Col N K Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
PROVISION OF 40 KVA DG SET FOR VAIRENGTE UNDER GE SILCHAR
2023_MES_589480_1
8712/E8
Open Tender
Civil Works
Item Rate
120 days
Silchar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Silchar
₹18,000
Yes
22 Jun 2023
13 Apr 2023
29 May 2023
13 Apr 2023
22 May 2023
3 May 2023
Amount
Supply, Install, testing and commission sound proof acoustic enclosure diesel engine driven generating set, fully wired 415 volts, +/- 1.5%, 3 Phase 4 wire 50 HZ, +/- 0.5% 0.80 PF of capacity 40 KVA 32 KW having continous rating at 1500 RPM , brushless self excited and minimum of 56 BHP capacity engine turbo charged water cooled complete under NTP condition with provision for 10% over load for 1hr on 12hr running and common base plate frame engine standard instrumental panel, self exciting and self regulating control panel with accessories, self starter 12 volts with battery 90 AH, 12 volts -01 Nos system with battery charging unit SCR type and battery cable leads, exhaust pipe with cladding by asbestos rope, sound proof canopy as per CPCB norms II etc. Diesel engine set as per ISO 3046/ BS 5514 and alternator as per IS -13364 with inbuilt centrifugal mechanical governer based control panel with floor mounted fuel tank not less than 12 hours running capacity including necessary anti vibration pads including standard control panel as recommended by the manufacturer.
(A) The diesel engine comprising of following:- (i) Fly wheel to suit coupling (ii) Flexible coupling with guard bolts and nuts, etc. for exhaust system (iii) Dry type air cleaner filters (iv) Radiator with guard and radiator fan (v) Fuel pump complete with fuel injection systems (vi) Centrifugal mechanical governor (vii) Fuel filter (viii) Lub oil filter (ix) Self starter 12 Volts DC (x) Exhaust silencer industrial type with pipe 3 m long (xi) Turbo charger (xii) Lub oil pump (xiii) Lub oil cooler assembly (xiv) Alternator 12 V for charging of battery (xv) One hand rotary type fuel pump connected with heavy duty pipe upto the tank
(C) ALTERNATOR : It shall be self excited self generated balanced 415 volts, 3phase, 50 Cycles per second, 40 KVA at 0.8 PF or nearest in higher capacity, 1500 RPM, star connected, 4 wire, drip proof enclosure, air cool with radial fan mounted on rotor, screen protected, self ventilated enclouser as per IS 4722/IS 2613 & IEC 34.10 with drip proof enclouser with damper winding on pole faces, static automatic voltage regulator to provide voltage regulation +/-1% and harmonic factor better than 2% from no load to full load from 0.8 to unity power factor, efficiency 92% at 100% load/0.8PF, voltage drop at full load < 20% and insulation of H class and above as per standard practice of OEM.
(D) Starting batteries 12 V, 90 AH maintenance free with suitable size of cable including fitting and terminals on angle iron frame (self starter system with 12 volts DC) - 01 No Make Exide/ Amaron /Nicco / Amco (E) Fuel Tank : Made of 1.6 mm thick CRCA sheet and having continous running of 12 Hours at full load with level indicator to indicate the oil level of diesel tank, fuel strainer air vent inlet and out let connections with MS pipe of suitable size complete all as specified and as directed.
(F) Sheet steel components pre-treated with Zinc phosphate prior to polyster powder coating. (G) Zinc plated or stainless steel fasteners (H) EPDM quality gasket (xvii) Provison of light inside the canopy (xviii) Radiator filling access facility from out side (J) Engine and alternator shall be mounted through AVM pads on common channel iron base frame (K) Noise level, less than 75 db (A) at 1 mtr distsnce controlled by providing specially designed alternator to controlled the sound at air entry and exit of the enclosure (The make of Acoustic enclosure shall be OEM of DG Set) (Foundation : Cost of PCC foundation as per manufacturer's instructions shall be deemed to be included in the quoted rate)
(L) Gen set controller cum AMF panel made out of CRCA sheet as per OEM recommendation factory fitted with MCCB for short circuits protection & necessary power contactor for AMF operations, microprocessor based controller with display arrangement and inbuilt engine protection mechanism & complete with necessary control wiring, bus bars, battery charging system etc.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 35 Sqmm 3.5 Core laid in trenches or fixed to wall / pole /ceiling as per IS 7098 (part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed. Note : Earth work, brick protection and send cushioning and GI Pipe will be measured and paid separately under respective items.
Supply and fix ON Load change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all specified and directed by Engr-in-Charge.
Excavating in trenches, n exec 1.5 m wide and n exec 1.5 m depth , for foundation ,etc or for shafts ,wells, cesspits, manholes, pier holes ,etc n exec 10 sq m on plain and n exec 1.5 m in depth and getting out soft or loose soil.all as specified and as directed by engr-in-charge.
Returning, filling in, including spreading,leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-Charge
Removing excavated material not exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Supply & laying GI Tubes, 'light grade', galvanised, with all fitting; laid in trenches of 50 mm dia complete all as specified and directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .