Loading…
Loading…
Tender Value
₹12.7 Cr
EMD Value
₹7.8 L
Closing Date
30 Jan 2026, 3:00 pmClosed
Yes (up to 2 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
WORKS
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'Total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of IRGCC 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. NOTE: FOR DETAILS PLEASE REFER TENDER DOCUMENT.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for (b) (i): Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 (a) (ii) of Part-II of GCC or through subcontractor fulfilling the requirements as per clause 7 of Part-II of GCC or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of Part-II of GCC, with prior approval of Chief Engineer in writing. NOTE: FOR DETAILS PLEASE REFER TENDER DOCUMENT.
Defination of Similar Work :- The Similar nature of work required as qualifying criteria in this case of tender is "Panel Interlocking or Route Relay Interlocking or Electronic Interlocking or IBH or Automatic Signalling or LC gate interlocking".
4 conditions · 1 needing a document upload
CHECKLIST OF ITEMS TO BE COMPLIED BY THE TENDERERS
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
"REPLACEMENT OF AFTC AND AUTOMATIC SIGNALLING SYSTEM IN KALUBATHAN- CHHOTA AMBANA SECTION WITH DUAL MSDAC AND PROVISION OF DUAL DETECTION WITH MSDAC FOR ABS IN SITARAMPUR-BARAKAR SECTION IN ASANSOL DIVISION OF EASTERN RAILWAY (TWO PACKET SYSTEM TENDER)"
SGW-272-156-T1-61~ER
SGW-272-156-T1-61
Open
Works - General
12 Months
Kolkata, West Bengal
₹0
₹7.8 L
30 Jan 2026
7 Jan 2026
16 Jan 2026
150 items across 3 schedules · ₹12,76,35,711.87 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| "Supply, Transportation, Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) for mentioned detection Point by the purchaser & Track Section as per SIP uploaded with the tender, complete with all accessories, cable required with each track device & Card viz., Axle Detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated Rack to be supplied along with the system), Reset unit, Relay unit, Event logger & Diagnostic terminals etc. required for different Detection Points & Track Sections as per RDSO Specification No. RDSO/SPN/176/2013, Ver.3 or latest as per Annexure O-4 of TENDER DOCUMENT " | Per Detection Point (DP) | 84.00 | 3,42,558 | 2,87,74,872 | |
| 2 | "Supply of Control card for evaluators of Multi Section DAC along with power supply card or Equivalent. Inspection:RDSO | Numbers | 15.00 | 2,15,031 | 32,25,465 |
| 3 | "Supply of Input / Output card for Evaluators for ""detection Point"" or Equivalent. Inspection:RDSO | Numbers | 15.00 | 46,674 | 7,00,110 |
| 4 | Supply of Input / Output card for Evaluators for relay driver and final track clearance relay or Equivalent. Inspection: RDSO | Numbers | 15.00 | 57,334 | 8,60,010 |
| 5 | Supply of Double Rail contact assembly with track side EJB for MSDAC. Each set shall consist of track side Electronic unit, Double rail contact with cable and mounting accessories. Inspection: RDSO | Set | 15.00 | 2,41,792 | 36,26,880 |
| 6 | "Supply of PVC insulated Railway Signalling multicore Indoor Cable 60 core (0.6mm dia) conforming to IRS:76/89(Amd3) or latest. Inspection:RDSO | Kilometre | 4.00 | 1,51,032 | 6,04,128 |
| 7 | "Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn. No. IRS: S- 76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO | Kilometre | 4.00 | 7,669 | 30,676 |
| 8 | Supply of 1 x 16 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS: 694:2010 or latest, 126 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer incharge. Inspection:RDSO | Metre | 620.00 | 131 | 81,220 |
| 9 | "Installation and wiring of relay rack as per DRG.NO.S&T/C-20/2001 with modification vide CSTE/ER'S LETTER NO.SG.42/9, DT.15/3/2016. Supply and fixing of fuses with base, diodes; resistances; condensers, terminal strips / tag blocks, bus bars & other equipment's required for the approved system design complete with scaffolding materials & required hardware & erection materials to accommodate 100 relays (station wise quantity to be specified by the tenderer). PVC wire as per RDSO SPEC.IRS-S-76/89, AMD-2 or latest (for wiring of relay rack) shall be supplied by the contractor, duly inspected by RDSO. This includes supply of relay rack to accommodate 100 relays complete with fittings as per DRG.NO.S&T/C- 20/2001. Note: - this includes status of relay to be indicated through led indication at the top of relay rack and in this connection all the required materials to be supplied by the contractor. Rack to be fixed on rubber pad. .....Supply. Inspection: Consignee | Numbers | 8.00 | 25,535 | 2,04,280 |
| 10 | "Installation and wiring of relay rack as per DRG.NO.S&T/C-20/2001 with modification vide CSTE/ER'S LETTER NO.SG.42/9, DT.15/3/2016. Supply and fixing of fuses with base, diodes; resistances; condensers, terminal strips / tag blocks, bus bars & other equipment's required for the approved system design complete with scaffolding materials & required hardware & erection materials to accommodate 100 relays (station wise quantity to be specified by the tenderer). PVC wire as per RDSO SPEC.IRS-S-76/89, AMD-2 or latest (for wiring of relay rack) shall be supplied by the contractor, duly inspected by RDSO. This includes supply of relay rack to accommodate 100 relays complete with fittings as per DRG.NO.S&T/C- 20/2001. Note: - this includes status of relay to be indicated through led indication at the top of relay rack and in this connection all the required materials to be supplied by the contractor. Rack to be fixed on rubber pad. -----------"EXECUTION OF ITEM NO.9." | Numbers | 8.00 | 83,032 | 6,64,256 |
| 11 | "Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority:- RDSO. " | Numbers | 75.00 | 3,845 | 2,88,375 |
| 12 | "Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""ABDFH"". Inspection authority: - RDSO." | Numbers | 75.00 | 4,007 | 3,00,525 |
| 13 | "Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""ABCDF"". Inspection authority:- RDSO. " | Numbers | 75.00 | 3,737 | 2,80,275 |
| 14 | Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc. and conforming to BRS- 930 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date or latest. The interlocking code for this unit shall be "ABCDE". Inspection authority: - RDSO. | Numbers | 75.00 | 3,769 | 2,82,675 |
| 15 | Carrying out relay alteration to the existing relay wiring at relay rack/location box as per the approved circuit diagram. These works include the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection: by RDSO. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work. | Per Relay | 800.00 | 270 | 2,16,000 |
| 16 | "Inter connection wiring with ladder arrangement from control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRS, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables/ wires on all the above and dressing, bunching etc. As required at site. 16 sq. mm. cable to be used between IPS & its battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm, 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires/ cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note :1) necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. 2) to suit load requirement necessary re-arrangement of DC-DC converters by OEM of IPS... Up to 6 Lines Station/Cabin/Hut." | Station | 4.00 | 1,31,515 | 5,26,060 |
| 17 | Supply of IPS DC-DC converter 24-32V DC, 5 Amp /10 Amp or 60-66 V DC, 5 Amp or 60-100V DC,1 Amp/3 Amp/5 Amp as per specification No.RDSO/SPN/165/2023 version 4.0 Amendment 1.0 (Or latest). Make: Make: M/s. Statcon Ltd./ M/s. HBL Ltd./M/s. Amara Raja Ltd. Or Other RDSO approved make,compatible for the IPS make specified by Purchaser. INSPECTION:RDSO | Numbers | 75.00 | 24,351 | 18,26,325 |
| 18 | "ALteration work:- Inter connection wiring with ladder arrangement from control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRS, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables / wires on all the above and dressing, bunching etc. As required at site. 16 sq. mm. cable to be used between IPS & it's battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm., 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires / cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note:1) necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. 2)to suite load requirement necessary re-arrangement of DC-DC converters by OEM of IPS." | Station | 30.00 | 69,824 | 20,94,720 |
| 19 | "Supply of paper base hylam sheet 12 mm thick. Inspection: consignee." | Sqm | 35.00 | 5,370 | 1,87,950 |
| 20 | "Fuse, non- deteriorating(2A/6A/10A/16A) type, cylindrical (IRS-S-78/92) [quantity as per site requirement]." Inspection:RDSO | Numbers | 800.00 | 61 | 48,800 |
| 21 | Supply of PBT Fuse base. Inspection:RDSO | Numbers | 100.00 | 178 | 17,800 |
| 22 | "Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway is not available, 4"" of 1:2:4 concreting should be done. Note:- (b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment." | cum | 15000.00 | 245 | 36,75,000 |
| 23 | "Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC- 77/2012 revision 3 With latest Amdt." Inspection:RDSO | Numbers | 50.00 | 2,185 | 1,09,250 |
| 24 | "Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost." | Numbers | 50.00 | 956 | 47,800 |
| 25 | "Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes." | Kilometre | 100.00 | 5,000 | 5,00,000 |
| 26 | "Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. Of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS- 08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer." | Metre | 7000.00 | 1,758 | 1,23,06,000 |
| 27 | "Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in- charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed." | cum | 1500.00 | 278 | 4,17,000 |
| 28 | "Supply of Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (2-meter-long) along with collars as per IS No. 458/2003 of NP type." Inspection:RITES | Numbers | 15000.00 | 679 | 1,01,85,000 |
| 29 | Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately). | Metre | 15000.00 | 22 | 3,30,000 |
| 30 | "Supply of Double Wall Corrugated (DWC)-HDPE pipe/duct of size 200 mm outer dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Specn.No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part-II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-capDWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified." Inspection:CONSINEE | Metre | 700.00 | 397 | 2,77,900 |
| 31 | Placing of DWC HDPE/RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. | Metre | 700.00 | 31 | 21,700 |
| 32 | "Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as: - Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench" Inspection:CONSIGNEE | cum | 40.00 | 3,596 | 1,43,840 |
| 33 | "Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches. The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area, cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground cannot be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables are small. In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.1.2 mtr is not possible and it will be decided by site engineer/unit officer in-charge of work." | cum | 1000.00 | 497 | 4,97,000 |
| 34 | Supply of earth electrode (GI PIPE) as per CSTE/ER'S (Drg No. SI/TYP/0097 dated 25.03.25)..Inspection:CONSIGNEE | Numbers | 110.00 | 1,496 | 1,64,560 |
| 35 | "Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. S&T-1/2007 (or latest). Inspection: by Consignee." | Numbers | 110.00 | 911 | 1,00,210 |
| 36 | Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per PCSTE/ER'S DRG. NO. SI/TYP/0097 dated 25.03.2025 or latest. for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Where required necessary holes to be drilled on the MS Flat . Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside (bolts of 10 mm dia and length 40 mm should be supplied by the contractor). Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Sig. Cable as provided by Railway is also to be laid and terminated on Earth Electrode and to GI Wire/GI Flat in Location Box. | Numbers | 110.00 | 1,161 | 1,27,710 |
| 37 | Provision of cement concrete enclosure for earth electrodes as per CSTE/ER'S (Drg No. SI/TYP/0097 dated 25.03.25 ). This includes supply of all materials by the contractor duly inspected by consignee. | Numbers | 170.00 | 571 | 97,070 |
| 38 | "Supply of 1 x 10 Sqmm (140/0.3 mm) multi strand copper power wire as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer in-charge. Inspection: RDSO | Metre | 840.00 | 119 | 99,960 |
| 39 | "Alteration/modification in the existing location boxes (Full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same" | Numbers | 60.00 | 2,782 | 1,66,920 |
| 40 | "Supply of full size apparatus case (GKP type) (as per DRAWING NO. SW SK NO. 4/90 && other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy " | Numbers | 60.00 | 13,916 | 8,34,960 |
| 41 | "Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti-corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside. Inspection: Consignee " | Numbers | 60.00 | 3,532 | 2,11,920 |
| 42 | Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for full size apparatus case with termination &Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. Inspection: Consignee | Numbers | 60.00 | 4,830 | 2,89,800 |
| 43 | Supply of hard wood shelves thickness 25 mm for keeping equipments and batteries in the location box with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts....950 x 400 x 25 MM for full size location box. Inspection: -Consignee. | Numbers | 60.00 | 563 | 33,780 |
| 44 | Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc. under supervision and instructions issued by Engr. In-charge of the work. Inspection: Consignee. | Per Conductor | 1800.00 | 9 | 16,200 |
| 45 | Supply of PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm only........6 WAY, DRG.NO.23756, ALT-3 or latest. Inspection: RDSO. | Numbers | 360.00 | 485 | 1,74,600 |
| 46 | Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). Inspection: RDSO | Numbers | 6240.00 | 55 | 3,43,200 |
| 47 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments...... Supply of Disconnect Terminal Block, screw less type, 2-wire front entry (One in-put & One out-put) The color will be decided by Engineer - in - Charge.(Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3)".Inspection: RDSO | Numbers | 600.00 | 56 | 33,600 |
| 48 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of End plate 2.5mm/0.091 in thick as per site requirement. Inspection: RDSO | Numbers | 1120.00 | 10 | 11,200 |
| 49 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of End Stopper 10mm/0.0394 in width as per site requirement. Inspection: RDSO | Numbers | 120.00 | 10 | 1,200 |
| 50 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. Inspection: RDSO | Metre | 220.00 | 109 | 23,980 |
| 51 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of Markers strip. Inspection: RDSO | Numbers | 360.00 | 16 | 5,760 |
| 52 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of shorting link (jumper) (part no - 283-402 or similar), suitable for 0.2 to 16 sqmm terminal block 283-901 or similar. Inspection:RDSO | Numbers | 720.00 | 2 | 1,440 |
| 53 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of Fuse terminal block with LED indication up to 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004 (without fuse). Inspection: RDSO | Numbers | 240.00 | 189 | 45,360 |
| 54 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments......Supply of Fuse links of (400 mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A). Inspection: RDSO | Numbers | 240.00 | 45 | 10,800 |
| 55 | "Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE: - The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) of Apparatus Case Full Size. (Outside & inside)." | Numbers | 60.00 | 260 | 15,600 |
| 56 | Design of circuits and plans to suit layout given in the signalling plan of IBS/ABS/LC GATE. All plans and wiring diagram shall be prepared on Auto Cad Drawing and supplied with CD. This will include supply of Control cum Indication panel diagram, Route section plan, square sheet, wiring diagrams, Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement with program switch, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings. NOTE: The contractor shall initially supply 2 sets of documents (Paper Prints) for approval of Railways. Railway will return one set to the contactor duly approved with alterations/corrections, if any. The contractor shall incorporate Railways' alterations/ corrections/ comments, if any, in the tracing & CD without any deviation and submit all the tracings and Final CD complete with all respect for Approval of Railways. After Approval of Railways on the tracings, the contractor shall submit 3 sets of final approved diagrams to the Railways within 15 days. He shall ensure that each sheet has a block for signature of railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each IBS/ABS/LC Gate. | Lot | 10.00 | 12,214 | 1,22,140 |
| 57 | "Installation of cable termination rack with scaffolding materials ladder for supporting outdoor cable; wire guide completes with other necessary hardware as per requirements of rly. & erection materials. Wires to be procured from RDSO's approved firm only. This includes supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago / Phoenix/Similar), scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. :: Supply. Inspection: CONSIGNEE | Numbers | 10.00 | 44,924 | 4,49,240 |
| 58 | "Installation of cable termination rack with scaffolding materials ladder for supporting outdoor cable; wire guide completes with other necessary hardware as per requirements of rly. & erection materials. Wires to be procured from RDSO's approved firm only. This includes supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago / Phoenix/Similar), scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials ::"EXECUTION OF ITEM NO.66 " | Numbers | 10.00 | 5,790 | 57,900 |
| 59 | Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x 1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the tenderer. | Numbers | 40.00 | 6,674 | 2,66,960 |
| 60 | "Supply of optic fiber splice closure (24 fiber) as per tec. Specification no. G/OJC-02/01, March'99 with latest amendment or latest including all miscellaneous items and consumables for fiber splicing. Inspection: - by consignee." | Numbers | 40.00 | 3,558 | 1,42,320 |
| 61 | "Jointing, terminating & splicing of 24 fiber optic fiber cable and fixing of termination box/FDF/placing of joint closures in the pit required at various locations including transportation of all the jointing & terminating materials from railway store to the work site and returning leftover materials to the railway store." | Numbers | 40.00 | 10,625 | 4,25,000 |
| 62 | Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll for each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection:RDSO | Kilometre | 40.00 | 62,867 | 25,14,680 |
| 63 | Modification/ upgradation, validation and alteration of data logger as per site engineer. This includes changes of NMDL software etc. Also, data logger to be interfaced with PI/ EI equipment keeping at relay room. This work includes validation, wiring, etc. For this work necessary wire from relay to tag block & from tag block to data logger and tag block, terminal, wiring material etc. required for this work to be supplied by contractor. Wire to be procured from RDSO approved firms and to be inspected by consignee | Set | 10.00 | 49,160 | 4,91,600 |
| 64 | "Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends." Inspection:RITES | Metre | 800.00 | 762 | 6,09,600 |
| 65 | "Laying & Fixing of Medium class GI pipes 50/100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends." | Metre | 800.00 | 98 | 78,400 |
| 66 | "Supply, installation and complete indoor wiring of 19 inch (42U) covered Rack of size 2035 mm x 600 mm x 600 mm (Approx.). The rack shall be complete with all fittings for housing SDH equipment, Primary MUXES, DDF, MDF using crone modules and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack. Inspection: Consignee." | Numbers | 4.00 | 37,570 | 1,50,280 |
| 67 | "Supply of color light signal post 4.6 mtrs. and ladder 4.5 mtrs. with bases for ladder and post as per RDSO SPEC. NO. IRS-S-6-81 and DRG. NO. SA- 23153/ADV/AIT-1. All drawing should be as per latest. Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured from approved list of firms for manufacturer & supply of mechanical signalling items. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 20.00 | 15,950 | 3,19,000 |
| 68 | "Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 4 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only.Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water......Supply. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs. (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 20.00 | 30,783 | 6,15,660 |
| 69 | Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 4 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only.Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water.....Execution portion. | Numbers | 20.00 | 2,730 | 54,600 |
| 70 | Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C- 42(NKG). | Numbers | 20.00 | 8,065 | 1,61,300 |
| 71 | Supply of cast iron offset bracket for Main Signal with U clamps, nuts, washers complete DRG. NO. SA- 23080/ADV/ALT-1. RDSO SPEC. NO. IRS- S-10/78. Inspection: consignee. Note: Offset bracket has to be connected wherever necessary as per site engineer. | Numbers | 10.00 | 2,513 | 25,130 |
| 72 | Supply of LED signal lamps for Main Colour Light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/199/2010 (Rev.1.1) or latest.....Supply of RED Aspect. Inspection:RDSO | Numbers | 20.00 | 8,362 | 1,67,240 |
| 73 | Supply of LED signal lamps for Main Colour Light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/199/2010 (Rev.1.1) or latest.....Supply of YELLOW Aspect. Inspection:RDSO | Numbers | 40.00 | 8,387 | 3,35,480 |
| 74 | Supply of LED signal lamps for Main Colour Light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/199/2010 (Rev.1.1) or latest.....Supply of GREEN Aspect. Inspection:RDSO | Numbers | 20.00 | 9,438 | 1,88,760 |
| 75 | "Supply of A -sign / AG - LED Signal Lighting Unit retrofittable in existing CLS housing and compatible with AC LED ECR (As per spec. RDSO/SPN/199/2010 Rev 1.1 or Latest with Brackets & Fixing accessories. Inspection: Consignee." | Numbers | 10.00 | 2,601 | 26,010 |
| 76 | "Fixing of Calling-on Signal/A-Sign/AG- Sign unit on signal post including Guard Repeater Signal. The item includes fixing of Co- On signal /'A' sign/ 'AG' sign unit on signal post with bracket, hood etc. Item includes supply of bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/ 'AG' sign unit as per standard practice. Inspection: Consignee." | Numbers | 10.00 | 2,331 | 23,310 |
| 77 | "Supply and installation of P/ C / G/ A/ AG marker (size 250mm dia circle) high intensity prismatic (TYPE-IV) retro reflective sheet over 2 mm thick aluminium sheet & letter will be screen printing (250 mm dia circle) as per drg. S&T/SDAH/SK-1383 and technical specification attached. This will include cost of all materials including fixing clamp required for this work. Inspection: -CONSIGNEE | Numbers | 20.00 | 550 | 11,000 |
| 78 | "Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post per DRG. NO. S&T/SDAH/SK-1386 and as per standard practice. Inspection: CONSIGNEE | Numbers | 20.00 | 373 | 7,460 |
| 79 | "Dismantling of existing main signal including dependent shunt signal, calling on signal if any, fitted on the same post along with signal post, signal unit, ci base without damaging any part." | Numbers | 20.00 | 1,218 | 24,360 |
| Schedule total | ₹8,34,29,152 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .