All as per item No. 3.00 here-in-before but for 200mm size
All as per item No. 3.00 here-in-before but for 300mm size
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete including sub base of floors complete all as specified and directed.
S&F of 200mm (DWCPE Pipe) class SN-8 structural wall polyethylene (Pipe with online coupler and elastomeric rubber ring) with hollow annular smooth outer surface and a smooth inner surface (double wall plain) for non-pressure underground drainage and sewage application Type B Nomial size (Dn/ID) made of polyethylene (PE) material confirming to ISI 6098 (Part II : 2013 and to be transported handled installed and joied as per Annex A Of ISI 6098 (part II :2013 complete all as specified and directed.
All as per item No. 8.00 here-in-before but for 300 mm size
M&L for 200mm reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
All as per item No. 10.00 here-in-before but for 300mm size
M&L for 200mm concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tasted; in cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) complete all as specified and directed.
All as per item No. 12.00 here-in-before but for 300mm size
Removal of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.
Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed.
S&F in repairs 75mm PVC(SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or fixed to walls including clamps complete all as specified and directed.
All as per item No. 16.00 here-in-before but for 110 mm size
S&F in repairs 75mm PVC(SWR) bend complete all as specified and directed.
All as per item No. 18.00 here-in-before but for 110 mm
S&F in repairs 75mm PVC(SWR) junction single (single 'T') equal or unequal complete all as specified and directed.
All as per item No. 20.00 here-in-before but for 110 mm size
S&F in repairs 75mm PVC(SWR), vent cowl complete all as specified and directed.
All as per item No. 22.00 here-in-before but for 110mm size
S&F in repairs 75mm dia PVC (SWR) floor/Nahani trap with grating including jointing to waste pipe fixed with solvent cement complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the permises complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8, type D-2 as in floor to receive floor finishes, complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4, type B-1 (20 mm graded stone aggregate) as in floor to receive floor finishes complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7mm to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm, but not exceeding 0.18 Sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 450mm X 300mm X 7 to 8 mm thick in vertical surface, set and jointed over and including 10mm thick rendering even and rough in CM 1:4 for backing of tiles, jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
S&F in repairs vitreous china squatting pan "Orissa Pattern" size 580mm x 440mm white with integral foot rests, including providing of cement concrete bedding and 'P' or 'S' trap as required complete all as specified and directed.
S&F in repairs PVC low level flushing cistern 10 ltrs capacity with all internal fittings including flush pipe and fixing to supply pipe including PVC connection 600 mm long 15 mm bore with brass heads & washers with connections fixed complete all as specified and directed.
S&F in repairs 32mm PVC waste pipe 80cm long complete all as specified and directed.
Demolition of brick work, built in cement mortar including all quoins, arches, pillars etc compete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cm 1:6 complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping, channel, benching of manhole laid to shape and slope and finished even and smooth using extra cement including weathering, throating and necessary form work complete all as specified and directed.
M&L for 15 mm thick plaster in CM 1:4 on brick walls or concrete surfaces and in any position including finishing the surfaces fair and even without using extra cement complete all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed.
S&F in repairs factory made precast cement concrete cover for manhole, M-20 with 8 mm dia, mild steel bar @ 100 mm c/c both way and mild steel hook both side complete of size 600mm X 600mm X 70mm complete all as specified and directed. Note:- Rate inclusive of reinforcement and hook.
All as per item No. 38.00 here-in-before but of size 600mm x 450mm x 70 mm
All as per item No. 38.00 here-in-before but of size 900mm x 450mm x 70 mm
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizontal/Sloping) receive for fair finished surfaces complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) using 20mm graded aggregate type, B1 1:2:4 on as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Labour only for cleaning and de-sludging of septic tanks of 300 user septic tank of any depth including taking out sludge in any form alongwith all other forign materials by mechanical pumping equipment with taking all precautionary measures including removal of sludge and other foreign materials out side defence land by any means complete (working in foul condition) all as specified and directed
All as per item No. 43.00 here-in-before but for 250 user septic tank
All as per item No. 43.00 here-in-before but for 200 user septic tank
All as per item No. 43.00 here-in-before but for 150 user septic tank
All as per item No. 43.00 here-in-before but for 100 user septic tank
All as per item No. 43.00 here-in-before but for 50 user septic tank
All as per item No. 43.00 here-in-before but for 25 user septic tank
All as per item No. 43.00 here-in-before but for 10 user septic tank
Labour only for cleaning of all blockage of any type of sewage line i.e. branch sewer line, main sewer line etc, manholes of any size and depth, in any situation by way of cleaning/de-sludging by manually or mechanically or by way of any other suitable means including foreign materials as well as rodding (full through) of sewer lines and between the blocked manholes where required and ordered by Engineer-in-charge and keeping the sewage line all time functional, cleaning traps, water closet, soil waste/vent pipe, gully traps etc complete upto final drop out let into septic tanks or central sewage treatment plant and/or soakage well (working in foul condition) with taking precautionary measures with necessary equipment as required and applicable all as specified and directed. The sludge removed from the manholes and sewage line shall be removed to out side Defence land complete all as directed by Engineer-in-charge in entire Bairagarh Military Station i.e., various units area and single living Accn of 3 EME Centre (all Bns & Coys), 5221 ASC Bn, 1010 Tpt Coy, Military Dental Centre Bhopal, 194 FWC, 4021 Fd Hosp, 21 Corps HRDC, 68 Engr Regt, 755(I) Tpt Coy, GE Bhopal, AGE E/M, Sup Depot, ECHS, MH Bhopal, 21 CGSR, JCOs/OR Md Accn at Panama and CTO colony, Offrs Md Accn at Vijay Enclave, Old Sanchi, Sanchi Enclaves & CTO, Civ Md Accn at CTO Note:- (1) Contractor will deploy 04 (Six ) Nos safaiwala and 01 (one) supervisor per working day in the MES office/complaint cell and will report to the concerned JE/Engineer-in-Charge daily at 9.00 AM to 5.00 PM. (2) If any of the Safaiwala/Supervisor fails to report daily to the concerned authority, a sum of Rs. 700/- will be deducted per person/day from the payment of the contractor. (3) The Safaiwala will always be in posession of the cleaning tools like 6mm MS round bar/rod, plain flexible bamboo pieces and cleaning pump with wooden/PVC handle. The rate quoted is deemed to be inclusive of the cost of T&P for maintenance/cleaning work.
Deduct Schedule of credit (calculation will be done off line) Rs. 42010.00
RAJPATI CONSTRUCTION (BID ID -3061233)
AYANSH ASSOCIATES (BID ID -3058162)
ROYAL CONSTRUCTION (BID ID -3062000)
SHIV SHANKAR MISHRA (BID ID -3064094)
Maa Bhawani Construction (BID ID -3063580)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .