Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC C 92 JAIN NAGAR RAILWAY ROAD MEERUT UP | L1 | Accepted-AOC Being L1 accepted | |
| 2 | L2₹21.2 L+₹89,724 (4.41%)Rejected-AOC 283 ALIEN MARKET SADAR KABARI BAZAR MEERUT CANTT UP | L2 | Rejected-AOC Being L2 rejected | |
| 3 | L3₹22.8 L+₹2.5 L (12.4%)Rejected-AOC 10 RAJAN KUNJ ROORKEE ROAD MEERUT UP PIN 250110 | MEERUT | UTTAR PRADESH | 250110 | L3 | Rejected-AOC Being L3 rejected |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
19 Jun 2021, 6:00 pmClosed
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt, The Mall Road Distt Meerut-250001
REPAIR TO CHAJJA , FACIA, LEAKAGE, SEEPAGE AND MISC B/R WORK TO OTM AND MD ACCN IN ZONE-V UNDER AGE B/R-IV OF GE(SOUTH) MEERUT CANTT
2021_MES_443361_1
GE/MRT/S/8855/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please prefer tender documents
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹70,000
Yes
19 Jul 2021
17 May 2021
21 Jun 2021
17 May 2021
19 Jun 2021
5 Jun 2021
Amount
Dismantling of brick tiles or terracing tiles pointed in cement mortar and removing rubbish etc outide the MOD land complete all as specified and directed by Engr-in-Charge.
Demolition of mud phuska under brick tiles as in roof of any thickness incl plastering and leeping plaster etc (either full thickness removed or only a part thereof) including wire brushing, cleaning the roof surfaces, flashing and junction of parapets with water complete all as specified & directed by Engr-in-Charge.
Material and labour for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement complete all as specified and directed.
Material and labour for rendering 15 mm thick (average thickness) on roof surface/chajja including flashings and junction of parapets etc., finished even and smooth in cement mortar (1:4) using water proofing compound as per manufacture's instructions after applying neat cemet slurry @ 3.0 kg of cement per Sqm complete all as specified and directed by Engr-in-Charge. ( Note:- WPC shall be measured and paid separately under respective item of BOQ)
Supply only Liquid water proofing compound complete all as specified and directed
Material and labour for cutting out cracks to V section to 25 mm depth in existing roofs or terracing, cleaning out, wetting and painted with shalitex primer and filled with sealing compound grade 'B' complete all as specified and directed
Material & labour for cleaning of concrete surfaces and applying priming coat using with bituminous primer @ 0.30kg per Sqm followed by evenly a tack coat @ 1.20 kg per Sqm using with 85/25 grade industrial bitumen, over it laid with 3mm thick APP modified polymeric water proofing membrane with non-woven polyester reinforced of weight not less than 3.6 kg per Sqm unrolled & bonded to substrate with side and end laps 75mm & 100mm as per manufacturer’s instruction and applying over it a tack coat using with 85/25 grade industrial bitumen @ 1.20 kg per Sqm and finally finished the top of polymeric water proofing membrane with a coat of bituminous aluminum paint @ 0.200 kg per Sqm as per manufacturer’s instructions complete all as specified and directed.
Material and labour for 40mm thick brick tiles laid over and including 20mm thick cement screed in CM 1:6 and jointed grouted flush pointed in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed
All as per item No 8.00 above but except brick tiles including cleaning of brick tile obtained from dismantling for reuse complete all as specified and directed.
Material and labour for cleaning and clearing vegetation, debris from roof top, chajja etc. and disposal of the same to a distance n.exc 100 metre complete all as specified and directed.
Taking down cement plaster on RCC chajja,roof slabs and projection on top of chajja etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed .
Material and labour for rendering 15 mm thick (average thickness) on RCC chajja, roof slabs and projection on top of chajja roof surface including flashings and junction of parapets etc., finished even and fair in CM (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 3.0 Kg of cement per Sqm complete all as specified and directed by Engr-in-Charge. ( Note:- WPC shall be measured and paid separately under respective item of BOQ)
Material and labour for repairs to CI/AC rain water pipes gutter for arresting leakage using rubber or fibre based gaskets or cement upto 4th storey and applying one coat of white washing to soffit of chajjas and canopy, upto 4th storey height complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old/new plastered wall surfaces and applying two coats of cement base paint over one coat of cement primer complete all as specified and directed.
Material and labour for preparation of new decorated wall surfaces plastered and applying two coats of weather proof exterior acrylic emulsion paint over and including a coat of primer complete all as specified & directed by Engr-in-Charge
Disconnecting existing tanks, setting aside (or lowering if requred) for repairs, cleaning etc and hoisting reconnecting and refixing in position after roof repair capacity of tanks exc 250 Ltr but n. exc 500 Ltrs complete all as specified and directed by Engr-in-Charge.
All as per item No 16.00 above but 1000 ltrs capacity.
Supply and Fix in repair 20 mm bore, PTMT ball valves, high pressure with polyethylene float and fly nut, including epoxy coated aluminium rod, screwed for iron pipe or for brass ferrule complete all as specified and directed.( Min wt -210 grams )
Supply and fix rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified , 500 Ltrs Capacity incl dismantling old water tanks complete all as specified and directed by Engr-in-Charge .
Supply and fix Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 1000 Ltrs Capacity incl. dismantling water tanks complete all as spd and directed by Engr-in-Charge .
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc complete all as specified and directed.
Material and labour for brick work with fly ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed.
Material and labour for brick work using old size bricks (except Bricks) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed.
Taking down of rain water pipes of any dia including all fittings, heads, shoes, bends, swan neck etc set in cement mortar complete all as specified and directed.
Supply and fix 110 mm dia PVC/ SWR pipes single socketed in any length with rubber ring joints fixed to wall with and including fixing of MS clamps made out of flat iron of size 25mmx3mm including nuts & bolts etc fixed at every 2 mtr distance complete all as specified and directed.
Supply and fix PVC bends plain(any radius) for 110 mm bore pipe complete all as specified and directed.
Supply and fix GI tubes fixed in repair medium grade' with all fitting complete fixed to walls & ceilings or laid under floors of 15mm bore complete all as spd and directed.
All as per item no 27.00 herein -in-before but20mm bore of pipe complete all as spd and directed
Taking up or down steel tubing & connections, including cleaning & Refixing old steel tubing & connections in new or old position (Walls, ceiling, floors, etc.) of 15mm bore complete all as spd and directed
All as per item no 29 above but for 20mm bore of pipe complete all as spd and directed
Supply and fix in repairs PVC connections 450mm long with PTMT nuts for fixing to 15mm bore pipe complete all as specified and directed.
Supply and fix in repair bib tap long body CP cast copper alloy fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed.
Supply and fix as in repair 15 mm bore bib tap long body standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight 90gms).
Supply and fix as in repair chromium plated cast copper alloy angle stop valve incl flange, any description, suitable for 15 mm bore pipe,complete all as specified and directed.
Supply and fix in repair brass spindle of No 2 / 3 / 4 or die 5 No for CP pillar tap / bib taps / angle cock complete all as specified and directed.
Supply and fix in repair legs for CP brass mixer (S alphabat shape) suitable for wall sink mixer wall mixer etc screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
Supply and fix in repair for standard kit of PVC internal fitting for low level flushing cistern fixed, complete all as specified & directed.
Supply & fix in repair PVC waste pipe 32/40mm bore heavy duty to WHB/Sink etc, complete all as specified and directed.
Material & labour for provision of Aluminium anodized frame work(snap grid) suitable for size as in false ceiling of size 605mmx605mm including fixing of 4mm thick gypsum board/ E-borad in ceiling size 60cmx60cm fixed to metacil snapgrid & dismantling wall ceiling board or insulation board/slab any thickness incluidng cover fillets & providing followings and all as directed:-i) Aluminium sections incorporated in frame work shall conform to designation 63400 given in IS: 737-1986. ii) The snap grid shall consist of aluminium anodized main /cross tee of size 36.5mmx25mmx1.4mm thick and 25mm x 25m x1.4mm thick, respectively. iii) Snap grid frame shall be fixed to ceiling with and including supporting hangers consisting of 4mm dia mild steel GI wire. iv) The main and cross tees shall be jointed at junction/crossings with aluminium anodized angle bracket, of size 15mmx15mmx1.5mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer’s instructions. v) The snap grid (main/cross tee section) shall be supported at ends all along the wall with aluminium anodized angle of size 25mmx25mmx1.4 mm anodized thick. vi) Size of the snap grid shall be 605mm by 605mm. vii) Minimum average thickness of anodizing shall be 15 micron complete all as specified and directed
Material and labour fibre cement sheet 6mm thick corrugated or semi-corrugated fixed in roofs, wall etc with J or L cranked hooks bolts including dismantling of old sheet of any description as in roof coveringg incl ridge and removing from site complete all as specified & directed
Dismantling plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering complete all as specified and directed.
Supply and fix 0.63mm thick plain galvanised, MS sheeting as in ridges, crumple section, hips, valley gutters, drips and straight flashings (length & girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding, ridges, fixed with self tapping screws as per manufacturer's instructions complete all as specified and directed.
vibha associates
SHAKTI CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .