Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹19.1 L+₹61,690 (3.33%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L2 | Rejected-Finance 2nd lowest bid |
Tender Value
Refer Docs
EMD Value
₹41,800
Closing Date
21 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal
REPAIR /MAINTENANCE OF LT OVERHEAD LINES, UG CABLES, AND ALLIED WORKS AT DRONACHAL BASE BHOPAL
2021_MES_444998_1
8618/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Dronachal
Price bid
5 documents required · 5 mandatory
₹500
Yes
GE Dronachal
₹41,800
Yes
26 Aug 2021
22 May 2021
25 Jun 2021
22 May 2021
21 Jun 2021
5 Jun 2021
60 days
Amount
Excavation in trenches in soft/loose of soil not exceeding 1.5m deep and not exceeding 1.5 m wide and getting out complete all as specified and directed.
Excavation in trenches and exceeding 1.5m in depth but not exceeding 3.00 m depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified.
As as per item No 2.00 above but in disintigrated rocks
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested , all as specified and directed at site.
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work , all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , with two coat of lime wash on coping and all as specified and directed.
Dismantling existing stay assembly of any type and size fixed with existing poles,disconnecting all components and supply and fixing new stay assembly, complete comprising of MS galvanized stay plate 23cm x23cmx6mm , MS galvanised stay rod 20 mm dia with nut 215 cm long , MS galvanised stay bow 40cm long with 2 Nos galvanized thimbles with and including all fittings all as specified in SSR-2009 Part I. Note:- 1. Excavation , PCC for foundation, etc shall be measured and paid seperately. 2. Stay wire and loop type insulator to be measured and paid as supply only under respective item of this BOQ .
Supply only MS galvanised stay wire stranded size 7/4.00mm complete and taking out old wear and tear stay wire.
Supply only Insulator loop type porcelain vitreous, white brown or green with overall dimensions of 90x140mm clearenace of hole 25.5mm complete all as specified.
Dismantling/Taking down old guard wire and stay wire of galvanised iron wire from LT over head line PCC/Steel pole and removal from site being contractor property as included in credit schedule.
M&L galvanised steel wire 4mm dia for contineous earth wire and for guarding and cradles including binding as required with binding wire complete all as specified and directed
M&L for replacement existing worn out /over heated/ multi-jointed ACSR jumpers of LT over head lines with and incl XLPE/PVC insulated 1100 volts multi stranded aluminium conductor single core cable of size upto 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral incl winding with ACSR conductors with suitable size aluminium binding wire complete all as specified and directed . Note:Length of one jumper not exceeding more than 2.0 mtrs.
Dismantling/taking down old LT, over head line of ACSR from PCC/Steel pole and removal from site being contractor property as included in credit schedule
M&L for LT overhead lines on PCC/steel poles with aluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete all as specified. Size/make for new conductors: Mink/Beaver Note : Measurements for the purpose of payments shall be made by measuring horinzontal distance between centers of two adjacent poles and adding 3% extra for sag, joints, jumpers etc.
Taking down old insulator any type and make from existing over head line and poles/stay after dismantling electrically and removal from site being contractor property as included in credit schedule
M&L for Pin type, porcelain, viterous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height,65 mm dia for 1100 volts grade.
M&L for Shackle type, porcelain, viterous white, brown or green insulator including galvanised mild steel straps with section of straps 31 X 3 mm, dia of bolts 12 mm and working pressure 1100 volts of size 75 mm height and 90 mm max dia complete all as specified and directed by Engr-in-Charge.
Restraining of existing ACSR conductor of any size on LT over head line on LT poles without taking down of ACSR from over head line by disconnecting and untying from insulator and retying with new binding wire, rejoining of service connection of street light, and all other jumper rconnection including replacement of 'J' hooks if required. complete all as specified and as directed. Note : (One unit length consists of three phase and one neutral conductor and one street light conductor (FIVE ACSR conductors PLUS TWO earth wire and cradle guard).
Dismantling cross-arms of M.S. channel or angle sections etc. stacking for inspection for serviceable items suitable for re-use all as directed by the Engineer-in-Charge.
Refixing of mild steel channel angle iron,flat iron and brackets etc as in cross arms, bracings, supports, D-clamps, stiffeners,eye hooks, bolts,pole clamps removed and taking down from item no 19 as in new position with new nut bolts all as specified and directed by engineer in charge.
Suply, fabricating , fixing structural mild steel channel angle iron,flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners,eye hooks, bolts,pole clamps and back plates including nuts, bolts and washers, welding banding cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and inclusive of one coat of aluminum red oxide primer,one under coat and one finishing coat of aluminium paint complete.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.3mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 25x4 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion.NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above groung level.
M&L for cutting of bituminous road/ floor not exc 45cm wide and n. exc 1.5m deepfor laying of pipe/cables n. exc 1.5m wide including refilling with material and watering Cement concrete not less than 25cm thickness in pavement/hard-standing of flexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre, complete all as specified and directed. Note: (i) Road cut shall be done with prior written permission of the Engineer-in-Charge. (ii) Repairs to road cut shall be carried out within 24 hours of making cut and road surface shall be made flush with existing black top surface/ path etc as approved by the Engineer-in-charge. (iii) The rate of this include the cost of excavation, returning/filling, removal of surplus spoil, filling materials, compaction and provision of PCC and finishing the wearing road surfaces to entire satisfaction of the Engineer-in-Charge. (iv) Cable and GI Pipe embedded in road cut shall be measured and paid seperately under respective item of BOQ.
S&F in replacement of GI Pipe medium grade on Wall/Floor/Road/Pole for cable protection with fixing arrangement size 100 mm dia.
S&F in replacement of GI Pipe medium grade on Wall/Floor/Road/Pole for cable protection with fixing arrangement size 80mm dia.
S&F in replacement of GI Pipe medium grade on Wall/Floor/Road/Pole for cable protection with fixing arrangement size 50mm dia.
S&F in replacement of GI Pipe medium grade on Wall/Floor/Road/Pole for cable protection with fixing arrangement size 40mm dia.
Taking down old/ unserviceable UG cable of any description of size 10 to 150 Sqmm 2/3.5/4 core stacking for inspection, complete all as directed by the Engineer-in-Charge. Note: (i) Excavation / Earth work , Sand Cushion & Bricks shall be measured and paid seprate under relavent items. (ii) Retrieved UNSV cable shall be deposited in MES Store Yard of AGE E/M Dronachal. (iii) Retrieved UNSV cable shall be removed after inspection the Engr-in-Charg. Gate Pass duly signed by the Engineer-in-Charge and GE shall be issued to the contractor for the same and accordingly recovery shall be effected from contractor dues on the rates given in credit schedule.
Relaying the serviceable cable taken out from item No 28 of size 10 to 150 Sqmm 2/3.5/4 core in same or other places after tracing out the fault with the help of megger in presence of Engr-in-Charge and rectifying the defects. Note:(i) Unserviceable cable stacked seperately (ii) Straight through joint shall be measured and paid seprate under relevent item of schedule. (iii) New cable shall be used if required at site examine and paid seperately under respective items.
Supplying, Laying & Jointing of XLPE cable 1100 volts grade armoured of following sizes with Aluminium Conductor stranded including necessary connection complete with lugs, glands all as specified and directed (Excavation, earth work, returning filling, sand cushioning, brick protection to be measured and paid separately).
(a) Cross sectional area 95 Sqmm 3.5 Core.
(b) Cross sectional area 70 Sqmm 3.5 Core.
(c) Cross sectional area 50 Sqmm 3.5 Core.
(d) Cross sectional area 35 Sqmm 3.5 Core.
(e) Cross sectional area 25 Sqmm 4 Core.
(f) Cross sectional area 16 Sqmm 4 Core.
(f) Cross sectional area 10 Sqmm 4 Core.
M&L for clean, dry, unwashed sand filled in trenches for cushioning to cable complete all as specified. NOTE:- The depth of cushion after punning shall be measured.
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead 25 x 4 mm GI strip laid in pipe/ fixed to poles or any other indicated situation including jointing by using GI nuts, bolts, washer and saddle in addition to welding complete and all as specified and directed. Note: GI Pipe to be measured and paid seperately under respective item of BOQ.
S&F PVC line separator suitable for 3 way, 4way 5 way on LT line all as directed.
M&L for spray painting with one coat of synethetic enamel paint for outdoor/indoor panel board of size 2 x 2 x 0.5 mtrs outer & innner side complete alongwith two coats of lime wash on plinth of panel board including connected accessories in any size and welded hingeg , locking arragement complete all as specified and directed by Engineer-in-charge
Servicing of Indoor/outdoor Panel Board incl repair/replacement of defective parts like digital ammeter , digital volt meter, Indicating lamps, CT coil, control wiring etc and all as directed by Engr in Charge. Note :- digital ammeter , digital volt meter, Indicating lamps, CT coil shall be measured and paid separately under supply only items.
supply only Digital Volt Meter 0-500 V
supply only Digital Ammeter Meter 0-500 Amps
supply only Indicating lamps
supply only CT coil 400/5 Amps
S&F in repalacement of MCCB, Four pole of following current capacity adjustable thermal fixed magnetic setting as per following range, AC 415 volts overload/short circuit protection type complete with connected accessories including necessary connection with bus bar and out going cables all as specified and directed.
(a) 630 Amps with 50 KA rupturing capacity
(a) 400 Amps with 36 KA rupturing capacity
(b) 250 Amps with 36 KA rupturing capacity
(c) 200 Amps with 36 KA rupturing capacity
(d) 160 Amps with 36 KA rupturing capacity
Cutting and Trimming of tree branches touching LT over head lines & clear the vegetation / grass around the LT pole maintain a clearance of 1.50 M radius of the pole and trimming of branches in each span of LT over head line complete all as directed Note: (a) an area of 1.5 M surrounding the pole to be cleared off vegetation/grass & cutting of trees branches. (b) The item shall be repeated after three months from the date of first trimming as directed by Engr in charge. (c) Measurement and payment will be made for each cutting/trimming as a job.
M & L Surface excavation not exceding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil including removing green vegetation, roots, bushes, etc from surrounding of Lt Feeder Piller Boards./Poles/ substations etc. all as directed by Engineer-in- charge.
M&L for scratching out old bubbled paint, finishing the surface with one coat of aluminium primer & two coats of aluminium paint of 1st quality to steel tubuler poles of any height 7/9 mtr , any type (double swan, single swan) all as per site including four strips of 30 cm wide to be painted red and black alternatively using synthetic enamel paint (First Quality) above embedded level, including pole number writting with white colour enamel paint on black colour circular base) with two coat of lime wash on pole coping all as directed by Engr-in-charge.
Supply & fix as in replacement Cable twin core flat or circular, stranded of size 6 sqmm 1100 volts grade heavy duty PVC insulated aluminium conductor, and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm suspension wire, complete all as specified.
Supply & fix as in replacement Cable twin core flat or circular, stranded of size 10 sqmm 1100 volts grade heavy duty PVC insulated aluminium conductor, and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm suspension wire, complete all as specified.
Supply and fix in repair LT cable joiniting kit 1100Volts grade cable for indoor/outdoor joint heat shrink type complete with jointing material and accessories suitble for 4 core XLPE armoured aluminium conductor cable of size 35 to 150 sqmm
Supply and erecting in replacement LT PCC pole 9 Mts long cross sectional area 102 mm x 172 mm at top and 102x279 mm at bottom class 10 complying with requirement of relevant IS and including marking alternate red and black strips 30 cm high each , total of 04 Nos , commencing from the top of PCC coping and writing pole Nos (letters and figures) (Block, Roman, Italic or Indian) of size as directed with synthetic enamel 1st quality paint complete all as specified and directed. Note:- Excavation, PCC in foundation and coping shall be measured and paid for separately under relevant items.
PRAGATI ELECTRICALS AND ELECTRONICS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .